• 제목/요약/키워드: 이중에너지

Search Result 998, Processing Time 0.019 seconds

Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD (뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가)

  • Byeong-Geun Shin;Seong-Min Ahn
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.809-817
    • /
    • 2023
  • Single source and dual source measurements using anthropomorphic phantoms in which the phantoms are lined up in human body equivalents use OSLD (Optically Stimulated Luminescence Dosimeter), so the effective dose is calculated using OSLD. For hospital images, SNR (Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were measured in MCA (Middle Cerebral Artery) for single source and dual source, and for phantom images, SNR and CNR were measured for brain parenchyma of single source and dual source. For hospital imaging, SNR and CNR were measured in MCA for both single-source and dual-source, and for phantom images, SNR and CNR were measured for brain parenchyma from single-source and dual-source. As a result of comparing the SNR and CNR of the hospital image and the phantom image, there was no statistical difference. Comparing patient doses in hospital images, the effective dose of the dual source was 53.53% less and the effective dose of the dual energy phantom was 57.94% less. The dose can be increased in other areas, but the cerebrovascular area is useful because the dose is small.

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Comparison of Radiation Dose and Image Quality between the 2nd Generation and 3rd Generation DualSource Single-Energy and Dual-Source Dual-Energy CT of the Abdomen (2세대와 3세대 이중 소스 단일 에너지와 이중 소스 이중 에너지를 이용한 복부 컴퓨터단층촬영의 방사선량 및 영상 품질 비교)

  • Chang Gun Kim;See Hyung Kim;Seung Hyun Cho;Hun kyu Ryeom;Won Hwa Kim;Hye Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1342-1353
    • /
    • 2022
  • Purpose We compared the radiation dose and image quality between the 2nd generation and the 3rd generation dual-source single-energy (DSSE) and dual-source dual-energy (DSDE) CT of the abdomen. Materials and Methods We included patients undergoing follow-up abdominal CT after partial or radical nephrectomy in the first 10 months of 2019 (2nd generation DS CT) and the first 10 months of 2020 (3rd generation DS CT). We divided the 320 patients into 4 groups (A, 2nd generation DSSE CT; B, 2nd generation DSDE CT; C, 3rd generation DSSE CT; and D, 3rd generation DSDE CT) (n = 80 each) matched by sex and body mass index. Radiation dose and image quality (objective and subjective qualities) were compared between the groups. Results The mean size-specific dose estimation of 3rd generation DSDE CT group was significantly lower than that of the 2nd generation DSSE CT (42.5%, p = 0.013) and 2nd generation DSDE CT (46.9%, p = 0.015) groups. Interobserver agreement was excellent for the overall image quality (intraclass correlation coefficient [ICC]: 0.8867) and image artifacts (ICC: 0.9423). Conclusion Our results showed a considerable reduction in the radiation dose while maintaining high image quality with 3rd generation DSDE CT as compared to the 2nd generation DSDE CT and 2nd generation DSSE CT.

Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리)

  • Eom, Jisoo;Kang, Sooncheol;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.443-451
    • /
    • 2017
  • Mammography is commonly used for screening early breast cancer. However, mammographic images, which depend on the physical properties of breast components, are limited to provide information about whether a lesion is malignant or benign. Although a dual-energy subtraction technique decomposes a certain material from a mixture, it increases radiation dose and degrades the accuracy of material decomposition. In this study, we simulated a breast phantom using attenuation characteristics, and we proposed a technique to enable the accurate material decomposition by applying weighting factors for the dual-energy mammography based on a photon-counting detector using a Monte Carlo simulation tool. We also evaluated the contrast and noise of simulated breast images for validating the proposed technique. As a result, the contrast for a malignant tumor in the dual-energy weighted subtraction technique was 0.98 and 1.06 times similar than those in the general mammography and dual-energy subtraction techniques, respectively. However the contrast between malignant and benign tumors dramatically increased 13.54 times due to the low contrast of a benign tumor. Therefore, the proposed technique can increase the material decomposition accuracy for malignant tumor and improve the diagnostic accuracy of mammography.

Detection of Monosodium Urate Crystal of Hand and Wrist in Suspected Gouty Arthritis Patients on Dual-Energy CT and Relationship with Serum Urate Level (손과 손목의 통풍관절염에서 이중에너지 CT를 이용한 요산나트륨 결정 검출과 혈중 요산 농도와의 관계)

  • Hana Choi;Jeongah Ryu;Seunghun Lee;Yeo Ju Kim;Soyoung Bang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.212-225
    • /
    • 2023
  • Purpose We retrospectively investigated the characteristics of patients with monosodium urate (MSU) deposits of the hand and wrist on dual-energy CT (DECT) compared to those without. We also attempted to determine the pattern of MSU distribution in DECT. Materials and Methods In total, 93 patients were included who had undergone DECT for evaluation of the hand or wrist pain under the clinical impression of gouty arthritis. The total volume of MSU deposits on DECT was calculated and the pattern of MSU distribution on DECT was analyzed. Also, the level of the serum urate at the time of DECT and the highest level of the serum urate of the patients were obtained from their records and the relationship between MSU and serum urate level was evaluated. Results The range of the volume of MSU deposits on DECT was 0.01-16.11 cm3 (average: 1.07 cm3). The average level of serum urate was significantly higher in the MSU positive group than that in the MSU negative group. MSU deposits were most frequently observed in the wrists followed by fingers and digitorum tendons. Conclusion On DECT, MSU deposits were most frequently detected in the wrist and related with high serum urate level.

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

Clinical Application of the Dual Energy Photon Beam Using 6 MV and 10 MV X-ray (6MV 및 10 MV X-ray의 이중에너지를 생성하는 방사선 발생장치의 임상적 이용)

  • Lee, Myung-Za;Han, Hye-Gyeong
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.93-99
    • /
    • 1988
  • Some modern accerelators provide a dual energy for photon beam treatment. The main advantages of dual energy in the treatment of rectosigmoid or rectal cancer are as fellows. 1. Dose in the critical organ such as small intestine, bladder and genital organ are reduced. 2. Presacral and perineal area is fully covered. Dose distribution analysis such as calculation of dose in a target volume, isocenter, $D_{nax}$ and dose spectrum in any region of interest are possible. Examples of plan are given and results are discussed.

  • PDF

Development of Dual Energy Radiation Detector (이중 에너지 방사선 검출기 개발)

  • Yeo, Hwa-Yeon
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.3
    • /
    • pp.5-11
    • /
    • 2010
  • In this paper, we are suggested development of dual-mode detector for dual-energy digital radiography. Design of dual-energy radiography module for commercial BIS (Baggage Inspection System) is used in the spectrum of the X-ray generator and detector for dual-mode features and radiological characteristics were analyzed. BIS suggestl on the image detector module being used to target X-ray tube to simulate X-ray spectrum and simulated spectrum to offer through the new radiographic characteristics of the detector modules were investigated. Using X-ray experiments with an increase in the thickness of the copper filter low energy detector (LED) and high-energy detector (HED) as the difference between the output signal increases. HED, especially in the size of the output signal decreases with increasing thickness of the copper filter was found.

Remote Field Energy Flow Path at Nonmagnetic Coaxial Tubes (비자성체 이중관의 원격장 에너지 전달 경로)

  • Yi, Jae-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.526-531
    • /
    • 2001
  • The flow of remote field eddy current energy is studied at nonmagnetic coaxial tubes by using both experiments and finite element calculations based on commercial software package. The results showed that remote field eddy current energy at coaxial tubes flow along over the outer surface of external tube, not through the gap between internal and external tubes. This means that the through wall transmission characteristic of remote field eddy current testing (RFECT) is still valid at tube in tube configurations and the RFECT could be potential nondestructive technique for crack detection, spacer location and gap sizing at the coaxial CANDU fuel channel tubes.

  • PDF

Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode (뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.961-968
    • /
    • 2019
  • The purpose of this study was to evaluate the usefulness of cerebral angiography in each energy level by using dual energy technique in CT. Methods were performed on 15 DE images and SE images of CT angiography. For the analysis of images, mean value, standard deviation, SNR and CNR value were determined by setting ROI on MCA, brain parenchyma tissue, and back ground. As a result of concurrent visual evaluation with Likert 5 point scale, the clearest MCA image was confirmed at DE 40 keV and SE 120 kVp(p>0.05). The SNR value of the SE image was measured to be similar to the 40 keV energy level of the DE image. The low energy level image of 40 keV and 50 keV was measured with a high SNR and the contrast ratio was higher than that of the high energy image.