• Title/Summary/Keyword: 인발지지력

Search Result 59, Processing Time 0.026 seconds

Study on Pullout Behavior and Determination of Ultimate Uplift Capacity of Pile Driven in Small Pressured Chamber (소형 압력 토조내에 타입된 말뚝의 인발 거동과 극한 인발 지지력 결정에 관한 연구)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.11 no.2
    • /
    • pp.19-28
    • /
    • 1995
  • Based on the various test data acquired in the field, the large pressure chamber and the small pressure chamber, uplift behaviors and method of determining the ultimate uplift capacity of pile driven in small pressure chamber were studied. After uplift pile experienced 2 or 3 sudden slip due to increase of uplift load, complete pullout failure was occurred. Thus, it appears that the ultimate uplift capacity could be identified as the load at displacement where first slip occurs. The ultimate uplift capacity might be determined in every test and the disturbance after first uplift test could be recovered by adding one blow of the drop hammer, which had to depend on the model pile capacity.

  • PDF

Evaluation on Bearing Resistance of Transverse Members in Steel Strip Reinforcement using Pullout Tests and Theoretical Equations (인발시험과 이론식을 이용한 강재스트립 보강재에 설치된 지지부재의 지지저항 특성 평가)

  • Han, Jung-Geun;Yoon, Won-Il;Hong, Ki-Kwon;Hong, Won-Pyo;Lee, Kwang-Wu;Cho, Sam-Deok
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.2
    • /
    • pp.33-40
    • /
    • 2010
  • In this study, the pullout tests are conducted to evaluate pullout resistance of steel strip reinforcement with transverse members. The test results are compared with theoretical equations and then the failure mechanism of transverse members is evaluated. The bearing resistance stress(${\sigma}^{\prime}_b$) of transverse members, which is applied pullout force at 50mm displacement, is closed from punching shear failure to general shear failure. The behavior by increment of a number of transverse members became closer to general shear failure. The behavior of transverse members at maximum pullout force, which is closed to general shear failure, is indicated that it is unrelated to normal stress and a number of transverse members. However, if the allowable displacement of reinforced soil wall is considered, it is impossible to apply in design. The test results are compared with bearing resistance evaluations using Prandtl's plastic theory and cylindrical cavity expansion theory. The analysis results are indicated that the bearing resistance by pullout tests is closed to predicted result by Prandtl's plastic theory, which are located between general shear failure and punching shear failure.

  • PDF

A Study on the Side Shear Developed during Pullout of Suction Pile in Clays using 3D Numerical Analysis (3차원 수치해석을 이용한 점토지반에 설치된 석션파일 인발 시 발현되는 전단응력에 관한 연구)

  • Lee, Myungjae;Youn, Heejung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.2
    • /
    • pp.59-66
    • /
    • 2014
  • This paper presents the pullout behavior of suction pile using finite difference method; and the commercial software, FLAC3D, was employed for the numerical analyses. The ultimate pullout capacity of suction pile was predicted using conventional equations, and the results were compared with the results from numerical analyses with varying pile diameter, pile length, and the undrained shear strength of clays. Based on the results from 24 analyses, it was found that the failure pattern depends not only on the drainage condition of suction pile, but also on the pile dimensions and the material properties of surrounding soils. The developed side shear (DSS) along the internal surface of the suction pile was collected from numerical analyses, which was used to classify the failure type between sliding failure and tensile failure. Regardless of the external DSS, the high internal DSS tends to result in sliding failure in the numerical analyses, which conforms well to the estimation from conventional equations.

An Optimum Slanting Angle in Reticulated Root Piles Installation under Compressive and Uplift Loads (압축 및 인발하중을 받는 그물식 뿌리말뚝의 최적 타설경사각)

  • 이승현;김명보
    • Geotechnical Engineering
    • /
    • v.12 no.2
    • /
    • pp.71-84
    • /
    • 1996
  • In order to investigate the influence of slanting angle of reticulated root piles(RRP) on their bearing capacities, model tests of compressive and uplift loads on RRP with different slanting angles, which were installed in sandy soils with a relative density of 47%, were carried out. Each pile which is made of a steel bar of 5mm in diameter and 300mm in length, is coated with sand to be 6.5mm in diameter. One set of RRP consists of 8 piles which are installed in circular patterns forming two concentric circles, each of which has 4 piles. Slanting angles of RRP for load tests are 0$^{\circ}$, 5$^{\circ}$, 10$^{\circ}$, 15$^{\circ}$, 20$^{\circ}$, and 25$^{\circ}$. In addition, compressive load tests on circular footing whose diameter is the same as the outer circle of RRP were carried out. Test results show that maximum load bearing capacities of RRP by regression analysis are obtained at about 12$^{\circ}$ and 13$^{\circ}$ of slanting angles for compressive and uplift load tests, respectively. Maximum compressive bearing capacity is estimated to be 13oA bigger than that of the vertical RRP and 95% bigger than that of surface footing. Maximum uplift capacity is estimated to be 21% bigger than that of the vertical RRP. And it can be appreciated that increasing the slanting angle makes the load -Settlement behavior more ductile.

  • PDF

Evaluation of Field Applicability of Helical Pile Using Hexagon Joints (육각형 이음부를 이용한 회전관입말뚝의 현장적용성 평가)

  • Jeong, Sangguk
    • The Journal of Engineering Geology
    • /
    • v.30 no.4
    • /
    • pp.635-648
    • /
    • 2020
  • Performance improvement of helical piles in static load tests using hexagon joints that do not require welding or bolting was investigated. Two sites were selected for pile field tests to evaluate their bearing capacity. Static and pull-out load tests were undertaken to assess the method for estimating bearing capacity. The field tests indicated that the bearing capacity of the gravity grout pile was ≥600 kN in the static load test, consistent with the AC 358 Code. The non-grout pile had a bearing capacity of ≤600 kN, suggesting that gravity grouting is required. Field pile load-test results were used to establish the bearing capacity equation, based on a small number of helical pile.

Undrained Behavior of Model Drilled Shafts to Inclined Repeated Loadings (경사반복하중을 받는 모형현장타설말뚝의 비배수 거동)

  • 조남준;박정순;이장덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.3
    • /
    • pp.77-82
    • /
    • 2001
  • 반복하중을 받는 현장타설말뚝에 대한 두 가지의 주요 관심사항은: (a) 지지력의 변화 가능성 그리고 (b) 누적변형량에 의한 기초의 가능성 저하이다. 이러한 인자들에 대한 평가를 위하여, 모형점토지반에 설치된 24개의 모형현장타설말뚝에 대한 정적 및 동적경사재하시험(12개의 압축 및 12개의 인발)을 수행하였다. 경사반복압축재하시험에서는 반복하중에 의한 지지력의 변화가 무시할 정도였으며, 누적변형량은 송전철탑의 기능성에 영향을 줄수도 있을 것으로 사료된다. 그러나, 경사반복인발시험에서는 과도한 누적변형이 발생하게 되어 결과적으로 현장타설말뚝주변과 점토사이의 접촉면적이 감소하는 것으로 나타났다. 접촉면적의 감소 결과, 반복경사인발하중에 의해서 경사인발지지력의 현저한 감소가 일어난다는 사실을 알 수 있었다. 정적경사인발지지력의 50에서 70퍼센트에 해당되는 반복하중을 받는 대부분의 현장타설말뚝들은 인발되었다.

  • PDF

Numerical Analysis of Group Suction Anchor of Parallel Arrangement Installed in Sand Subjected to Pullout Load (모래지반에 설치된 병렬식 그룹석션앵커의 인발하중에 대한 수치해석 연구)

  • Kim, Surin;Choo, Yun Wook;Kwon, Osoon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.11
    • /
    • pp.61-69
    • /
    • 2014
  • In this study, the performance of group suction anchors installed in sand and subjected to pullout loading was investigated by numerical analysis. The group suction anchors consist of two or three units rigidly connected to each other in parallel array and the pullout resistances were compared with that of a single anchor. Parametric study was performed using numerical models to study the effect of the physical conditions of the group anchor. The parameters include the skirt length to diameter ratio of a unit suction anchor, the pad-eye location, inclination of loading and the spacing between unit suction anchors. The analysis shows that the ratios of the pullout capacity of double suction anchor and triple suction anchor to that of single anchor are 1.7 and 2.4, respectively. The ratio increases with the increase in the spacing between the unit anchors. The other parameters such as the skirt length to the diameter ratio, the location of the pad-eye and the loading inclination have negligible effect on the ratio of pullout resistances of the group anchor to the single anchor.

Evaluation of Skin Friction Using Tensile Load Testing of CPR Piles (CPR 말뚝의 인발재하시험을 통한 주면마찰력 평가)

  • Ko, Chin-Surk;Kim, Jung-Han;Noh, Jeongdu;Kang, Seong-Seung
    • The Journal of Engineering Geology
    • /
    • v.30 no.1
    • /
    • pp.59-69
    • /
    • 2020
  • Pull-out load tests were performed on a CPR (Compaction grouting compound Pile with Reinforce) test pile, with skin friction being evaluated by the yield load and allowable bearing capacity after analyzing load-displacement curves and load-settlement curves. Results of the CPR test piles analyzed from the load-displacement curves show that the yield load and allowable bearing capacity of the large-diameter CPR test pile were about 1.4 times larger than that of the small-diameter pile. Results of the load-settlement curves reveal that the allowable bearing capacity of the CPR test pile with diameter of D500 was 1.2~2.1 times greater than that of the pile with diameter of D400. However, the allowable bearing capacity calculated using Fuller's analysis differed substantially from that determined using the P (Pull-out load) - S (Settlement) and log P - log S curves. Therefore, calculation of the allowable bearing capacity using Fuller's analysis is shown to be inappropriate.

Evaluation Method for Uplift Load-carrying Capacity of Inclined Group Micropiles in Dense Sand (조밀한 사질토지반에서 경사로 설치된 그룹 마이크로파일의 인발지지력 평가방법)

  • Kyung, Doohyun;Kim, Garam;Kim, Incheol;Lee, Junhwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.1
    • /
    • pp.67-77
    • /
    • 2017
  • In the present study, uplift load carrying behavior of micropiles with installation angle and pile spacing was investigated based on uplift load tests using single and group micropiles. In addition, evaluation methods of uplift load carrying capacity of group micropiles were proposed based on FHWA (2005) and Madhav (1987) and they were compared with test results to confirm the validity of proposed methods. From the test results, uplift load carrying capacities of single and group micropiles increased with the increase of the installation angle up to $30^{\circ}$, whose values also increased slightly with increasing pile spacing. For the proposed method based on FHWA (2005), the estimated values were similar to measured values up to $15^{\circ}$ of installation angle and 5D of pile spacing. For the proposed method based on Madhav (1987), on the other hand, it was observed that the estimated values were in good agreement with measured values in all installation conditions.

Load Transfer of Ground Anchors in Clay (점토지반에 설치된 앵커의 하중전이에 관한 연구)

  • Kim, Nak-Kyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.3
    • /
    • pp.145-155
    • /
    • 2000
  • 지반과 구조물을 일체화시키는데 사용하는 앵커는 앵커체와 지반의 마찰력에 의해서 구조물을 지지하는 역할을 하며 앵커의 하중과 변형의 관계를 규명하기 위해서는 앵커의 마찰력 분포의 변화(하중전이)가 중요한 요소가 된다. 하중 재하시 앵커체에 발생하는 하중전이 분포는 앵커의 인발 지지력과 밀접한 관계가 있고 정착장의길이, 지반 조건 등에 따라 분포 양상이 변하기 때문에 하중 정이를 이해하기 위해서는 강선과 그라우트의 하중분포 그리로 앵커 그라우트체와 지반과의 마착력 분포를 알아야 한다. 본 연구는 미국 Texax A&M University의 점성토지반에 계측기가 장착된 10개의 그라운드 앵커를 설치하여 인발시험을 수행하였다. 앵커의 자유장 강선에 작용하는 응력, 그라우트체에 작용하는 응력, 그리고 정착장 강선의 응력을 계측하여 강선과 그라우트의 정착응력 및 그라우트와 지반에서의 마찰력 분포를 구함으로써 강선-그라우트-지반의 복합적인 거동에 따른 각 하중 단계마다의 하중전이를 얻어냈다. 또한 현장시험 결과의 역해석을 통하여 강선과 그라우트 사이의 하중과 변위의 관계와 그라우트와 지반의 하중-변위 관계를 분석하여 그라운드 앵커의 인발 특성을 예측 할 수 있는 수치해석 기법을 모델링하여 제시하였다.

  • PDF