• Title/Summary/Keyword: 인상평가

Search Result 239, Processing Time 0.025 seconds

A Study on the ICAO international aviation safety policy, a change of paradigm and the government response to the direction (ICAO 국제항공안전정책 패러다임의 변화 분석과 우리나라 신국제항공안전정책 검토)

  • Chang, Man-Heui;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.73-96
    • /
    • 2013
  • ICAO's Universal Safety Oversight Audit Programme (USOAP) was initially launched in January 1995, in response to widespread concerns about the adequacy of aviation safety oversight around the world. The recent reduction in aircraft accidents and effective role that is evaluated on the basis of these results, and in 2013 the existing 'snapshot approach' to 'regular monitoring system (USOAP-Continuous Monitoring Approach)' was converted to. ICAO aviation safety assessment of the state in today's international community 'aviation safety credibility' as objective indicators to judge the enormous impact on the aviation industry, the state is not satisfactory, especially if the results of the evaluation and expansion of code-share airline ban, reduced international air transit passengers, including premium increases business and economic penalties should. In addition, ICAO implementation of the existing laws and regulations(Prescriptive Approach), but based on the Risk-based prevention model, Proactive Approach introduced the concept of aviation safety system, including international aviation safety policy has been to switch paradigms. This new ICAO international aviation safety policy also applies to the Government of the Republic of Korea in line with the aviation safey policies have changed. In particular, the systematic implementation of safety management for the existing laws and regulations in the center of the safety oversight system of risk-based introduction of the concept of proactive safety management, and According to international standards ICAO aviation service providers operate their own Safety Management System was set out in Aviation Law ever. In addition, the aviation safety is at the center of the field of the safety of aircraft operations and maintenance for the promotion is promoting various safety policies. This new paradigm shift in the international aviation safety policy in line with our state in the international community with the most exemplary aviation safety system firmly established itself as a model, the Government will strengthen the competitiveness of our aviation plans to support. To do this, the government, airlines, aviation officials try all the practical effect would be expected.

  • PDF

Geographical Structure of View Point in the Landscape Experience on Mountain in Yangsan City (경관체함이 발생하는 조망점의 지리구조에 관한 연구;양산시 소재 산지를 대상으로)

  • Kang, Young-Jo;Cha, Young-Chae;Cha, Myeong-Sook
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.36 no.3
    • /
    • pp.75-84
    • /
    • 2008
  • The purpose of this research is to find the visual characteristics and geographic structure in a landscape of mountains in Yangsan City. In order to carry out this study, 40 view points of 6 mountains in Yangsan City were selected to experience the mountainscape. The results are as follows. The mountainscape of Yangsan City was confirmed from the view point to the object of view as ranging in middle distance reverse, the angle of elevation 11${\sim}13^{\circ}$ which give the impression of confronted to the mountain, and the horizontal angle 50${\sim}90^{\circ}$ which gives the impression of vastness. This shows that mountainscapes are perceived impressively when seeing the mountain with the meaning to feel the texture of the mountain as a confrontational relationship rather than a pictorial relationship. The geographic structure of the view point which occurs in scenes of impressive experience is classified into eight types and its characteristics are investigated. The first type is corridor, and it emerges in a long narrow linear structure made from the surrounding environment with buildings or street trees. The second is tunnel in which a vision and light hidden while passing underneath a bridge, high-level road, or inside a tunnel can be seen. Third, the maze is formed by the mountain shape. The hill spur emerges when the direction of traffic changes after turning the coner of a building or mountain edge. The hill ground emerges at the top of a hill slope. Next, parallel emerges when the observer and the mountain are in the same direction of process. Confrontation occurs when confronting an isolated mountain. Finally, the view point emerges when passing through major points such as a bridge or square and the boundary of a village or city. This research arranged visual conditions that create impressive mountainscapes. Geographic characteristics in terms of Types that make possible to experience mountainscapes were described. The results of this research will be basic data collected for the management and preservation of mountainscapes and for landscape effect evaluation. Furthermore, this research suggests theoretical evidence to preserve and manage geographic structures that create view experiences as well as to preserve the landscape in terms of view points.

Radiotherapic Valuation of Paraffin Wax for Patients with Oral Cancer (구강암 환자 치료시 치과용 기초상 왁스(Paraffin Wax)의 유용성 평가)

  • Na, Kyoung-Su;Seo, Seuk-Jin;Lee, Je-Hee;Yoo, Sook-Heun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • Purpose: This study is designed to investigate radiotherapic valuation of Paraffin Wax, which is newly formed for this study and generally utilized in dentistry, and Mouth Piece and Putty impression, which are commonly used in radiotherapy, for oral cavity as a compensator. Materials and Methods: Each compensator was formed by $10{\times}10{\times}1cm$ and measured radiation dose attenuation ratio with reference of water phantom which is made of tissue-equivalent materials. Two patients with oral cancer underwent DRR (Digitally Reconstructed Radiogrph) of Offline Review Program of Aria System and Portal vision for 5 times for each material to evaluate reproducibility by each filling materials. Moreover, MU (monitor unit) changes by dose absorption were considered in the case of inevitable implication of an filling materials in the range for radiotherapy. Results: Radiation dose attenuation ratios were shown -0.7~+3.7% for Mouth Piece, +0.21~+0.39% for Paraffin Wax and -2.71~-1.76% for Putty impression. Error ranges of reproducibility of positions were measured ${\pm}3mm$ for Mouth Piece, ${\pm}2mm$ for Paraffin Wax and ${\pm}2mm$ mm for Putty impression. Difference of prescription MU from dose absorption with an filling material increased +7.8% (250 MU) in Putty impression and -0.9% (230 MU) in Paraffin Wax as converted into a percentage from the standard phantom, Water 232 MU. Conclusion: Dose reduction of boundary between cavity and tissue was observed for Mouth Piece. Mouth Piece also had low reproducibility of positions as it had no reflection of anatomy of oral cavity even though it was a proper material to separate Maxilla and Mandible during therapy. On the other hand, Putty impression was a suitable material to correctly re-position oral cavity as before. However, it risked normal tissues getting unnecessary over irradiation and it caused radiation dose decrease by -2.5% for 1cm volume in comparison of it of water phantom. Dose reduction in Paraffin Wax, Fat Tissue-Equivalent Material, was smaller than other impressions and position reproducibility of it was remarkable as it was possible to make an anatomy reflected impression. It was also well fitted to oral cavity to transfer radiation dose planned in radiotherapy. Thus, Paraffin Wax will be an ideal material in radiotherapy for patients with oral cancer.

  • PDF

A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems (수종의 CAD/CAM 시스템으로 제작한 지르코니아 기반 완전도재관의 적합도 비교)

  • Kim, Sung-Jun;Jo, Kwang-Hun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.148-155
    • /
    • 2009
  • Statement of problem: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need to evaluate the quality levels of these new fabrication techniques. Purpose: This study is to evaluate the crown fidelity(absolute marginal discrepancy and internal gap) of various zirconia-based all-ceramic crowns fabricated with different CAD/CAM(computer-assisted design/computer-assisted manufacturing) systems and conventional cast metal-ceramic crowns. Material and methods: A resin tooth of lower right second premolar was prepared. After an impression was taken, one metal master die was made. Then 40 impressions of metal master dies were taken for working dies. 10 crowns per each system were fabricated using 40 working dies. Metal-ceramic crowns were cast by using the conventional method, and Procera, Lava, and Cerec inLab crowns were fabricated with their own CAD/CAM manufactruing procedures. The vertical marginal discrepancies and internal gaps of each crown groups were measured on a metal master die without a luting agent. The results were statistically analyzed using the one-way ANOVA and Tukey's HSD test. Results: 1. Vertical marginal discrepancies were $50.6{\pm}13.9{\mu}m$ for metal-ceramic crowns, $62.3{\pm}15.7{\mu}m$ for Procera crowns, $45.3{\pm}7.9{\mu}m$ for Lava crowns, and $71.2{\pm}2.0{\mu}m$ for Cerec inLab crowns. 2. The Internal gaps were $52.6{\pm}10.1{\mu}m$ for metal-ceramic crowns, $161.7{\pm}18.5{\mu}m$ for Procera crowns, $63.0{\pm}10.2{\mu}m$ for Lava crowns, and $73.7{\pm}10.7{\mu}m$ for Cerec inLab crowns. Conclusion: 1. The vertical marginal discrepancies of, 4 crown groups were all within the clinically acceptable range($120{\mu}m$). 2. The internal gaps of LAVA, Cerec inlab, and metal-ceramic crowns were within clinically acceptable range except Procera crown($140{\mu}m$).

Comparative study of volumetric change in water-stored and dry-stored complete denture base (공기중과 수중에서 보관한 총의치 의치상의 체적변화에 대한 비교연구)

  • Kim, Jinseon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.18-26
    • /
    • 2021
  • Purpose: Generally, patients are noticed to store denture in water when removed from the mouth. However, few studies have reported the advantage of volumetric change in underwater storage over dry storage. To be a reference in defining the proper denture storage method, this study aims to evaluate the volumetric change and dimensional deformation in case of underwater and dry storage. Materials and methods: Definitive casts were scanned by a model scanner, and denture bases were designed with computer-aided design (CAD) software. Twelve denture bases (upper 6, lower 6) were printed with 3D printer. Printed denture bases were invested and flasked with heat-curing method. 6 upper and 6 lower dentures were divided into group A and B, and each group contains 3 upper and 3 lower dentures. Group A was stored dry at room temperature, group B was stored underwater. Group B was scanned at every 24 hours for 28 days and scanned data was saved as stereolithography (SLA) file. These SLA files were analyzed to measure the difference in volumetric change of a month and Kruskal-Wallis test were used for statistical analysis. Best-fit algorithm was used to overlap and 3-dimensional color-coded map was used to observe the changing pattern of impression surface. Results: No significant difference was found in volumetric changes regardless of the storage methods. In dry-stored denture base, significant changes were found in the palate of upper jaw and posterior lingual border of lower jaw in direction away from the underlying tissue, maxillary tuberosity of upper jaw and retromolar pad area of lower jaw in direction towards the underlying tissue. Conclusion: Storing the denture underwater shows less volumetric change of impression surface than storing in the dry air.

Full mouth rehabilitation with maxillary implant overdenture using prefabricated bar attachment system: a case report (기성품 바 어태치먼트 시스템인 SFI bar를 이용한 피개의치 전악수복 증례)

  • Shin, Eun-Jung;Joo, Han-Sung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil;Yun, Kwi-Dug
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.331-337
    • /
    • 2014
  • In conventional bar- and clip-retained overdentures, all errors during impression making and cast fabrication result in non-passive fit of bars. SFI bar is prefabricated and assembled in the patient's mouth without the use of soldering, laser welding or conventional bonding techniques, thus reducing stress transmission to, bone loss around the implants and leading to fewer errors and lower costs. A clinical case will be presented below to demonstrate the use of the SFI Bar (Stress Free on Implant Bar) to restore an severe atrophy edentulous maxilla. In this case, no lateral stress could be applied to the implants due to the telescopic design of the bar joints. However, periodic recall check is necessary and long-term clinical results are required.

Spatial changes of the maxillofacial complex following maxillary protraction of human dry skull (건조 두개골에서 상악의 전방 견인후 상악 안면 복합체의 공간 변화에 관한 연구)

  • Chun, Youn Sic;Choi, Jang Woo;Choi, Seung Eun;Lee, Seong Geun
    • The korean journal of orthodontics
    • /
    • v.32 no.6 s.95
    • /
    • pp.425-434
    • /
    • 2002
  • The purpose of this investigation was to study the spatial changes of the maxillofacial complex following maxillary protraction transmitted to the center of resistance of a dry juvenile human skull by a modified maxillary protraction appliance. Four dry juvenile human skulls (without mandible) with well aligned upper deciduous dentition and early mixed dentition were used as experimental samples. A modified protraction headgear was fabricated from a Delare's facemask, and following an alginate impression, an orthodontic resin maxillary splint was made for each dry skull. Protraction force level was maintained at approximately 1000gm per side for 6 hours. Cephalometric radiographs were taken pre- and post- protraction, and nine reference markers with 1.5 mm length of $.017\times.025$ TMA wire were placed on the right side of the skull for an accurate superimposition of serial cephalometric radiographs. The present investigation demonstrated that vertical changes associated with an anterior displacement of the maxillary complex was observed, and the most prominent effect of protraction headgear was a counterclockwise rotation of the maxilla, that is, a forward and downward tipping around the palatomaxillary region.

Quantitative evaluation of cortical bone and soft tissue thickness in the mandible (하악 피질골과 연조직의 해부학적 두께를 위한 정량적 평가)

  • Lee, Soo-Kyung;Chun, Youn-Sic;Lim, Won-Hee
    • The korean journal of orthodontics
    • /
    • v.37 no.3 s.122
    • /
    • pp.212-219
    • /
    • 2007
  • Objective: The purpose of this study was to provide an anatomical reference for cortical bone and soft tissue thickness, and the attached gingiva width in the mandible. Methods: Fifteen males and fifteen females participated in this study. An acrylic template was fabricated and the radiopaque markers were bonded on the estimated alveolar crest to take measurements of the hard and soft tissue thickness at the same locations. CT images were taken in samples wearing an acrylic template. Cortical bone and soft tissue thickness were measured at 2, 4, 6 and 8 mm from the alveolar crest in interradicular spaces from central incisor to first permanent molar. The attached gingival width was calibrated. Results: Cortical bone thickness was $1.33{\pm}0.38mm$ and soft tissue thickness was $1.49{\pm}0.54mm$. Cortical bone thickness was increased in the posterior area, while it was not the case for the soft tissue thickness. In addition, the total thickness was $2.82{\pm}0.70$. The attached gingival width was wider in the anterior area compared to that in posterior area. Conclusion: These results suggest that the attached gingiva width should be considered upon placement of mini-implants in the mandibular posterior area for orthodontic anchorage.

Fabrication and characterization of glass with E-glass fiber composition by using silica-alumina refused coal ore (사암계 석탄폐석을 활용한 E-glass fiber 조성의 유리 제조 및 특성)

  • Lee, Ji-Sun;Lim, Tae-Young;Lee, Mi-Jai;Hwang, Jonghee;Kim, Jin-Ho;Hyun, Soong-Keun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.4
    • /
    • pp.180-188
    • /
    • 2013
  • The glass of E-glass fiber composition was fabricated by using refused coal ore which is obtained as by-product from Dogye coal mine in Samcheok. We used silica-alumina refused coal ore which has low carbon content relatively, and the amount of refused coal ore has been changed from 0 to 35 % in batch composition. E-glass was fabricated by the melting of mixed batch materials at $1550^{\circ}C$ for 2 hrs with different refused coal ore composition of 0~35 %. We obtained a transparent and clear glass with high visible light transmittance value of 81~84%, thermal expansion coefficient of $5.39{\sim}5.61{\times}10^{-6}/^{\circ}C$ and softening point of $851{\sim}860^{\circ}C$. The glass fiber samples were also obtained through fiberizing equipment at $1150^{\circ}C$, and tested chemical resistance and tensile strength to evaluate the mechanical property as a reinforced glass fiber of composite material. As the result, we identified the properties of E-glass fiber by using refused coal ore are plenty good enough compare to that of normal E-glass without refused coal ore, and confirmed the possibility of refused coal ore as for the raw material of E-glass fiber.

The shear bond strength and adhesive failure pattern in bracket bonding with different light-curing methods (브라켓 접착시 광중합방식에 따른 전단결합강도와 파절양상 비교)

  • Shin, Jai-Ho;Lim, Yong-Kyu;Lee, Dong-Yul
    • The korean journal of orthodontics
    • /
    • v.34 no.4 s.105
    • /
    • pp.333-342
    • /
    • 2004
  • The purpose of this study was to evaluate the clinical effectiveness of a plasma arc light and light emitting diode (LED), compared with shear bond strength and the failure pattern of brackets bonded with visible light in direct bonding. Brackets were bonded with Transbond XT to 60 human premolars embedded in the resin blocks according to different light-curing methods. Then, the shear bond strength of each group was measured using a universal testing machine (Instron) and the adhesive failure pattern after debonding was visually examined by light microscope. The results were as follows: 1. The shear bond strength showed no significant difference between the visible light and light emitting diode, but the plasma arc light exhibited a significantly lower shear bond strength compared with the visible light and light emitting diode. 2. In the visible light and light emitting diode, adhesive failure patterns were similar. Bond failure occurred more frequently at the enamel-adhesive interface. 3. The bonding failure of brackets bonded with plasma arc light occurred more frequently at the bracket-adhesive interface. The results of this study suggest that plasma arc light, light emitting diode and visible light are all clinically useful in the direct bonding of orthodontic brackets.