• Title/Summary/Keyword: 인수검사

Search Result 117, Processing Time 0.023 seconds

Evaluation of an Automated ELISA (VIDAS(R)) and Real-time PCR by Comparing with a Conventional Culture Method for the Detection of Salmonella spp. in Steamed Pork and Raw Broccoli Sprouts (편육과 브로콜리싹에서 Salmonella spp. 검출을 위한 배지법과 Real-time PCR 및 신속 검사키트(VIDAS(R))의 비교검증)

  • Hyeon, Ji-Yeon;Hwang, In-Gyun;Kwak, Hyo-Sun;Park, Jong-Seok;Heo, Seok;Choi, In-Soo;Park, Chan-Kyu;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.29 no.4
    • /
    • pp.506-512
    • /
    • 2009
  • Salmonellosis is an important worldwide foodborne infectious disease that is transmitted by many food vehicles including raw and processed animal products and fresh produce. In this study, the effectiveness of automated ELISA ($VIDAS^{(R)}$) and realtime PCR in the detection of Salmonella spp. in steamed pork and raw broccoli sprouts was evaluated by comparing their results with those of a conventional culture method. Bulk samples (500 g) of steamed pork and raw broccoli sprouts were inoculated with various levels of Salmonella and divided into 20 samples (25 g each). All the samples, including the controls, were analyzed using a conventional culture method, $VIDAS^{(R)}$, and real-time PCR to detect the presence of Salmonella. In addition, the levels of background flora in the steamed pork and the raw broccoli sprouts were determined. In the steamed pork that contained less than 100 CFU/g of aerobic bacteria, all three methods detected low levels of Salmonella without a statistical difference in their performance. In the broccoli sprouts with high quantities of background flora (ca. $6.7{\times}10^7$ CFU/g), however, all three methods were unable to detect low levels of Salmonella, and real-time PCR and $VIDAS^{(R)}$ more sensitively detected Salmonella than the culture method, with significant statistical differences. In conclusion, $VIDAS^{(R)}$ and real-time PCR could be superior to conventional culture methods in detecting Salmonella in food with high levels of background flora.

A Study of Detainees' Perceptions of the Detention Facilities of the Police Station and their Operation (경찰서 유치장 시설 및 운영에 관한 유치인의 인식연구)

  • Jung, Woo-Yeoul;Park, Dong-Kyun;Kim, Do-Kyun
    • Korean Security Journal
    • /
    • no.13
    • /
    • pp.423-449
    • /
    • 2007
  • This research is to investigate the detention facilities of police stations and their real operations through the perceptions of detainees at police station cells and to present the policy suggestions for them. To fulfill the research, a questionnaire was made out on the basis of 'the Regulation on Detention and Escort for Suspects'. 'the Regulation on a Standard Plan for Detention Facilities' and 'the Regulation on the Lowest Standard to Treat Detainees' ; and detainees at 23 police station cells under the jurisdiction of Kyungbuk Local Police Agency were asked to answer it. Policy suggestions following from the result of the investigation of detainees' perceptions of the detention facilities of the police stations are as follows; Firstly, the structure of police station cells should be arranged in straight lines in order to take their human rights into consideration and more detention facilities are needed to be built in order to separate male, female, handicapped and juvenile inmates. Secondly, shower rooms and washrooms outside the cells should always be open to detainees whenever they need to be used. Thirdly, any detention facilities deficient in fire fighting equipment should have exit doors installed as soon as possible in case of an emergency and provide sufficient fire extinguishers considering the number of detainees and the size of the facilities. Fourthly, the detention facilities should have sufficient windows for ventilation and take necessary measures to obtain natural lighting instead of electric lighting. Fifthly, air conditioners should be equipped properly taking account of the number of detainees and the dimensions of the facilities. Policy suggestions according to the result of the investigation of detainees' perceptions of the operation of detention facilities of police stations are as follows; Firstly, the problem of operating the detention facilities must deal with worn-out facilities and measures to secure the budget should be taken as soon as possible. Secondly, considering that most detained suspects have difficulties in livelihood, daily necessaries must be issued to them. Thirdly, personal belongings deposited by inmates must be properly managed with the same documentation throughout the police station detention facilities. The number of female guards to take exclusive charge of the physical checkups and processing of female detainees should be increased. Also the facilities for handicapped detainees must be expanded, improved and managed properly. Fourthly, except for handcuffs and ropes to bind detainees in the detention facilities, helmets to prevent self-harm must be withdrawn. The budget to improve the quality of meal issued by the government must be urgently secured and the price of private food sent to detainees must be readjusted to be in line with the consumer price. Health and medical care and sanitation for detainees must be substantial, and also sunbathing and outdoor exercises should be allowed to detainees.

  • PDF

Physicochemical Characteristics of Korean Traditional Wines Prepared by Addition of Sorghum (Sorghum bicolor L. Moench) Using Different Nuruks (수수 첨가량 및 누룩을 달리한 발효주의 이화학적 특성)

  • Woo, Koan-Sik;Ko, Jee-Yeon;Song, Seuk-Bo;Lee, Jae-Saeng;Oh, Byeong-Geun;Kang, Jong-Rae;Nam, Min-Hee;Ryu, In-Soo;Jeong, Heon-Sang;Seo, Myung-Chul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.4
    • /
    • pp.548-553
    • /
    • 2010
  • This study was carried out to compare the physicochemical characteristics of Korean traditional wines fermented by addition of sorghum (Sorghum bicolor) using different nuruks (SH and BS nuruk). The alcohol contents of the fermented wines ranged from 12.36 to 13.21%. The brix degrees of sorghum wines fermented using SH and BS nuruks were $8.6\sim17.9^{\circ}Bx$ and $7.6\sim20.0^{\circ}Bx$ on addition ratio, respectively. Wine no addedsorghum using SH and BS nuruks showed pH 3.74 and 3.40, total acidity of 1.40 and 1.51%, and 0.441 and 0.149 of turbidity. With increase of sorghum addition, brix degree, pH, turbidity and L-value decreased whereas total acidity and a-value increased. Total color difference (${\Delta}Eab$) parameters of wines fermented in 30, 70 and 100% sorghum addition using SH and BS nuruk were 4.33, 6.63 and 26.13, and 4.08, 5.29 and 10.59. Glucose content decreased with increasing amounts of sorghum. Organic acids such as lactic acid and acetic acid were predominantly detected in the fermented wine. Finally, based on sensory evaluations, the wine fermented by BS nuruk showed the best overall quality at 30% sorghum addition.

Quality Characteristics of Yanggaeng according to the Addition of Plantain (Plantago asiatica L.) Powder (질경이 분말 첨가량에 따른 양갱의 품질 특성)

  • Cho, In-Sook;Moon, Jong-Hee;Hong, Ki-Woon;Park, In-Soo
    • Culinary science and hospitality research
    • /
    • v.22 no.8
    • /
    • pp.226-234
    • /
    • 2016
  • In this study, the possibility of developing new type of yanggaeng has been reviewed by evaluating physio-chemical and sensual characteristics of new yanggaeng products using 5~20% of powder of plantain that is a hardy plant resource from most of hillside in Korea. The moisture contents of plantain powder was 1.9%, DPPH radical scavenging ability was 15.67 mg/mL, and total polyphenol contents was 7.00mg/g. By increasing the adding rate of plantain powder the moisture contents and pH of yanggaeng were decreased. From chromatography, by increasing the adding rate of plantain powder the brightness, L-value was decreased along with redness, a-value, yellowness, and b-value. The a-value of sample group adding 5% of plantain powder was the highest and that of sample group adding 20% was the lowest (p<0.001). From texture measurement shown that the hardness of sample group adding 5% of plantain powder was the highest by 3,937.04 and that of sample group adding 20% of plantain powder was the lowest by 2,153.59. The springiness of sample group adding 5% of plantain powder was the highest by 6.79% and that of sample group adding 20% of plantain powder was the lowest by 4.76%. The cohesiveness of sample group adding 20% of plantain powder was the lowest by 177.35 and it was significant (p<0.001). The result of sensory test showed that sample group adding 10% of plantain powder achieved the highest appraisal from most factors, such as color, scent. sweetness, chewiness, moist level, softness level and total preference. As shown from the above results, the sensory preference of yanggaeng can be improved by adding proper volume of plantain powder while making it, so it is understood that the addition of plantain powder in making yanggaeng would give better possibility in commercialization. By considering sensory preference factor the 10% addition rate of plantain powder while making yanggaeng would be the most proper recipe.

Clinical Outcomes and Prognosis of Patients with Stent Fracture after Successful Drug-Eluting Stent Implantation (관상동맥 약물 방출 스텐트 삽입 후 스텐트 골절에 대한 임상결과 및 예후)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.109-116
    • /
    • 2014
  • Many studies have suggested that in the era of Drug-Eluting Stents(DES) are one of the causes of In-Stent Restenosis(ISR) of Stent Fracture(SF). The present study sought to evaluate clinical characteristics of patients with stent fracture after successful DES implantation. The 4,701 patients were selected for analysis who underwent a follow-up coronary angiography irrespective of ischemic symptoms. The overall incidence of SF was 32 patients(male:female=19:13, Av. age $62.44{\pm}9.8$year, 0.68%). Fractures of Sirolimus-Eluting Stents(SES), Paclitaxel-Eluting Stents(PES), Biolimus A9-Eluting Stents(BES), Everolimus-Eluting Etents(EES), Endothelial Progenitor Cell Capture Stent(EPC) and Zotarolimus-Eluting Stents(ZES) are accounted for 19(59.4%), 9(28.1%), 2(6.3%), 1(3.1%), 1(3.1%) and 0(0%) respectively. SF developed in the left Anterior Dscending(LAD) artery in 16 patients(50%) and in complex(type B2, C) lesions in 25 patients(69.4%). Ten patients were treated with heterogenous DES, the rest being treated with either homogenous DES(3 patients), plain old balloon angioplasty(3 patients), or conservative medical treatment(17 patients). None of the patients with SF suffered from cardiac death during a follow-up period of $32.9{\pm}12.4$ months. The overall rate of DES fracture over up to 3.7 years of follow-up was 0.68% with higher incidence in SES than in PES. SF frequently occurred in the LAD artery and in complex lesions. Of the patients with SF, coronary intervention was performed only when the binary restenosis lesion was significant. During the follow-up, patients with SF have continued on combination antiplatelet therapy. There is a very low rate of major adverse cardiac events(post-detection of SF), especially cardiac death associated with SF.

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

The Study on the Independent Predictive Factor of Restenosis after Percutaneous Coronary Intervention used Drug-Eluting Stent : Case on MDCT Calcium-Scoring Implementation Patient (약물용출 스텐트를 이용한 관상동맥중재술 후 재협착의 독립적 예측인자에 관한 연구 : MDCT calcium-scoring 시행 환자 대상으로)

  • Kim, In-Soo;Han, Jae-Bok;Jang, Seong-Joo;Jang, Young-Ill
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.37-44
    • /
    • 2010
  • We sought to confirm an independent factor about in-stent restenosis (ISR) in the patients who underwent drug-eluting stent (DES) and know a possibility as a predictor of measured coronary artery calcium score by MDCT. A total of 178 patients (159 men, $61.7{\pm}10.0$ years of age) with 190 coronary artery lesions were included in this study out of 1,131 patients who underwent percutaneous coronary intervention (PCI) with DES implantation for significant stenosis on MDCT at Chonnam National University Hospital between May 2006 and May 2009. All lesions were divided into two groups with the presence of ISR : group I (re ISR, N = 57) and group II (no ISR, N = 133). Compared to group II, group I was more likely to be older ($65.8{\pm}9.0$ vs. $60.2{\pm}9.9$ years, p = 0.0001), diabetic (21.8% vs. 52.6%, p = 0.0001), have old myocardial infarction (8.8% vs. 2.3%, p = 0.040), left main stem disease (5.3% vs. 0.8%, p = 0.047), and smaller stent size ($3.1{\pm}0.3\;mm$ vs. $3.3{\pm}0.4\;mm$, p = 0.004). Group II was more likely to be smokers (19.3% vs. 42.1%, p = 0.003), have dyslipidemia (8.8% vs. 23.3%, p = 0.019). Left ventricular ejection fraction, lesion complexity, and stent length were not different between the two groups. Total CAC score was $389.3{\pm}458.3$ in group I and $371.2{\pm}500.8$ in group II (p = 0.185). No statistical difference was observed between the groups in CAC score in the culprit vessel, left main stem, left anterior descending artery, left circumflex artery, and right coronary artery. On multivariate logistic regression analysis, left main stem disease (OR = 168.0, 95% CI = 7.83-3,604.3, p = 0.001), male sex (OR = 36.5, 95% CI = 5.89-2,226.9, p = 0.0001), and the presence of diabetes (OR = 2.62, 95% CI = 1.071-6.450, p = 0.035) were independent predictors of ISR after DES implantation. In patients who underwent DES implantation for significant coronary stenosis on MDCT, ISR was associated with left main stem disease, male sex, and the presence of diabetes. However, CAC score by MDCT was not a predictor of ISR in this study population.