• Title/Summary/Keyword: 인체팬텀

Search Result 198, Processing Time 0.024 seconds

Study of Appropriate Increment during VRT Rendering before Musculoskeletal Surgery (근골격계 수술전 VRT Rendering시 적절한 increment에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.675-681
    • /
    • 2019
  • The purpose of this study was to investigate the effect of increasing the amount of 3D volume imaging on the hand, knee, and foot human phantom in CT, After analyzing the data, three - dimensional volumetric images were implemented using MMWP program to evaluate reproducibility. First, the data amount of three human phantoms according to each increment was analyzed. Secondly, the reproducibility evaluation and the measured length were compared. As a result of analyzing the amount of image data for each phantom according to the increment, it was confirmed that the amount of data is reduced to about 1/10 when the increment is set to 1.0 mm as compared with the case where the increment is set to 0.1 mm. In the evaluation of the feasibility, gap was generated from 0.7mm for hand phantom, 0.6mm for knee phantom and foot phantom, and it was confirmed that even when the actual phantom and actual length were compared, the length was much different and the implementation was lowered. As the increment is closer to 1.0mm, the number of images is small and the 3D implementation time is small. Therefore, it is best to determine the increase before the gap of the image is generated and to apply the Increment for preoperative diagnosis. We hope that this study will be an indicator of the accurate increment setting when implementing 3D image through VRT Rendering after CT scan.

전류주입 자기공명영상기법을 이용한 내부 전류밀도 영상에 관한 연구

  • 오석훈;이병일;강현수;우웅제;이수열;조민형
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.115-115
    • /
    • 2001
  • 목적: 인체에 전류를 주입할 때, 내부의 전류밀도 분포는 인체 및 전극의 구조, 주입전류, 그리고 생체조직의 임피던스 분포에 의해 결정된다. 내부의 전류밀도 분포는 전류주입 자기공명영상기법에 의해 영상화할 수 있으며, 자기공명 전기임피던스 단층촬영법과 전자기 치료의 최적화 등에 응용할 수 있다. 본 논문은 3차원 팬텀 내부의 전류밀도 분포를 영상화하는 전류주입 자기공명영상기법의 실험결과를 기술한다.

  • PDF

A Study on the Efficiency Evaluation of Ultrasound Therapy Using Varicose Vein Simulated Tissue Phantom and Tissue Equivalent Phantom (하지정맥류 모사 생체조직 팬텀과 조직등가 팬텀을 이용한 초음파 치료효과 평가에 관한 연구)

  • Kim, Ju-Young;Jung, Tae-Woong;Shin, Kyoung-Won;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.427-433
    • /
    • 2018
  • Because of the expectation of the non-invasive treatment effect, Various studies on the treatment of varicose veins using focused ultrasound are reported. In this study, the bio-tissue phantom and tissue equivalent phantom that can be applied to estimation of ultrasonic varicose veins treatment effect. Each phantom was evaluated for its usefulness by evaluating the acoustic characteristics and the shrinkage rate according to the ultrasonic irradiation. A multi-layer structure phantom with three layers of skin, fat, and muscle was constructed considering the structure of the tissue where the varicose veins occurred. The materials constituting each layer were made to have characteristics similar to human body. In addition, the multi-layered phantoms with blood vessel mimic tube, with bovine blood vessel, and with animal tissue were fabricated. The degree of shrinkage of blood vessel mimic material and vascular tissue according to ultrasonic irradiation was evaluated using B-mode image. As the results of this study, it was thought that the proposed phantom could be used effectively in the evaluation of ultrasonic varicose veins treatment. In addition, it is thought that these phantoms could be applied to the development of varicose vein treatment device using the focused ultrasound and the verification of the therapeutic effect.

An Analysis of Temperature Change and TI MI using Tissue Mimicking Phantom in Ultrasonic Examination (초음파검사에서 인체모의 매질팬텀을 이용한 온도 변화와 TI MI 분석)

  • Cheol-Min, Jeon;Jae-Bok, Han;Jong-Gil ,Kwak;Jong-Nam, Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.751-759
    • /
    • 2022
  • Currently, ultrasound examination for diagnostic ultrasound and health examination purposes is widely used, and it is showing an increasing trend due to the application of health insurance. However, the risk of ultrasound has not been clearly identified so far, and in this study, surface and deep temperature changes according to frequency and mode were measured by using a tissue mimicking phantom and TI and MI values were compared. A simulated phantom was manufactured by adding a small amount of kappa-caraginan powder with acoustic characteristics similar to that of the human body and potassium chloride for solidification, and the change of surface and depth temperature was measured using a surface thermometer and a probe thermometer. As a result, the convex probe using low frequency showed a higher temperature increase than the linear probe using high frequency, so there was a significant difference, and the temperature increase was the highest on the surface, and the depth of 1cm showed a temporary temperature increase, but there was no significant temperature change. There was no change in the deep temperature of 5 cm to 15 cm, and the TI and MI values did not change during the test time. Since only the surface temperature rose during the 15-minute test and there was no temperature change in the core, so it is not expected to show a temperature change that is harmful to the human body. However, it is thought that prolonged examination of one area may cause temperature rise, so it should be avoided.

The study on Development and characteristic of ultrasound biopsy training phantom of breast (유방 초음파 팬텀의 제작과 특성에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Ahn, Young-Man
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.19-24
    • /
    • 2003
  • We carried out studies on development and characteristic of ultrasound brast training biopsy phantom. the major finding were of follow ; (1) C type TMM was shown good homogeneity, brightness and attenuation as like human soft tissue. (2) $TiO_2$ 4.10%w/v TMM was shown good homogeneous echo texture and propagated speed as like the human Tissue. (3) $TiO_2$ type TMM was appeared lower brightness and higher penetration rate than C type TMM. Therefor, Breast TM phantom and target material TMM will be useful $TiO_2$ 4.10 %w/v TMM and C 2.09 %w/v TMM.

  • PDF

Manufacture of Flow Phantom with Stenosis and Imaging Evaluation of Power Doppler (혈관협착팬텀의 제작 및 파워도플러의 영상 평가)

  • Park, Hee-Young;Bae, Jong-Rim;Kim, Jeong-Koo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.8
    • /
    • pp.732-739
    • /
    • 2009
  • Flow phantom with stenosis was manufactured using an auto-injector to obtain angiostenotic flow information and quality assurance (QA) for ultrasound diagnostic instrumentation. Effectiveness of manufactured flow phantom with stenosis was investigated with power Doppler that was known to have diagnostic efficiency for angiostenosis. The flow phantom with stenosis was manufactured to 70% stenosis with 8 mm and 2.4 mm silicon tube, and silicone tube was covered with gelatin that has acoustic characteristics similar to soft tissue. When the linear transducer was used for measurement, the estimated diameter of normal vessel was measured lower than that of normal value, and the estimated diameter of stenosed vessel was measured higher than that of normal value. The measured parameters were not affected except for the radical conditions such as gain of 60%, PRF of 3000 Hz, use of maximal filter or angle. In addition, when the convex transducer was used for measurement, measurement parameters were affected by gain, PRF, filter, and angle. Therefore it is expected that flow phantom with stenosis manufactured with an auto-injector will be utilized effectively for QA of angiostenotic diagnosis.

Making Human Phantom for X-ray Practice with 3D Printing (3D 프린팅을 활용한 일반 X선 촬영 실습용 인체 팬텀 제작)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.371-377
    • /
    • 2017
  • General phantom for practical X-ray photography Practical phantom is an indispensable textbook for radiology, but it is difficult for existing commercially available phantom to be equipped with various kinds of phantom because it is an expensive import. Using 3D printing technology, I would like to make the general phantom for practical X-ray photography less expensive and easier. We would like to use a skeleton model that was produced based on CT image data using a 3D printer of FDM (Fused Deposition Modeling) method as a phantom for general X-ray imaging. 3D slicer 4.7.0 program is used to convert CT DICOM image data into STL file, convert it to G-code conversion process, output it to 3D printer, and create skeleton model. The phantom of the completed phantom was photographed by X - ray and CT, and compared with actual medical images and phantoms on the market, there was a detailed difference between actual medical images and bone density, but it could be utilized as a practical phantom. 3D phonemes that can be used for general X-ray practice can be manufactured at low cost by utilizing 3D printers which are low cost and distributed and free 3D slicer program for research. According to the future diversification and research of 3D printing technology, it will be possible to apply to various fields such as health education and medical service.

Microwave Radiometry for functional Diagnosis of Biological tissue (생체 기능적 진단을 위한 Microwave Radiometry의 응용)

  • Lee, J.W.;Kim, K.S.;Lee, S.M.;Yoon, G.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.845-847
    • /
    • 2000
  • 깊은 생체 조직에서 전자기 에너지의 일부가 피부로 전달되는데, 이때 생체 내부에서 피부로 전달되는 전자기 에너지의 세기는, 주파수 대역과 전자기파를 흡수, 반사, 투과시키는 인체의 매질에 따라 다르다. Microwave Radiometry는 인체 내부 조직에서 방출되는 1-6 GHz 대역의 전자기 에너지 일부를 피부 표면에서 측정하여 일정한 체적내의 인체 내부 온도 평균온도를 추정하는 방법이다. 이러한 Radiometry로 암이나 종양 등의 이상 조직을 진단하는 의학적 가설은, 암이 진행시 악성 종양의 세포의 신진대사가 정상 세포보다 활발하게 되고 또한 종양 세포 주위로 혈액의 유입이 증가하게되어, 주위의 정상 세포 보다 열을 보다 더 방출하는 데 있다. 이때 발생된 열은 일정한 주파수 대역의 마이크로파 에너지를 방출하게 되고, 이에 Radiometry로 인체에 무해하고(passive), 비침습적(non-invasive), 방사능의 영향이 없는 (non-ionizing) 방법으로 인체 내부에서 전달되는 전자기 에너지 강도를 측정하여 종양 부위와 주위 정상부위의 온도 차이를 추정 의학진단에 응용할 수 있다. 본 논문에서는 이러한 Microwave Radiometry의 의학적 응용과 생리학적 특성을 고려한 인체모델용 팬텀에 대하여 살펴본다.

  • PDF