Image Evaluation Analysis of CT Examination for Pedicle Screw Insertion (척추경 나사못 삽입술 CT검사의 영상평가 분석)

  • Hwang, Hyung-Suk;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2022
  • The purpose of this study was to insert a pedicle screw into a pig thoracic vertebrae, a general CT scan(Non MAR), and a thoracic axial image obtained with the Metallic Artifact Reduction for Orthopedic Implants (O-MAR) to reduce artifacts. The image obtained by reconstructing the algorithm (Standard, Soft, Bone, Detail) was used using the image J program. Signal to noise ratio(SNR) and contrast to noise ratio(CNR) were compared and analyzed by obtaining measured values based on the given equation. And this study was to investigate tube voltage and algorithm suitable for CT scan for thoracic pedicle screw insertion. As a result, when non-MAR was used, the soft algorithm showed the highest SNR and CNR at 80, 100, 120, and 140 kVp, On the other hand, when MAR was used, the standard algorithm showed the highest at 80 kVp, and the standard and soft algorithms showed similar values at 100 kVp. At 120 kVp, the Soft and Standard algorithms showed similar values, and at 140 kVp, the Soft algorithm showed the highest SNR and CNR. Therefore, when comparing Non-MAR and MAR, even if MAR was used, SNR and CNR did not increase in all algorithms according to the change in tube voltage. In conclusion, it is judged that it is advantageous to use the Soft algorithm at 80, 100, 120, and 140 kVp in Non MAR, the Standard algorithm at 80 and 100 kVp in MAR, and the Soft algorithm at 120 and 140 kVp. This study is expected to serve as an opportunity to further improve the quality of images by using selective tube voltage and algorithms as basic data to help evaluate images of pedicle screw CT scans in the future.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Simulation Methods of Electromagnetic Wave Specific Absorption Rate (SAR) and the Simulation Results of Human Head Model with Dental Implants in 5G Frequency Band (전자파 흡수율(SAR) 시뮬레이션 기법과 5G 주파수 대역에서의 인공 치아가 삽입된 인체 머리 모델의 전자파 흡수율 시뮬레이션 결과)

  • Kim, Chang-Gyun;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.22 no.3
    • /
    • pp.854-857
    • /
    • 2018
  • It becomes important to analyze the effects of electromagnetic wave on human body, as various wireless equipments are widely used in daily life. SAR (specific absorption rate) is a parameter of the effects of electromagnetic wave on human body. However, it considers only human tissues, and it is difficult to evaluate the effects of electromagnetic wave when metal artifacts are inserted such as dental implants. This paper introduces a method to simulate SAR, and gets its simulated results. Simulated SAR of human head model with dental implants in 30 GHz 5th generation mobile communications (5G) frequency band is $2.50{\times}10^{-3}W/kg$ in maximum and $8.58{\times}10^{-7}W/kg$ in average. These values are absolutely below 1.6 W/kg Korean domestic SAR limit.

A Study on Computer Aided Surgical Simulation Method for Total Hip Arthroplasty (컴퓨터 응용 인공고관절 모사 시술 방법 연구)

  • Kim Sang Hoo;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.455-464
    • /
    • 2004
  • Total hip arthroplasty(THA) considerably depends on high-experienced doctors because of high difficulty of the operation. Selection of acetabular cup's and femoral implant's position is closely related with success or failure of THA. Nevertheless the selection has usually depended on doctor's eye measurement, which makes the position accuracy of artificial joint lower after THA, often resulting in revision of THA. The present study determined a method to select accurately the position of acetabular cup and femoral implant through surgical simulation with 3D characteristic geometrical information of patient's pelvis and femur. We examined the change of femoral anteversion angle and neck-shaft angle accompanied by the change of acetabular cup's position and the insertion position of femoral implant. As result of analyzing geometrical information through different surgical simulations, we found that it was possible to select the accurate position of acetabular cup and femoral implant. It is expected to help doctors get experienced in THA operation through repetitive surgical simulations using the method suggested in the study.

Analysis of the artifact reduction rate for the types of medical metals in CT with MAR algorithm (CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석)

  • Kim, Hyeon-ju;Yoon, Joon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.655-662
    • /
    • 2016
  • We investigated on the usefulness of MAR algorithm by making a comparison of the CT value between before and after applying the MAR algorithm in dual energy CT, using the various kinds of medical metals, causing the artifact to lead to the low image quality. As a result, the artifact was reduced in most cases (P<0.05); in particular, the artifact was highly reduced (P<0.05) using high density material, like alloy-stainless (reduced by 78.1%) and platinum, for example GDC coil (reduced by 76.1%). The effect of decreasing the Black hole artifact was outstanding in both the alloy-stainless and alloy-titanium (P<0.05). However, in case of GDC coil-a type platinum, white streak artifact was reduced effectively (P<0.05). Therefore, in case of patients who have medical metals inserted, we think that high-quality image information can be provided by decreasing the artifact caused by high density material through MAR algorithm in dual energy CT.

Structural Analysis and Design of Artificial Hip Joint by Using Finite Element Method (유한요소법을 이용한 인공 고관절의 역학적 거동 해석 및 설계)

  • 정재연;황운봉;하성규
    • Composites Research
    • /
    • v.12 no.5
    • /
    • pp.98-109
    • /
    • 1999
  • An investigation has been performed to develop a nonlinear finire element method for the analysis of the long-term behavior of an artificial hip joint. The three dimensional multi-layered brick element is used to analyze the design performances of hip prodtheses with various materials and the thick laminated composite hip prostheses with various layup sequences. The used element can accommodate the varying material properties of the element and allow the ply-drop-off along the eleement edge. The nonlinear finite element analysis program has been verified by the comparison with the exact solution of the bean problem subjected to uniaxial loading. By using the program, the density changes and strength ratios of artificial hip joint are calculated according to the hip prosthesis materials and the layers of composite hip prosthesis. The numerical results are easily applied to evaluate design performances of a hip prosthesis, and decrease the difficulty and time of hip prosthesis design.

  • PDF

Artificial Organ Transplantation With 4D Printing (4D 프린팅을 이용한 인공장기이식)

  • Yeo, Da-Hye;Lim, Da-Geom;Park, Cheol-Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.07a
    • /
    • pp.343-345
    • /
    • 2021
  • 본 논문에서는 4D 프린팅을 이용한 인공장기이식에 대해 소개한다. 여러 외부적 요인에 대처할 수 없었던 3D 바이오 프린팅의 단점을 보완하여 자가변환 및 자가조립이 가능한 재료를 3D프린터로 찍어낸 다음, 그 물체가 주변환경에 의해 스스로 모양이 변화하는 기술인 4D 프린팅을 이용한다. 또한, 4D 프린팅은 변형이 가능한 특수 소재를 사용함으로써 시간이 지나면 출력한 결과물의 모양이 변하게 되고, 시간 및 온도·습도·압력 등의 외부적인 요인에 스스로 능동적으로 대처할 수 있다. 본 논문에서는 4D 프린팅 기술로 제작한 작은 인공장기를 인체에 삽입함으로써 수술 후 감염 및 합병증 등의 부작용을 최소화할 수 있고 수술 시간을 크게 단축할 수 있다는 면에서 우수함을 보인다.

  • PDF

Effect of stem design on contact pressure distribution of end-of-stem in revision TKR (슬관절 재전치환술용 경골삽입물 형상이 접촉압력 분포에 미치는 영향)

  • Kim Y.H.;Koo K.M.;Kwon O.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.179-180
    • /
    • 2006
  • In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The stem models with various stem lengths, diameters and frictional coefficients, and press-fit effects were considered. The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher frictional coefficient increased both peak contact pressure and the highest Von-Mises stress values. We hypothesized that peak contact pressure and Von-Mises stress distribution around the stem, may be related to the stem end pain. The results of this study will be useful to design the stem endand reduce the end-of-stem pain in revision TKR.

  • PDF

Total Hip Arthroplasty in Patients with Avascular Necrosis of the Entire Femur (전체 대퇴골에 발생한 골괴사 환자에서 인공 고관절 전치환술)

  • Yi, Seung Rim;Im, Se Hyuk;Park, Sang Hoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.281-286
    • /
    • 2019
  • Avascular necrosis (AVN) is defined as the cellular death of bone and bone marrow components due to the loss of blood supply, and associated with post-traumatic or non-traumatic events. AVN usually involves the epiphysis of a long bone, such as the femoral and humeral heads, which are susceptible to osteonecrosis. Many studies have been conducted but they were restricted to investigations of femoral head avascular necrosis. The presence of osteonecrosis in the proximal femur may impair biological fixation after total hip arthroplasty. We report a 56-year-old male patient with avascular necrosis located not only at the femoral head, but also in the entire femur, including the medullary cavity, who underwent total hip arthroplasty 2 years earlier along with a review of the relevant literature.