• 제목/요약/키워드: 인공 고관절

검색결과 61건 처리시간 0.026초

고관절 인공관절 치환술 환자의 보행능력 증진을 위한 문제해결 접근: ICF Tool을 적용한 단일사례연구 (The Problem-Solving Approach for Improving Walking Ability in Patient with Total Hip Replacement: Applied ICF Tool for Case Study)

  • 송현승;김선엽
    • 대한정형도수물리치료학회지
    • /
    • 제21권2호
    • /
    • pp.63-71
    • /
    • 2015
  • Background: The purpose of the study, using the ICF Tool in the process of rehabilitation of artificial joint replacement surgery of the hip joint, goal setting and understanding of the problem, through the process of creating intervention strategies, useful clinical practical course for rehabilitation I try to present the data. Methods: Fracture was the left total hip replacement (THR) surgery due to women of 76 years old. I proceed in order screening, evaluation, diagnosis, prognosis, treatment planning and intervention, re-screening. Needs of the patient was walking short distances for using the toilet. In order to improve was carried out arbitration, after you have created a list of issues that limit the ability to walk short distances. Results: It was revealed improved results in self-paced walk test (SPWT) and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) was used to examine whether the goals. In addition, MMT VAS, DGI, and TUG is a detailed goal was improved. Conclusions: It can be shown objectively the results of interventions performed for the purpose of solving the problem which is grasped through clinical Practical course for short-range walking ability enhance patient THR. I considered practical clinical course using the ICF Tool would be useful.

  • PDF

인공 고관절 골두용 세라믹 복합재료에 대한 세라믹-세라믹 접촉 마멸 특성 분석 (Ceramic-Ceramic Wear Zirconia/Alumina Composites For The Application Of Total Hip Joint Implant)

  • 김환;이권용;김대준;이명현;서원선
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2004년도 학술대회지
    • /
    • pp.355-361
    • /
    • 2004
  • Ceramic femoral heads in the total hip replacement have been developed to reduce the polyethylene liner wear, Alumina and zirconia (3Y-TZP) having the excellent tribological properties are coupled against acetabular cups of polyethylene and are used in clinical application worldwide. However, alumina has a risk of catastrophic failure, and zirconia has the low temperature degradation in spite of enhanced fracture toughness. Recently, novel zirconia/alumina composite is very attractive due to the low temperature degradation (LTD)-free character and high fracture toughness. In the present study, we focus on the wear of ceramic on ceramic, which are able to be used as femoral heads and acetabular cups. Therefore, LTD-free zirconia/alumina composites with three compositions are made in a form of disk and cylinder, and the wear of the composites is performed on pin-on-disk type wear tester. The wear is conducted with or without lubricant. All the composites fabricated with the different composition show the good wear resistance.

  • PDF

무시멘트형 대퇴스템에서 원위부 압박 정도에 따른 생체역학적 특성 (Biomechanical characteristics of the distal filling effects in cementless femoral stem)

  • 박상석;박재원;채수원
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.387-392
    • /
    • 2000
  • In cementless total hip replacement(THR), an initial stability of the femoral component is important to long term fixation of femoral stem. The initial stability has close relationship with the relative displacement of prosthesis and spongy bone at the proximal of femur. After implantation of the prosthesis. the surrounding bone is partially shielded from load carrying and starts to resort. Stress shielding is the cause of the loss of proximal bone. Assessing stress distribution of femur is important to predict stress shielding. The initial stability and the stress shielding were investigated for two loading conditions approximating a single leg stance and a stair climbing. Three types of stems were studied by the finite element method to analyze the biomechanical effects of distal filling of cementless femoral stems, Three types of stems employed are a distal filling stem, a distal flexible stem, and a distal tapered stem.

  • PDF

신장 암의 비구주위 단독 전이 환자에서 종양절제 및 재건술 - 증례 보고 - (Tumor Resection and Reconstruction in Periacetabular Single Metastases of Renal Cell Carcinoma - A Case Report -)

  • 신덕섭;한동성
    • 대한골관절종양학회지
    • /
    • 제13권2호
    • /
    • pp.113-118
    • /
    • 2007
  • 골반 골에 생기는 종양은 복잡한 해부학적 구조와 체부 깊숙이 위치하는 특성으로 인하여, 상당히 커진 후에야 발견되는 경우가 많아서 진단이 늦어지고, 수술이 어려워지는 경우가 많이 있다. 특히 비구 주위에 발생한 종양은 종양의 제거 후에 고관절의 기능을 유지 할 수 있는 재건술의 방법이 극히 제한되어 있고, 수술도 어려우며, 재건술의 예후 또한 예측하기 어렵다. 저자는 신장암이 골반 골 비구 주위로 단독 전이 된 환자의 광범위 종양절제 후 저온 가열 처리한 자가골 과 인공고관절로 재건 한 증례를 보고한다.

  • PDF

대퇴골 근위부 골흡수가 인공 고관절 대퇴 stem에 미치는 응력에 관한 연구-FEM을 이용한 분석 (A Finite Element Analysis of Stress on the Femoral Stem with Resorption of Proximal Medial Femur after Total Hip Replacement)

  • 김성곤
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권2호
    • /
    • pp.183-188
    • /
    • 1994
  • In clinical orthopaedics, bone resoption in the cortex is often seen post operatively on X-rays or bone densitometry after total hip replacement (THR) in the form of cortical osteoporosis or atropy. Stress shielding of bone occurs, when a load, normally carried by the bone alone, is shared with an implant as a result, the bone stresses are abnormal and with remodelling analysis this may cause extensive proximal bone resoption, possibly weakening the bone bed to the point of failure. The author made finite element models of the cemented and non-cemented type implanted femoral stem with bone resorption of the proximal medial femur and studied the feed back effect of the various degree of bone resoption to THR system by parametric analysis on the stress of the femoral stem and interface. The results of the present finite element analysis implied that the extent of proximal bone resorption has the effect of more increasing stress on the distal stem tip, cement mantle and interface in both type of femoral stem and this high distal stress possibly can cause the mechanical failure of loosening or failure after THR.

  • PDF

인공 고관절시술자환자의 중심동요 특성에 관한 연구 (Investigation of postural sway characteristics of patients after total hip replacement)

  • 강창수;신승헌;민병우
    • 대한인간공학회지
    • /
    • 제14권2호
    • /
    • pp.87-104
    • /
    • 1995
  • This research investigates the possibility of using the postural sway of patients as a reference for measruing the progress of the disease and healing of patients who received total hip replacement; the progress of the disease by X-ray pictures, the pain felt by the patients, and the difficulties encountered in moving the joints. The measurements on the force platform were taken during a 25 second period standing on both feet and during a 5 second period standing on one foot with both eyes open. The result of the research showed that the trace and area of the overall length of postural sway was a good indicator which represented the healing progress of the patients who received total hip replacement, and the weakening of the muscles and the recovery process for 3 or 4 month after receiving the operation, which did not appear on X-ray pictures, were exhibited on the postural sway. Finally, standing on a single foot represented the healing progress much better than standing on both feet.

  • PDF

SPECT/CT에서 인공고관절에 대한 감쇠보정지도(Attenuation Map)의 매개변수 변화에 따른 금속 인공물(Metal Artifact)의 영향 평가 (Evaluation of the Effect of Metal Artifacts Varying the Parameters of the Attenuation Map for the artificial Hip Joint in SPECT/CT)

  • 김상규;김정열;박민수;조승현;임한상;김재삼
    • 핵의학기술
    • /
    • 제18권2호
    • /
    • pp.3-7
    • /
    • 2014
  • CT를 기반으로 감쇠보정이 시행되는 SPECT/CT 검사에서는 금속 삽입물에 의한 선속경화현상으로 인접한 부위의 과대평가를 유발하며, 영상의 질을 저하시킨다. 이에 대해, 본 연구에서는 인공고관절이 삽입된 팬텀을 이용하여 감쇠보정지도의 매개변수 변화에 따른 금속 인공물이 SPECT/CT 영상에 미치는 영향을 알아보고자 한다. SPECT/CT 장비는 Siemens사의 Symbia T16을 사용하였다. SPECT/PET 팬텀에 인공고관절을 삽입하고, CT영상에서 Bright Streak 영역에 직경 17 mm의 구를 배후방사능 대비 8배가 되도록 Tc-99m을 채웠다. 이후 감쇠보정지도에서 Wide Beam Coefficient[수동모드(0.1~0.9), 자동모드]변화에 따른 열소와 배후방사능의 계수를 측정하였고, 고관절의 유무에 따라 Metal과 Non-Metal의 병소 대 배후방사능 비(Region to Background Ratio, RBR)를 산출 및 비교 분석하였다. 수동모드의 값이 증가할수록 Metal과 Non-Metal의 열소 계수는 증가하는 경향을 나타냈으며, 수동모드 0.4와 0.5에서 두 군과의 열소 계수비가 가장 일치하게 나타났다(수동모드 0.4=1.001, 0.5=0.999). 또한 $RBR^{Metal}$$RBR^{Non-Metal}$의 비는 자동모드에서 1.135이였고, 수동모드 0.4와 0.5에서 통계적으로 유의한 차이를 보이지 않았다(0.4=0.999, 0.5=1.028, p=0.78). 감쇠보정지도에서 Wide Beam Coefficient의 자동모드는 13.52% 과 보정 되는 것을 알 수 있었으며, 수동모드 중 0.4와 0.5에서 인공물에 의한 과 보정을 최소화 할 수 있었다. 이를 활용하여 환자에게 적용하기 위해서는 추가적인 연구가 이루어져야 할 것이며, 고관절전치환술 환자의 인공고관절 주변에서 금속 인공물에 의한 과 보정을 감소시켜 진단능을 향상시킬 수 있을 것으로 사료된다.

  • PDF

스티칭 기법을 이용한 대퇴골 방사선검사 시 확대 표식자 위치 및 스티칭 범위 변화가 영상에 미치는 영향 (The Effect of the Position Change of the Magnification Marker and the Stitching Range on the Image in the Examination of the Femur Radiography Using Stitching Technique)

  • 홍성우;주영철;김승혁;고예원;김종석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.331-336
    • /
    • 2020
  • In this study, we would like to examine the effect of the location of the magnification marker and the change in the stitching range on the magnification marker and the expansion of the anatomical structure in the examination of femoral stitching radiation using the stitching technique, and to find out the usability of the femoral stitching radiation examination in the preoperative examination for THRA. The measured values measured by 5 researchers were summed and presented through descriptive statistics. When the position of the magnification marker was changed, the average value of the measured value was in the range of 113.54 to 113.90 mm. The anatomical structures of the femur were measured in the range of 57.24 to 57.78 mm, 27.20 to 27.56 mm, and 70.11 to 70.81 mm, respectively. This showed a similar deviation from the expansion rate of previous related papers using markers. Therefore, it is considered that femoral stitching X-ray examination using magnification markers can be used for preoperative examination for THRA.

무릎인공관절 단축범위(Single-Radius) 수술자와 다축범위(Multi-Radius) 수술자의 운동역 학적 및 운동생리학적 비교분석 (Biomechanical and Physiological Comparative Analysis of the Single-Radius Knee Arthroplasty Systems and Multi-Radius Knee Arthroplasty Systems)

  • 진영완;곽이섭
    • 생명과학회지
    • /
    • 제18권11호
    • /
    • pp.1532-1537
    • /
    • 2008
  • 무릎인공관절 단축범위 수술자와 다축범위 수술자를 대상으로 영상분석과 근전도 분석 그리고 운동생리학적 분석을 통하여 얻은 결과는 다음과 같다. 한 계단 오르기와 내리기 동안 소요시간은 대상자들 간에 통계적으로 큰 차이(p=0.380, p=0.171)는 없었지만 평균에서는 약간의 차이가 나타났다. 단 축범위 수술자가 다축범위 수술자보다 오르기와 내리기에서 평균속도가 빠른 것으로 나타났다. 한 계단 오르기 동안 고관절의 각속도, 무릎의 각속도, 발목의 각속도는 세 관절 모두 통계적으로는 유의한 차이(p=0.078, p=0.095, p=0.069)는 없었지만 평균의 비교에서는 단축관절 수술자가 다축관절 수술자보다 빠르게 나타났다. 한 계단 오르기 동안 관절의 최대 토크는 통계적으로 차이(p=0.052, p=0.096, p=0.134)는 나타나지 않았으나 평균의 비교에서는 단축관절 수술자가 다축관절의 수술자보다 각관절의 토큐가 모두 크게 나타났다. 굴곡과 신전으로만 움직이게 단축으로 제작된 인공관절에서는 볼 수 없는 변인으로서 연구의 의미가 있다고 사료된다. 계단 오르기와 내리기 동안 외전과 내전이 일어나는 각도를 알아본 결과 통계적으로는 큰 차이는 없었으나(p=0.103) 계단 오르기 동작 ($6.2^{\circ},\;7.8^{\circ}$)이 내리기 동작($5.8^{\circ},6.4^{\circ}$)보다 약간 크게 나타났다. 다축범위 수술자와 단축범위 수술자의 등장성 수축 시 하지의 근육변화를 알아보기 위하여 $15^{\circ}-75^{\circ}$ 사이의 무릎을 펴는 동안 VM, VL, RF, BF, ST의 근육들의 EMG값을 비교해본 결과 통계적으로 유의한 차이(P<0.05)가 나타났다. Table 5에서 보면 다축범위 수술자와 단축범위 수술자간에 대퇴사두근과 무릎오금근에서 유의한 차이(p<0.05, p<0.01)를 나타내고 있다. 무릎을 펴는 등장성 수축 동작에서 VM EMG값은 단축범위 수술자가 다축범위 수술자보다 $31^{\circ}-45^{\circ}$ 그리고 $61^{\circ}-75^{\circ}$에서 더욱 크게 나타났다. BF EMG값은 모든 구간에서 단축범위 수술자가 다축범위 수술자보다 크게 나타났다. 서로 다른 4그룹에서 운동 강도별 피험자의 체지방율의 변화는 젊은 일반군(C), 노인군(E), 단축범위 수술자(S), 다축범위 수술자(M) 에서 운동시기별 측정값의 통계적 유의한 차이는 나타나지 않았으나, C 그룹에서 시기별 체지방률이 감소하였고, 고강도 운동인 HI 시기에 가장 낮은 값을 나타내었다. 반면에 E, S 및 M 그룹에서는 시기별 감소하는 경향은 있었으나, 증가된 곳도 있고 HI 시기에서는 모든 그룹에서 감소하였다. 하지만 모든 시기에서 통계적인 차이를 나타내지 않았다. 서로 다른 4그룹에서 운동강도별 피험자의 안정시대사량의 변화는 그룹별 용이한 비교를 위하여 체표면적으로 나눈 값으로 표기하였다. C 그룹에서 시기별 안정 시 대사량 값이 증가하여 저강도 운동 후 가장높은 값을 보였고 통계적으로도 유의하게 증가함을 알 수 있었다(p<0.05). 서로 다른 4그룹에서 운동 강도별 피험자의 평균에너지 지출량의 변화는 운동 중과 운동 후 30분간의 에너지 지출량의 평균값을 나타낸 것으로 시기별 C 그룹에 대하여 다른 그룹을 비교 하였다. 우선 고강도 운동 시 C 그룹에 비해 E, S, M 그룹에서 낮은 에너지 소비량 값을 보였고, 모든 그룹에서 통계적으로 낮은 값을 보였다(p<0.05). 그리고 이러한 결과는 저 강도 운동에서도 같은 경향을 보이며 나타났는데, 저강도 운동 시 평균 에너지 지출량은 C그룹에 비하여 E, S, M 그룹에서 낮은 에너지 소비량 값을 보였다. 무릎인공관절 단축범위 수술자와 다축범위 수술자를 대상으로 운동역학적인 변인과 운동생리학적 변인을 동시에 병행하여 연구를 시도한 결과 우선 실험상의 어려움들이 많이 나타났다. 현재는 인공관절 수술이 두 종류의 형태뿐만 아니라 재료가 다른 여러 종류의 인공관절도 제작되고 있다. 계속적으로 추가적인 연구가 실시되어야 할 것으로 사료된다.

심장이식후에 발생한 외과적 합병증 - 단일 센터 경험 - (Surgical Complications in Heart Transplant Recipients - A Single Center Experience -)

  • 박국양;박철현;전양빈;최창휴;이재익
    • Journal of Chest Surgery
    • /
    • 제42권6호
    • /
    • pp.719-724
    • /
    • 2009
  • 배경: 심장이식이 최근 증가하면서 거부반응과 감염외의 외과적합병증도 증가하고 있다. 이 논문에서는 한 외과의에 실시된 심장이식후에 발생한 외과적합병증을 보고하고자 한다. 대상 및 방법: 1994년 4월부터 2003년 9월까지 실시된 37명의 심장이식환자를 대상으로 하였으며 심장이식의 적응은 확장성 심근증, 허혈성심근증, 판막심근증, 가족력심근증 등이었다. 결과: 총 15명의 이식환자에서 20예의 합병증이 발생하였으며 실시된 외과적 수술의 종류는 출혈로 인한 재개흉(5), 심낭액저류배액술(4), 인공박동기거치술(1), 아스페르질루스증에 의한 우하엽절제술(1), 요석제거술(1), 담낭제거술(1), 직장주위절개술(1), 부비동배액술(1), 고관절치환술(1), 치주비대에 의한 치주절개술(1), 뇨도절개술(1), 추간판 탈출증수술(1), 자궁근종으로 인한 자궁적출술(1)이 있었다. 합병증의 위치는 흉곽내가 10예, 흉곽외가 10예였다. 결론: 심장이식 수술후에는 흉곽 뿐만 아니라 다른 부위장기에 많은 합병증을 가져올 수 있기 때문에 장기생존율을 높이기 위해서는 다학제간의 적극적인 치료가 매우 중요하다.