• 제목/요약/키워드: 인버터 열펌프

검색결과 18건 처리시간 0.022초

착상을 수반한 멀티 가변속 열펌프의 동특성 (A Dynamic Characteristic of the Multi-Inverter Heat Pump with Frosting)

  • 박병덕;이주동;;황일남;장세동;황정하
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.337-345
    • /
    • 2003
  • In the case of heat exchangers operating under frosting condition, the growth of frost layer causes the heat exchanger to increase the thermal resistance and pressure loss of the air flow. In this paper, a transient characteristic prediction model of the heat transfer for multi inverter heat pump with frosting on its surface was presented taking into account the change of the fin efficiency due to the growth of the frost layer. In this dynamic simulation program, which was peformed for a basic air conditioning system model, such as evaporator, condenser, compressor, linear electronic expansion valve (LEV) and bypass circuit. The theoretical model was driven from the obtained heat transfer coefficient and mass transfer coefficient, independently. And we consider heat transfer performance was only affected by a decrease of the wind flow area. The calculated results were compared with some cases of experiments for frosting conditions.

실내기 조합에 따른 3실형 열펌프의 냉방성능 실험연구 (Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination)

  • 권영철;전종균;박윤창;고국원;서동남
    • 한국산학기술학회논문지
    • /
    • 제9권6호
    • /
    • pp.1487-1493
    • /
    • 2008
  • 본 연구에서는 인버터 압축기를 적용한 3실형 멀티-열펌프 시스템의 냉방운전 시 시스템의 성능특성을 조사하였다. 시스템의 운전특성은 항온항습 기능을 가진 공기엔탈피방식의 칼로리미터를 이용하여 측정되었으며, 냉방표준 및 냉방저온 온도조건에서 실내기 조합에 따른 실험이 수행되었다. 3실형 열펌프의 실내기 조합운전에 따른 냉방 표준운전 및 냉방저온운전 시의 냉방능력, COP, P-h선도로부터, 3실형 열펌프의 운전특성과 냉방사이클의 거동을 이해하였다. 열펌프의 운전부하와 성능은 실내기 조합에 의존하므로 시스템의 능력과 사이클의 거동은 다르게 관찰되었다. 과냉도 증가와 압축일의 감소로 표준조건보다 저온조건에서 냉방능력과 COP가 더 높았다. 또한 P-h 선도를 이용하여 사이클의 운전특성도 분석하였다.

폐수열 히트펌프 재생에너지 시스템 설계 (Design of Heat Pump Renewable Energy System Using Wastewater with a Heat Source)

  • 추연규;김봉기;김성두
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 춘계학술대회
    • /
    • pp.787-790
    • /
    • 2011
  • 본 연구에서는 페수열 회수 보일러에서 버려지는 페수열을 재생하여 에너지를 재활용하기 위하여 퍼지제어 알고리즘을 사용한 지능제어기를 설계하고자 한다. 폐수유입온도의 변화와 폐수유입량의 변화를 파라미터로 하여 컴프레서의 정속운전 대수와 토출온수온도의 특성곡선을 전문가의 지식으로부터 얻을 수 있다. 폐수열 회수 보일러에 유입되는 폐수부하에 따른 컴프레서의 정속운전 대수를 최소화 하기위해 폐수유입온도와 유입량의 변화를 측정하여 최적의 정속운전 대수 및 인버터 운전량을 실시간으로 결정하는 지능제어기를 설계하여 페수열 부하의 변동을 실시간으로 추정하여 최소의 컴프레서 운전대수 및 조작량을 제어함으로써 에너지 효율과 경제성을 극대화할 수 있다.

  • PDF

멀티형 인버터 열펌프의 냉방성능해석에 관한 연구 (Performance Analysis of a Multi-type Inverter Heat Pump)

  • 김영철;박근우;윤영;민만기;최영돈
    • 설비공학논문집
    • /
    • 제13권3호
    • /
    • pp.153-159
    • /
    • 2001
  • A system simulation program was developed for a multi-type inverter heat pump. Electronic expansion valve(EEV) was used to extend the capacity modulating range of the heat pump as expansion device. The program was also developed to calculate actual system performance with the building load variation with climate during a year. The performance variation of a multi-type hat pump with two EEV and an inverter compressor was simulated with compressor speed, capacity, and flow area of the EEV. As a result, the optimum operating frequency of the compressor and openings of the expansion device were decided at a given load. As compressor speed increased, he capacity of heat pump increased, the capacity of heat pump increased. Therefore flow area of EEV should be adjusted to have wide openness. Thus the coefficient of performance(COP) of the heat pump decreased due to increasement of compressor power input. The maximum COP point at a given load was decided according to the compressor speed. And under the given specific compressor speed and the load, the optimum openings point of EEV was also decided. Although the total load of indoor units was constant, the operating frequency increased as the fraction of load in a room increased. Finally ad the compressor power input increased, the coefficient of performance decreased.

  • PDF

인버터 적용 펌프모타의 부하운전별 진동해석 (Analysis of Vibration of apply to drive pump with inverter)

  • 황진열;김기원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1131-1132
    • /
    • 2011
  • For the purpose to flow control of pump in booster pump station, nonlinear-load inverter equipment is being introduced. While inverter equipment has the advantage of power-ratio savings and volume control, due to the vibration of pump and motor, secondary breakdown may occur Purpose in this paper is reliable facility operation by providing optimal operationg standards through vibration analysis of apply to drive pump with inverter in long-term in booster pump station.

  • PDF

인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성 (Performance Characteristics of Water-Chilling Heat Pump Using CO2 on Control of Inverter Frequency)

  • 손창효
    • 한국산학기술학회논문지
    • /
    • 제11권12호
    • /
    • pp.4721-4726
    • /
    • 2010
  • 본 논문은 압축기 인버터 주파수 제어에 따른 CO2용 수냉식 열펌프의 성능 특성에 대해서 실험적으로 조사하였다. 실험장치는 압축기, 가스냉각기, 팽창밸브, 증발기, 내부 열교환기, 수액기로 구성된다. 실험장치에 사용된 모든 열교환기는 동관으로 제작된 이중관식 대향류형이다. 가스냉각기와 증발기는 2.4 m인 소시험부 6개와 4개로 각각 구성된다. 실험결과를 요약하면, 우선 증발기와 가스냉각기의 입구온도와 냉매유량이 일정한 조건하에서 압축기 인버터 주파수가 증가할수록 압축비와 토출압력이 증가한다. 또한 인버터 주파수가 증가할수록 난방능력과 압축일량은 증가하는 반면 성능계수는 감소한다. 그리고 증발기 입구 2차유체의 온도가 $15^{\circ}C$에서 $25^{\circ}C$로 증가함에 따라 압축비와 압축일량은 감소하지만 질량유량, 난방능력, 성능계수는 증가한다. 위의 이러한 경향은 종래의 프레온계 냉매 시스템의 성능 변화와 유사하다.

바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구 (Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

복합 미생물 배양기의 제어시스템 개발 (Development of control system for complex microbial incubator)

  • 김홍직;이원복;이승호
    • 전기전자학회논문지
    • /
    • 제27권1호
    • /
    • pp.122-126
    • /
    • 2023
  • 본 논문에서는 복합 미생물 배양기의 제어시스템을 제안하였다. 제안하는 제어시스템은 복합 미생물 배양기의 제어부, 통신부, 전원부, 제어시스템 등으로 구성된다. 복합 미생물 배양기의 제어부는 아날로그 신호와 디지털 신호의 변환, LCD 패널을 이용한 디스플레이, 수위센서, 온도센서, pH 농도센서 등과 같은 센서들의 신호 제어를 하도록 설계 및 제작한다. 사용하는 수위센서는 기존 수위센서가 거품과 같은 이물질 등으로 인해 측정이 어려운 문제점을 해결하고자 직진성이 우수한 IR 레이저 방식을 사용하여 정확한 수위 측정이 가능하도록 설계 및 제작한다. 온도센서는 열 저항 원리를 사용하여 측정함으로써, 높은 정확도와 누적 저항 오차가 없도록 설계하여 사용한다. 통신부는 2개의 LAN 포트와 1개의 RS-232 포트로 구성하여 복합 미생물 배양기에서 사용되는 LCD 패널, PCT 패널, 로드셀 컨트롤러 등의 신호를 제어부에 전달할 수 있도록 설계 및 제작한다. 전원부는 제어부와 통신부가 원활하게 동작할 수 있도록 24V, 12V 5V 등 3개의 전압 공급 단자로 구성하여 전원을 공급하도록 설계 및 제작한다. 복합 미생물 배양기의 제어시스템은 PLC를 사용하여 pH 농도센서, 온도센서, 수위센서 등의 센서값과 배양에 사용되는 써큘레이션 펌프, 써큘레이션 밸브, 로터리 펌프와 인버터 로드셀 등의 동작을 제어한다. 제안된 복합 미생물 배양기의 제어시스템의 성능을 평가하기 위하여 공인인증기관에서 실험한 결과는 수위 측정감도의 범위가 -0.41mm~1.59mm로, 물 온도의 변화 폭이 ±0.41℃로 현재 상용으로 판매되는 제품들 성능보다 우수한 성능으로 동작됨이 확인되었다. 따라서, 본 논문에서 제안한 복합 미생물 배양기의 제어시스템의 효용성이 입증되었다.