전력공급확률을 이용한 분산형 전원을 고려한 배전계통 신뢰도 평가에 관한 연구 (A Study on the Reliability Evaluation of Power Distribution System with Distributed Generations using Power Supplied Probability)

  • 이희태;문종필;김재철
    • 전기학회논문지
    • /
    • 제59권12호
    • /
    • pp.2119-2124
    • /
    • 2010
  • Reliability evaluation of power distribution system is the evaluation for all customers supplied from one power source as main transformer located in substation. However, power sources include not only the main transformer but distributed generations. Typical reliability evaluation has focused on configuration of power system with one source including failure rates of equipment. In this paper, we focus on not only configuration but power sources as distributed generations. New reliability evaluation method using power supplied probability (PSP) is proposed. The proposed evaluation method are proved through case studies.

배전자동화 계통의 루프 운전시 보호협조에 관한 연구 (A Study on the Protective Coordination of Distribution Automation System under Loop Operation)

  • 이희태;문종필;김재철
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1281-1286
    • /
    • 2009
  • As a general radial configuration of power distribution system, the various researches have being studied to change a radial configuration to network one such as smart, intelligent and micro grid for loop operation. If a radial configuration changes to network, protective coordination comes to the biggest problem. When a typical protective algorithm is applied to loop distribution system protection, the interrupted section is expanded, therefore, reliability grows worse. This paper presents the new protective method being able to apply to loop distribution system with Distribution Automation System (DAS) which separate the minimal faulted section. Through contingency analysis of the sustained and momentary fault, we analyzed the influence for radial configuration and loop configuration using interrupted area and proved the effectiveness of proposed method.

단일루프 배전계통과 방사상 배전계통의 순간정전을 고려한 신뢰도 비교 연구 (A Comparative Study for Reliability of Single and Radial Power Distribution System considering Momentary Interruption)

  • 이희태;김재철
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1270-1275
    • /
    • 2009
  • The structure of a power distribution system will change in a loop configuration such as in the case of a smart grid. If power distribution system changes radial to loop form, the structure may have to be changed significantly. Therefore, we analyzed the reliability indices and calculated a CIC(Customer Interruption Cost) for the loop power distribution system. The power distribution system reliability depends on the protection scheme. This study is applied to the current protection scheme method and is compared with each model. When the CIC was evaluated, most studies performed calculations only for sustained interruptions. However, in actuality, momentary interruption frequencies occurred more than sustain interruptions. Thus, it is occurred the CIC additively. Therefore, we evaluated a CIC including momentary interruption, for each model, and then compared with MAIFI(Momentary Average Interruption Frequency Index)

풍력발전시스템의 출력제어를 위한 에너지저장장치의 Fuzzy PI제어기 설계에 관한 연구 (Wind turbine output control using Fuzzy PI controller of Energy storage system)

  • 이희태;구본길;이상훈;박준호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.402-403
    • /
    • 2011
  • This paper presents an active and reactive power compensator for the wind power system with multi-polar synchronous generator. The proposed compensator is composed of a charge/discharge PWM converter and battery. The output power of a wind power system changes irregularly according to the variation of wind speed. The developed system is able to continuously compensate the active and reactive power. The operational feasibility of the proposed model was verified by simulations with PSCAD/EMTDC.

  • PDF

차단기와 리클로져의 통신을 이용한 루프 배전계통의 보호협조 적용시 신뢰도 비교에 관한 연구 (A Study on the Comparison of Reliability for Protective Coordination of Loop Power Distributions using Communication of Circuit Breaker and Recloser)

  • 이희태;문종필
    • 전기학회논문지P
    • /
    • 제60권3호
    • /
    • pp.133-137
    • /
    • 2011
  • The purpose of smart grid is the low $CO_2$ through expansion of renewable energy. To achieve the purpose of smart grid, typical radial power distribution system will be changed to loop power distribution system. The loop power distribution system have many advantages such as low power loss, low voltage drop, and increase of connection of renewable energy. In this paper, the algorithm for minimization of interrupted section of power distribution system is proposed through communication between circuit breaker and recloser in loop power distribution system. The proposed algorithm is proved through case studies about reliability evaluation

보호계전기의 오동작에 의한 배전계통 신뢰도에 대한 연구 (A Study of the Reliability of Distribution System for Malfunction of Protective Relay)

  • 신정진;이희태;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.205_206
    • /
    • 2009
  • Protection system is important part in distribution system. Protection system in power systems can fail either by not responding when they should(failure to operate) or by operating when they should not(false tripping). Customers has dissatisfied that due to the failure of protection system. The reliability of distribution system also has influenced. However, the failure of protection system can reduced by the maintenance. This paper has focused on malfunction of protection system. The approach is based on Markov models.

  • PDF

수지상 배전계통을 단일루프로 구조 변경시 신뢰도 비교 (The Comparison of Reliability for Change Single Loop Configuration in Radial Power Distribution System)

  • 이희태;김재철;김주용
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1472-1478
    • /
    • 2009
  • The domestic power distribution system is operating in an open loop mode; however, it already has a loop structure. Power distribution systems must be changed for bi-directions power supply for smart networks due to a changing of paradigm in electric power industry. The simplest bi-directions distribution networks can make it closing of normally open switch. However, bi-directions power supply is very difficulty to be operated and there are many parts which it must study. This paper presented various models that are able to change a radial system for loop structures. Further, we compared the reliability index for each model by evaluating the amount of improvement reliability required in radial power distribution system. In addition, we calculated CIC(Customer Interruption Cost) for each model by comparing and analyzing.

전력량계 무정전 교체장치 개발에 관한 연구 (Development of Watt-Hour Meter Exchange Equipment without Outage)

  • 정태훈;조성민;신희상;이희태;김재철
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.99-103
    • /
    • 2009
  • 본 논문에서는 부하설비의 정전 시간을 최소화하기 위한 전력량계 무정전 교체 장치를 고안하여 개발하였다. 개발된 교체 장치는 전력량계 교체 시 정전을 피하기 위해 시행되고 있는 단순 우회회로 결선방법, UPS 사용법 등, 다른 방법들에 비해 간편하여 효율성을 증대하였다. 그리고 교체 작업동안 안전성을 확보하기 위하여 보호 요소들을 구성함으로써 신뢰성 또한 증대하였다. 본 장치의 적용으로 고객에게 정전 시간을 단축하여 신뢰성 있는 전력공급을 보장할 수 있게 되었다.

배전기기 고장률 추출에 관한 연구 (A Study on Failure Rate Extraction of Power Distribution System Equipment)

  • 문종필;김재철;이희태;추철민;안재민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.366-368
    • /
    • 2007
  • In this paper, the Time-varying Failure Rate (TFR) of power distribution system equipment is extracted from the recorded failure data of Korea Electric Power Corporation (KEPCO). For TFR extraction, it is used that the fault data accumulated by KEPCO during 10 years. The TFR is approximated to bathtub curve using the exponential (random failure) and Weibull (aging failure) distribution function. In addition, Kaplan-Meier estimation is applied to TFR extraction because of incomplete failure data of KEPCO. Finally, Probability plot and regression analysis is applied. It is presented that the extracted TFR is more effective and useful than Mean Failure Rate (MFR) through the comparison between TFR and MFR.

  • PDF

전력품질로 인한 아파트 수용가 승강기의 전기적 설비 영향에 관한 연구 (A Study on electrical equipment effect of apartment customer elevator by power quality)

  • 이희태;김재철;강장규;김기현;설규환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.304-305
    • /
    • 2006
  • Now there is utilization of elevator increasing continuously, it is one of electrical facilities taking a serious view safety. However, elevator comfortable ride is researched generally Recently aging condition, equipment life, malfunction, other applicancies of power electronics and equipment disturbance effect on power quality and prevention measures are much researches in advanced nation. but awareness is lacking real condition up to now in domestic. Voltage sag, swell, harmonics, surge etc of elevator system is important problem about human safety. and there are many quality compensation to solve these problem of elevator. So to evaluate these problem, in this paper, displayed result through computer simulation for converter of problem, and inverter part by power quality problem in power distribution system.

  • PDF