• Title/Summary/Keyword: 이음부 강성

Search Result 60, Processing Time 0.023 seconds

Compressive Stress Distribution of High Tension Bolted Joints (고장력 볼트 이음부의 내부 압축응력 분포)

  • Kim, Sung Hoon;Lee, Seung Yong;Choi, Jun Hyeok;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.171-179
    • /
    • 1997
  • The high-tension bolted joints are clamped by the axial force which approaches the yielding strength. The introduced axial force is transmitted to the connection members pass through washer. The transferred load in connections is balanced to the compressive stress of plates, axial force in bolts and the external loads. In this mechanism, the compressive stress and slip load we dominated by the effective stiffness of bolted joints and plates. In general the effective stiffness is specified to product to the effective area and elasticity modulus in connections. In this reason, the conic projection formular which is assumed that the axial force in bolts is distributed to the cone shape and that region is related to the elastic deformation mechanism in connections, was proposed. But it conclude what kind of formula is justified. Therefore in this paper, the fatigue tests are performed to the high tension bolted joints and inspected to the phase on the friction face. And using the FEM and numerical method, it is analyzed and approximated to the compressive stress distribution and its region. Moreover, it is estimated to the effective area and to the relation the friction area to the effective compressive distribution region.

  • PDF

A comparative study on methods for shield tunnel segment lining sectional forces (쉴드 터널 세그먼트 라이닝의 부재력 산정법 비교연구)

  • Yoo, Chung-Sik;Jeon, Hun-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.3
    • /
    • pp.159-181
    • /
    • 2012
  • The segment lining which consists of segments and joints are main component of shield tunnel. There are a number of methods that are being used in design which compute the sectional forces of a ring of segment lining. The traditional design methods which do not consider the effect of joints have been commonly used for design procedure without a specific verification of structural analysis. This paper presents the result of a comparative study for analytical and numerical models of the shield tunnel segment lining. For the traditional methods, the elastic equation method and the Duddeck & Erdmann method were considered. The ring-beam and the continuum analysis model were also considered as the numerical model.

Cyclic Behavior of Wall-Slab Joints with Lap Splices of Coldly Straightened Re-bars and with Mechanical Splices (굽힌 후 편 철근의 겹침 이음 및 기계적 이음을 갖는 벽-슬래브 접합부의 반복하중에 대한 거동)

  • Chun, Sung-Chul;Lee, Jin-Gon;Ha, Tae-Hun
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.275-283
    • /
    • 2012
  • Steel Plate for Rebar Connection was recently developed to splice rebars in delayed slab-wall joints in high-rise building, slurry wall-slab joints, temporary openings, etc. It consists of several couplers and a thin steel plate with shear key. Cyclic loading tests on slab-wall joints were conducted to verify structural behavior of the joints having Steel Plate for Rebar Connection. For comparison, joints with Rebend Connection and without splices were also tested. The joints with Steel Plate for Rebar Connection showed typical flexural behavior in the sequence of tension re-bar yielding, sufficient flexural deformation, crushing of compression concrete, and compression rebar buckling. However, the joints with Rebend Connection had more bond cracks in slabs faces and spalling in side cover-concrete, even though elastic behavior of the joints was similar to that of the joints with Steel Plate for Re-bar Connection. Consequently, the joints with Rebend Connection had less strengths and deformation capacities than the joints with Steel Plate for Re-bar Connection. In addition, stiffness of the joints with Rebend Connection degraded more rapidly than the other joints as cyclic loads were applied. This may be caused by low elastic modulus of re-straightened rebars and restraightening of kinked bar. For two types of diameters (13mm and 16mm) and two types of grades (SD300 and SD400) of rebars, the joints with Steel Plate for Rebar Connection had higher strength than nominal strength calculated from actual material properties. On the contrary, strengths of the joints with Rebend Connection decreased as bar diameter increased and as grade becames higher. Therefore, Rebend Connection should be used with caution in design and construction.

A study on the factors influencing the segment lining design solved by beam-spring model in the shield tunnel (쉴드 터널 세그먼트 라이닝 설계에서 빔-스프링 구조 모델이 단면력에 미치는 영향)

  • Kim, Hong-moon;Kim, Hyun-su;Shim, Kyung-mi;Ahn, Sung-youll
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.179-194
    • /
    • 2017
  • The segment lining design for shield tunnel is generally carried out by using the beam-spring model and the induced member forces from the model are strongly influenced by the components of the model such as imposed load, coefficient of subgrade reaction, location of segment joint and its stiffness. The structural models and stiffness of its connection part found used in abroad design cases is usually obtained as it is for the domestic design of segment of shield tunnel. Those models and stiffness in existing design cases are conventionally applied to a new tunnel design without any suitability review for the project. In this study, the application method of base components of the model such as the coefficient of subgrade reaction and modelling method to the segment lining design was suggested by carrying out the comparative study of the base elements for the member forces estimation of segment lining of shield tunnel.

The Study of Longitudinal Joint with Tensile Grip Connection in Highway Bridges (교축방향 인장이음에 관한 연구)

  • Seo, Seung-Tag
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.2
    • /
    • pp.155-160
    • /
    • 2006
  • 합성상판을 시공하는 경우 교축방향에 분할된 저강판을 접합 일체화해야 한다. 본 논문에서는 강 콘크리트 합성상판을 대상으로 3종류의 배력철근 방향 이음구조를 제안하며, 보 공시체에 의한 정적 정점피로 실험한다. 그 결과 보의 피로실험 결과 저강판 혹은 고력볼트가 피로파단 하였으며, 3차원 FEM해석에 이음부의 휨 강성도 및 피로강도에 대해서 해석적으로 검토된다.

  • PDF

Simple structural model of Heunginjimun with coulomb friction (흥인지문의 쿨롱 마찰력을 도입한 단순 해석모델)

  • Park, Sung-Ah;Min, Kyung-Won
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.516-520
    • /
    • 2011
  • 본 논문에서는 먼저 흥인지문에 대해 상시진동실험을 수행하고, 그 데이터를 분석하여 흥인지문의 고유진동수, 모드, 감쇠비의 특성을 분석하였다. 그 결과로부터 흥인지문의 병진모드를 파악하였고, 병진모드에서 측정한 여러 기둥의 모드 상대크기와 위상이 동일함을 확인하였다. 저차 병진모드에서 모든 기둥이 같은 방향으로 강성을 발휘하기 때문에 각층의 강성을 합한 등가의 층강성을 가지는 2자유도의 동적강체해석모델을 제시하였다. 이 해석모델은 선형 범위 내에서 거동한다는 것으로 가정하여 층강성을 산정하였다. 실제 흥인지문의 접합부에는 부재간의 이음과 맞춤에 의한 마찰력이 작용한다. 접합부를 누르는 무거운 지붕하중에 의해 이 마찰력은 증가하게 되고, 이로써 횡하중에 저항하게 된다. 이러한 접합부에 강한 횡하중이 작용하게 되면, 접합부의 이완 및 마찰력의 저하 등으로 인하여 횡강성의 저하가 급격히 일어나는 비선형 특성을 갖게 된다. 이러한 흥인지문의 비선형적인 특성을 파악하기 위해 흥인지문 해석모델에 쿨롱 마찰력을 도입하여 비선형적인 해석모델을 제시하였다.

  • PDF

Prying Action of Spliced Reinforcements in Tension (인장 겹침이음에서 프라이 거동의 영향)

  • Chun, Sung-Chul;Choi, Dong-Uk;Ha, Sang-Su;Oh, Bo-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1085-1088
    • /
    • 2008
  • Splice of reinforcement is inevitable in reinforced concrete structures and, generally, lap splices are used. Lap length for tension splice is determined from development length in tension. The development length is calculated from an experimental model which was based on data of tests on anchorage and splice. Longitudinal reinforcements in flexural members are deformed and, therefore, prying action happens in spliced reinforcements unlike anchored reinforcements. The prying action induces tensile stress in cover concrete and this tensile stress plays the same role to a circumferential tensile stress caused by bond. Because splitting failure is assumed to occur when the summation of tensile stresses caused by the prying action and the bond is equal to the tensile strength of the concrete, the prying action reduces the bond strength of spliced reinforcements. A theoretical model for the prying action is developed and effects of the prying action on the bond strength are assessed. The tensile stress by the prying action is proportional to tensile strength and modulus of elasticity of reinforcements. In addition, the tensile stress is inversely proportional to spacing of reinforcements. Consequently, longer splice length is required for spliced reinforcements with small spacing in flexible members.

  • PDF

Method of assessment for allowable size of weld defects (熔接缺陷의 許容限界 評價方法)

  • 강성원
    • Journal of Welding and Joining
    • /
    • v.9 no.3
    • /
    • pp.10-17
    • /
    • 1991
  • 용접구조물에서 용접이음부가 차지하는 비율은 매우 작은 경우가 많지만 용접이음부에는 각종 초기결함(이들 결함으로부터 진전하는 피로 균열, 환경에 의한 균열등을 포함) 및 용접 초기의 부정형을 비롯해서 형상적 불연속 등에서 유기되는 국부적인 응력, 변형률의 집중, 잔류응력, 구속응력, 용접금속이 갖는 숙명적인 야금적 특성의 불균일, bond부 및 HAZ부에서의 용접열 싸이클에 의한 재질의 국부적 강도저하등 용접부의 강도를 저하시키는 인자들이 복합되기 쉽고, 용접구조물 전체의 내파괴 건전성평가에서 용접부가 파괴 강도는 매우 중요하다. 용접구조물의 설계, 시공의 목적은 소요성능의 확보에 있고 구조물이 사용중에 성능손실이나 불안정 파괴가 발생하지 않도록 하는 것이 주요요건이 될 것이다. 현재의 제강기술수준에서 볼 때 모재의 강 도보다 오히려 용접부의 강도 특히 피로강도 및 파괴 인성을 적절하고 합리적으로 평가하는 것이 매우 중요하다고 해도 과언이 아닐 것이다. 용접부의 강도를 평가하는데 있어서 용접부에 발 생하는 용접결함에 대한 평가는 매우 중요하며 이들 결함에 대한 허용결함한계를 평가하여 보수 여부 및 용접구조물의 신뢰성을 평가 할 필요가 있다.

  • PDF

Slip Behavior of High-Tension Bolted Joints Subjected to Compression Force (압축력을 받는 고장력 볼트 이음부의 미끄러짐 거동)

  • Han, Jin Hee;Choi, Jong Kyoung;Heo, In Sung;Kim, Sung Bo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.279-288
    • /
    • 2008
  • In this study, the slip behavior of high-tension bolted joints subjected to compression force is investigated through 3D finite element analysis and experiments. The relation with sliding load, bolt deformation, and failure load are studied with the metal thickness affecting the bolted joint. The post-sliding behavior considering bolt stiffness is presented and compared with the results by finite element and experiments. The finite element model is constructed by solid elements in ABAQUS, in consideration of all the friction effects between metal plates and bolts. The stress-strain relations in the literature are used, and the sliding displacements and axial stresses around the bolt connection are investigated. The flexural buckling of species happened when the plate thickness is less than the bolt diameter. However, the shear failures of bolt occurred in the opposite case.