• Title/Summary/Keyword: 이온 손실

Search Result 197, Processing Time 0.035 seconds

Losses of Chemical Components by Infiltration Water during the Rice Cultivation at Silt Loam Paddy soil (영농기간 지하침투수에 의한 미사질양토 논의 화학성분 손실량)

  • Han, Kang-Wan;Cho, Jae-Young;Son, Jae-Gwon
    • Korean Journal of Environmental Agriculture
    • /
    • v.17 no.3
    • /
    • pp.268-273
    • /
    • 1998
  • Changes of chemical component and losses of chemical fertilizer by infiltration water from 0.5ha of paddy field in Chinan area of Chonbuk province during the rice cultivation were investigated. The infiltration water samples were collected in a ceramic porous cup which was a buried at the 30, 50, 70, 90㎝ of soil depth. pH of infiltration water ranged $6.64{\sim}7.90$ and EC showed $324{\sim}647{\mu}$S/cm. The content of total-N, $NH_4-N$ and $NO_3-N$ were $0.58{\sim}14.59$, $0.05{\sim}4.25$, and $0.15{\sim}7.71mg/L$ respectively. The content of total-P and ortho-P were $0.009{\sim}0.077mg/L$ and $0{\sim}0.029mg/L$ The content of $Ca^{++}$, $Mg^{++}$, $Na^{+}$ and $K^{+}$ showed $0.88{\sim}4.78$, $0.22{\sim}1.04$, $0.17{\sim}0.98$, and $0.84{\sim}3.19㎎/L$. These all at the first transplanting are higher than that of other periods. The content of $SO_4^{2-}$ showed $3.92{\sim}18.72mg/L$ and decreased with a soil depth. However $Cl^-$ of infiltration water ranged $9.03{\sim}19.97mg/L$ and no difference with a soil depth. When infiltrated $2,416.5m^{3}$ of an infiltration water from 0.5ha of paddy field during the rice cultivation, losses of chemical components were 20.34㎏/㏊ of total-N, 3.54㎏/㏊ of $NH_4-N$, 10.44㎏/㏊ of $NO_3-N$, 0.16㎏/㏊ of total-P and 0.028㎏/㏊ of ortho-P. Also $Ca^{++}$, $Mg^{++}$, $Na^+$, $K^+$, $SO_4^{2-}$ and $Cl^-$ were lost 10.24, 2.84, 2.84, 7.22, 50.04 and 62.20㎏/㏊ respectively. There were lost by infiltration water 9.35% of nitrogen, 0.59% of phosphorous and 22.79% of potassium in applied chemical fertilizer.

  • PDF

Evaluation of Biological and Physico-chemical Detoxification Methods for the Removal of Inhibitors in Lignocellulose Hydrolysate (목질계 바이오매스 가수분해물 중 발효저해 물질에 대한 생물학적 및 물리화학적 무독화 방법의 평가)

  • Cho, Dae-Haeng;Kim, Yong-Hwan
    • KSBB Journal
    • /
    • v.24 no.5
    • /
    • pp.415-419
    • /
    • 2009
  • In this study, the detoxification methods were evaluated for the removal of fermentation inhibitors from synthetic solution containing the composition similar to the lignocellulosic hydrolysate. The enzyme peroxidase and laccase were used as a biological treatment method. The physico-chemical methods such as adsorption and ion exchange were applied by using activated charcoal and ion exchange resins. The enzyme peroxidase showed a excellent removal of phenolic compounds. The 5-HMF and furfural were completely removed by activated charcoal. The anion exchange resin showed a good result for detoxification of acetic acid. The activated charcoal and ion exchange resins lead to a loss of sugars more or less. The choice of detoxification method must be made after considering the composition and inhibitors in hydrolysates.

The Environmental Control of $Er^{3+}$ ions in $R-SiO_2/ZrO_2$ Sol-Gel Matrix ($R-SiO_2/ZrO_2$ 졸-겔 재료내 $Er^{3+}$이온의 결합 환경 제어)

  • 김주현;권정오;석상일;안복엽
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.03a
    • /
    • pp.224-224
    • /
    • 2003
  • 광통신을 위한 구성 요소는 빛을 발생시키는 발광소자, 빛을 검출하는 수광소자 그리고 광신호를 처리하는 광신호처리 소자로 구성된다. 이때 각 소자간 광전송과 광소자에 의한 광 신호 처리 과정에서 광전송 손실이 심각하게 일어나 광정보를 상실하게 되므로 각 요소별로 광신호 증폭이 반드시 필요하다. 뿐만 아니라 완전 광화에 의한 초고속/대용량 광통신망의 구축에는 저가이며, 광집적화가 가능한 광도파로형 광증폭기가 요구되고 있다. 짧은 거리에 높은 증폭 효율을 얻기 위한 광도파로형 광증폭기를 구현하기 위해서는 광통신 파장대인 1.55$\mu\textrm{m}$ 대역의 증폭이 가능한 Er 이온을 고농도로 도핑 할 필요가 있다. 그러나 Er 이온을 단순히 고농도로 첨가하면 Er-Er 간 뭉침 현상에 의해 더 이상의 증폭이 어렵게 된다. 본 연구에서는 이러한 문제를 해결하면서 스핀 코팅이 가능하여 저가 공정이 가능한 유/무기 졸-겔 재료 내에 Er 이온을 제어된 방법으로 첨가하고 그 결합 환경을 FT-IR 및 $^{17}$ O-NMR로 분석하였다. 유/무기 졸겔 재료 제조를 위하여 먼저 MPTS(MethAcryoxyPropylTrimethoxySilane)를 부분 가수분해한 후 ZrOCl$_2$.8$_2$O (Zirconyl Chloride Octahydrate) 와 ErCl$_3$. 6$H_2O$ (Erbium(III) Chloride Hexahydrate)를 순차적으로 결합시키고, Zr/MPTS 및 Zr/Er의 첨가비에 따른 발광 특성을 PL(photoluminescence) 스팩트럼으로 분석하여 Er 이온의 주위 결합 환경이 PL에 미치는 영향을 조사하였다. 또한 Si 기판에 코팅한 Er이 도핑된 유/무기 하이브리드 졸-겔 코팅막의 굴절율 등 광도파로 재료로서의 특성도 프리즘 커플러 등을 이용하여 조사하였다.

  • PDF

이온주입 에너지에 따른 Auger Si KLL Peak Shift 및 Ti 계열 화합물의 Chemical State 관찰

  • Heo, Sung;Park, Yoon-Baek;Min, Gyung-Yeol;Lee, Sun-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.83-83
    • /
    • 1999
  • 본 연구에서는 Auger Elecrtron Spectroscopy (AES) 장비를 이용하여 Silicone Wafer 표면에 BF 이온을 주입시킨 후 Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화를 관찰하였다. 또한 PVD Ti 계열 화학물의 시료에 대하여 Peak의 Shape 변화를 관찰하였다. 1)Dopping 농도 및 Implantation 에너지에 따른 Si KLL Peak의 변화 관찰 일반적으로 Silicone 기판에 Arsenic(3가)을 Dopping 하였을 경우, Si KLL Peak의 Kinetic Energy 값은 순수 Si Peak보다 더 작은 값으로 Shift 하며, Boron (5가)을 Dopping하였을 경우에는 더 큰 값으로 Shift 한다. 이론적으로 N-type Si의 에너지 차이는 약 1.0eV로 보고되어 있으며, AES를 이용하여 실험적으로 측정된 값은 약 0.6eV정도로 알려져 있다. 이러한 차이는 Dopping 농도에 따라 Valance Band의 에너지 값이 변화하기 때문이라고 알려져 있다. 본 연구에서는 BF2를 Si에 이온 주입하여 입사 에너지 및 dose 량에 따른 Si KLL Peak의 변화를 관찰하였다. 그림1과 같이 Si KLL Peak는 Implantation Energy가 작을수록 Kinetic Energy가 높은 곳으로 Shift 한다. 이는 LOw Energy로 이온 주입하면, Projected Range (Rp)가 High Energy로 이온 주입할 때보다 작기 때문이며, 이 결과를 Secondary Ion Mass Spectroscopy (SIMS) 및 TRIM simulation을 이용하여 확인하였다. 또한 표면에서의 전자 Density의 변화와 Implantation energy와의 관계를 시료의 표면에서 반사되어 나오는 전자의 에너지 손실(Reflected Electron Energy Loss Spectroscopy:REELS)을 통하여 고찰하였다. 2) PVD Ti 계열화합물의 시료에 대한 peak의 shape 가 변화하며, TiL3M23V (Ti2) 및 TiL3M23M23 (Til) Peak의 Intensity Ratio가 변화한다. 따라서 본 연구에서는 그림 2와 같이 Ti 결합 화합물에서의 Ti Auger Peak의 특성 에너지 값과 Peak Shape를 관찰하여, AES를 이용하여 Ti 계열의 화합물에 대한 Chemical state 분석의 가능성을 평가하였다.

  • PDF

Preparation of Storage-Stable Liquid Dyes by Membrane Separation Technology (막분리 기술을 위한 액체염료 제조에 관한 연구)

  • Cho, Jung Hee;Lee, Chung Hak
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.349-359
    • /
    • 1992
  • Studies were carried out on the selective removal of inorganic salts such as NaCl and $Na_2SO_4$ from dye solution, using counter diffusion-reverse osmosis and nanofiltration, respectivey. For the dye solution used in the experiments, 1 to 30% of salts were removed by counter diffusion while the loss of dye molecules was less than 0.3%. The separation factors by one pass operation were 10-500 according to ionic species. In five successive operations, removals of anion($Cl^-$) increased but those of cation($Na^+$) decreased due to the Donnan effect. Effects of feed flow rate on removal efficiencies of various ions were also observed at constant flow rate of stripping water. Reverse osmosis of desalted dye solution by counter diffusion was conducted to prepare highly concentrated liquid dyes. The rejection efficiency of dye molecules was greater than 99%. For the rejection efficiency of chloride ion, experimental values were compared with theoretical ones based on solution-diffusion model. Two stage diafiltration was performed in nanofiltration. The rejection efficiency of chloride ion was continuously decreased due to the Donnan dialysis and even negative rejection was observed. The Donnan effect was more pronounced in the second diafiltration.

  • PDF

Proton induced Effects on Commercial Single-mode Optical Fibers (상용 단일모드 광섬유의 양성자 영향)

  • Kim, Jong-yeol;Kim, Young-woong;Ryu, Guk-been;Hwang, Young-gwan;Lee, Min-Woong;Song, Keun-young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.623-625
    • /
    • 2022
  • In this paper, the proton induced attenuation characteristics were evaluated for 5 types of commercial single-mode optical fibers using a proton accelerator. The proton beam used in the irradiation test has a high energy of 100 MeV class, and the test was performed by setting the uniformity of the beam irradiation area to 10% or less. According to the type of optical fiber (internal material, impurities), the radiation induced attenuation by the proton irradiation showed a noticeable difference.

  • PDF

집속렌즈계 요소기술 개발에 대한 연구

  • 이연진;구종모;노명근;정광호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.500-503
    • /
    • 2004
  • 본 연구에서는 금속 원자를 단열 팽창시켜 클러스터를 만들고, 생성된 클러스터를 이온화시킨 후 집속렌즈 및 electric quadrupole을 이용하여 기판으로 증착 하였다. 집속렌즈의 설계에서는 단일 초점 방식의 렌즈보다 성능을 높이기 위하여 이중 초점과 핀홀을 써서 집속 효과 및 효율을 높였다. 렌즈의 설계는 일반적으로 하전입자의 에너지 손실 없이 집속할수 있는 Einzel 렌즈를 기본으로 하였으며, SIMION software 를 사용하여 시뮬레이션 하였다. 시뮬레이션 후 실제 렌즈계 및 정전압원을 제작하여 금(Au)의 클러스터를 생성하여 렌즈계를 통과한 후 실제 기판위로 증착이 되는 것을 AFM(Atomic force microscopy)과 XPS(X-ray photoemission spectroscopy)를 이용해 조사하여 렌즈계가 실제로 동작함을 확인하였다.

  • PDF

Study of neutral beam characteristics using SIMS depth profile and improvement of neutral beam flux (SIMS depth profile을 이용한 중성빔 특성 분석 및 flux 향상방안)

  • Kim, Seong-U;Park, Byeong-Jae;Min, Gyeong-Seok;Gang, Se-Gu;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.61-62
    • /
    • 2007
  • low angle forward reflected neutral beam etching system으로 식각한 후 SIMS depth profile을 이용하여 에너지 침투 깊이에 따른 중성빔 에너지를 분석하여 중성화 과정에서 에너지와 flux의 손실이 있었다. 기존의 two-grid 대신에 three-grid를 사용하여 에너지의 변화없이 이온 flux 및 중성빔 flux가 향상됨을 알 수 있었다.

  • PDF

Determining Ion Collection Efficiency in a Liquid Ionization Chamber in Co-60 Beam (Co-60 빔에서 액체 전리함의 이온 수집 효율 결정 연구)

  • Choi, Sang Hyoun;Kim, Chan Hyeong
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.46-52
    • /
    • 2014
  • Liquid ionization chamber is filled with liquid equivalent material unlike air filled ionization chamber. The high density material allow very small-volume chamber to be constructed that still have a sufficiently high sensitivity. However liquid ionization chamber should be considered for both initial recombination and general recombination. We, therefore, studied using the Co-60 beam as the continuous beam and the microLion chamber (PTW) for comparing the ion collection efficiency by Greening theory, two-dose rate method and our experiment method. The measurements were carried out using Theratron 780 as the cobalt machine and water phantom and 0.6 cc Farmer type ionization chamber was used with microLion chamber in same condition for measuring the charge of microLion chamber according to the dose rates. Dose rate was in 0.125~0.746 Gy/min and voltages applied to the microLion chamber were +400, +600 and +800 V. As the result, the collection efficiency by three method was generally less than 1%. In particular, our experimental collection efficiency was in good agreement within 0.3% with Greening theory except the lowest two dose rates. The collection efficiency by two-dose rate method also agreed with Greening theory generally less than 1%, but the difference was about 4% when the difference of two dose rates were lower. The ion recombination correction factors by Greening theory, two-dose rate method and our experiment were 1.0233, 1.0239 and 1.0316, respectively, in SSD 80 cm, depth 5 cm recommended by TRS-398 protocol. Therefore we confirmed that the loss by ion recombination was about 3% in this condition. We think that our experiment method for ion recombination correction will be useful tool for radiation dosimetry in continuous beam.

Preparation of Porous Separators for Zn Air Batteries Through Phase Inversions of Polyethersulfone-PVP Solutions (Polyethersulfone-PVP 용액의 상전이를 통한 아연공기전지의 다공성 분리막 제조)

  • Cho, Yu Song;Koo, Ja-Kyung
    • Membrane Journal
    • /
    • v.24 no.1
    • /
    • pp.10-19
    • /
    • 2014
  • Porous flat sheet membranes for separators in Zn air batteries were prepared with polyethersulfone (PES) solutions by immersion precipitation phase inversion method. PES/polyvinylpyrrolidone(PVP)/N-methylpyrrolidone(NMP) mixtures were used for casting solutions and water was used for coagulant. With the separators, Zn air batteries were fabricated. The separators were characterized by means of stress-strain test, impedance test and SEM. The Zn air batteries were tested by current interrupt method (CIM) and galvanostatic discharge method. The tensile strength increased with increasing PES content in the casting solution while the ionic conductivity decreased. On the other hand, the ionic conductivity increased while the tensile strength decreased with increasing PVP content. The effect of ionic conductivity trend of the separator in the Zn air battery was confirmed through current interrupt method and galvanostatic discharge method experiments. The battery with the separator from casting solution with higher PES content showed higher IR drop and lower discharge capacity. And the battery with the separator from casting solution with higher PVP content showed lower IR drop and higher discharge capacity.