• 제목/요약/키워드: 이온 검출

Search Result 638, Processing Time 0.027 seconds

Characteristics of Low-power Microwave Induced Plasma Emission Spectrum and Detection of $CO_2$ (저출력 마이크로파 유도 플라스마 방출스펙트럼의 특성과 $CO_2$ 분석)

  • Noh, Seung Man;Park, Chang Joon;Kim, Young Sang
    • Journal of the Korean Chemical Society
    • /
    • v.40 no.4
    • /
    • pp.235-242
    • /
    • 1996
  • A surfatron-type microwave induced plasma (MIP) cavity has been constructed, which can be easily interfaced with a gas chromatograph. Various plasma gases such as He, Ar and N2 were used to generate the MIP and small amounts of CO2 gases were injected through the MIP to obtain characteristic spectrum of each plasma gas and to study feasibility of the MIP as a soft ionization source. Since He and Ar plasmas have high metastable state energy, it was not possible to detect sample gas in molecular state. With N2 plasma, however, a strong emission of molecular ions could be detected owing to its low metastable state energy.

  • PDF

Study on elemental analysis of metal and ceramic samples by using laser ablation ion trap mass spectrometry(LAITMS) (레이저 이온화 이온트랩 질량분석법을 이용한 금속 및 세라믹 시료의 원소분석에 관한 연구)

  • Song, Kyuseok;Park, Hyunkook;Cha, Hyungki;Lee, Sang Chun
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.7-14
    • /
    • 2002
  • Laser ablation ion trap mass spectrometry (LAITMS) was developed for the analysis of metal and ceramic samples. For this study, XeCl excimer laser (308 nm) was used for ablating the samples and ITMS was used as a detector. Samples were introduced from outside of a ring electrode and this way of sample introduction was very effective for solid samples when laser ablation was employed. Helium gas was used as a buffer gas, and its effect on sensitivity and some parameters (buffer gas pressure, ion storage time, and cut-off RF voltage) were studied. The optimized conditions were $1{\times}10^{-4}$ Torr of buffer gas pressure, 100 ms of ion storage time and $1150V_{p-p}$ of cut-off RF voltage. From that results, copper (Cu) and molybdenum (Mo) metals were tested with LAITMS and the mass spectra of these pure metals were compared with the natural abundance of isotope ratio. We also examined ceramic samples ($Al_2O_3$, $ZrO_2$) and represented the result of elemental analysis.

A Study on the Analysis of Methylprednisolone Acetate and its Metabolites in Rat Urine by LC/MS (LC/MS를 이용한 뇨중에서의 Methylprednisolone Acetate 및 그 대사물질 분석에 관한 연구)

  • Park, Song-Ja;Pyo, Hee Soo;Kim, Yun Je;Park, Seong Soo;Park, Jongsei
    • Analytical Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.139-159
    • /
    • 1995
  • Positive ion mass spectra of some corticosteroids were obtained by using liquid chromatography-mass spectrometry(LC-MS). The base peak of each compound showed the protonated molecular ion [$MH^+$], ammonium adduct ion [${MNH_4}^+$] or [$MH^+-60$] ion according to its chemical structure and other characteristic mass ions were [$MH^+-18$], [${MNH_4}^+-18$] and so on. Several rat urinary metabolites of methylprednisolone acetate after the oral administration were detected by the thermospray LC-MS. The identified major metabolites were 20-hydroxymethylprednisolone(20-HMP), methylprednisolone(MP) and methylprednisone(11-KMP), which were supposed to be formed by deacetylation at the position of C-21, reduction at C-20, oxidation at C-11, or due to the bond cleavage between C-17 and C-20.

  • PDF

A New Analytical Method for the $Tb^{+3}$ and $Eu^{+3}$ Ions Using the Fluorescence Enhancement on the TLC Plate (TLC상에서의 형광증폭을 이용한 $Tb^{+3}$$Eu^{+3}$ 이온의 미량분석에 관한 연구)

  • Jeong, Hyuk;Lee, Gee-Yeoun;An, Seong-Hee;Kim, Hai-Dong;Lee, Won;Shin, Dae-Ho
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.1
    • /
    • pp.40-46
    • /
    • 1995
  • A new analytical luminescence method for the Tb+3 and Eu+3 ions was studied using the fluorescence enhancement of the ions on the TLC plate. Compared to the specific emission intensities of the ions in aqueous or ethanol solution, if spotted on the TLC plate, the line intensities were extremely enhanced. There was additional enhancement effect of the lines from the ions on the TLC plate, if treated with ο-phenanthroline. Based on the luminescence enhancement, the detection limit of the ions was lowered more than 6 order of magnitude compared to the luminescence method using solution samples. The energy-transfer mechanism was also explained for the theoretical back ground of the luminescence enhancement.

  • PDF

Survey of Contaminants of 3-MCPD and 1,3-DCP in Soy Sauce Using GC/MSD (GC/MSD를 이용한 간장 중 3-MCPD와 1,3-DCP의 오염도 조사)

  • Kim Myung-Gill;Kim Young-Sug;Lee Myung-Jin;Kim Jae-Kwan;Kim Kyung-A;Park Eun-Mi;Ko Hoan-Uck;Son Jin-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.3
    • /
    • pp.153-158
    • /
    • 2006
  • The contamination levels of 3-MCPD(3-Monochloropropane-1,2-diol) and 1,3-DCP(1,3-Dichloro-2-Propanol) in soy sauce, sauces was monitored. 105 samples were collected from June 2005 to August 2005 in Gyeonggi-do. 3-MCPD and 1,3-DCP were analyzed by GCMSD. As results, the detection range of 3-MCPD concentration was between 0.02 mg/kg and 0.27 mg/kg in soy sauce. However any samples were not detected with 1,3-DCP. The contaminated rates of 3-MCPD in soy sauce was 17.1%. Soy sauce is the representative vegetable protein hydrolyzed food. The reliable analytical method f3r the toxic 3-MCPD and 1,3-DCP in Soy sauce has been studied. The derivatization studies of 3-MCPD and 1,3-DCP were performed mainly as Silylation with BSA(N,O-Bis(trimethylsilyl)-acetamide). The retention times of derivative, BSA-MCPD, BSA-DCP were 11.30 and 10.12 minutes.

Relationship between Microflora and Environmental Factors in Groundwater (지하수 미생물과 환경요인의 상호관계)

  • 안연준;민병례;최영길
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 1995
  • This study was conducted to find out the relationship between microflora in groundwater and its physico-chemical environmental factors at the 59 sites, where distributed at 3 cities and 18 counties in Jeonranam-Do, Korea. The average values of environmental factors were as followings; pH 6.9, temperature 20.1 $^{\circ}C$, dissolved oxygen 6.5 mg/1, the depth of wells 80.1 m, and nitrate 10.7 mg/1. The average value of microbial population size; Heterotrophic bacteria-NA (HPC-NA) and heterotrophic bacteria-YEPD (HPC-YEPD) were 1.4${\times}$10$^3$CFU/ml and 0.59${\times}$10$^3$ CFU/ml respectively HPC-YEPD numbers were 42.1% of HPC-YEPD. Coliform bacteria were detected at 16 sites, and its average numbers were 6.7 CFU/ml. General fungi were detected at 14 sites, and its had average numbers were 3.9 CFU/ml. The correlation coefficient was calculated value as relation index between the microbial population sizes and environmental factors in groundwater. In case of HPC-NA, the correlation coefficient value with dissolved oxygen was 0.087 But it showed negative correlation coefficient with other factors. In case of HPC-YEPD, the correlation coefficient value with pH, temperature and nitrate were 0.0957, 0.0019 and 0.0151 respectively. It was concluded that the population size of HPC-NA were influenced by the order of temperature, dissolved oxygen, pH and the depth of wells and that HPC-YEPD were influenced by the order of pH, dissolved oxygen, nitrate, the depth of wells and temperature.

  • PDF

Effect of Redox Processes and Solubility Equilibria on the Behavior of Dissolved Iron and Manganese in Groundwater from a Riverine Alluvial Aquifer (만경강 하천변 충적 지하수의 용존 Fe와 Mn 거동에 대한 산화-환원 과정과 용해 평형의 효과)

  • Choi, Beom-Kyu;Koh, Dong-Chan;Ha, Kyoo-Chul;Cheon, Su-Hyun
    • Economic and Environmental Geology
    • /
    • v.40 no.1 s.182
    • /
    • pp.29-45
    • /
    • 2007
  • Biogeochemical characteristics involving redox processes in groundwater from a riverine alluvial aquifer was investigated using multi-level monitoring wells (up to 30m in depth). Anaerobic conditions were predominant and high Fe ($14{\sim}37mg/L$) and Mn ($1{\sim}4mg/L$) concentrations were observed at 10 to 20 m in depth. Below 20 m depth, dissolved sulfide was detected. Presumably, these high Fe and Mn concentrations were derived from the reduction of Fe- and Mn-oxides because dissolved oxygen and nitrate were nearly absent and Fe and Mn contents were considerable in the sediments. The depth range of high Mn concentration is wider than that of high Fe concentration. Dissolved organics may be derived from the upper layers. Sulfate reduction is more active than Fe and Mn reduction below 20 m in depth. Disparity of calculated redox potential from the various redox couples indicates that redox states are in disequilibrium condition in groundwater. Carbonate minerals such as siderite and rhodochrosite may control the dissolved concentrations of Fe(II) and Mn(II), and iron sulfide minerals control for Fe(II) where sulfide is detected because these minerals are near saturation from the calculation of solubility equilibria.

Effect of ion Chip and Yellow Soil on Growth and Physicochemical Characteristics of Soybean Sprouts (Ion Chip과 황토 처리가 콩나물의 생육 및 물리화학적 특성에 미치는 영향)

  • Kim In-Suk;Choi Sun-Young;Chung Mi-Ja;Kim Tae-Hoon;Sung Nak-Ju
    • The Korean Journal of Food And Nutrition
    • /
    • v.18 no.4
    • /
    • pp.316-324
    • /
    • 2005
  • The objectives of this study were to examine effect of ion chip and yellow soil on the growth and physicochemical characteristics of soybean sprouts. The weight and length increased rapidly in soybean sprouts cultivated for 4 days and then the increases slowed. Ascorbic acid increased rapidly after day 6 in soybean sprouts cultivated with ionized water (I.W), $1.0\%$ yellow soil in tap water (T.W+l.0) and $1.0\%$ yellow soil in ionized water (I.W+l.0). The detected content of minerals such as Mg, Ca, K and Fe in soybean sprouts was higher than other minerals. Iron content was the highest in soybean sprouts cultivated by I.W+1.0. The detected levels of glutamic acid in soybean sprouts cultivated for 4 days with ionized water was higher than in those grown with tap water. In all soybean sprouts, nucleotides such as UMP, CMP, AMP, Hx and soluble free sugars like sucrose, raffinose, stachylose were detected, and the levels of UMP were found to be the highest among nucleotides and sucrose among free sugars.

Effects of Divalent Cations on the Self-splicing Inhibition of Group I Intron by the Coen-zyme Thiamine Pyrophosphate (2가 양이온이 Thiamine Pyrophosphate에 의한 Group I Intron Ribozyme의 Splicing 억제에 미치는 영향)

  • 안성준;박인국
    • Korean Journal of Microbiology
    • /
    • v.38 no.1
    • /
    • pp.13-18
    • /
    • 2002
  • Effects of divalent cations such as $Mg^{2+}$, $Mn^{2+}$ and $Zn^{2+}$ on the self-splicing inhibition of the T4 phage thymidylate synthase (td) intron by the coenzyme thiamine pyrophosphate have been investigated. The splicing activity increased in proportion to the concentration of $Mg^{2+}$ up to 30 mM. Without $Mg^{2+}$in the splicing reaction the $Zn^{2+}$ ion tested in the range of 0.1-6 mM concentration only produced the splicing activity about 20% that of the normal splicing rate. A majority of the splicing products were I-E2 and E2 but El-E2 ligation product, Cl and Ll were not detected. Similar patterns of splicing products were also observed with $Mn^{2+}$. At 6 mM $Zn^{2+}$the intron RNA was hydrolyzed. $Mn^{2+}$produced a little higher splicing activity than that of $Zn^{2+}$over the range of concentrations used and at 8 mM about 28% splicing activity was observed. In contrast, $Mn^{2+}\;and\;Zn^{2+}$ ions promoted the splicing activity about 35-40% on an average in the presence of 10 mM $Mg^{2+}$. Of all divalent cations tested, $Mg^{2+}$exhibited the maximum activation effect to counteract the splicing inhibition by thiamine pyrophosphate. This appears to be due to the stabilizing effect of td intron ribozyme structure essential for the catalytic function by $Mg^{2+}$.

Analysis of Sildenafil and its Analogues by LC/MS/MS (LC/MS/MS를 이용한 sildenafil 및 그 유사체 분석)

  • Myung, Seung-Woon;Park, So-Hee;Cho, Hyun-Woo
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.488-498
    • /
    • 2003
  • By LC/MS/MS, the analytical method of sildenafil and its analogues (homosildenafil, vardenafil and tadalafil) used as used medical treatment of impotence was established. electrosprary ionization (ESI) and atmospheric pressure chemical ionization (APCI) as a ionization method were applied. Several parameter were varied and the sensitivity and reproducibility were compared. In LC/ESI-MS method, capillary voltage, cone voltage, extractor, entrance and RF lens to create appropriate productr ions for multiple reaction monitoring (MRM) were variable parameter, but the formation of the other product ions except the precursor ion could not detect. And the value of entrance, collision energy, exit, corona voltage, cone voltage, extractor, RF lens, cone gas, and desolvation gas in APCI mode were varied, only the creation pattern of fragment ions by the change of RF lens value were detected, and the limit of detection was decreased due to the increase of S/N. Ten millimole ammonium formate (pH 4.8):acetonitrile=70:30 by isocratic elution in HPLC system was shown the maximum sensitivity in MS, the detection limit of sildenafil, homosildenafil, vardenafil and tadalafil obtained by ESI-MRM were 0.10, 0.025, 0.025, and $0.25{\mu}g/mL$ at S/N>5, respectively.