• Title/Summary/Keyword: 인써트

Search Result 6, Processing Time 0.017 seconds

Strength Improvement of Insert Joint for Composite Sandwich Structure (복합재 샌드위치 구조의 인써트 조인트의 강도 향상)

  • Kim, Kwang-Soo;An, Jae-Mo;Jang, Young-Soon;Yi, Yeong-Moo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2010
  • In this study, joint strength and failure characteristics were experimentally examined with pull-out and shear specimens in which new designed "high strength insert" was applied. The performance of the new insert was compared with typical insert design. The experimental results showed that the "high strength insert" had the joint strengths of 2.1 times in the pull-out specimens and 2.04 times in the shear specimen compared with typical insert joints. Therefore, the new developed "high strength insert" will be usefully used in the aerospace structure.

An Investigation on the Strength of Insert Joints of Composite-Honeycomb Sandwich Structures (복합재 -하니콤 샌드위치 구조물의 인써트 조인트 강도 특성 연구)

  • Choi, Ji-Young;Song, Keun-Il;Choi, Jin-Ho;Kim, Kwang-Soo;Jang, Young-Soon;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.20 no.5
    • /
    • pp.26-33
    • /
    • 2007
  • Pull-out and shear strengths of insert Joints of sandwich structure were investigated by experiment. Specimens were prepared by cocuring of nomex honeycomb core and carbon-epoxy composite face using an adhesive FM73. A total of 75 specimens with 10 different types depending on the core height and density, face thickness, and loading direction were tested. In the test under pull-out loading, although both the core height and density affect the failure loads, the effect of cell density is more serious. Dominant factor fur failure loads of the joints under shear loading is face thickness and the effect of core height is negligible. In the joint with same dimension, failure loads vary depending on the potted area of the core, particularly in the pull-out test.

A Study on the Design of Throw-away Cutting Tool System for Deep Grooving or Cut-off Machining (깊은 홈 및 절단가공용 드로우어웨이식 초경공구 시스템의 설계에 관한 연구)

  • Kim, Hyeung-Chul;Lee, Woo-Young;Namgung, Suk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.1
    • /
    • pp.123-130
    • /
    • 1996
  • The procedure on the design of a new tungsten cabide throw-away cutting tool system for deep grooving or cut-off machining is suggested. For relieving the maximum stress level at the corner radius of the blade holder, the finite element method is used. Also the pulling test device is proposed for measuring the holding force of the insert between the blade holder and the insert considering the materials in contact and configuration parameters of the holder.

  • PDF

Retrospective Evaluation of Implant Retained Overdentures Using Two Implants and Locator Attachments in the Edentulous Mandibles (Locator attachment를 이용한 하악 임플란트 유지 피개의치의 후향적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok;Lee, Cheong-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.153-162
    • /
    • 2013
  • This study compared the marginal bone loss around dental implants that were placed in the canine areas of the mandibles and finded the survival rate of the implants, marginal bone loss around implants and prosthetic complications in 20 patients treated with overdentures retained with Locator attachments. Implants placed in this study showed a 95% survival rate and the average marginal bone loss was 1.21 mm($SD{\pm}0.60mm$) in 94.3 weeks of functional loading. Implant-retained overdentures had various prosthetic complications such as male change, metal cap loosening, Locator attachment loosening, denture teeth change, relining and denture fracture. Implant-retained overdentures using two implants and Locator attachments in the edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.

Effect of TiAIN-based Nanoscale Multilayered Coating on the Cutting Performance of WC-Co Insert (WC-CO 인써트의 절삭 성능에 미치는 TiAIN계 나노 다층막 코팅의 영향)

  • Lim Hee-Youl;Park Jong-Keuk;Kim Kyung-Bae;Choi Doo-Jin;Baik Young-Joon
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.1
    • /
    • pp.110-116
    • /
    • 2006
  • The mechanical property and cutting performance of the cutting tools coated with nanoscale nyktukatered nitride film have been investigated. $Ti_{0.54}Al_{0.46}N-CrN$ and $Ti_{0.84}Al_{0.16}N-NlN$ systems, which showed super-lattice in nanoscale multilayered coating, were deposited on WC-Co insert by UBM sputtering, The superlattice coatings with different bilayer periods were manufactured by controlling deposition parameters. The superlattice formation and hardness of the nanoscale multilayered nitride film and the cutting performance of the insert coated with the film were examined. The hardness and cutting performance were dependent on the bilayer periods of the coatings. The flank wear of the inserts with superlattice coatings were decreased over $20\%$, compared to those of commonly used cutting tools coated with TiAIN single phase.

Clinical evaluation of implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles (Locator attachment를 이용한 하악 임플란트 유지형 피개의치의 임상적 평가)

  • Lee, Ju-Hyoung;Sohn, Dong-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.283-290
    • /
    • 2011
  • Purpose: This study compared the marginal bone loss around dental implant that were placed in the canine areas of the mandibles and finded the survival rate of implants, marginal bone loss around implants and prosthetic complications in 10 patients treated with overdentures retained with Locator attachments. Materials and methods: Ten patients who had received implant retained overdentures in the mandibules using two implants and Locator attachments at Daegu Catholic University Medical Center from 2004 to 2010 were included in this study. Evaluations of the survival rate of implants, marginal bone loss and prosthetic complications were performed. Results: Implants placed in this study showed a 100% survival rate and the average annual bone loss was 1.03 mm ${\pm}$ 0.20 mm in the first year. The patients have verbally indicated that they are comfortable and that their overdentures function well. But, implant retained overdentures had various prosthetic complications such as male change, relining, rebasing and denture fracture. Conclusion: Implant retained overdentures using two implant and Locator attachments in the fully edentulous mandibles is considered as a stable way for long terms because of minimal invasive operation, simple prosthetic process and easy repair.