• Title/Summary/Keyword: 인공고관절

Search Result 51, Processing Time 0.026 seconds

Intermediate-Term Clinical Outcomes after Total Ankle Arthroplasty for End-Stage Rheumatoid Arthritis with Modification of Perioperative Anti-Rheumatic Medication (말기 류마티스성 발목관절염에 대한 인공관절 전치환술 및 항류마티스 약물 조절 후의 중기 추시 임상 결과)

  • Cho, Byung-Ki;Ko, Ban-Suk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.3
    • /
    • pp.91-99
    • /
    • 2019
  • Purpose: This retrospective study reports the intermediate-term clinical outcomes including the practical function in daily and sports activities after total ankle arthroplasty for end-stage rheumatoid arthritis, as well as the effects of modification of perioperative anti-rheumatic medications. Materials and Methods: Twelve patients were followed for a minimum of 2 years after total ankle replacement for end-stage rheumatoid arthritis. Perioperative anti-rheumatic medications in all patients were modified based on a specific guideline. Clinical evaluations consisted of American Orthopaedic Foot and Ankle Society (AOFAS) scores, Foot and Ankle Outcome Score (FAOS), and Foot and Ankle Ability Measure (FAAM) scores. Periodic radiographic evaluation was conducted to detect changes in ankle alignment and postoperative complications. Results: Mean AOFAS, FAOS, and FAAM scores improved significantly from 37.5 to 81.2, 39.1 to 72.4, and 33.8 to 64.0 points at final follow-up, respectively (p<0.001). Functional outcomes in daily and sports activities at final follow-up were found to be 76.5 and 55.8 points for the FAOS and 70.5 and 57.5 points for the FAAM, respectively. As early postoperative complications, there was one case of local wound necrosis, one case of medial malleolar fracture, and one case of deep peroneal nerve injury. Radiological evaluation revealed two cases of asymptomatic heterotopic ossification and one case of progressive arthritis in the talonavicular joint. Reoperation was performed in only one patient (8.3%) with a medial soft tissue impingement at a mean of 35.6 months follow-up. Conclusion: Total ankle arthroplasty appears to be an effective surgical option for end-stage rheumatoid arthritis. Practical functions in daily and sports activities were significantly improved at intermediate-term follow-up. Modification of perioperative anti-rheumatic medications can be one of the solutions to reduce the postoperative complication rate.

Prognostic Factors after Arthroscopic Treatment of Infectious Knee Arthritis (감염성 슬관절염의 관절경적 치료 이후 예후 인자에 대한 분석)

  • Kang, Sang-Woo;Choi, Eui-Sung;Kim, Dong-Soo;Jung, Ho-Seung;Hong, Seok-Hyun;Go, Ban-Suk
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.30-36
    • /
    • 2019
  • Purpose: This study examined the effects of gender, age, underlying disease, duration after onset of symptoms, preoperative invasive procedures, bacterial culture of joint fluid, and stage of infection by the Gachter classification on the prognosis of patients with infectious knee arthritis who underwent arthroscopic surgery. Materials and Methods: From June 2014 to December 2016, 51 patients who underwent arthroscopic surgery for infective knee arthritis were enrolled in this study. The average follow-up period was 14.2±2.1 months (range, 12-20 months). The subjects were 27 men (52.9%) and 24 women (47.1%), with an average age of 55.1±17.6 years (range, 13-84 years). A preoperative evaluation of the joint aspiration with a count of more than 50,000 leukocytes and a polymorphonuclear leukocyte count of 95% or more was performed. All patients underwent arthroscopic surgery and postoperative continuous joint irrigation. Results: The initial mean value of the C-reactive protein decreased from 9.55±6.76 mg/dl (range, 1.51-31.06 mg/dl) to a final mean of 0.74±1.26 mg/dl (range, 0.08-6.77 mg/dl); the mean duration of C-reactive protein normalization was 27.6±18.9 days (range, 8-93 days). Among the 51 patients who received arthroscopic surgery and antibiotics, 44 patients (86.3%) with infectious knee arthritis completed treatment with improved clinical symptoms, such as fever, pain, and edema, and the C-reactive protein decreased to less than 0.5 mg/dl. Finally, 5 cases were treated with two or more arthroscopic operations, and 2 cases were converted to arthroplasty after prosthesis of antibiotic-loaded acrylic cement. Conclusion: The duration of surgery after the onset of symptoms and the stage according to the Gächter classification are important prognostic factors for predicting the successful treatment of infectious knee arthritis. On the other hand, the other factors were not statistically significant. Nevertheless, patients with bacteria cultured from the joint fluids appear to reflect the treatment period because the period of normalization of the C-reactive protein is shorter than that of the control group.

Erythrocyte Sedimentation Rate and C-reactive Protein Values in Patients with Hip Arthroplasty (인공고관절 치환술 전후의 CRP 및 ESR의 변화)

  • Kim, Se-Dong;Lee, Dong-Chul;Park, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.218-223
    • /
    • 1992
  • Serum C-reactive protein(CRP) levels and erythrocyte sedimentation rates(ESR) were measured in 46 patients treated with uncomplicated primary hip replacements, 39 total tip replacements and 7 bipolar hip replacements. In uncomplicated primary hip replacements, ESR levels were slightly elevated preoperatively and were variable postoperatively. But CRP was normal before surgery and elevated in postoperative course, but back to normal within three weeks in most cases. Early success of hip arthroplasty is indicated by normalization of CRP within three weeks, regardless of ESR. Since ESR seems to react somewhat differently from the CRP, both methods are useful in the monitoring of complications after hip arthroplasty.

  • PDF

A Study on the Interface Micromotions of Cementless Artificial Hip Replacement by Three-Dimensional FEM (무시멘트형 인공고관절 대치술후 초기의 경계면 미세운동의 3차원 FEM 연구)

  • Kim, S.K.;Chae, S.W.;Choi, H.Y.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.12
    • /
    • pp.71-74
    • /
    • 1994
  • In cementless total hip arthroplasty(THA), an initial stability of the femoral component is mandatory to achieve bony ingrowth and secondary long term fixation. Bone ingrowth depends strongly on relative micromotion and stress distributions at the interface. Primary stability of the femoral component can be obtained by minimizing the magnitude of relative micromotions at bone-prosthesis interface, Hence an accurate evaluation of interface behavior and stress/strain fields in the bone implant system may be relevant for better understanding of clinical situations and improving THA design. However, complete evaluation of load transfer in the bone remains difficult to assess experimentally, Hence, recently finite element method (FEM) was introduced in orthopaedic research field to fill the gap due to its unique capacity to evaluate stress in structure of complex shape, loading and material behavior. The authors developed the 3-dimensional numerical finite element model which is composed of totally 1179 elements off and 8 node blick. We also analyzed the micromotions at the bone-stem interface and mechanical behavior of existing bone prosthesis for a loading condition simulating the single leg stance. The result indicates that the values of relative motion for this well fit Multilock stem were $150{\mu}m$ in maximum, $82{\mu}m$ in minimum, and the largest relative motion developed in medial region of proximal femur with anterior-posterior direction. The proximal region of the bone was much larger in motion than the distal region and the stress pattern shows high stress concentration on the cortex near the tip of the stem. These findings indicates that the loading in the proximal femoral bone in the early postoperative situation can produce micromotions on the interface and clinically cementless TEA patient should not be allowed weight bearing strictly early in the postoperative period.

  • PDF

3-D Finite Element Analysis of Acetabular Reconstruction of THR (인공고관절 전치환술에 있어서 비구 재건 술에 관한 3차원 유한요소해석)

  • Ryu, J.C.;Mun, M.S.;Kim, G.S.;Yoo, M.C.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.34-38
    • /
    • 1995
  • Using a 3-D finite element method (FEM), the biomechanical characteristics of a threaded truncated acetabular component and a porous coated hemispherical acetabular component were studied. The Von-Mises stress/strain patterns in the acetabulum reconstructed with these two different types of cementless acetabular cups were investigated. The geometry and dimensions of human hemi-pelvis used in the present shape modeling for finite element analysis were scanned with a 3-D laser scanner(TDS-9000, Cyberware, USA). The scanned data was numerically handled with a shape modelling software 'Pro-Engineer'. Using 19836, 16853 tetrahedral elements, respectively, the stress and displacement field of the acetabulum reconstructed with the two different types of the acetabular components were computed. While the hemi-sphere component was found to show a relatively similar stress/strain patterns to those in the normal hip, the results with the threaded cup showed a considerably different patterns from those in the normal condition. Several regions in cancellous bone near the threads and the edge of the truncated cup was found to be overstressed, especially in the superior-lateral part of the acetabulum. It was postulated that the excessive reaming-out of subchondral bone layer when the truncated cup was used can cause the presence of these overstressed regions of cancellous bone. This theoretical prediction for the implanted acetabulum appeared to consistent with the pathological observation of proximal/medial migration of the threaded truncated acetabular prostheses in the previous publications.

  • PDF

Three-Dimensional Finite Element Analysis of Micromotion of the Straight and the Curved Femoral Stem in Cementless Hip Arthroplasty (인공고관절 직선형 대퇴 stem과 곡선형 대퇴 stem의 미세운동비교 - FEM 3차원 모델을 이용한 분석 -)

  • Kim, S.K.;Chae, S.W.;Jeong, J.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.245-248
    • /
    • 1997
  • Excessive stress on the bone-stem interface may cause local micromotion that could produce midthigh pain, interface bone resorption and prevent bony ingrowth. It is important for clinician and prosthetic designer to develop an understanding of the load transfer mechanism, its associated stress pattern and its relationships with the particular mechanical characteristics of the femoral stem designs. Finite element method (FEM) is preeminently suited to provide information in this respect. The authors developed 3-dimensional numerical finite element models implanted with the straight stem which is composed of total 1170 elements of 8 nodes and with the curved stem which is composed of total 885 elements of 8 node, and analysed the relative micromotions between the straight stem and the curved stem in immediate postoperative stage of an uncemented total hip replacement in load simulating the single leg stance. The results showed that the rotational displacement was occupied over 90% of total micromotion in both types of stem and was peak at the proximal medial portion of the stem, but markedly less distally. The curved stem was more stable especially in terms of rotational stability. It is recommended that surgeons do not allow the patient weight bearing until bony ingrowth was achieved. In the future more attention should be drawn to increase initial rotational stability of the two types of femoral stem to prevent loosening from excessive micromotion.

  • PDF

Tracheoesophageal Fistula with Subglottic Stenosis in Tracheostomy Patient -Report of 1 Case (기관절개 후 발생한 성문하 협착이 동반된 기관식도루 -수술 치험 1례-)

  • Son, Ho-Seong;Kim, Yeon-Su
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.453-456
    • /
    • 1997
  • Acquired tracheoesophageal fistula is a rare but serious condition which is usually a result of prolonged intubation or tracheostomy statc, and is difficult to treat. A fifty-seven year old woman who was in a state of prolonged intubation and tracheostomy following a traf%c accident, presented with recurrent aspirati n. A tracheoesophageal fistula was demonstrated ) cm above the carina by csophagogram. We confirmed a subglottic web and tracheoesophageal fistula by bronchoscopic examination. Fistulectomy was performed with collor incision and partial sternotomy. The esophagus was repaired by two-layer interrupted suture using 4-0 Vicr)1, and the trachea was repaired by single layer suture using a 4-0 PDS. The sternohyoid muscle was interposed between the trachea and the esophagus. A T-tube was inserted through the previous tracheostomy site for easy tracheal suction and maintenance of the tun:on. The T-tube was removed on the 14th postoperative day, and the patient recovered well without any complications.

  • PDF

Comparative Study on Wear Resistance and Hardness of Several Artificial Resin Teeth (수종의 인공 레진 치아의 마모저항성과 경도에 관한 비교 연구)

  • Choi, Yu-Sung;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.129-146
    • /
    • 2008
  • The aim of this study was to compare and analyze wear resistance of acrylic resin tooth in denture opposing to different types of restoration materials. Also, it aimed to compare and analyze the hardness of three various types of resin artificial teeth when using five different types of denture detergents. In this study three types of artificial teeth were used. As ordinary acrylic resin tooth $Trubyte^{(R)}Biotone^{(R)}$ (Dentsply, U.S.A.) was used, and as high hardness resin tooth Endura $Posterio^{(R)}$ (Shofu, Japan) and Physio $Duracross^{(R)}$ (Nissin, Japan) were used. To compare wear resistance, gold alloy, dental porcelain, and composite resin were used as opposing restorations. In addition, with three types of resin tooth stated above, five types of denture detergents, which are $Yuhanrox^{(R)}$ (Yuhanclorox, Korea), $Polident^{(R)}$ (Yuhan Co., Korea), $Cidex^{(R)}OPA$ (Johnson & Johnson Medical Co., Korea), $Hexamedin^{(R)}$ (Bukwang Pharm Co., Korea) and Daihan sterile $water^{(R)}$ (Daihan Pharm Co., Korea) were used to compare and analyze the effects denture detergents have on the surface hardness. The results of this study were as follow : 1. When composite resin and dental porcelain were used as the opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in ascending order showed decrease of cusp height with significant difference (p<0.05). 2. When gold alloy was used as opposing restoration, there was decrease in the cusp height in order of $Trubyte^{(R)}Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant decrease in high cusp height as compared to two other types of artificial tooth (p<0.05). 3. When composite resin, gold alloy and dental porcelain were used as opposing restorations, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order decreased greatly in weight and these three materials showed significant difference (p<0.05). 4. Comparing the experiment values, decrease in strength had significant difference in all resin artificial teeth before and after the denture detergents were used (p<0.05). 5. When resin artificial teeth were subsided in $Yuhanrox^{(R)}$, $Cidex^{(R)}OPA$, and $Hexamedin^{(R)}$, $Trubyte^{(R)}$ $Biotone^{(R)}$, Endura $Posterio^{(R)}$, Physio $Duracross^{(R)}$ in order showed decrease in hardness, and $Trubyte^{(R)}$ $Biotone^{(R)}$ especially showed significant high decrease hardness as to other two types of artificial teeth (p<0.05). Therefore, Physio $Duracross^{(R)}$ seems to have superior wear resistance, and together with Endura $Posterio^{(R)}$, it presents excellent hardness as compared to $Trubyte^{(R)}$ $Biotone^{(R)}$. However, since this study is fragmentary, it should be given careful consideration and more study need to be done before making a definitive conclusion.

A Biomechanical Study on a New Surgical Procedure for the Treatment of Intertrochanteric Fractures in relation to Osteoporosis of Varying Degrees (대퇴골 전자간 골절의 새로운 수술기법에 관한 생체역학적 분석)

  • 김봉주;이성재;권순용;탁계래;이권용
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.401-410
    • /
    • 2003
  • This study investigates the biomechanical efficacies of various cement augmentation techniques with or without pressurization for varying degrees of osteoporotic femur. For this study, a biomechanical analysis using a finite element method (FEM) was undertaken to evaluate surgical procedures, Simulated models include the non-cemented(i.e., hip screw only, Type I), the cement-augmented(Type II), and the cemented augmented with pressurization(Type III) models. To simulate the fracture plane and other interfacial regions, 3-D contact elements were used with appropriate friction coefficients. Material properties of the cancellous bone were varied to accommodate varying degrees of osteoporosis(Singh indices, II∼V). For each model. the following items were analyzed to investigate the effect surgical procedures in relation to osteoporosis of varying degrees : (a) von Mises stress distribution within the femoral head in terms of volumetric percentages. (b) Peak von Mises stress(PVMS) within the femoral head and the surgical constructs. (c) Maximum von Mises strain(MVMS) within the femoral head, (d) micromotions at the fracture plane and at the interfacial region between surgical construct and surrounding bone. Type III showed the lowest PVMS and MVMS at the cancellous bone near the bone-construct interface regardless of bone densities. an indication of its least likelihood of construct loosening due to failure of the host bone. Particularly, its efficacy was more prominent when the bone density level was low. Micromotions at the interfacial surgical construct was lowest in Type III. followed by Type I and Type II. They were about 15-20% of other types. which suggested that pressurization was most effective in limiting the interfacial motion. Our results demonstrated the cement augmentation with hip screw could be more effective when used with pressurization technique for the treatment of intertrochanteric fractures. For patients with low bone density. its effectiveness can be more pronounced in limiting construct loosening and promoting bone union.

Hip Range of Motion Estimation using CT-derived 3D Models (CT기반 3차원 모델을 이용한 고관절 운동범위 예측)

  • Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.115-122
    • /
    • 2018
  • The success of the total hip arthroplasty is revealed as initial stability, range of motion, and long term pain, etc. Depending upon choice of implantation options such as femoral neck offset, diameter of the femoral head, the lateral opening tilt. Especially the impingement between femoral head component and acetabular cup limits the range of motion of the hip. In this sense, estimation or evaluation of the range of motion before and after the total hip arthroplasty is important. This study provides the details of a computer simulation technique for the hip range of motion of intact hip as well as arthroplasty. The suggested method defines the hip rotation center and rotation axes for flexion and abduction, respectively. The simulation uses CT-based reconstructed 3D models and an STL treating software. The abduction angle of the hip is defined as the superolateral rotation angle from sagittal plane. The flexion angle of the hip is defined as the superoanterior angle from the coronal plane. The maximum abduction angle is found as the maximum rotation angle by which the femoral head can rotate superolaterally about the anterior-posterior axis without impingement. The maximum flexion angle is found as the maximum rotation angle by which the femoral head can rotate superoanteriorly about the medial-lateral axis without impingement. Compared to the normal hip, the total hip replacement hip showed decreased abduction by 60 degrees and decreased flexion by 4 degrees. This measured value implies that the proposed measurement technique can make surgeons find a modification of increase in the femoral neck offset or femoral head, to secure larger range of motion.