• Title/Summary/Keyword: 인공 심장판막

Search Result 194, Processing Time 0.038 seconds

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

Determination of Practical Dosing of Warfarin in Korean Outpatients with Mechanical Heart Valves (인공심장판막 치환환자의 Warfarin 용량결정)

  • Lee Ju Yeun;Jeong Young Mi;Lee Myung Koo;Kim Ki-bong;Ahn Hyuk;Lee Byung Koo
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.761-772
    • /
    • 2005
  • Background: Following the implantation of heart valve prostheses, it is important to maintain therapeutic INR to reduce the risk of thromboembolism. The objective of this study was to suggest a practical dosing guideline for Korean outpatients with prosthetic heart valves managed by a pharmacist-run anticoagulation service (ACS). Material and Method: A retrospective chart review was completed for all patients enrolled in the ACS at Seoul National University Hospital from March, 1997 to September, 2000. Patients who were at least 6 months post-valve replacement and had nontherapeutic INR value (less than 2.0 or greater than 3.0) were included. The data on 688 patients (1,782 visits) requiring dosing adjustment without any known drug or food interaction with warfarin were analyzed. The amount of adjusted dose and INR changes based on the INR at the time of the event were calculated. Aortic valve replacements (AVR) patients and mitral or double valve replacement (MVR/DVR) patients were evaluated separately. Result: Two methods for the warfarin dosage adjustment were suggested: Guideline I (mg-based total weekly dose (TWD) adjustment), Guideline II (percentage-based TWD adjustment). The effectiveness of Guideline 1 was superior to Guideline II overall in patients with both AVR and MVR/DVR. Conclusion: The guideline suggested in this study could be useful when the dosage adjustment of wafarin is necessary in outpatients with mechanical heart valves.

Biocompatibility of Tissue-Engineered Heart Valve Leaflets Based on Acellular Xenografts (세포를 제거한 이종 심장 판막 이식편을 사용한 조직공학 심장 판막첨의 생체 적합성에 대한 연구)

  • 이원용;성상현;김원곤
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.297-306
    • /
    • 2004
  • Current artificial heart valves have several disadvantages, such as thromboembolism, limited durability, infection, and inability to grow. The solution to these problems would be to develop a tissue-engineered heart valves containing autologous cells. The aim of this study was to optimize the protocol to obtain a porcine acellular matrix and seed goat autologous endothelial cells on it, and to evaluate the biological responses of xenograft and xeno-autograft heart valves in goats. Material and Method: Fresh porcine pulmonic valves were treated with one method among 3 representative decellularization protocols (Triton-X, freeze-thawing, and NaCl-SDS). Goat venous endothelial cells were isolated and seeded onto the acellularized xenograft leaflets. Microscopic examinations were done to select the most effective method of decellularizing xenogeneic cells and seeding autologous endothelial cells. Two pulmonic valve leaflets of. 6 goats were replaced by acellularized porcine leaflets with or without seeding autologous endothelial cells while on cardiopulmonary bypass. Goats were sacrificed electively at 6 hours, 1 day, 1 week, 1 month, 3 months, and 6. months after operation. Morphologic examinations were done to see the biological responses of replaced valve leaflets. Result: The microscopic examinations showed that porcine cells were almost completely removed in the leaflets treated with NaCl-SDS. The seeded endothelial cells were more evenly preserved in NaCl-SDS treatment. All 6 goats survived the operation without complications. The xeno- autografts and xenografts showed the appearance, the remodeling process, and the cellular functions of myofibroblasts, 1 day, 1 month, and 3 months after operation, respectively. They were compatible with the native pulmonary leaflet (control group) except for the increased cellularity at 6 months. The xenografts revealed the new endothelial cell lining at that time. Conclusion: Treatment with NaCl-SDS was most effective in obtaining decellularized xenografts and facilitate seeding autologous endothelial cells. The xenografts and xeno-autografts were repopulated with myofibroblasts and endothelial cells in situ serially. Both of grafts served as a matrix for a tissue engineered heart valve and developed into autologous tissue for 6 months.

Aortic Root Replacement with Homograft in Behcet's Disease -A Case Report- (베체씨 병에서의 동종 이식편을 이용한 대동맥 근위부 치환술 - 1례 보고 -)

  • Moon, Hyeon-Jong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.30 no.1
    • /
    • pp.92-96
    • /
    • 1997
  • The prognosis of Behfet's disease characterized by recurrent orogenltal ulcers and ocular and skin lesions depends upon the complications in the central nervous system, the gastrointestinal tract And the vascular system. Cardiac involvement, especially aortic regurgitation, is quite uncommon and hemodynamic instability is usually treated with ope heart surgery. But serious postoperative complications had been reported in many cases, which are prosthetic valve detachment, paravalvular leakage, conduction disturbance, and false aneurysm. Many efforts to prevent the complications have been made such as application of cryopreseved homograft. We have described an experience of root replacement with homograft in d 39 year-old male patient for prosthetic valve detachment because of Behfet's aorlitis with a review of the literatures regarding treatment, complication, and prognosis.

  • PDF

Long-Term Clinical Results of Tricuspid Valve Replacement (삼첨판막 대치술의 장기간 임상성적)

  • 임상현;홍유선;유경종;강면식;김치영;조범구;장병철
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.328-334
    • /
    • 2004
  • There are only limited numbers of reports about long-term results of tricuspid valve replacement(TVR) with bioprosthetic and mechanical prostheses. We analyzed risk factors for tricuspid valve replacement and compared long-term clinical results of bioprosthetic and mechanical valves in tricuspid position. Material and Method: We reviewed 77 cases of TVR, which were performed between October 1978 and December 1996. Mean age was 38.8 15.9 years. Bioprostheses were implanted in 26 cases and mechanical prostheses were implanted in 51 cases. Result The operative mortality was 15.6% and late mortality was 12.3%. Survival for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 81.3% vs. 100%, 66.1% vs. 100%, 60.6% vs. 100% (p=0.0175). Free from valve related re-operation for bioprosthetic and mechanical valve group at 5, 10 and 13 years was 100% vs. 93.9%, 100% vs. 93.9% and 58.3% vs. 93.9% (p=0.3274). Linealized incidences of valve related re-operation for bioprosthetic and mechanical valve group was 2.27 %/patient-years and 1.10 %/patient-years. Risk factor analysis showed that presence of preoperative ascites, hepatomegaly larger than 2 finger breaths, poor preoperative NYHA functional class and number of tricuspid valve replacement were risk factors for early mortality, and the use of bioprosthetic valve and number of open heart surgery were risk factors for late mortality. Conclusion: Long-term survival of mechanical valve was superior to bioprosthetic valve in tricuspid position. We recommend mechanical valve in tricuspid position if the patient can be closely followed up.

Long Term Clinical Results of Triple Valve Replacement (삼중 판막 대치술의 장기 결과)

  • Yu, Song-Hyeon;Hong, You-Sun;Chang, Byung-Chul;Kang, Meyun-Shick;Lim, Sang-Hyun
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.675-679
    • /
    • 2005
  • Background: Clinical reports on replacement of all three (AV + MV + TV) valves are rare. Material and Method: From January 1992 to December 2003, 38 patients received triple valve replacement (aortic, mitral, tricuspid) at Yonsei Cardiovascular Center. Mean age of patients was $49.5\pm10.7 (28\~69)$ years, and 24 patients $(63.1\%)$ were female. Rheumatic valve disease was the most common cause of operation (n=37). Preoperative New York Heart Association functional class were II in 4, III in 24 and IV in 10. Fifteen patients (group 1) received triple valve replacement at their first operation. Twenty three patients (group 2) received one or more operations before tricuspid valve replacement (TVR). Seven patients received tricuspid valve annuloplasty at first operation and received TVR later. Result: Six patients died at hospital after operation $(15.8\%)$ and all these patients were in group 2. All patients in group I survived and were discharged. Three patients $(9.4\%)$ died during follow up periods. Most of the survivors had improved functional class (I in 22, II in 8, III in 1, IV in 1). During follow up period, there were 4 valve related complications. The 10-year survival rate was $68.8\%$ and survival rate for free from valve related event at 10 years was $85.5\%$. Conclusion: After triple valve replacement, most patients showed improvement of symptoms. And during follow up period, valve related complications and survival were acceptable. Therefore, if indicated, triple valve replacement is recommended before the patients' conditions get worse.

Mitral Reconstruction Using Prosthetic Ring in Mitral Valvular Heart Disease (승모판막질환에 있어서 인공판륜을 이용한 승모판막재건술의 임상적 고찰)

  • 나명훈;황경환
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.598-606
    • /
    • 1997
  • Among 136 patients having undergone mitral valve surgery from September of 1994 through August of 1995 in Sejong Heart Institute, forty four patients(18 males, 26 females) underwent mitral valve reconstruction using prosthetic rings and their clinical results were evaluated. Patients'ages ranged from 5 to 63 years(mean age 38.2 years). Mitral valvular diseases were due to rheumatic origin in 30 patients(68%), degenerative in 13(30%), and congenital in one patient(2%). Mitral regurgitation(MR) was in 33 patients(76%), mitral stenosis 2(5%), and mitral stenoinsufaciency 9 patients(19%). The patients were divided into Carpentier's functional groups : type I, 5 patients(11%) : type I, 24 patients(55%) ; type III, 4 patients (9%) i and mixed(II + III), 11 patients(25%). Average number of anatomic lesions of mitral valve per patient was 3.7. The techniques included prosthetic ring amluloplasty(44 patients, 32 Carpentier ring and 12 Duran ring), leaflet mobilization(24, 55%), chordae shortening(23, 52%), chordae transposition(23, 52%), commissurotomy(16, 35%), leaflet resection(9, 20%), papillary muscle splitting(8, 18%), and chordae reimplantation(1, 2%). Average 3.4 surgical procedures were applied on mitral valve per patient. There were two hospital mortality and one reoperation due to development of MR(grade III) after 2 weeks. During the mean follow up of 12 months, patients improved in terms of functional class of the New York Heart Association, which was mean 3.0 preoperatively and 1.3 postoperatively. Doppler echocardiographic studies showed adequate valve area(2.07$\pm$0.11 cm2 mean $\pm$standard error), improved ventricular contractiliy in 41 patients(93%), ab ence of MR in 23(53%), trace MR in 18(42%), and garde II MR in 2 patients(5%).

  • PDF

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF

Noninvasive assessment of pressure gradients across prosthetic heart valve by doppler ultrasound -A comparative studyof the duromedics bileaflet valves in mitral position and normal mitral valves- (도플러 초음파를 이용한 인공판막 상하의 압력차 측정에 관한 연구 -승모판막 치환에 사용한 Duromedics 인공판막과 정사인의 승모판막과의 비교연구-)

  • Jin, Seong-Hun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.223-229
    • /
    • 1987
  • Doppler echocardiography provides valuable information regarding prosthetic heart valve function rather than structure. There are three methods of expressing the severity of mitral valve obstruction: the transvalvular pressure gradient, effective valve area, and pressure half-time. Of these, the transvalvular pressure gradient [~p] can be determined by the measurement of maximum transvalvular blood flow velocity [V] according to the modified Bernoulli`s equation [gp=4V*]. Eleven patients, who underwent mitral valve replacement with Duromedics mechanical prostheses, and 17 normal persons were investigated. There were significantly higher calculated pressure gradients in prosthetic than normal mitral valves [9.*10*2.22mmHg-vs-3.26*0.99mmHg:p<0,01], and there was a inverse relationship between pressure gradient and prosthetic valve size [11.17*0.%mmHg in size 27mm and 29mm -v- 7.38*1.12mmHg in size 31mm and 33mm; r=0.85, p<0.01] The noninvasive Doppler technique should be useful in the diagnosis of prosthetic valve obstruction.

  • PDF

Aprotinin Therapy for Cardiac Operation in Adult -Full dose regimen- (개심술에서 아프로티닌의 효과 (고용량 요법))

  • 장운하;오태윤;김미혜
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.358-363
    • /
    • 1999
  • Background: Recently, many cardiac centers have been using aprotinin to reduce operative bleeding in cardiac operations using cardiopulmonary bypass. A variety of reports have confirmed the effectiveness of the drug in cardiac operations. In addition to the operations which could be considered to cause severe operative bleeding such as redo operation, long cardiopulmonary bypass operation and etc, the use of aprotinin is increasing in the field of primary cardiac operations. Varying doses of regimen have been introduced since the first report by Royston et al, and also various opinions on the effectiveness and safeness of the each regimen have been reported. We reviewed our own experience of the full dose aprotinin regimen(Hammersmith regimen) retrospectively. Material and Method: From October 1994 to February 1998, 40 cases of cardiac operative patients were randomized into two groups: aprotinin group(20 patients) which received a full dose aprotinin regimen and control group(20 patients) which did not receive aprotinin. To evaluate the degree of bleeding decrease, we analysed and compared the amount of postoperative 6 hours and 24 hours bleeding in the each group. To confirm the renal dysfunction, we measured the postoperative creatinine level. Result: In the amount of postoperative 6 hours bleeding, a statistically significant bleeding decrease was demonstrated in the aprotinin group compared to the control group(aprotinin group: 186${\pm}$40cc, control group:409${\pm}$69cc, P=0.010). Similar result was observed in the postoperative 24 hours(aprotinin group:317${\pm}$53cc, control group: 671${\pm}$133cc, P=0.024). Conclusion: We concluded that full dose regimen of aprotinin can remarkably reduce postoperative bleeding in cardiac operations without significant renal dysfunctions.

  • PDF