• Title/Summary/Keyword: 이상전원

Search Result 728, Processing Time 0.032 seconds

A Microcomputer-Based Data Acquisition System (Microcomputer를 이용(利用)한 Data Acquisition System에 관(關)한 연구(硏究))

  • Kim, Ki Dae;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.7 no.2
    • /
    • pp.18-29
    • /
    • 1983
  • A low cost and versatile data acquisition system for the field and laboratory use was developed by using a single board microcomputer. Data acquisition system based on a Z80 microprocessor was built, tested and modified to obtain the present functional system. The microcomputer developed consists of 6 kB ROM, 5 kB RAM, 6-seven segment LED display, 16-Hex. key and 8 command key board. And it interfaces with an 8 channel, 12 bits A/D converter, a microprinter, EPROM programmer for 2716, and RS232C interface to transfer data between the system and HP3000 mini-computer manufactured by Hewlett Packard Co., A software package was also developed, tested, and modified for the system. This package included drivers for the AID converter, LED display, key board, microprinter, EPROM programmer, and RS232c interface. All of these programs were written in 280 assembler language and converted to machine codes using a cross assembler by HP3000 computer to the system during modifying stage by data transferring unit of this system, then the machine language wrote to the EPROM by this EPROM programmer. The results are summarized as follows: 1. Measuring program developed was able to control the measuring intervals, No. of channels used, and No. of data, where the maximum measuring speed was 58.8 microsec. 2. Calibration of the system was performed with triangle wave generated by a function generator. The results of calibration agreed well to the test results. 3. The measured data was able to be written into EPROM, then the EPROM data was compared with original data. It took only 75 sec. for the developed program to write the data of 2 kB the EPROM. 4. For the slow speed measurements, microprinter instead of EPROM programmer proved to be useful. It took about 15 min. for microprinter to write the data of 2 kB. 5. Modified data transferring unit was very effective in communicating between the system and HP3000 computer. The required time for data transferring was only 1~2 min. 6. By using DC/DC converting devices such as 78-series, 79-series. and TL497 IC, this system was modified to convert the only one input power sources to the various powers. The available power sources of the system was DC 7~25 V and 1.8 A.

  • PDF

A 0.31pJ/conv-step 13b 100MS/s 0.13um CMOS ADC for 3G Communication Systems (3G 통신 시스템 응용을 위한 0.31pJ/conv-step의 13비트 100MS/s 0.13um CMOS A/D 변환기)

  • Lee, Dong-Suk;Lee, Myung-Hwan;Kwon, Yi-Gi;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.75-85
    • /
    • 2009
  • This work proposes a 13b 100MS/s 0.13um CMOS ADC for 3G communication systems such as two-carrier W-CDMA applications simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs a four-step pipeline architecture to optimize power consumption and chip area at the target resolution and sampling rate. Area-efficient high-speed high-resolution gate-bootstrapping circuits are implemented at the sampling switches of the input SHA to maintain signal linearity over the Nyquist rate even at a 1.0V supply operation. The cascode compensation technique on a low-impedance path implemented in the two-stage amplifiers of the SHA and MDAC simultaneously achieves the required operation speed and phase margin with more reduced power consumption than the Miller compensation technique. Low-glitch dynamic latches in sub-ranging flash ADCs reduce kickback-noise referred to the differential input stage of the comparator by isolating the input stage from output nodes to improve system accuracy. The proposed low-noise current and voltage references based on triple negative T.C. circuits are employed on chip with optional off-chip reference voltages. The prototype ADC in a 0.13um 1P8M CMOS technology demonstrates the measured DNL and INL within 0.70LSB and 1.79LSB, respectively. The ADC shows a maximum SNDR of 64.5dB and a maximum SFDR of 78.0dB at 100MS/s, respectively. The ABC with an active die area of $1.22mm^2$ consumes 42.0mW at 100MS/s and a 1.2V supply, corresponding to a FOM of 0.31pJ/conv-step.

An historical analysis on the carbon lock-in of Korean electricity industry (한국 전력산업의 탄소고착에 대한 역사적 분석)

  • Chae, Yeoungjin;Roh, Keonki;Park, Jung-Gu
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.125-148
    • /
    • 2014
  • This paper performs a historical analysis on the various factors contributing to the current carbon lock-in of Korean electricity industry by using techo-institutional complex. The possibilities of the industry's carbon lock-out toward more sustainable development are also investigated. It turns out that market, firm, consumer, and government factors are all responsible for the development of the carbon lock-in of Korean power industry; the Korean government consistently favoring large power plants based on the economy of scale; below-cost electricity tariff; inflation policy to suppress increases in power price; rapid demand growth in summer and winter seasons; rigidities of electricity tariff; and expansion of gas-fired and imported coal-fired large power plants. On the other hand, except for nuclear power generation and smart grid, environment laws and new and renewable energy laws are the other remaining factors contributing to the carbon lock-out. Considering three key points that Korea is an export-oriented economy, the generation mix is the most critical factor to decide the amounts of carbon emission in the power industry, and the share of industry and commercial power consumption is over 85%, it is unlikely that Korea will achieve the carbon lock-out of power industry in the near future. Therefore, there are needs for more integrated approaches from market, firm, consumer, and government all together in order to achieve the carbon lock-out in the electricity industry. Firstly, from the market perspective, it is necessary to persue more active new and renewable energy penetration and to guarantee consumer choices by mitigating the incumbent's monopoly power as in the OECD countries. Secondly, from the firm perspective, the promotion of distributed energy system is urgent, which includes new and renewable resources and demand resources. Thirdly, from the consumer perspective, more green choices in the power tariff and customer awareness on the carbon lock-out are needed. Lastly, the government shall urgently improve power planning frameworks to include the various externalities that were not properly reflected in the past such as environmental and social conflict costs.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.

Recycling Bone Autotransplantation with Extracorporeal Heat-Treatment for Malignant Bone Tumors of Pelvis (골반골의 악성 골종양의 재건술에서 체외 열처리를 이용한 재활용 자가골 이식술 및 인공 관절 치환술을 시행한 3례 보고)

  • Kim, Sae-Hoon;Lee, Sang-Hoon;Cho, Hwan-Sung;Kim, Han-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.9 no.1
    • /
    • pp.115-123
    • /
    • 2003
  • Study Design: A retrospective clinical and radiographic review. Objectives: The purpose of this study was to suggest recycling bone autotransplantation with extracorporeal heat-treatment as one of favorable reconstruction method for malignant bone tumors of pelvis through 3 cases. Summary of Literature Review: There are many biologic and nonbiologic reconstruction method in pelvic reconstruction. Cases: Case 1- A 20-year-old women had chief complaint of right hip and thigh pain started 3 months ago and done curettage and bone cementing at right ilium at other hospital. She had impression of malignant bone tumor and undergone postoperative radiation therapy for 6 cycles. After that she was referred to our hospital and undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal heat-treatment at 132 degree celsius for 2 minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed well-differentiated osteosarcoma on postoperative pathology. Neither adjuvant nor neoadjuvant chemotherapy were done. Case 2- A 56-year-old women who suffered right thigh pain for 3 months was detected radiologic abnormality at right pelvis. After incisional biopsy, osteosarcoma was diagnosed. We had undergone wide excision of right ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (ABG$^{(R)}$). There was no evidence of distant metastasis and revealed high-grade osteosacoma which was fibroblastic type on postoperative pathology. Adjuvant chemotherapy (HDMTX, ADR, CDDP) was done immediate after wound healing was completed. Case 3- A 46-year-old women was incidently found mass at left ilium which was suspected chondrosarcoma. We had undergone wide excision of left ilium and recycling bone autotransplantation with extracorporeal low heat-treatment at 65 degree celsius for 30minutes internal fixation with pelvic reconstruction plate and total hip replacement arthroplasty (Protek$^{(R)}$). There was no evidence of distant metastasis and revealed chondrosarcoma which was graded II/III on postoperative pathology. Results: Oncologic and functional outcome at final follow-up were for case 1, final follow-up time was 7 years, is no evidence of disease and functional score is 53% according to Ennecking et al. During follow-up, evidence of radiologic union was at about 1 and 6 months after operation. The case had breakage of pelvic reconstruction plate and some resorption of autotransplated bone, but no symptom present. For case 2, final follow-up was 3 years and 6 months, is no evidence of disease and functional score is 60%. For case 3, final follow-up was 7 months, no evidence of disease and functional score is 63% which is improving state. Discussion: 3 cases which were undergone recycling bone autotransplantation with extracorporeal heat-treatment and total hip replacement arthroplasty had relatively successful oncologic and functional outcome. Taking account that difficulty in using allograft in Korea this method is thoght to be one of the useful way to reconstruct pelvis after resection of primary malignant bone tumor of the pelvis.

  • PDF

Praziquantel($Distocide^{\circledR}$) in Treatment of Clonorchis sinensis Infection (국산 Praziquantel($디스토시드^{\circledR}$)의 간흡충증에 대한 효과)

  • 서병고;이순형금종일홍성태
    • Parasites, Hosts and Diseases
    • /
    • v.21 no.2
    • /
    • pp.241-245
    • /
    • 1983
  • PraziquantEI ($Distocide^{\circledR}$), the KcrEan product, was tEstEd for its safety and Efficacy in treatmEnt of Clonorchis sinensiJ infccticn during the period from April to SeptembEr, 1983 in Korea. A total of 55 egg positive cases were selected and treated with the regimen of 25 mg/kg t.i.d. for 1 day (total 75 mg/kg). The follow-up stool examination was done in 47 cases by cellophane thir;k smear and Stoll's egg counting techniques. The 8 uncured cases were treated again with the same regimen. The laboratory tests for blood picture and liver function were done in 27 cases and compared before and after the treatment. The results obtainEd are as follows: 1. After single course treatment, the cure and egg reduction rates were 83.0 and 99.1% respectively. With the second treatment, excellent results of 100% in both rates were obtained. 2. Several kinds of side effects such as dizziness, headache, etc. were complained by 29 cases (61.7 %), however, those were so mild and transient that no special treatment was necessary. 3. No significant change in laboratory findings was recognizable before and after the treatment. From the above results, it is concluded that $Distocide^{\circledR}$ is as effective and safe as $Biltricide^{\circledR}$ and highly recommendable in treatment of C. sinensis infection.

  • PDF

Risk Factors for the Early Recognition of Cow's Milk Protein-induced Enterocolitis (우유 단백질 유발성 장염의 조기진단을 위한 위험인자)

  • Lee, Sung Hyuk;Choi, Seon Yun;Lee, Byung Cheol;Choi, Won Joung;Choe, Byung Kyu;Kim, Yeo Hyang;Kang, Una;Kam, Sin;Hwang, Jin-Bok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.991-997
    • /
    • 2005
  • Purpose : Cow's milk protein-induced enterocolitis(CMPIE) is a symptom complex of vomiting and/or diarrhea caused by delayed hypersensitivity and may result in serious complications. This study was undertaken to identify high risk factors to facilitate the early recognition of CMPIE. Methods : We reviewed the data of 101 patients, aged 15 to 45 days, admitted due to vomiting and/or diarrhea between 2003 and 2004. After excluding 13 patients absolutely breast-fed and 2 patients transferred from other hospitals with the impression of CMPIE, the 86 study subjects were divided into three groups based on the underlying etiologies; CMPIE, infectious and non-infectious group. Results : CMPIE was diagnosed in 11 patients(12.8%). On admission, failure to gain weight(P=0.003), hypoalbuminemia(P=0.003), peripheral leukocytosis(P=0.015), and metabolic acidosis(P=0.014) were more significant in the CMPIE group than in the others. Multiple logistic regression analysis showed that the independent predictors of high risks for CMPIE were failure to gain weight <10 g/day(OR, 10.25[95% CI, 1.62-65.06]) and serum hypoalbuminemia <3.5 g/dL(OR, 9.18[95% CI, 1.69-49.74]). Cow's milk challenges were performed in the 11 CMPIE patients; vomiting(81.8%), abnormal stool test(80.0%), peripheral leukocyte count and absolute neutrophil count(ANC) increase(100.0%) (P<0.05), and enteropathy(100.0%). Conclusion : CMPIE is not a rare clinical disease in early infancy. The high risk factors of CMPIE were identified as follow : failure to gain weight below 10 g/day, hypoalbuminemia on admission and a rapid decrease during admission. Cow's milk challenge test with endoscopic duodenal biopsy was helpful to confirm CMPIE.

Comparison of Rehospitalization during the First Year of Life in Normal and Low Birth Weight Infants Discharged from NICU (신생아 집중치료실에서 퇴원한 정상 체중아와 저출생 체중아의 재입원에 관한 비교)

  • Min, Sae Ah;Jeon, Myung Won;Yu, Sun Hee;Lee, Oh Kyung
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1503-1511
    • /
    • 2002
  • Purpose : Although the short- and long-term outcomes of low birth weight(LBW) neonatal intensive care unit(NICU) survivors have been extensively studied, much less information is available for normal birth weight(NBW) infants(greater than 2,500 gm) who require NICU care. Methods : We retrospectively examined the neonatal hospitalizations and one year health status of 302 NBW and 131 LBW admissions to our NICU. Information on the neonatal hospitalization was obtained from a review of medical records. Postdischarge health status was collected by using telephone surveys and medical records. Results : After initial discharge, 21.2% of the NBW infants and 23% of the LBW infants required rehospitalization during the first year of life and there was no significant difference between the two groups. The reasons for rehospitalization of the NBW infants included respiratory disorders (32.1%), G-I problems(26.2%), genitourinary problems(11.9%), surgery(10.7%), cardiac problems(7.1%), and congenital/developmental problems(1.2%). For the LBW infants, the order of frequency was the same, with the percentages slightly different. Neonatal risk factors related to the rehospitalization of the NBW infants included mechanical ventilation, duration of mechanical ventilation, and congenital anomaly. But no positive significant correlation of neonatal risk factors with rehospitalization of LBW infants was found. Conclusion : Low and normal birthweight NICU survivors were rehospitalized at similar rates. The most common cause of rehospitalization was respiratory problems. Neonatal risk factors related to rehospitalization of NBW infants were mechanical ventilation, duration of mechanical ventilation, and congenital anomaly. However, no positive significant correlation of neonatal risk factors with rehospitalization of LBW infants was found. The data suggests that NBW infant survivors, as well as LBW infant NICU survivors, require close follow up.

Topographical Chemical Properties of Paddy Soils in Gyeongnam Province (경남지역 논토양 지형과 화학성의 관계)

  • Lee, Young-Han;Sonn, Yeon-Kyu;Lee, Seong-Tae;Heo, Jae-Young;Kim, Min-Keun;Kim, Eon-Seok;Song, Won-Doo;Zhang, Yong-Sun;Jeon, Weon-Tai;Ok, Yong-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.143-148
    • /
    • 2012
  • Sustainable agriculture requires reliable information on the spatial distribution of the soil chemical properties for effective management of paddy fields. In order to provide adequate soil nutritional information for environmental-friendly agriculture, we investigated the soil chemical properties for 260 paddy soils sampled in Gyeongnam Province from 1999 to 2011 by four years of interval. Soil chemical properties of pH, organic matter, available phosphate and silicate, exchangeable potassium, calcium, and magnesium contents were analyzed. The pH value, organic matter, available phosphate and silicate, and exchangeable calcium and magnesium in paddy soils were significantly elevated in 2011 compared to 1999. The excessive levels of organic matter and available phosphate in paddy soils were detected in 2011. The soil available phosphate was highest in mountain foot-slope (p<0.05) and the soil organic matter was highest in diluvial terrace (p<0.05). It revealed that the soil available phosphate was the responsible factor for the differentiation of soil chemical properties by the topography in paddy soils.

Effect of Liquid Pig Manure Application on Soil Chemical Properties in Rice-Chinese Milkvetch Crop Rotation (벼-자운영 윤작재배에서 돈분액비 시용이 토양화학성에 미치는 영향)

  • Kang, Se-Won;Seo, Dong-Cheol;Seo, Young-Jin;Lee, Sang-Gyu;Choi, Ik-Won;Jeon, Weon-Tai;Kang, Ui-Gum;Sohn, Bo-Kyoon;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • This study was conducted to investigate the effect of liquid pig manure application on soil chemical properties in rice - Chinese milkvetch rotation. Field experiment was designed with APLM 0 (Chinese milkvetch + Liquid pig manure $0L\;m^{-2}$), APLM 50 (Chinese milkvetch + Liquid pig manure $1.8L\;m^{-2}$), APLM 75 (Chinese milkvetch + Liquid pig manure $2.7L\;m^{-2}$) and APLM 100 (Chinese milkvetch + Liquid pig manure $3.6L\;m^{-2}$), respectively. The concentration of O.M, T-N, Avail. $P_2O_5$, K, Ca and Mg at different liquid pig manure levels in soil were generally high in the order of APLM 100 > APLM 75 > APLM 50 > APLM 0. Especially, T-N concentration of soil in APLM 100 was 1.4 times higher than APLM 0. The yield of rice in APLM 100 was $636kg\;10a^{-1}$ (increasing yield 5.3%) compared with APLM 0 in rice-Chinese milkvetch crop rotation. Therefore, application of liquid pig manure was useful in rice - Chinese milkvetch crop rotation.