Development of Chemical Cleaning Agents for Cleaning Indoor Water Supply Pipes (옥내급수관 세척용 화학세정제 개발 연구)

  • Lee, Jae-Hoon;Jung, Jae-Yong;Park, Yong-Bae;Bae, Jae-Heum;Woo, Dal-Sik;Sin, Hyun-Duk
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.162-171
    • /
    • 2010
  • The objective of this study is to develop cleaning agents for the indoor water supply pipe which is environmentally friendly and suitable for removing scale by using various organic acids, inorganic acids, and some additives. Among various organic acids, oxalic acid, citric acid, and malic acid showed good cleaning efficiency of iron oxides which were main components of the indoor water supply pipe scale. Several cleaning agents were formulated by adding chemical additives into these organic acids and evaluated for removal of iron oxides. In this study, it was found that nonionic surfactants were excellent for the removal of iron oxide scale among various additives. Two types of cleaning agents($F_1$, $F_2$) with comparatively high solvent power for iron oxides were formulated in this study. The cleaning agents $F_1$ made by organic acids and some additives were formulated to be safe and environmentally friendly, but seemed to have disadvantage due to their comparatively low cleaning efficiency of iron oxide than $F_2$. But, the cleaning agents $F_2$ prepared by adding inorganic acid a little to $F_1$ showed comparatively good cleaning efficiency of iron oxide and could be recommended for removing hard scale of iron oxides in the indoor water supply pipe. Thus, it is considered that the formulated cleaning agents should be selected based on the extent of scale in the indoor water supply pipe.

A Study on the Performance Variations of Liquid-crystal Aqueous Cleaning Agents with their Formulating Components and Mixing Ratios (액정 세척용 수계 세정제의 배합성분과 혼합비에 따른 성능 변화)

  • Jeong, Jae-Yong;Lee, Min-Jae;Bae, Jae-Heum
    • Clean Technology
    • /
    • v.16 no.2
    • /
    • pp.103-116
    • /
    • 2010
  • It has been reported that the LCD panel market in the FPD industry is become growing and its panel size and production capacity are increasing, and its manufacturing technique is improved every year. FPD manufacturing process requires high cleanliness in its overall process. Especially, FPD cleaning process which accounts for 30~40% of total manufacturing process is very important in its technological and productivity aspects. It is difficult to remove residual liquid-crystal in the fine gap after liquid-crystal injection process in the cell. In this study, aqueous cleaning agents with excellent cleaning, rinsing, and penetrating abilities, but minimum ion content for LCD panel were formulated through mixing glycol ether-type and glycol dimethyl ether-type solvents and nonionic surfactants which are widely used as raw materials for alternative cleaning agents because of environmental regulation at home and abroad. And the formulated cleaning agents were applied to clean FPD liquid crystal after its injection in the cell. Physical properties, cleaning efficiencies, and rinsabilities of the formulated cleaning agents with different combination ratios of solvents, surfactants and additives were measured. As experimental results, the formulated cleaning agents showed higher wetting indices and cloud point than the traditional commercial cleaning agent. And it was found that cleaning efficiencies of the formulated cleaning agents were influenced by the structure of main solvents in them and the types of liquid crystal as soil for cleaning. The best cleaning agents among the formulated cleaning agents showed similar cleaning efficiencies and better rinsabilities compared to the conventional cleaning agent.

A New Method For Measuring Acupoint Pigmentation After Cupping Using Cross Polarization (교차편광 촬영술(Cross Polarization Photographic Technique)를 이용한 부항요법의 배수혈 피부 색소 침착 변화 측정 평가)

  • Kim, Soo-Byeong;Jung, Byungjo;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.252-263
    • /
    • 2013
  • Objectives : Skin color deformation by cupping has been widely used as a diagnostic parameter in Traditional Korean Medicine(TKM). Skin color deformation such as ecchymoses and purpura is induced by local vacuum in a suction cup. Since existing studies have relied on a visual diagnostic method, there is a need to use the quantitative measurement method. Methods : We conducted an analysis of cross-polarization photographic images to assess the changes in skin color deformation. The skin color variation was analyzed using $L^*a^*b^*$ space and the skin erythema index(E.I.). The meridian theory in TKM indicates that the condition of primary internal organs is closely related to the skin color deformation at special acupoints. Before conducting these studies, it is necessary to evaluate whether or not skin color deformation is influenced by muscle condition. Hence, we applied cupping at BL13, BL15, BL18, BL20 and BL23 at Bladder Meridian(BL) and measured blood lactate at every acupoint. Results : We confirmed the high system measurement accuracy, and observed the diverse skin color deformations. Moreover, we confirmed that the $L^*$, $a^*$ and E.I. had not changed after 40 minutes(p>0.05). The distribution of blood lactate levels at each part was observed differently. Blood lactate level and skin color deformation at each part was independent of each other. Conclusions : The negative pressure produced by the suction cup induces a reduction in the volumetric fraction of melanosomes and subsequent reduction in epidermal thickness. The relationship between variations of tissue and skin properties and skin color deformation degree must be investigated prior to considering the relationship between internal organ dysfunction and skin color deformation.

Body Composition Factor Comparisons of the Intracellular Fluid(ICW), Extracellular Fluid(ECW) and Cell Membrane at Acupuncture Points and Non-Acupuncture Points by Inducing Multiple Ionic Changes (생체이온 변화 유발 후 경혈과 비경혈에서의 생체 구조 성분 분석 및 비교를 통한 경혈 특이성 고찰)

  • Kim, Soo-Byeong;Chung, Kyung-Yul;Jeon, Mi-Seon;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.31 no.2
    • /
    • pp.66-78
    • /
    • 2014
  • Objectives : The specificity of acupuncture point has been a highly controversial subject. Existing researches said that ion-distribution differences are observed on the acupuncture point. This study was conducted under the assumption that multiple ionic changes induced by muscle fatigue would be different between the acupuncture point with non-acupuncture point. Methods : To induce the identical fatigue, twenty subjects performed the knee extension/flexion exercise using the Biodex System 3. ST32 and ST33 as well as adjacent non-acupuncture points were selected. We measured blood lactate and analyzed the median frequency(MF) and peak torque. To obtain the information on the extracellular fluid(ECW), intracellular fluid(ICW) and cell membrane indirectly, we used the multi-frequency bioelectrical impedance analysis(MF-BIA) method. Results : MF, peak torque and blood lactate level of all measurement sites were gradually returned to normal. Re resistance of ST32 had a stronger response, but a non-acupuncture point adjacent to ST33 had a larger response up to 20 minutes post exercise. Ri resistances were similar for both acupoints and non-acupoints. The $C_m$ capacitance of ST32 had a stronger response after inducing fatigue, but ST33 had a smaller response than a non-acupuncture point adjacent to it. Conclusions : In comparison with before and after inducing fatigue, the specificity of acupuncture points was not clearly observed. Hence, we concluded that the body composition factors extraction method had the limitation as a method of finding the specificity of acupuncture points by inducing fatigue.

Study on the Change of Nutrients Contents according to the Use of various Multi-Functional Grinder (믹서의 종류에 따른 영양소 함량 변화에 대한 연구)

  • Choi, Byung Bum;Kim, Chun Huem;Kim, Young Soon
    • Culinary science and hospitality research
    • /
    • v.20 no.6
    • /
    • pp.262-274
    • /
    • 2014
  • In this study, changes of nutrients such as vitamins, minerals, and antioxidants were determined by using a multi-functional grinder. Contents of vitamin C and vitamin $B_1$ were measured by HPLC, and antioxidant activity was estimated toward free radical scavenging effect in using DPPH. Contents of minerals(Zn, Mn, Fe, Mg, K, and Ca) were computed by ICP-Mass. Results identified that the contents of vitamin C was $44.06{\pm}10.86mg/kg$ in mandarine, $132.1{\pm}22.80mg/kg$ in orange, and $12.79{\pm}2.01mg/kg$ in pineapple by using the hand blender for 3 minutes, and the loss rate of vitamin C contents were 12%, 7%, and 12% in comparison with the control group. In addition, the contents of vitamin C were $41.89{\pm}5.55mg/kg$ in mandarine, $131.51{\pm}12.67mg/kg$ in orange and $16.76{\pm}1.47mg/kg$ in pineapple when using of the grinder for 3 minutes, and the loss rate of vitamin C contents were 16%, 8%, and 17%. The results of vitamin $B_1$ showed a tendency to decrease in the same manner as the content of vitamin C even if there was no significant difference. Furthermore, the result of antioxidant activity revealed that free radical scavenging effect of sample was 60% decreased when using a hand blender and 10% decreased when using a grinder. Thus decrease rate of antioxidant activity when using the hand blender was higher than grinder. Lastly, current study could find any significant differences among the 16 food samples for cooking when employing the multi-functional grinder(p<0.05).

Effects of Some Factors on In Vitro Production of Embryos from Antral Follicle-Derived Porcine Oocytes III. Effects of Fertilization Media and the Sperm Concentration during Fertilization on In Vitro Fertilization and Development (돼지 난포란 유래 체외수정란 생산에 대한 제요인의 영향 III. 체외수정배양액과 정자농도가 체외수정 및 체외발달에 미치는 영향)

  • Yeon S. H.;Son D. S.;Jean H. J.;Choi S. H.;Kim I. C.;Park C. S.;Lee K. S.
    • Journal of Embryo Transfer
    • /
    • v.19 no.3
    • /
    • pp.265-273
    • /
    • 2004
  • This study was carried out to examine the effects of fertilization media and sperm concentration on in vitro fertilization (IVF) and development (IVD) of porcine oocytes matured in vitro. Cumulus-oocyte complexes (COCs) were collected from antral follicles of porcine ovaries collected from abattoir, and were matured in vitro in modified NCSU-23 (mNCSU-23) supplemented with 10% porcine follicular fluid (pFF). After the fertilization by experimental scheme, putative embryos were developed in vitro in NCSU-23. The results are as follows. When the oocytes were fertilized in vitro in modified TBM or modified TLP-PVA by 1 ${\times}$10$^{5}$ sperm/$m\ell$, all of the fertilization parameters were not significantly different between two media. Subsequently, as these putative embryos were developed in vitro in NCSU-23, the percentage of oocytes cleaved and of blastocysts were not different between two media, either. When the oocytes were fertilized in vitro in mTBM by 5${\times}$10$^4$, 1${\times}$10$^{5}$ or 5${\times}$10$^{5}$ sperm/$m\ell$, all of the fertilization parameters were significantly (P<0.05 or P<0.01) increased as sperm concentration was elevated. Subsequently, as these putative embryos were developed in vitro in NCSU-23, the percentage of oocytes cleaved and of blastocysts were significantly boosted (P<0.01) as sperm concentration at fertilization was elevated from 5${\times}$10$^4$ to 1${\times}$10$^{5}$ sperm/$m\ell$, but were not different between 1${\times}$10$^{5}$ and 5${\times}$10$^{5}$ sperm/$m\ell$.

Analysis of body surface temperature by Pulsed Magnetic Fields system for evaluation of therapeutic effect of Delayed Onset Muscle Soreness (지연성 근육통증 회복 평가를 위한 경혈 부위에서의 자기장자극에 대한 체열변화 분석)

  • Lee, Na-Ra;Lee, Seung-Wook;Kim, Young-Dae;Kim, Soo-Byeong;Lee, Kyong-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.3
    • /
    • pp.645-653
    • /
    • 2011
  • The aim of this study was to develop a Pulsed Magnetic Fields(PMFs) system which can produce effects locally and simulate muscular tissues equally. To evaluate the PMFs system we caused DOMS(Delayed Onset Muscle Soreness) to subjects in biceps of the arm. Then, we stimulated acupoint HT2 using PMFs(20 minutes) and TEAS(20 minutes) for 2 days. The other subjects did not stimulate. Then we checked body surface temperature in biceps of the arm. All subjects had an asymmetrical body surface temperature in biceps after exercise(Non-stimulation group=$2.00{\pm}1.16^{\circ}C$, TEAS group=$1.73{\pm}0.52^{\circ}C$, PMFs group=$1.48{\pm}0.51^{\circ}C$). After 1st stimulation all subjects had decreased temperature differences(Non-stimulation group=$1.37{\pm}0.71^{\circ}C$, TEAS group=$1.08{\pm}0.43^{\circ}C$, PMFs group=$1.23{\pm}0.15^{\circ}C$). PMFs group had a symmetry body surface temperature after 24 hours($0.05{\pm}0.06^{\circ}C$) and TEAS group had that after 48 hours($0.1{\pm}0.08^{\circ}C$). Non-stimulation group did not recovery after 48 hours($0.37{\pm}0.06^{\circ}C$). Therefore, PMFs on acupoint had an therapeutic effect in DOMS.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

The Change of Cortical Activity Induced by Visual Disgust Stimulus (시각혐오자극으로 유발된 대뇌 피질 활성도 변화)

  • Jung, Wook;Park, Doo-Heum;Yu, Jae-Hak;Ryu, Seung-Ho;Ha, Ji-Hyeon;Shin, Byoung-Hak
    • Sleep Medicine and Psychophysiology
    • /
    • v.20 no.2
    • /
    • pp.75-81
    • /
    • 2013
  • Objectives: There are a lot of studies that analyze the interaction between the emotion of disgust and the functional brain images using fMRI and PET. But studies using sLORETA (standardized low resolution brain electromagnetic tomography) almost do not exist. The aim of this research is to explore the relationship of the emotion of disgust and the cortical activation using sLORETA analysis. Methods: Forty five healthy young adults ($27.1{\pm}2.6$ years) participated in the study. While they were watching 4 neutral images and 4 disgusting images associated with mutilation selected from the international affective picture system (IAPS), participants' EEGs were taken for 30 seconds per one picture. Through these obtained EEG data, sLORETA analysis was performed to compare EEGs associated with neutral and negative images. Results: During looking for visual disgusting stimulus, all participants reported unpleasantness, arousal and stress. In sLORETA analysis, the decrease of current density in theta wave was shown at left frontal superior gyrus (BA10) and middle gyrus (BA10, 11). This voxel cluster consists of a total of 11 voxels and the threshold of t value indicating statistically significant decreases in the current density (p<0.05) was -1.984. There were no differences between male and female in the degree of being disgusted by the stimuli. Conclusion: This finding may suggest that the activation of dorsolateral prefrontal cortex might be associated with regulating disgust emotion.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF