• Title/Summary/Keyword: 이성분계 혼합물

Search Result 57, Processing Time 0.038 seconds

A Comparative Study on the Prediction of Vapor-Liquid Equilibria for the Ethanol-Benzene Mixture between Equation of State Model and Liquid Activity Coefficient Model (비이상적 상거동을 보이는 이성분계 혼합물의 기액 상평형 추산을 위한 상태방정식과 액체 활동도계수 모델 사이의 비교연구)

  • Cho, Jung-Ho;Lee, Ji-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.5
    • /
    • pp.1747-1753
    • /
    • 2010
  • In this study, a comparative study was performed to predict the vapor-liquid equilibria with maximum azeotropic pressure for ethanol-benzene binary system between an equation of state model and a liquid activity coefficient model. Peng-Robinson equation of state model with a Panatiotopoulos mixing rules (PRP) was used and NRTL liquid activity coefficient model proposed by Renon was selected. The PRP model, even though it has only two binary adjustable parameters, was not inferior to the NRTL model to predict vapor-liquid equilibria for low pressure region of ethanol-benzene system and showed a better prediction capability for high pressure region of ethanol-benzene system than the NRTL model with three binary interaction parameters.

Separation of Trichlorinated Hydrocarbons by ZSM-5 Zeolite Membrane (ZSM-5 제올라이트 분리막에 의한 3가 염소화합물의 투과증발 분리)

  • Lee Yong-Taek;Sim Eun-Young;Ahn Hyo-Seong
    • Membrane Journal
    • /
    • v.16 no.2
    • /
    • pp.159-166
    • /
    • 2006
  • MFI(Mobil Five) structured hydrophobic ZSM-5 zeolite membrane was used for selective pervaporation of trichlorinated organic compounds(trichloromethane, trichloroethane, trichloroethylene) from their aqueous solutions. ZSM-5 zeolite membrane was hydrothermally synthesized on the inside of a porous stainless steel tube by secondary growth employing ZSM-5 seed powders. Separation factors for each binary mixtures were observed $16{\sim}66$ for trichloromethane/water, $3.3{\sim}4.6$ for trichloroethane/water and $1.4{\sim}8$ for trichloroethylene/water at the experimental conditions of the feed mole fraction from 0.0001 to 0.001 with temperature ranged $25{\sim}35^{\circ}C$.

A Study on the Pressure-Swing Distillation of Ethanol-n-Heptane Azeotrope (에탄올-n-헵탄 공비 혼합물의 분리를 위한 압력변환 증류공정 연구)

  • Noh, Sang Gyun
    • Clean Technology
    • /
    • v.21 no.4
    • /
    • pp.217-223
    • /
    • 2015
  • In the present study, modelling and optimization of ethanol-n-heptane separation process were performed using pressure-swing distillation. The pressure-swing distillation process optimization was performed to obtain high purity ethanol and high purity n-heptane into a low-high pressure columns configuration and a high-low pressure columns configuration. The results of pressure-swing distillation process simulation and optimization using high-low pressure column configuration showed a reduced total reboiler heat duty at 5.8% which confirmed a more economical energy consumption.

Measurement of Flash Point for Binary Mixtures of 2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane, and Toluene at 101.3 kPa (2-Butanol, 2,2,4-Trimethylpentane, Methylcyclohexane 그리고 Toluene 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정)

  • Hwang, In Chan;In, Se Jin
    • Clean Technology
    • /
    • v.26 no.3
    • /
    • pp.161-167
    • /
    • 2020
  • For the design of the prevention and mitigation measures in process industries involving flammable substances, reliable safety data are required. An important property used to estimate the risk of fire and explosion for a flammable liquid is the flash point. Flammability is an important factor to consider when developing safe methods for storing and handling solids and liquids. In this study, the flash point data were measured for the binary systems {2-butanol + 2,2,4-trimethylpentane}, {2-butanol + methylcyclohexane} and {2-butanol + toluene} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a Stanhope-Seta closed cup flash point tester. A minimum flash point behavior was observed in the binary systems as in the many cases for the hydrocarbon and alcohol mixture that were observed. The measured flash points were compared with the predicted values calculated via the following activity coefficient (GE) models: Wilson, Non-Random Two-Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC) models. The predicted data were only adequate for the data determined by the closed-cup test method and may not be appropriate for the data obtained from the open-cup test method because of its deviation from the vapor liquid equilibrium. The predicted results of this work can be used to design safe petrochemical processes, such as the identification of safe storage conditions for non-ideal solutions containing flammable components.

Separation of Isomers and Close Boiling Mixtures by Crystalline Thiourea (결정성 Thiourea에 의한 유기 이성체 및 유사비점 혼합물의 분리)

  • Kim, Kwang-Joo;Lee, Choul-Ho;Lee, Jung-Min
    • Applied Chemistry for Engineering
    • /
    • v.7 no.1
    • /
    • pp.129-135
    • /
    • 1996
  • The entrapping capacity of the single hydrocarbons and the entrapping equilibrium data for binary mixtures of the $C_6$ to $C_9$ hydrocarbons on the activated thiourea have been investigated. The entrapping capacity of single component varied irregularly with molecular size and was independent of temperature. In the liquid phase entrapping from binary system, the lower molecular weight hydrocarbon was entrappe preferentially. In the liquid phase entrapping from trimethylbenzene isomer and ethyltoluene isomer, selectivity was found to be related to the relative position of methyl groups in the molecules and hence the electronic configuration. Pseudocumene of a purity of 99.5wt% may be obtained from $C_9$ aromatic raffinate found in naphtha cracking center. Activated thiourea was more efficient than distillation, extractive crystallization and adductive crystallization in terms of separation factor.

  • PDF

Estimation of the Flash Points for n-Propanol+Formic acid System Using the Binary Parameters Optimization Method (이성분계 파라미터 최적화 기법을 활용한 n-Propanol+Formic acid 계의 인화점 추산)

  • Ha, Dong-Myeong;Lee, Sung-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.65-69
    • /
    • 2008
  • An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the n-propanol+formic acid system were measured by Pensky-Martens closed cup apparatus. This binary mixture exhibited MFPB (minimum flash point behavior), which leads to the minimum on the flash point vs composition curve. The Raoult's law and optimization method using Wilson equation were used to predict the lower flash points and were compared with experimental data. The calculated values based on the optimization method were found to be better than those based on the Raoult's law.

Measurement and Prediction of Flash Points of Acetic Acid-Formic Acid System using Cleveland Open Cup Apparatus (Cleveland 개방식 장치를 이용한 Acetic acid+Formic acid 계의 인화점 측정과 예측)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.6
    • /
    • pp.67-72
    • /
    • 2013
  • The flash point is the lowest temperature at which there is enough concentration of flammable vapor to form an ignitable mixture with air. The flash point is a major physical property used to analyse the fire and explosion hazards of a flammable liquid solution. The flash point data for pure components are easily available in several literature. But the flash points of the flammable binary solutions appear to be scarce in the literature. The objective of this study is to measure and estimate the flash point of acetic acid-formic acid system. Cleveland open cup tester was used to measure the flash point. The experimental data were compared with the values estimated by the Raoult's law and the optimization methods based on van Laar and Wilson equations. As a result, the estmated values by optimization methods were found to be better than those based on the Raoult's law.

The Measurement and Prediction of Flash Point for Binary Mixtures of Methanol, Ethanol, 2-Propanol and 1-Butanol at 101.3 kPa (Methanol, Ethanol, 2-Propanol 그리고 1-Butanol 이성분 혼합계에 대한 101.3 kPa에서의 인화점 측정 및 예측)

  • Oh, In Seok;In, Se Jin
    • Fire Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.1-6
    • /
    • 2015
  • Flash point is one of the most important variables used to characterize fire and explosion hazard of liquids. The lower flash point data were measured for the binary systems {methanol + 1-butanol}, {ethanol + 1-butanol} and {2-propanol + 1-butanol} at 101.3 kPa. Experiments were performed according to the standard test method (ASTM D 3278) using a SETA closed cup flash point tester. The measured flash points were compared with the predicted values calculated using the following activity coefficient models: Wilson, Non-Random Two Liquid (NRTL), and UNIversal QUAsiChemical (UNIQUAC). The measured FP data agreed well with the predicted values of Raoult's law, Wilson, NRTL and UNIQUAC models. The average absolute deviation between the predicted and measured lower FP was less than 1.14 K.