• Title/Summary/Keyword: 이차방사선

Search Result 125, Processing Time 0.025 seconds

Comparison of Clinical Results and Second-Look Arthroscopy after Anterior Cruciate Ligament Reconstruction using Hamstring Tendon Autograft, Mixed graft and Tibialis Tendon Allograft (자가슬괵건, 혼합건 및 동종 경골건을 이용하여 실시한 전방십자인대 재건술후 임상결과 및 이차관절경 검사 비교)

  • Cho, Jin-Ho
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.18-26
    • /
    • 2011
  • Purpose: This study is to compare the clinical results of ACL reconstruction between three groups using hamstring tendon autograft, mixed and tibialis tendon allograft. Materials and Methods: Between August 2003 and August 2008, we analyzed 169 cases of ACL reconstruction, 66 cases used hamstring tendon autograft, 42 cases used mixed graft and 61 cases used tibialis tendon allograft, with a minimum follow-up of 12 months. For the clinical evaluation, we evaluated the Lysholm score, Telos stress test device and IKDC score. Results: The average side to side difference in Telos stress test decreased from $7.5{\pm}1.0$ mm to $1.6{\pm}1.0$ mm in autograft group, from $7.6{\pm}1.1$ mm to $1.4{\pm}1.1$ mm in mixed graft group and from $7.4{\pm}1.3$ mm to $2.5{\pm}1.3$ mm in allograft group. The average Lysholm knee score improved from 58.6 to 92.3 in autograft group, from 60.6 to 92.6 in mixed graft group and from 55.3 to 91.5 in allograft group. There was no significant difference between three groups in clinical results. At second look arthroscopy, tension of ligament and synovial coverage were good result in autograft and mixed graft than allograft group. Conclusion: All hamstring tendon autograft, mixed graft and tibialis tendon allograft groups showed satisfactory clinical results, with no significant difference in outcomes between the groups. Both hamstring tendon autograft and mixed graft showed good synovial coverage in second look arthroscopy. So mixed graft will be considered as good alternative in case of shorter or thin harvested hamstring tendon.

  • PDF

A case of pulmonary vascular air embolism in a very-low-birth-weight infant with massive hydrops (초극소 미숙아에서 발생한 중증 태아 수종을 동반한 폐혈관 공기 색전증 1례)

  • Kim, Myo Jing;Yu, Hee Joon;Lee, Cha Gon;Park, Soo Kyoung;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.12
    • /
    • pp.1392-1395
    • /
    • 2009
  • Pulmonary vascular air embolism is a rare and, universally, almost a fatal complication of positive pressure ventilation in newborn infants. Here, we report a case of this unusual complication in a very-low-birth-weight infant who showed the clinical and radiological features of this complication along with pulmonary hypoplasia and massive hydrops. The possible pathogenesis has been discussed and a brief review of related literature has been presented.

The Effect of Gamma-Irradiation on Aqueous Solutions of Triglycine 3. Mechanism for Gamma-ray Induced Degradation Products (Triglycine 수용액에 미치는 감마선의 영향 3. 감마선에 의한 분해산물에 관하여)

  • ;LEONE, Charles A
    • The Korean Journal of Zoology
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 1964
  • Carbonyl compounds, glycine, ammonia, carbon dioxide and hydrogen have been identified in gamma-irradiated oxygenated aqueous solutions of triglycine. The reactions occurring in this system are postulated only by representing the initial process and the final products. The triglycine molecule undergoes a reaction to form an intermediate giving rise to carbonyl compounds and acid amides. These compounds are decomposed to acetamide, glycine, glyoxylic acid, formic acid, oxalic acid, ammonia, and carbon dioxide by free radical attack in the primary and/or secondary reactions. It is also possible that the unrecognized reactions may give rise to products formed by radical-radical combinations. Satisfactory material balance for all the products have to wait until the completion of a study now in progress.ogress.

  • PDF

Arthroscopic Assisted Reduction and Internal Fixation of Lateral Femoral Epiphyseal Injury in Old Adolescent Soccer Player - Report of 1 Case - (청소년기 축구선수에서 원위 대퇴외과 성장판 손상의 관절경하 정복 및 내고정 - 1례 보고-)

  • Lee, Yong-Seuk;Jung, Jae-Kyoung;Kong, Chae-Kwan;Shin, Yoon-Chang
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.66-69
    • /
    • 2007
  • Sports-related knee injuries frequently occur in adolescent period and fractures are more common than ligamentous Injuries in this age group because of physiologic characteristics. We operated an adolescent soccer player with lateral femoral epiphyseal injury using arthroscopic assisted reduction and infernal fixation. In $2^{nd}$ look arthroscopy and metal removal at postoperative 2 years, articular cartilage was healed with good congruity and lower extremity entire long film showed normal axial alignment without residual deformity.

  • PDF

A Case of Tracheal Cancer Arising 3 Years after Radiation Therapy for Laryngeal Cancer (후두암에 대한 방사선 치료 3년 후 기관암이 발생한 환자 1례)

  • Yum, Gunhwee;Oh, Kyung Ho;Choi, Jung Woo;Kwon, Soon Young
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.29 no.2
    • /
    • pp.110-113
    • /
    • 2018
  • Tracheal cancer is rare and accounts for approximately 0.03% of all malignancies. Because of atypical symptoms, tracheal cancer can be misdiagnosed as obstructive lung disease, or tumors of thyroid or lung. Among patients of previous head and neck cancer, other primary cancer may accompany which called "econd primary cancer". We report a case of patient with tracheal cancer 3 years after definite radiation therapy of laryngeal cancer with a review of related literatures.

Outcomes after Radiotherapy in Inoperable Patients with Squamous Cell Lung Cancer (수술이 불가능한 편평상피성 폐암의 방사선치료 성적)

  • Ahn Sung-Ja;Chung Woong-Ki;Nah Byung-Sik;Nam Tack-Keun;Kim Young-Chul;Park Kyung-Ok
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.216-223
    • /
    • 2001
  • Purpose : We evaluated retrospectively the outcomes of inoperable squamous cell lung cancer patients treated with radiotherapy to find out prognostic factors affecting survival. Materials and methods : Four hundred and eleven patients diagnosed as squamous cell lung cancer between November 1988 and December 1997 were the basis of this analyses. The planned dose to the gross tumor volume was ranged from 30 to 70.2 Gy. Chemotherapy was combined in 72 patients $(17.5\%)$ with the variable schedule and drug combination regimens. Follow-up period ranged from 1 to 113 months with the median of 8 months and survival status was identified in 381 patients $(92.7\%)$. Overall survival rate was calculated using the Kaplan-Meier method. Results : Age ranged from 23 years to 83 years with the median 63 years. The male to female ratio was about 16:1. For all 411 patients, the median overall survival was 8 months and the 1-year survival rate (YSR), 2-YSR, and 5-YSR were $35.6\%,\;12.6\%,\;and\;3.7\%$, respectively. The median and 5-YSR were 29 months and $33.3\%$ for Stage IA, 13 months and $6.3\%$ for Stage IIIA, and 9 months and $3.4\%$ for Stage IIIB, respectively(p=0.00). The median survival by treatment aim was 11 months in radical intent group and 5 months in palliative, respectively (p=0.00). Of 344 patients treated with radical intent, median survival of patients (N=247) who received planned radiotherapy completely was 12 months while that of patients (N=97) who did not was 5 months (p=0.0006). In the analyses of the various prognostic factors affecting to the survival outcomes in 247 patients who completed the planned radiotherapy, tumor location, supraclavicular LAP, SVC syndrome, pleural effusion, total lung atelectasis and hoarseness were statistically significant prognostic factors both in the univariate and multivariate analyses while the addition of chemotherapy was statistically significant only in multivariate analyses. The acute radiation esophagitis requiring analgesics was appeared in 49 patients $(11.9\%)$ and severe radiation esophagitis requiring hospitalization was shown in 2 patients $(0.5\%)$. The radiation pneumonitis requiring steroid medication was shown in 62 patients $(15.1\%)$ and severe pneumonitis requiring hospitalization was occurred in 2 patients $(0.5\%)$. During follow-up, 114 patients $(27.7\%)$ had progression of local disease with 10 months of median time to recur (range : $1\~87\;months$) and 49 patients $(11.9\%)$ had distant failure with 7 months of median value (range : $1\~52\;months$). Second malignancy before or after the diagnosis of lung cancer was appeared in 11 patients Conclusion : The conventional radiotherapy in the patients with locally advanced squamous cell lung cancer has given small survival advantage over supportive care and it is very important to select the patient group who can obtain the maximal benefit and to select the radiotherapy technique that would not compromise the life quality in these patients.

  • PDF

Development of a Korean Adult Female Voxel Phantom, VKH-Woman, Based on Serially Sectioned Color Slice Images (고해상도 연속절단면 컬러해부영상을 이용한 한국인 성인여성 복셀팬텀 VKH-Woman 개발)

  • Jeong, Jong Hwi;Yeom, Yoen Soo;Han, Min Cheol;Kim, Chan Hyeong;Ham, Bo Kyoung;Hwang, Sung Bae;Kim, Seong Hoon;Lee, Dong-Myung
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.199-208
    • /
    • 2012
  • The computational human phantom including major radiation sensitive organs at risk (OARs) can be used in the field of radiotherapy, such as the variation of secondary cancer risks caused by the radiation therapy and the effective dose evaluation in diagnostic radiology. The present study developed a Korean adult female voxel phantom, VKH-Woman, based on serially sectioned color slice images of Korean female cadaver. The height and weight of the developed female voxel phantom are 160 cm and 52.72 kg, respectively that are virtually close to those of reference Korean female (161 cm and 54 kg). The female phantom consists of a total of 39 organs, including 27 organs recommended in the ICRP 103 publication for the effective dose calculations. The female phantom composes of $261{\times}109{\times}825$ voxels (=23,470,425 voxels) and the voxel resolution is $1.976{\times}1.976{\times}2.0619mm^3$ in the x, y, and z directions. The VHK-Woman is provided as both ASCII and Binary data formats to be conveniently implemented in Monte Carlo codes.

Status of Interchange of Medical Imaging in Korea: A Questionnaire Survey of Physicians (영상정보교류 실태 파악을 위한 의사 설문조사)

  • Choi, Moon Hyung;Jung, Seung Eun;Kim, Sungjun;Shin, Na-Young;Yong, Hwan Seok;Woo, Hyunsik;Jeong, Woo Kyoung;Jin, Kwang Nam;Choi, SeonHyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.247-253
    • /
    • 2018
  • The purpose of this study was to summarize the results of a survey for physicians with specialties other than radiology about imaging studies of patients referred from other institutions. The survey was promoted through individual contacts or social network service and physicians who voluntarily responded to the survey were the subjects of the study. The questionnaire consisted of 11 questions about basic information and referrals about medical imaging. A total of 160 physicians from 30 specialties participated in the survey and 95.6% of the respondents worked in tertiary care center or general hospital. Patients were frequently referred with outside medical images. The most frequently referred imaging modalities were computed tomography and magnetic resonance imaging. However, radiological reports from outside institutions were rarely referred. Most physicians thought that reinterpretation for outside imaging is necessary to acquire a secondary opinion. In conclusion, considering that outside radiological reports are frequently missing and there are high demands on reinterpretation for outside imaging, guidelines for referral of radiological reports with medical imaging, basic elements of radiological reports, and reinterpretation need to be developed.

Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron (MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가)

  • Eom, Keun-Yong;Park, Hye-Jin;Huh, Soon-Nyung;Ye, Sung-Joon;Lee, Dong-Han;Park, Suk-Won;Wu, Hong-Gyun
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.280-284
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate biological characteristics of neutron beam generated by MC50 cyclotron located in the Korea Institute of Radiological and Medical Sciences (KIRAMS). $\underline{Materials\;and\;Methods}$: The neutron beams generated with 15 mm Beryllium target hit by 35 MeV proton beam was used and dosimetry data was measured before in-vitro study. We irradiated 0, 1, 2, 3, 4 and 5 Gy of neutron beam to EMT-6 cell line and surviving fraction (SF) was measured. The SF curve was also examined at the same dose when applying lead shielding to avoid gamma ray component. In the X-ray experiment, SF curve was obtained after irradiation of 0, 2, 5, 10, and 15 Gy. $\underline{Results}$: The neutron beams have 84% of neutron and 16% of gamma component at the depth of 2 cm with the field size of $26{\times}26\;cm^2$, beam current $20\;{\mu}A$, and dose rate of 9.25 cGy/min. The SF curve from X-ray, when fitted to linear-quadratic (LQ) model, had 0.611 as ${\alpha}/{\beta}$ ratio (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$, respectively). The SF curve from neutron beam had shoulders at low dose area and fitted well to LQ model with the value of $R^2$ exceeding 0.99 in all experiments. The mean value of alpha and beta were -0.315 (range, $-0.254{\sim}-0.360$) and 0.247 ($0.220{\sim}0.262$), respectively. The addition of lead shielding resulted in no straightening of SF curve and shoulders in low dose area still existed. The RBE of neutron beam was in range of $2.07{\sim}2.19$ with SF=0.1 and $2.21{\sim}2.35$ with SF=0.01, respectively. $\underline{Conclusion}$: The neutron beam from MC50 cyclotron has significant amount of gamma component and this may have contributed to form the shoulder of survival curve. The RBE of neutron beam generated by MC50 was about 2.2.

A STUDY ON THE CORRELATIONSHIP OF SUBMENTOVERTEX VIEW AND LATERAL CEPHALOGRAM MEASUREMENTS (이하두정방사선사진과 측모두부방사선사진상에서의 계측치 상호연관성에 관한연구)

  • Cho, Jae-Hyung;Ryu, Young-Kyu
    • The korean journal of orthodontics
    • /
    • v.26 no.4
    • /
    • pp.414-420
    • /
    • 1996
  • Cephalometric measureements have disadvantage of representing cranio-facial structures in two dimension only and therefore they pose limitations in describing three-dimentional structures of cranio-facial region. More interests have been put on the correlation between the two planes. This study evaluated correlations between facial type score, which allows effects on malocclusion, growth change prediction and establishment of treatment method and prognosis, and measurements from submentovertex view. Cephalometric view and submentovertex view were taken of skeletal Class I adults with optimal profile and correlations between them have been observed. Following results were obtained: 1. To learn about factors that influence average condylar angulation, FACE, INT-CO-ANG, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO were used as variables and underwent multiple regression analysis. As a result, the following equation was obtained : CON-AVE=.l73(FACE)-.322(INT-CO-ANG)+36.34(GON-RATIO) +.420(MN-CORPUS) (($R^2=.85451$) 2. The following equation was obtained concerning facial type score. FACE= .050(CON-ANG)+.023(INT-CO-ANG)-.075(MN-CORPUS)($R^2=.31547$) 3. Among the submentovertex measurements, MN-CORPUS, CON-RATIO, GON-RATIO, MN-RATIO showed close correlations. (P<0.05) 4. Average condylar angualtions were $23.37^{\circ}$ on the right and $20.71^{\circ}$ on left. There was a difference between the two. FACE : facial type soore. CON-ANG: mean value of condylar angulation. CON-AVE: mean value of Rt. Lt condylar angulation. INT-CO-ANG : angle between Rt. Lt condylar axis. MN-CORPUS : angle formed between RT. Lt gonion & pogonion. CON-RATIO: lntercondylar distance/mandibular body length. GON-RATIO : intergonion distanoe/mandibular body length. MN-RATIO: lntermylohyoid distance/mandibular body length. MX-RATIO: intermaxillary tuberosity distance/ANS-PNS distance.

  • PDF