Search Result 525, Processing Time 0.031 seconds

이중관 배관공법

  • Gang, Byeong-Cheol
    • 월간 기계설비
    • /
    • no.4 s.189
    • /
    • pp.31-38
    • /
    • 2006
  • 시공을 잘 해놓고도 하자가 발생하면 업체는 매우 난감해진다. 하자는 기업의 신뢰성을 실추시킴은 물론 막대한 보수비용도 들어서 업체에서는 가급적이면 하자를 줄일 수 있는 공법개발에 심혈을 기울이고 있다. 본지는 하자발생률을 저하시키는 이중관 배관공법을 활발하게 시공하고 있는 (주)한은 E&C의 이중관 배관공법을 이번 호에 게재하고, 다음 호에는 (주)세방TEC의 이중관 배관공법을 게재할 계획이다.

  • PDF

Remote Field Energy Flow Path at Nonmagnetic Coaxial Tubes (비자성체 이중관의 원격장 에너지 전달 경로)

  • Yi, Jae-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.526-531
    • /
    • 2001
  • The flow of remote field eddy current energy is studied at nonmagnetic coaxial tubes by using both experiments and finite element calculations based on commercial software package. The results showed that remote field eddy current energy at coaxial tubes flow along over the outer surface of external tube, not through the gap between internal and external tubes. This means that the through wall transmission characteristic of remote field eddy current testing (RFECT) is still valid at tube in tube configurations and the RFECT could be potential nondestructive technique for crack detection, spacer location and gap sizing at the coaxial CANDU fuel channel tubes.

  • PDF

Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants (장기간 사용한 이중관 의치의 실패원인 및 자연치와 임플란트를 이용한 이중관 의치 수복증례)

  • Seo, Jeong-Gyo;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.384-390
    • /
    • 2018
  • Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be used for improving retention and support for denture with strategically placed implants on edentulous ridge. In this case, an 55-year-old female patient had chronic periodontitis with few remaining teeth on maxilla and fixed partial prosthodontics on mandible. Treatment of hybrid telescopic double crown with friction pin lasted 9.5 years only with natural teeth. After 9.5 years, additional implants was installed due to fracture of cast-posted abutment teeth. After implantation, tooth and implant combined double crown had fabricated. Through re-treatment, no complications of new denture has been found during 2 years follow up. This case presents fair prognosis of tooth and implant combined double crown denture in periodontally unfavorable condition.

Literature review and case report of prosthetic rehabilitation with telescopic denture (이중관 의치에 관한 문헌 고찰 및 증례 보고)

  • Sung, Han-Gyul;Jo, Eun-Hye;Ko, Kyung-Ho;Huh, Yoon-Hyuk;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.4
    • /
    • pp.308-316
    • /
    • 2018
  • Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due to secondary fixation between abutments and have been reported a higher success rates than conventional removable partial denture (RPD). However, there are disadvantages such as complex laboratory procedures, long treatment periods and high costs, and high incidence of complications. This clinical report describes two cases, a 4-point supported telescopic denture using telescopic crown and a 2-point supported telescopic denture using conical crown with functionally satisfactory results. Frequent complications of telescopic denture, which are reported in various literature were reviewed. Clinical and laboratory procedures were performed in consideration of complications that reported.

A Study on Blasting Vibration Control Criteria for Pre-insulated Pipe through the Numerical Analysis (수치해석을 이용한 이중보온관 발파진동 관리기준에 관한 연구)

  • Choi, Bong-Hyuck;Cho, Jin-Woo;Kim, Jin-Man;Yoo, Han-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.4
    • /
    • pp.1471-1478
    • /
    • 2013
  • In this paper, numerical analysis with varying distance and burial depth was performed to recommend the blasting vibration control standard for pre-insulated pipes. The blasting load model applied in the numerical analysis was verified to the comparison with the results of the field tests. It was determined from the results of the numerical analysis that the effective stress either exceeds or approaches the allowable stress of the inner steel pipe for vibration velocity greater than 4.0cm/sec while stability is obtained for vibration velocity below 4.0cm/sec. Therefore, it was determined that the blasting vibration control criteria for pre-insulated pipes must not exceed 4.0cm/sec.

A study on the heat recovery Characteristics of double tube type heat recovery ventilation system by double pipe material (이중관 재질에 따른 이중관형 열회수 환기장치의 열회수 특성 연구)

  • Kim, Eun-Young;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.21-26
    • /
    • 2017
  • In this study, performance tests were conducted to investigate the applicability of a double-tube heat recovery ventilation system. Paper, aluminum, polymer, were investigated as materials for the inner tube using the same exhaust-air volume. In all cases, the temperature exchange efficiency of the aluminum tube was the highest, while the paper tube showed similar results to those of the polymer tube. This probably resulted from the differences in thermal conductivity and thicknesses of the materials. The humidity exchange efficiency was the highest for the paper tubes in all cases, while the aluminum tubes and polymer tubes showed similar results. The total heat exchange efficiency, which includes the values of humidity exchange and temperature exchange, was highest in the case of the paper tube, and the aluminum tube and the polymer tube showed similar results. In the case of the paper tube, sensible heat and latent heat exchange occur at the same time, and the coefficient of energy of the aluminum tube and polymer tube are large values, when to be compared with only applicably sensible heat exchange coefficient of the aluminum tube and the polymer tube of total heat exchange efficiency value. The results of this study could be applied to the design of a ventilation system.

A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth (고립된 소수 잔존치 환자에서 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관 국소의치의 임상증례)

  • Sohn, Sang-Hyuk;Cho, Jin-Hyun;Cho, Sung-Am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.1
    • /
    • pp.80-86
    • /
    • 2016
  • A few authors have reported good clinical results using double crown removable partial denture (RPD) with a few remaining teeth. Hybrid telescopic double crown is a good indication for a patient with poor periodontal condition and/or few remaining teeth after extraction, especially located in cross-arch position. In this case, there was a poor periodontal condition with teeth mobility. Several teeth with poor prognosis were extracted. Remaining anterior teeth was restored with fixed prostheses and edentulism was restored with Kennedy class I removable partial denture in maxilla. In mandible, it was hard to restore with clasp removable partial prostheses because of bilaterally isolated remaining teeth so that hybrid double crown removable partial denture with friction pin was suitable for this case. The objective of this report is to discuss the characteristics and the utility of hybrid double crown prostheses using a few remaining teeth in mandible.

Treatment of the cleft lip and palate patient with few remaining posterior teeth using hybrid telescopic crown denture (치주질환에 이환된 소수 잔존치를 가지는 구순구개열 환자에서의 상악 혼성 이중관 의치를 이용한 수복증례)

  • Park, Jin-Wook;Cho, Jin-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.4
    • /
    • pp.284-290
    • /
    • 2017
  • For individuals with cleft lip and palate, the removable partial dentures (RPDs) have been an important treatment option. Some modifications from conventional prosthetic treatment may be necessary to achieve satisfactory functional and esthetic results in cleft patients. In case of cleft palate patient with periodontally compromised and only posterior few remaining teeth, removable partial prosthesis connected to telescopic crown can be the alternative treatment option. When connected to the RPD, telescopic crowns increase the prosthetic stability and retention, optimize favorable force transmission to the long dental axis, and improve esthetics. And the cross arch stabilization of double crown denture helps to stabilize both divided maxillary ridges in CLP patient. This case present one adult CLP patient using an RPD connected with hybrid telescopic crowns with friction pins to improve not only retention and stability but also aesthetics.

A Study on Alternative Backfill Material for Pre-insulated Pipe through the Field Tests (현장시험을 통한 이중보온관 되메움 대체재료에 관한 연구)

  • Choi, Bong-Hyuck;Kim, Jin-Man;Yoo, Han-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1C
    • /
    • pp.1-6
    • /
    • 2012
  • In this study, field tests were performed to evaluate the stability of pre-insulated pipe during the compaction operation and to recommend an alternative backfill material. Three types of natural sand (fine-grained and medium-grained, coarse-grained sand), crushed sand and two types of gravel (10 mm, 20 mm) were used as backfill material in the field tests. Field tests were performed to determine the behavior (earth-pressure and deformation, installation damage) of the pre-insulated pipe due to variation of different types of backfill material. Based on the evaluation and comparison of field test results, it was determined that crushed sand is the most suitable back-fill material that can be used as an alternative for medium grained sand for pre-insulated pipes with respect to the engineering behavior and material supply.

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.