• Title/Summary/Keyword: 인자 최적화

Search Result 686, Processing Time 0.023 seconds

A Comparison between Multiple Satellite AOD Products Using AERONET Sun Photometer Observations in South Korea: Case Study of MODIS,VIIRS, Himawari-8, and Sentinel-3 (우리나라에서 AERONET 태양광도계 자료를 이용한 다종위성 AOD 산출물 비교평가: MODIS, VIIRS, Himawari-8, Sentinel-3의 사례연구)

  • Kim, Seoyeon;Jeong, Yemin;Youn, Youjeong;Cho, Subin;Kang, Jonggu;Kim, Geunah;Lee, Yangwon
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.3
    • /
    • pp.543-557
    • /
    • 2021
  • Because aerosols have different spectral characteristics according to the size and composition of the particle and to the satellite sensors, a comparative analysis of aerosol products from various satellite sensors is required. In South Korea, however, a comprehensive study for the comparison of various official satellite AOD (Aerosol Optical Depth) products for a long period is not easily found. In this paper, we aimed to assess the performance of the AOD products from MODIS (Moderate Resolution Imaging Spectroradiometer), VIIRS (Visible Infrared Imaging Radiometer Suite), Himawari-8, and Sentinel-3 by referring to the AERONET (Aerosol Robotic Network) sun photometer observations for the period between January 2015 and December 2019. Seasonal and geographical characteristics of the accuracy of satellite AOD were also analyzed. The MODIS products, which were accumulated for a long time and optimized by the new MAIAC (Multiangle Implementation of Atmospheric Correction) algorithm, showed the best accuracy (CC=0.836) and were followed by the products from VIIRS and Himawari-8. On the other hand, Sentinel-3 AOD did not appear to have a good quality because it was recently launched and not sufficiently optimized yet, according to ESA (European Space Agency). The AOD of MODIS, VIIRS, and Himawari-8 did not show a significant difference in accuracy according to season and to urban vs. non-urban regions, but the mixed pixel problem was partly found in a few coastal regions. Because AOD is an essential component for atmospheric correction, the result of this study can be a reference to the future work for the atmospheric correction for the Korean CAS (Compact Advanced Satellite) series.

Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose (유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사)

  • Park, Hye-Suk;Kim, Ye-Seul;Kim, Sang-Tae;Park, Ok-Seob;Jeon, Chang-Woo;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.163-171
    • /
    • 2011
  • The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kVp in 10 kVp increments at the FDD of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at the same effective dose. The results showed that the eDQE was largest at 60 kVp when compares the eDQE at different tube voltage. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF). However, most of major hospitals in Korea employed a short FDD of 100 cm with an anti-scatter grid for the chest radiological examination of a 15 month old infant. As a result, the entrance surface air kerma (ESAK) values for the hospitals of this survey exceeded the Korean DRL (diagnostic reference level) of $100{\mu}Gy$. Therefore, appropriate technical parameters should be established to perform pediatric chest examinations on children of different ages. The results of this study may serve as a baseline to establish detailed reference level of pediatric dose for different ages.

A Study on Characteristics of Lincomycin Degradation by Optimized TiO2/HAP/Ge Composite using Mixture Analysis (혼합물분석을 통해 최적화된 TiO2/HAP/Ge 촉매를 이용한 Lincomycin 제거특성 연구)

  • Kim, Dongwoo;Chang, Soonwoong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • In this study, it was found that determined the photocatalytic degradation of antibiotics (lincomycin, LM) with various catalyst composite of titanium dioxide ($TiO_2$), hydroxyapatite (HAP) and germanium (Ge) under UV-A irradiation. At first, various type of complex catalysts were investigated to compare the enhanced photocatalytic potential. It was observed that in order to obtain the removal efficiencies were $TiO_2/HAP/Ge$ > $TiO_2/Ge$ > $TiO_2/HAP$. The composition of $TiO_2/HAP/Ge$ using a statistical approach based on mixture analysis design, one of response surface method was investigated. The independent variables of $TiO_2$ ($X_1$), HAP ($X_2$) and Ge ($X_3$) which consisted of 6 condition in each variables was set up to determine the effects on LM ($Y_1$) and TOC ($Y_2$) degradation. Regression analysis on analysis of variance (ANOVA) showed significant p-value (p < 0.05) and high coefficients for determination value ($R^2$ of $Y_1=99.28%$ and $R^2$ of $Y_2=98.91%$). Contour plot and response curve showed that the effects of $TiO_2/HAP/Ge$ composition for LM degradation under UV-A irradiation. And the estimated optimal composition for TOC removal ($Y_2$) were $X_1=0.6913$, $X_2=0.2313$ and $X_3=0.0756$ by coded value. By comparison with actual applications, the experimental results were found to be in good agreement with the model's predictions, with mean results for LM and TOC removal of 99.2% and 49.3%, respectively.

A Study of the Effect of the Permeability and Selectivity on the Performance of Membrane System Design (분리막 투과도와 분리도 인자의 시스템 설계 효과 연구)

  • Shin, Mi-Soo;Jang, Dongsoon;Lee, Yongguk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.656-661
    • /
    • 2016
  • Manufacturing membrane materials with high selectivity and permeability is quite desirable but practically not possible, since the permeability and selectivity are usually inversely proportional. From the viewpoint of reducing the cost of $CO_2$ capture, module performance is even more important than the performance of membrane materials itself, which is affected by the permeance of the membrane (P, stagecut) and selectivity (S). As a typical example, when the mixture with a composition of 13% $CO_2$ and 87% of $N_2$ is fed into the module with 10% stage cut and selectivity 5, in the 10 parts of the permeate, $CO_2$ represents 4.28 parts and $N_2$ represents 5.72 parts. In this case, the $CO_2$ concentration in the permeate is 42.8% and the recovery rate of $CO_2$ in this first separation appears as 4.28/13 = 32.9%. When permeance and selectivity are doubled, however, from 10% to 20% and from 5 to 10, respectively, the $CO_2$ concentration in the permeant becomes 64.5% and the recovery rate is 12.9/13 = 99.2%. Since in this case, most of the $CO_2$ is separated, this may be the ideal condition. For a given feed concentration, the $CO_2$ concentration in the separated gas decreases if permeance is larger than the threshold value for complete recovery at a given selectivity. Conversely, for a given permeance, increasing the selectivity over the threshold value does not improve the process further. For a given initial feed gas concentration, if permeance or selectivity is larger than that required for the complete separation of $CO_2$, the process becomes less efficient. From all these considerations, we can see that there exists an optimum design for a given set of conditions.

Optimization of Total Arc Degree for Stereotactic Radiotherapy by Using Integral Biologically Effective Dose and Irradiated Volume (정위방사선치료 시 적분 생물학적 유효선량 및 방사선조사용적을 이용한 Total Arc Degree의 최적화)

  • Lim Do Hoon;Lee Myung Za;Chun Ha Chung;Kim Dae Yong
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.199-204
    • /
    • 2001
  • Purpoe : To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. Methods and Materials : With Xknife-3 planning system & 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, $100^{\circ},\;200^{\circ},\;300^{\circ},\;400^{\circ}C,\;500^{\circ},\;600^{\circ}$ or total arc degrees, and $30^{\circ}\;or\;45^{\circ}$ or arc intervals were used. After the completion of planning, the plans were compared each other using $V_{50}$ (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. Results : At $30^{\circ}$ of arc interval, the values of $V_{50}$ had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 arc interval, up to $400^{\circ}$ of total arc degree, the values of $ V_{50}$ decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. At $30^{\circ}$ of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At $45^{\circ}$ arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with n and n mm or collimator diameters, up to $400^{\circ}$ or total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at $500^{\circ}\;and\;600^{\circ}$ of total arc degrees, the values increased. Conclusion : In the stereotactic radiotherapy planning for brain lesions, planning with $400^{\circ}$ of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of $500^{\circ}\;and\;600^{\circ}$ of total arc degrees make the increase of$V_{50}$ and integral biologically effective dose. Therefore stereotactic radiotherapy planning using $400^{\circ}$ of total arc degree can increase the therapeutic ratio and produce the effective outcome in the management of personal and mechanical sources in radiotherapy department.

  • PDF

Summer Hydrographic Features of the East Sea Analyzed by the Optimum Multiparameter Method (OMP 방법으로 분석한 하계 동해의 수계 특성)

  • Kim, Il-Nam;Lee, Tong-Sup
    • Ocean and Polar Research
    • /
    • v.26 no.4
    • /
    • pp.581-594
    • /
    • 2004
  • CREAHS II carried out an intensive hydrographic survey covering almost entire East Sea in 1999. Hydrographic data from total 203 stations were released to public on the internee. This paper summarized the results of water mass analysis by OHP (Optimum Multiparameter) method that utilizes temperature, salinity, dissolved oxygen, pH, alkalinity, silicate, nitrate, phosphate and location data as an input data-matrix. A total of eight source water types are identified in the East Sea: four in surface waters(North Korea Surface Water, Tatar Surface Cold Water, East Korean Coastal Water, Modified Tsushima Surface Water), two intermediate water types (Tsushima Middle Water, Liman Cold Water), two deep water types (East Sea Intermediate Water, East Sea Proper Water). Of these NKSW, MTSW and TSCW are the newly reported as the source water type. Distribution of each water types reveals several few interesting hydrographic features. A few noteworthy are summarized as follows: The Tsushima Warm Current enter the East Sea as three branches; East Korea Coastal Water propagates north along the coast around $38^{\circ}N$ then turns to northeastward to $42^{\circ}N$ and moves eastward. Cold waters of northern origin move southward along the coast at the subsurface, which existence the existence of a circulation cell at the intermediate depth of the East Sea. The estimated volume of each water types inferred from the OMP results show that the deep waters (ESIW + ESPW) fill up ca. 90% of the East Sea basins. Consequently the formation and circulation of deep waters are the key factors controlling environmental condition of the East Sea.

A Study on Characterization of Formation and Reduction of THMs in Water Treatment Process (정수처리공정별 THMs 발생특성과 저감방안에 대한 연구)

  • Ka, Gil-Hyun;Bae, Min-Ho;Lee, Jun-Ho;Ahn, Chi-Hwa;Han, Ihn-Sup;Min, Byung-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.7
    • /
    • pp.721-728
    • /
    • 2008
  • DBPs(Disinfection By-Products) are most formed through the reactions between chlorine and NOM(Natural Organic Matter) in water treatment. In this study, occurrence of DBPs including THMs(Trihalomethanes) is evaluated. Also, influencing factors by the seasons and raw water quality were investigated for correlation among them and the characteristics of THMs formation by prechlorination process. This study investigated the operation condition for THMs removal depending on raw water quality. Water treatment plant from intake station to gauging well flows for about 10 hours in Y Water Supply Office. It is limited to control of THMs formation because of excessive reaction time between chlorine and THMs precursors in the intake station. Therefore, as multi-points prechlorination from intake station to gauging well, THMs formation was decreased in the water treatment, and it was willing to prevent overdosage of chlorine. The concentration of THMs was 0.021 mg/L in the summer, 0.015 mg/L in the winter, respectively. Also, THMs formation showed that 0.013 mg/L in the water of gauging well after prechlorination, 0.014 mg/L in the flocculation/sedimentation/filtration, 0.016 mg/L in the water after postchlorination, respectively. THMFP(Trihalomethane Formation Potential) removed 42.7% and 50% through the flocculation/sedimentation and filtration, respectively, and it is similar TOC removal efficiency. In this study, multi-points prechlorination from intake station to gauging well decreases in contact time and concencrations of NOM and chlorine. Also, it decreases in THMs and amount of chlorine uesd. In the result of multi-points prechlorination in the summer, the concentration of THMs was 0.013mg/L in the treated water. In view of these facts, THMs formation can be decreased approximately 50%.

Development of RGD peptides grafted onto chitosan surfaces; Osteoblast interactions (RGD 펩타이드로 표면개질된 키토산막의 생물학적 영향)

  • Lee, Chang-Kyun;Hwang, Jeong-Hyo;Lee, Yong-Moo;Ku, Young;Rhyu, In-Chul;Lee, Seung-Jin;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.1
    • /
    • pp.27-35
    • /
    • 2003
  • 1. 목적 생체재료의 생체친화성을 증진시키고 치유를 촉진하기 위한 목적으로 생체재료의 생화학적 표면개질에 관한 연구가 널리 진행되고 있다. 이와 같은 목적으로 이용되어 온 부착분자에는 아미노산, 펩타이드, 단백질, 효소 및 성장인자들을 들 수 있으며, 이들 분자들을 금속, 골대체물질 및 폴리머와 같은 생체재료의 표면개질에 이용하여 왔다. 이 연구의 목적은 생체적합성이 우수하고 생분해성을 지닌 키토산으로 얇은 막을 제작한 후, 세포외 기질의 구성성분 중 세포부착에 관여하는 RGD 펩타이드를 부착시킨, 표면개질 키토산막의 생물학적 영향을 MG-63 조골양세포를 이용하여 관찰하는 것이다. 2. 방법 2% acetic acid에 키토산 가루를 녹여 만든 2% 키토산 용액으로 24-well 배양접시의 표면을 도포 후 24시간 동안 건조시켜 키토산막을 제작하였다. GRGDS 펩타이드를 cross-linker(EDC, NHS) (Sigma, MO, USA) 용액과 반응시켜서 펩타이드의 카르복실기를 활성화시켰다. 이들을 PBS 완충용액으로 수화시킨 키토산막과 결합시켜 펩타이드의 활성화된 카르복실기와 키토산의 아민기 간에 안정적인 아미드 결합(amide bond)이 형성되도록 하였다. 하루 동안 반응을 일으킨 후 PBS 완충용액과 증류수로 씻어내고 냉동 건조시킴으로써 GRGDS가 결합된 키토산막을 제작하였다. 재료 표면의 화학 성분을 알아보는데 사용되는 방법의 일종인 X-ray photoelectron spectroscopy(XPS) 분석을 통하여 부착분자가 키토산막에 결합된 여부를 확인하였다. GRGDS 펩타이드에 요오드를 결합시킨 후, 이것을 키토산막에 공유 결합시키고 XPS를 통해 요오드가 재료 표면에서 검출되는지를 검사하였다. 요오드가 검출된다면 이것은 키토산막 표면에 실제로 GRGDS 펩타이드가 존재하는 것을 의미하게 된다. 표면개질된 키토산막에 사람조골양세포인 MG-63을 접종하여 이를 실험군으로 하였고, 표면이 개질 되지 않은 키토산막을 대조군으로 하였다. 세포부착의 최적화 농도를 확인하기 위하여 GRGDS를 0.01, 0.05, 0.1, 0.25, 0.5, 1.0mg/ml의 농도로 준비하였다. 배양 후 1일, 7일째에 각 well에서 trypsin EDTA를 이용하여 세포를 분리한 후, 이를 원심 분리하여 세포수측정기를 이용하여 부착 세포의 수를 측정하여 세포의 부착 정도를 비교하였다. 배양 2시간, 24시간 후 주사전자현미경을 이용하여 키토산막에 부착된 세포의 양상을 관찰하였다. 3. 결과 XPS를 통한 표면의 화학 성분 분석 결과 GRGDS 펩타이드를 결합시킨 키토산막에서 요오드가 검출되었으며 펩타이드를 부착하지 않은 대조군에서는 검출되지 않았다. 따라서 cross-linker를 이용한 펩타이드와 키토산막의 공유결합을 확인할 수 있었다. 세포 배양 후 1일째 부착된 세포 수를 측정한 결과 0.1mg/ml 이상의 GRGDS 펩타이드 농도로 공유 결합시킨 키토산막에서 부착 세포 수가 다른 농도에 비해 유의성 있게 많이 관찰되었다. 이 농도 이하에서는 대조군과 실험군간에 세포부착의 유의한 차이가 없었다. 따라서 주사전자현미경을 이용한 부착 세포의 양상에 관한 관찰은 0.1mg/ml 농도의 펩타이드를 이용하였다. 세포 배양 7일째, 부착된 세포 수 측정 결과 GRGDS의 농도에 따른 유의성 있는 차이가 없었으며, 실험군과 대조군간에도 유의성 있는 차이가 없었다. 주사전자현미경 관찰결과 2시간 및 24시간 배양된 실험군 모두에서 별모양의 세포들이 키토산막 표면에 편평하게 잘 부착되어 있으며 많은 위족이 발달된 소견을 보인 반면, 대조군에서는 원형 또는 다각형 모양의 세포들이 실험군에 비해 부착이 덜 되어있는 양상을 보였다. 이 연구를 통하여 기능성 펩타이드를 생체재료의 표면에 공유결합 시키는 방법을 확립할 수 있었으며, RGD 펩타이드의 공유결합으로 표면개질된 키토산막이 조골세포의 부착능을 증진시킬 수 있음을 확인하였다. 표면개질된 생체재료를 소, 중동물에 적용시켜 생체 내에서의 생물학적 영향을 평가할 필요가 있으며, 이 실험의 결과는 향후 다양한 기능성 부착분자를 선발, 고안하여 임플란트용 생체재료의 표면개질에 이용하는 이른바 모방생체재료분야에 널리 활용될 수 있을 것으로 생각된다.

A Study on Soil Washing for Diesel-contaminated Soil by using Decomposition of NaOH/H$_2$O$_2$ (디젤유로 오염된 토양의 NaOH/H$_2$O$_2$ 분해를 이용한 토양세척에 관한 연구)

  • Hwang, Jong-Hyun;Choi, Won-Joon;Kim, Min-Chul;Jung, Jong-Hyeon;Ha, Soo-Ho;Oh, Kwang-Joong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.10
    • /
    • pp.999-1005
    • /
    • 2008
  • The main reaction for soil washing with using sodium hydroxide(NaOH) and hydrogen peroxide(H$_2$O$_2$) was desorption and flotation of petrochemical contaminant by means of oxygen bubble. We found the rate of decomposition by rate constant according to various temperature. For the purpose of optimizing the operation factor, we examined the effect of concentration of NaOH and H$_2$O$_2$, washing time, and soil:water ratio. The rate of decomposition for H$_2$O$_2$ in liquid phase is the first order reaction by its concentration. The rate constant of k$_1$ was 0.9439 $\times$ exp(-1376.82/RT) when concentration of NaOH was lower than 0.1 M, and the rate constant of k$_2$ was 17.3588 $\times$ exp(-2320.06/RT) when it was higher than NaOH of 0.1 M. It found that NaOH was facilitated at the beyond of specific concentration. We confirmed the optimum concentration of NaOH/H$_2$O$_2$ by means of rate constants during soil washing. Also, the optimum conditions during soil washing were washing time of 15 min, soil : water ratio of 1 : 3, and NaOH/H$_2$O$_2$ concentration of 0.25 M/0.1 M.

Analysis of Environment Factors in Pleurotus eryngii Cultivation House of Permanent Frame Type Structure (영구형 큰느타리버섯 재배사의 환경요인 분석)

  • Yoon Yong-Cheol;Suh Won-Myung;Lee In-Bok
    • Journal of Bio-Environment Control
    • /
    • v.15 no.2
    • /
    • pp.125-137
    • /
    • 2006
  • Pleurotus eryngii is one of the most promising mushrooms produced on the domestic farms. The quality as well as quantity of Eryngii is sensitively affected by micro climate factors such as temperature, relative humidity, $CO_2$ concentration, and light intensity. To safely produce high-quality Eryngii all the yew round, it is required that the environmental factors be carefully controlled by well designed structures equipped with various facilities and control systems. At the commercial mushroom cultivation houses of permanent frame type (A, B), this study was carried out to find out reasonable range of each environmental factor and yield together with economic and safe structures influencing on the optimal productivity of Eryngii. This experiment was conducted for about two-year ken Nov. 2003 to Dec. 2005 in cultivation house. Ambient temperature during the experiment period was not predominantly different from that of a normal year. The capacity of the hot water boiler and the piping systems were not enough. Because the capacity of electric heater and air circulation were not enough, air temperatures in cultivation house before improvement of system were maintained somewhat lower than setting temperature, and maximum air temperature difference between the upper and lower growth stage during a heating time period was about 5.1. But the air temperatures after system improvement were maintained within the limits range of setting temperature without happening stagnant of air. Air temperature distribution was generally distributed uniform. Relative humidity in cultivation house before , improvement was widely ranged about $44{\sim}100%$. But as the relative humidity after improvement was ranged approximately $80{\sim}100%$, it was maintained within the range of relative humidity recommended. And $CO_2$ concentration was maintained about $400{\sim}3,300mg{\cdot}L^{-1}$ range. The illuminance in cultivation house was widely distributed in accordance with position, and it was maintained lower than the recommended illuminance range $100{\sim}200lx$. The acidity of midium was some lower range than the recommend acidity range of pH $5.5{\sim}6.5$. The yield was relatively ununiform. In case of bottle capacity of 1,300cc, the mushroom of the lowest grade was less than 3%. The consumption electric energy was quite different according to the cultivation season. The electric energy consumed during heating season was much more than that of cooling season.