• Title/Summary/Keyword: 인공 삽입물

Search Result 69, Processing Time 0.028 seconds

Three-Dimensional Printing Technology in Orthopedic Surgery (정형외과 영역에서의 삼차원 프린팅의 응용)

  • Choi, Seung-Won;Park, Kyung-Soon;Yoon, Taek-Rim
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.2
    • /
    • pp.103-116
    • /
    • 2021
  • The use of 3-dimensional (3D) printing is becoming more common, and its use is increasing in the orthopedic surgery. Currently, there are four major methods of using 3D printing technology in orthopedic surgery. First, surgical planning simulation using 3D printing model; second, patient-specific surgical instruments; third, production of customized prosthesis using 3D printing technique; fourth, patient-specific prosthesis produced by 3D printing. The areas of orthopedic surgery where 3D printing technology can be used are shoulder joint, spine, hip and pelvis, knee joints, ankle joint, and tumors. Since the diseases and characteristics handled by each area are different, the method of using 3D printing technology is also slightly different in each area. However, using 3D printing technology in all areas can increase the efficiency of surgery, shorten the surgery time, and reduce radiation exposure intraoperatively. 3D printing technology can be of great help in treating patients with particularly complex and difficult orthopedic diseases or fractures. Therefore, the orthopedic surgeon should make the most of the benefits of the 3D printing technology so that patient can be treated effectively.

Evaluation of Metal Artifact Reduction for Orthopedic Implants (O-MAR) on Radiotherapy Treatment Planning (방사선 치료 계획 시 O-MAR (Metal Artifact Reduction for Orthopedic Implants) 적용의 유용성 평가)

  • Won, Huisu;Hong, Joowan;Kim, Sunyoung;Choi, Jaehyock;Cho, Jaehwan;Yang, Hanjoon;Lee, Jin;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.217-223
    • /
    • 2014
  • The aim of this study is evaluation of dose distribution on radiation therapy planning system with the CT image of high-density material inserted phantom. Gammex 467 Tissue Characterization Phantom is used to acquire an image similar to the human tissues and insert a Titanium to generate metal artifact. The acquired images were reconstructed with Metal Artifact Reduction for Orthopedic Implants (O-MAR). By using the treatment planning system, the volume was analyzed and dose distribution was extracted. Photon dose distribution in linear accelerator was measured by the $MapCHECK^{TM}$ and compared with planned and measured dose distributions. In result of the comparative analysis, when artifact is generated by Titanium, The volume applied O-MAR was increased 6.8% to BR-12 Breast and 40.2% to LV 1 Liver. After O-MAR was used, Dose distribution was higher 1.4 to 1.6% than before. Consequently, The artifact caused by metal objects should be removed if possible, and after that used in the radiotherapy treatment plan can be considered to reduce errors.

Tumor Prosthetic Arthroplasty and Arthroplasty with Bone Cement for the Metastatic Malignant Bone Tumor in the lower Extremity (하지 관절 부위에 발생한 전이성 종양 환자의 종양 대치물 및 골시멘트와 인공관절 삽입술)

  • Yang, Jun-Young;Lee, June-Kyu;Hwang, Deuk-Soo;Shin, Hyun-Dae;Kwak, Sang-Koo;Kim, Kyung-Cheon;Nam, Dae-Cheul
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.12-17
    • /
    • 2003
  • Purpose: In this report we are going to discuss about the functional evaluation and the outcome of treatment of metastatic tumor in the lower extremities treated with tumor prosthetic arthroplasty. Materials and Methods: This report is based on nine patients diagnosed as a metastatic tumor and treated by tumor prosthetic arthroplasty, from June 1998 to December 2001. Age of the patients ranged from 49 to 63 with the average of 56.3. The average follow up period was 23.4 months. Two patients had lung cancer, three had breast cancer, two had renal cancer, one colon cancer, and one had multiple myeloma. All these were primary cancers. The site of metastasis were six in proximal femur, two in distal femur, and one in proximal tibia. Tumor excision was performed after biopsy in following the principle of primary tumor management. Excision with wide surgical margin was tried as possible could. Six cases were treated with tumor prosthesis, and the other three cases were reconstructed with bone cement and arthroplasty. Results: The functional evaluation in the extremities at the last follow up was performed on Enneking evaluation score with 6 categories. The highest scored 26, and the lowest scored 10, with an average of 19.5. A case in which the patient died 15 days after the operation was excluded from the evaluation. Among the categories, emotional acceptance to postoperative function and pain relief were highly scored. At the final follow up, seven patients survived, and one colon cancer patient died 68 days after operation. Conclusion: Metastatic tumor occurring in joints of lower extremities could be treated in accordance to the treatment principle of primary tumor. By insertion of tumor prosthesis, we can get satisfactory results of function in the lower extremity and pain relief especially. So, this aspect of medical favor must be considered in treating patients.

  • PDF

Reduction of Metal Artifact by Using VAT-SEMAC in MRI (VAT-SEMAC을 이용한 보철물에 의한 허상 감소)

  • Kim, Hyung-Tae;Lim, Jong-Nam;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.227-232
    • /
    • 2019
  • MRI examination for patients with metal objects has in poor image quality. Metallic implants can result in poor image because magnetic susceptibility causes signal loss and distortion and makes poor imaging, which is called magnetic susceptibility artifact or metal artifact. There are several approaches to reduce metal artifacts. In this study, we study the reduction of metal artifact by VAT and SEMAC techniques. A metal implant used for orthopedic surgery was attached to the phatom and the distortion caused by the artifact was measured under T1WI and T2WI protocols. Several techniques of VAT only and VAT and SEMAC for the reduction of metal artifact were compared. The metal artifact showed a reduction of at least 8% to a maximum of 26% in the VAT-SEMAC. The VAT-SEMAC technique can be applied to patients with orthopedic implants to improve image quality. If scan time and image quality are simultaneously considered in VAT-SEMAC technique, metal artifact will be reduced in clinical practice.

Osteolytic Lesion of the Fibular Head after Cemented Total Knee Arthroplasty (슬관절 전치환술 후 비골 두에 발생한 골용해성 병변)

  • Lee, Chae-Chil;Park, Ki-Bong;Hwang, Il-Yeong;Yang, Doo-Guen
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.1
    • /
    • pp.87-92
    • /
    • 2021
  • The radiographic findings of an osteolytic lesion in the knee may indicate numerous possible impressions. Furthermore, osteolysis is a possible cause if there is a surgical history of total knee arthroplasty (TKA). The authors diagnosed osteolysis of the fibular head after aseptic loosening of the tibial component of a cemented TKA in an 83-year-old female patient who visited with right knee pain and report their treatment with revision TKA along with a literature review.

A Study of the Metal Artifact Reduction using Dual Energy CT : Clinical Applications of Dual Energy and MAR Algorithm (Dual Energy CT를 이용한 금속물질 인공물 감소방법 : Dual Energy와 MAR알고리즘의 임상적 응용)

  • Park, Ki Seok;Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.273-279
    • /
    • 2021
  • Metal material inserted into the body have a large difference in density from human tissues or bones around the Metal during CT scans.. Therefore, the Metal material inserted into the body produces Artifact. Metal Artifact, which occurs around Metals, can degrade the quality of CT images, causing confusion when medical team diagnose lesions. Through this experiment, we confirm that the occurrence of Artifacts decrease by using Dual energy CT and MAR algorithm in Single source Dual energy CT. We also want to present basic data on clinical application methods by comparing and analyzing the characteristics of images obtained by each method. Using GE 750HD CT, artificial implants were scanned using general method and Dual energy. Then we apply the MAR algorithm to each image obtained. And all previously acquired images were compared and analyzed the characteristics of the examination, such as image quality evaluation and dose evaluation. Images with MAR algorithm and Dual Energy confirmed a decrease in Metal Artifact. Images with MAR algorithm have reduced Metal Artifact, but have the disadvantage of distorting the details of artificial joint implants. On the other hand images teseted with Dual Energy have the advantage of being able to implement details than those applied with MAR algorithms, it takes longer to reconstruct the image and the exposure dose was about four times higher than those applied with MAR algorithm. In order to locate Metals, such as the post-operative follow-up period, it is useful to apply MAR algorithm to obtain images. And it is more useful to examine with Dual Energy when micro lesion identification, such as cardiac examination, and surgical planning or when tests are performed in diagnostic way.

The Effects of Physical States of Phospholipids on $Ca^{2+}$-ATPase Activity of Biological Membranes (지질의 물리학적 성상이 $Ca^{2+}$-ATPase 활성도에 미치는 영향)

  • Hah, Jong-Sik
    • The Korean Journal of Physiology
    • /
    • v.22 no.2
    • /
    • pp.163-177
    • /
    • 1988
  • The $Ca^{2+}-ATPase$ of sarcoplasmic reticulum (SR) was solubilized and reconstituted into a mixture of phosphatidylcholine (PC) and phosphatidylethanolamine (PE) of varying ratios in order to assess the effect of physical states of phospholipids on the incorporation and functions $Ca^{2+}-ATPase$. On the basis of the spectral data of Ca-arsenazo III, the $Ca^{2+}$ uptake of SR was increased linearly as the PC content increased in the reconstituted vesicles. The ATP hydrolysis activity also increased as PC content increased up to 25% and then decreased slightly as the PC content further increased. On the other hand the incorporation of $Ca^{2+}-ATPase$ into the reconstituted vesicls occured maximally at 25% PC and 75% PE mixture which is known to have a non-bilayer structure in reconstitution system. From the above results it is clear that preexisting defects in the lipid bilayer promote protein incorporation into the bilayer during reconstitution and lamellar structure of the bilayer facilitates the $Ca^{2+}-ATPase$ function.

  • PDF

A Convergence Study on the Characteristics of Length of Hospital Stays of Injured and Traumatic Death Patients - Based on the Korea National Hospital Discharge Injury Survey Data (손상 및 외상 사망 환자의 재원일수 특성에 관한 융합 연구 -퇴원손상심층조사자료를 중심으로)

  • Song, Yu-Rim;Lee, Moo-Sik;Kim, Doo-Ree;Kim, Kwang-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.87-96
    • /
    • 2017
  • This study was carried out to provide basic data for prevention of death from injuries and traumas by analyzing the characteristics of length of hospital stay of patients with injuries and traumas, utilizing in-depth investigation data of discharged injuries. The study subjects were 233 patients discharged from January 1 to December 31 in 2014 whom the final treatment result was 'death' and the main diagnosis were injuries and accidental external causes(S00-T98). According to the research findings, the length of hospital stay of females was longer than that of males. Based on the main diagnosis, the longest length of hospital stay had complication of other internal prosthetic devices, implants and grafts(T85). In conclusion, it is necessary to develop a policy to identify the factors affecting the length of hospital stays of patients and to manage them intensively.

Measurement of Material Properties of Composites under High Temperature using Fiber Bragg Grating Sensors (광섬유 브래그 격자 센서를 이용한 고온용 복합재료의 물성 측정)

  • 강동훈;박상욱;김수현;홍창선;김천곤
    • Composites Research
    • /
    • v.16 no.6
    • /
    • pp.41-47
    • /
    • 2003
  • Composites are widely used for aircraft, satellite and other structures due to its good mechanical and thermal characteristics such as low coefficient of thermal expansion(CTE), heat-resistance, high specific stiffness and specific strength. In order to use composites under condition of high temperature, however, material properties of composites at high temperatures must be measured and verified. In this paper, material properties of T700/Epoxy were measured through tension tests of composite specimens with an embedded FBG sensor in the thermal chamber at the temperatures of RT, $100^{\circ}$, $200^{\circ}$, $300^{\circ}$, $300^{\circ}$. Through the pre-test of an embedded optical fiber, we confirmed the embedding effects of an optical fiber on material properties of the composites. Two kinds of specimens of which stacking sequences are [0/{0}/0]$_{T}$. and [$90_2$/{0}/$90_2$]. were fabricated. From the experimental results, material property changes of composites were successfully shown according to temperatures and we confirmed that fiber Bragg grating sensor is very appropriate to strain measurement of composites under high temperature.

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.