• Title/Summary/Keyword: 인장부재

Search Result 423, Processing Time 0.025 seconds

Influence of Tension Stiffening Effect on Deflection and Crack Width in RC Members (철근콘크리트 부재의 처짐과 균열폭에 대한 인장증강효과의 영향)

  • Choi, Seung-Won;Yang, Jun-Ho;Kim, Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.6
    • /
    • pp.761-768
    • /
    • 2010
  • When cracks occur in reinforced concrete structures, a steel carries all tensile force at crack section, while the concrete between cracks carries a part of the tensile force due to bond, so that the steel is less elongated. This is called the tension-stiffening effect, that plays an important role in verification of a serviceability limit state. But it is a complicated work to use a complex strain distribution between cracks, therefore an average strain is used to calculate deflection and crack width. In Eurocode 2, tension-stiffening effect expressed in the first order form or the second order form is used in calculating an average curvature for deflection. In this study for a flexural member deflection and crack width are calculated using various models for the tension-stiffening effect and the results are compared with the values of Eurocode 2 and KCI provisions. As results, the predicted values using the second order form are appeared to be well agreed with the experimental values and it could secure more analytical consistency.

Tensile Properties of Metal Plate Connector in Domestic Softwood Lumber (국산 침엽수 철물접합부의 인장하중 특성)

  • Shim, Kug-Bo;Park, Jung-Hwan;Lee, June-Ho
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.96-103
    • /
    • 2003
  • This study was conducted to evaluate the tensile properties of metal plate connector for the domestic major softwoods, such as Korean red pine, Korean white pine, and Japanese larch. The maximum tensile load of Korean red pine was 3,612kgf in AA type, it was 1.2 and 1.7 times higher load than that of Japanese larch and Korean white pine. In EA type, it was 2,704kgf, and 1.1 and 1.5 times higher than the loads of Japanese larch and Korean white pine. The failure modes of metal plate connector were metal plate withdrawal, plate tensile failure, and wood shear block failure. The failure mode of Korean red pine connector was tensile failure of plate, that is reason of the high tensile load resistance for metal plate connections in Korean red pine. The mechanical properties of metal plate connector could be predicted by the Foschi model parameter. In the initial stage, the Korean red pine connector was stiffer than the other species. The design values for metal plate connector per tooth was 25, 22, and 15kgf for Korean red pine, Japanese larch, and Korean white pine in AA type and 19, 17, and 13kgf in EA type.

Vibrations of a Fluid-filled Thick Cylindrical Shel with Embedded Internal Strength Members (길이 방향 내심 장력재를 갖는 유체 충진된 두꺼운 원통 셀의 진동 해석)

  • 함일배;정의봉;이헌곤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.340-343
    • /
    • 1995
  • 본 연구에서는 내심형 장력재가 셀 벽속에 묻혀 있는 경우에, 셀의 진동 및 내부 음압을 셀과 장력부재 그리고 내부 충진유체들의 상호 작용을 고려하여 계산하였다. 계산 결과, 셀 재료와 인장 부재의 탄성계수, 감쇠특성의 차이에 따라 응답이 변화함을 확인할 수 있었으며, 각각의 재료 특성 및 설계 변수들에 대한 추가 연구를 수행하여, 내심형 장력 부재를 갖는 유체 충진 원통형 셀의 진동 전달 특성 해석 및 최적화 설계에 이 연구 결과들을 적용할 수 있을 것으로 판단된다.

  • PDF

Flexural and Tensile Performance of Strain-Hardening Cement Composite with Synthetic Fibers (합성섬유를 사용한 변형경화형 시멘트 복합체의 휨 및 인장성능)

  • Kim, Sun-Woo;Lee, Min-Jung;Jang, Yong-Heon;Jang, Gwang-Soo;Song, Seon-Hwa;Yun, Hyun-Do
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.925-928
    • /
    • 2008
  • Fiber is an important ingredient in strain-hardening cementitious composite (SHCC), which can control fracture of cementitious composite by bridging action. The properties of reinforcing fiber, as tensile strength, aspect ratio and elastic modulus, have great effect on the fracture behavior of SHCC. To apply SHCC to structural member, SHCC must have economical efficiency and workability as well as own excellent tensile performance. For these purposes, four-point bending and direct tensile tests on SHCC with only hybrid synthetic fibers, total fiber volume fraction, $V_f$, is 1.5%, are carried out. The research emphasis is on the mechanical properties of SHCC made in Polyvinyl alcohol (PVA) and Polyethylene (PE) fibers, and how this affects the composite property, and ultimately its strain-hardening performance. Also, effect of hybrid type and water-cement ratio on the behavior of SHCC was evaluated in this paper.

  • PDF

Study on Obstacle Deflector of a Railway Vehicle Using Tension-type Energy Absorbers (인장형 에너지흡수부재를 이용한 철도차량용 장애물제거기 연구)

  • Kim, Hongeik;Kim, Jinsung;Kwon, Taesoo;Jung, Hyunseung
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.173-181
    • /
    • 2017
  • The obstacle deflector sweeps obstacles off the track or absorbs crash energy with an energy absorber to prevent derailment of a train and to minimize damage and casualties after an accident. In this study, an obstacle deflector and its operational mechanism were designed with a tension-type energy absorber and a 4-bar linkage system. Also, a test method was suggested and verified with FEA (Finite Element Analysis) and UTM (Universal Test Machine) for testing of the static load and energy absorbing ability according to EN 15227 regulations. Through this study, an obstacle deflector that meets the EN 15227 standard was designed and a test method was suggested to adjust the collapse load easily and to verify it experimentally according to the design and verification procedure of the obstacle deflector.

An Experimental Study on the Behavior of Curved Panel Parts Using Composite Materials (복합소재를 활용한 곡면 패널의 부재단위 성능 평가)

  • Park, Hee Beom;Park, Jong-Sup;Kang, Jae-Yoon;Jung, Woo-Tai
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.7
    • /
    • pp.474-480
    • /
    • 2018
  • FRP is a new material that is lightweight, has high strength and high durability, and is emerging as a third construction material in many countries. The composite material panel targeted in this study was a curved member and is the most frequently used arch-shaped member of a structures, such as tunnels. Composite curved panels can be produced in high quality and large quantities through automation operations. On the other hand, the frequency of application is low, and the design criteria and experimental data are lacking. Therefore, this study examined the mechanical performance of the member unit first to verify its performance as structural members of the FRP curved panel. For this purpose, tensile, compression, and connection performance tests were carried out. The tensile tests showed greater tensile strength of specimens with larger curvature, and the compression tests showed that the composite section of a composite material has greater compressive strength than the concrete section. Finally, the test of the performance of the connection showed that the attachment performance of the connection was more than equal to that of the FRP composite material panel.

Unified Method for Nonlinear Finite Element Analysis of RC Planar Members (통합방법을 이용한 철근콘크리트부재의 비선형 유한요소해석)

  • 박홍근
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.2
    • /
    • pp.133-144
    • /
    • 1997
  • Concrete plasticity models fol the analysis of reinforced concrete members in plane stress are studied. The proposed plasticity model for reinforced concrete provides a unified approach combining plasticity theory and damage models. It addresses strength mhancement under rnultiaxial compression. and tensile cracking damage. The model uses multiple failure criteria for compressive crushing and tensile cracking. For tensile cracking behavior. rotating-crack and fixed-crack plasticity models are compared. As crushing failure criterion, the Drucker-Prager and the von Mises models are used for comparison. The model uses now and existing damnge models fbr tension softening, tension stiffening. and compression softening dup to tensilt. cracking. Finite element analyses using the unified method are compatxd with existing rxpcrimcntal r.esults. To vei.ify the proposcd crushing and cracking plasticity models, the experiments have load capacities govc11.nc.d either by compressive crushing of'concrete or by yi~lding of' reinforcing steel.

An Experinmental Study on Characteristic Analysis of Durability which follows in temperature for FRP Modular Box Member (온도변화에 따른 FRP 모듈형 박스 부재의 내구성 파악을 위한 실험적 연구)

  • Kwak, Kae-Hwan;Kim, Woo-Jong;Yang, Dong-Oun;Kim, Ho-Sun
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.251-254
    • /
    • 2009
  • 건설 분야에서 FRP(Fiber Reinforced Polymers) 부재는 기존의 건설부재에 비해 많은 장점을 가지고 있어 여러 분야에서 연구 및 개발이 이루어지고 있다. 그중 FRP 재료를 이용한 교량 부재들이 해외 뿐만 아니라 국내에서도 연구되고 있으며, FRP 인장재 및 바닥판은 연구 및 개발이 완료돼 현재 시공 중에 있고 FRP 휨 부재 또한 연구가 활발히 진행되고 있다. 이런 FRP 부재는 외부 환경에 그대로 노출됨으로써, 온도 등의 주위 환경의 변화에 많은 영향을 받게 되며, 특히 높은 온도에 취약한 성질을 가지고 있다. 이에 본 연구에서는 FRP 부재의 온도에 따른 역학적 특성을 파악하기위한 실험적 연구로써, $-21^{\circ}C$, $100^{\circ}C$, $200^{\circ}C$에 각각 1시간씩 시험체를 보관한 뒤 내구성 실험을 실시하였다. 각각의 시험체는 FRP 모듈형 박스부재에서 4개씩 채취하였으며, 실험 실시 후 SEM촬영을 실시하여 파괴모드를 분석하였다. 실험 결과 저온일 때는 강도변화가 많이 나타나지 않았으나 고온일 때 압축 및 휨강도의 급격한 저조를 확인할 수 있었다. 고온 보관 시험체의 SEM(Scanning Electron Microscope) 촬영결과 수지의 손상으로 낮은 강도가 측정되는 것을 확인할 수 있었다.

  • PDF

A Unified Model of Strain Localization in Concrete (콘크리트 변형률 국소화의 통일된 모형)

  • 송하원;김인순
    • Magazine of the Korea Concrete Institute
    • /
    • v.9 no.5
    • /
    • pp.115-125
    • /
    • 1997
  • 콘크리트의 변형률국소화는 콘크리트의연화거동에 수반되어 변형이 국부적으로 집중되는 현상이다. 본 연구의 목적은 인장과 압축하중상태에서 콘크리트 부재에 발생하는 콘크리트 변형률 국소화 거동을 해석적으로 재현할 수 있는 통일된 모형을 제안하는 것이다. 본 논문에서는 인장과 압축에 대하여 변형률국소화가 일어나는 콘크리트 부재를 변형률 연화가 일어나는 국소화영역과 탄성제하가 발생하는 비국소화영역으로 구분하여 모델링하는 통일된 모형을 제안하였다. 또한 제안된 모형에서 미시역학적 평균화기법을 이용해 평균등가탄성계수와 수정된 평균등가탄성계수를 구하여 시편의 크기와 국소화영역의 크기에 따는 해석을 수행하였으며 기존의 실험값과 비교하였다. 연구결과, 본 연구에서의 변형률국소화모형이 크기효과를 포함한 콘크리트의 변형률국소화거동 해석에 타당하게 적용될 수 있음을 보여주었다.

Advanced Idealized Structural Units Considering the Excessive Tension-Deformation Effects (과도 인장변형효과를 고려한 개선된 이상화구조요소)

  • Jeom-K. Paik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.3
    • /
    • pp.100-115
    • /
    • 1993
  • In this paper, the extent of use of three kinds of the existing idealized structural units, namely the idealized beam-column unit, the idealized unstiffened plate unit and the idealized stiffened plate unit, is expanded to deal with the excessive tension-deformation effects, in which a simplified mechanical model for the stress-strain relation of steel members under tensile load is suggested. The 1/3-scale hull model for a leander class frigate under sagging moment tested by Dow is analyzed, and it is shown that the excessive tension-de-formation is a significant factor affecting the progressive collapse behavior, particularly in the post-collapse range.

  • PDF