• Title/Summary/Keyword: 인장 시험

Search Result 1,947, Processing Time 0.027 seconds

Development of a Fatigue Testing System for Micro-Specimens (마이크로시험편용 피로시험기 개발)

  • Kim, Chung-Youb;Sharpe, W.N.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.9
    • /
    • pp.1201-1207
    • /
    • 2010
  • In this study, a fatigue testing system capable of performing load-controlled tension-tension tests for micro-specimens was developed by using an electro-magnetic actuator. Using this system, fatigue testing as well as tensile testing can be performed over a wide range of loading frequencies. Further, a new laser interferometric strain/displacement gage was used during fatigue testing to obtain high-resolution measurements of the cyclic deformation of thin films. Since the testing machine and the displacement gage are stable and show quick responses, the displacement can be measured instantaneously and continuously during fatigue testing, and high-resolution results can be obtained.

Change of Strength of High-Strength Bolted Connection Depending on Standard and Over Bolt Hole (표준공과 과대공을 갖는 고장력볼트 접합부의 강도변화)

  • Yang, Seung-Hyun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.5
    • /
    • pp.605-612
    • /
    • 2012
  • A tension member that has a high-strength bolt fastened to a standard bolt hole increases structural resistance but causes problems from workability or economic perspectives. In this research, a total of 28 samples that have standard and over bolt holes as the tension member's high-strength bolted connection were made and a tension test was conducted. The change of strength of the connection has been confirmed by comparing the tension load of standard and over bolt hole samples obtained from the test results with the design strength due to net section and end distance. Samples made with over bolt holes had a lighter tension load than that of samples made with standard bolt holes, exceeded the design strength of present design standards, and although decrease in strength was inevitable due to the over bolt hole, their safety was satisfactory.

Establishment of Failure Criteria of Repeated Direct Tensile Test to Evaluate Reflective Cracking Resistance of Asphalt Concrete Pavement (아스팔트 콘크리트 포장의 반사균열 저항성 평가를 위한 반복직접인장시험의 파괴기준 설정)

  • Lee, Bong Lim;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.1109-1116
    • /
    • 2016
  • There are various test methods for evaluating the reflective cracking resistance of asphalt concrete pavement. Repeated direct tensile test is cheap and simple compared to the other traditional experimental methods. Determination of failure criteria is needed to apply a repeated direct tensile test. Various methods were used to determine the number of failure of repeated direct tensile test. The number of failure was defined as the time to reach 10% of the initial load, this method can be satisfied with specified tolerance of 10%. When the thickness of specimen is increased to 50 mm from 30 mm, the failure number is increased by 13.6 times. Thus, this result shows that the thickness of pavement is a big influence on the reflective cracking resistance. Reflective cracking resistance of asphalt concrete is decreased according to the increase in opening displacement. The repeated direct tensile test can be used as a reflective cracking resistance factor in pavement design, because it can evaluate the reflective cracking resistance according to the pavement thickness, opening displacement, material properties etc.

Tensile Test Evaluation of Polypropylene Sheets Following as Strain Rate and Temperature Variation (폴리프로필렌의 변형속도 및 온도변화에 따른 판재 인장시험 평가)

  • Kim, Kee Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.32-36
    • /
    • 2018
  • A tensile test evaluation of a polypropylene plate was carried out using an Instron tester with a capacity of 500 kgf. To evaluate the strain rate sensitivity of the polypropylene plate with a thickness of 0.8 mm, a tensile test was performed at room temperature through strain rate variations from $5{\times}10^{-4}/sec$ to $5{\times}10^{-2}/sec$. From these, the changes in strength due to the strain rate change and temperature change were compared. As a result of the experiment, the strength increased with increasing initial strain rate. Polypropylene was found to be a material with a positive strain rate sensitivity. In addition, the high temperature tensile properties of the polypropylene plate were evaluated using high temperature tensile tests at 80, 120, and $160^{\circ}C$. The strength decreased with increasing temperature. In particular at $160^{\circ}C$, the tensile strength decreased to zero. The increase in yield strength and the tensile strength at room temperature, $80^{\circ}C$ and $120^{\circ}C$ were similar. At $160^{\circ}C$, however, there was almost no increase in strength because the stress approached zero. In the high temperature tensile test, the tensile strength increased more than the increase in yield strength with increasing strain rate.

A Comparative Study on the Tensile Strength of Frozen Soil according to Test Methods (시험 방법에 따른 동결토의 인장강도)

  • Seo, Young-Kyo;Kang, Hyo-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.4
    • /
    • pp.57-66
    • /
    • 2008
  • In this study, the blast-induced vibration effects on the structural stability of the adjacent tunnel and the stability were estimated with respect to the allowable peak particle velocity (PPV). The blasting distance from the tunnel satisfying the allowable PPV was estimated based on the analytical solutions, United States Bureau of Mines (USBM) suggestions, and the equations used in the subway in Seoul. The allowable blasting distance was estimated by using finite difference analysis (FDA) and the behavior of the concrete lining and rock bolts was examined and the stability of those was estimated during the blast. Research results show that the blast-induced vibration effects on the structural stability are negligible for the concrete lining but relatively large for the rock bolts.

Measurement of Retaining Tensile Load with the Relative Displacement Detector of Ground Anchors (상대변위측정기를 이용한 지반앵커의 보유인장력 측정)

  • Jeong, Hyeon-Sik;Han, Kwang-Suk;Lee, Yeong-Saeng
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.10
    • /
    • pp.59-69
    • /
    • 2017
  • The tension load of the ground anchor inserted in the ground gradually changes over time. In this regard the change of the initial tension load is primarily decreased by the fixation condition of the fixing head and the mechanical characteristics of the tensile material. The subsequent additional tension load is a time-dependent loss mostly due to the fixing conditions of the bonded length and the surrounding ground properties of the field. In this paper, therefore, a measurement system using a relative displacement detector that can relatively easily measure the change of tension load is discussed. As a result of the review, it was confirmed that the results using the relative displacement detector are similar to those of the real scale model test, and it was also confirmed that similar results were obtained with the result of the pull-out test conducted on the ground anchors fixed to weathered rocks condition. In addition, a pull-out test was conducted on the test anchors whose initial tension load loss was relatively large and through this test pull-out behavior of the tension type ground anchors was verified.

발전 설비의 가동 중 신뢰성 평가를 위한 연속압입시험법의 활용

  • Song, Won-Seok;Gang, Seung-Gyun;Kim, Yeong-Cheon;Kwon, Dong-Il
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.125-130
    • /
    • 2011
  • 발전 설비는 기대 수명동안의 안정성을 확보하기 위하여 해당 규격에 부합하도록 설계하여 건설된다. 하지만 가동 중 다양한 복합 환경에 노출됨에 따라 구조물을 이루고 있는 재료의 열화 현상이 가속화되어 예기치 못한 파손이 발생할 수 있다. 기계적 물성은 재료의 기계적 거동을 나타내는 주요 척도가 되며 이는 신뢰성 및 안전과 직결된다. 하지만 기존의 역학물성을 측정하는 대부분의 시험법들은 특정 크기의 시편을 요구하고 파괴적인 시험법이기 때문에 가동 중 시설물에 적용하기가 불가능하였다. 이러한 한계점을 극복하고자 비파괴적이고 정량적인 시험이 가능한 연속압입시험법이 최근 각광받는 시험법으로서 많은 연구자들에 의해 연구되고 있다. 이 시험법은 시험 대상물의 형상에 제약을 받지 않으며 시험 절차가 매우 간단하다는 장점을 가진다. 또한 대상의 국소 부위에 시험할 수 있어 취약 부위 판별이 가능하다. 본 연구에서는 대표응력-대표변형률 기법을 통하여 인장물성을 평가하고, 압입 하중 차이를 이용하여 소재에 존재하는 잔류응력을 평가하는 기법을 소개한다. 또한, 연속압입시험을 이용하여 실제 발전소 파이프의 취약부위로 알려진 용접부에 대하여 인장물성 및 잔류응력을 측정함으로써 실제 산업체의 신뢰성 평가가 적용할 수 있음을 확인하였다.

  • PDF

Infrared Thermographic Monitoring for Failure Characterization in Railway Axle Materials (철도차량 차축 재료의 파괴특성 적외선열화상 모니터링)

  • Kim, Jeong-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.2
    • /
    • pp.116-120
    • /
    • 2010
  • The wheelset, an assembly of wheel and axle, is one of important parts in railway bogie, directly related with the running safety of railway rolling stock. In this investigation, the tensile failure behavior of railway axle materials was investigated. The tensile coupons were prepared from the actual rolling stock parts, which were operated over 20 years. The tensile testing was performed according to the KS guideline. During tensile testing, an infrared camera was employed to monitor temperature changes in specimen as well as demonstrate temperature contour in terms of infrared thermographic images. The thermographic images of tensile specimens showed comparable results with mechanical behavior of tensile materials. In this paper, the failure mode and behavior of railway axle materials were provided with the aid of infrared thermography technique.

Influence of Rock Inhomogeneity on the Static Tensile Strength of Rock (암석의 정적 인장강도에 미치는 불균질성의 영향)

  • Cho, Sang-Ho;Yang, Hyung-Sik;Katsuhiko Kaneko
    • Tunnel and Underground Space
    • /
    • v.13 no.2
    • /
    • pp.117-124
    • /
    • 2003
  • The fracture processes under static tensile loading were simulated using a proposed numerical simulation method, based on finite element method and fracture mechanism, and analyzed to verify an influence of rock inhomogeneity on static tensile strength. Static tensile strengths for the specimen models with different spatial microscopic tensile strength when m=5 and m=50 were estimated. These analyses revealed that the static tensile strength becomes closer to the mean microscopic tensile strength at a higher uniformity coefficient and the scatter of the strength data decreases in increasing the uniformity coefficients. Therefore, it could be concluded that rock inhomogeneity has an effect on static tensile strength.

Experimental Investigations on Tensile Strength of Sand at Low Moisture Contents (저함수비 모래의 인장강도에 대한 실험적 연구)

  • Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.23-31
    • /
    • 2002
  • This study shows that tensile strength in moist sand clearly exists due to moisture and it is possible to simply and accurately measure the tensile strength of sands at low moisture contents. These measurements were made through the use of a newly developed direct tension apparatus and technique which are able to produce highly accurate results. The magnitudes of the tensile strengths of these moist and relatively clean sands are not equal to zero, as is widely assumed. Tensile strength increases with increasing moisture content and this trend is more noticeable at increasing relative densities. The influence of tensile strength in geotechnical problems was also examined by considering a simple rigid circular footing in sandy soil. It clearly shows that a small amount of tensile strength can significantly enhance the stability of a geotechnical system.