• Title/Summary/Keyword: 이산화탄소 레이저

Search Result 32, Processing Time 0.025 seconds

Surface transform of $Si_3N_4$ ceramics irradiated by $CO_2$ laser beam ($CO_2$ 레이저 빔에 의한 $Si_3N_4$ 세라믹의 반응연구)

  • Kim, Seon-Won;Lee, Je-Hun;Seo, Jeong;Jo, Hae-Yong;Kim, Gwan-U
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.06a
    • /
    • pp.16-24
    • /
    • 2006
  • Silicon Nitride ($Si_3N_4$), which is widely used in a variety of applications, is hard-to-machine due to its high hardness. At high temperature (e.g. above $1000^{\circ}C$), however, the machinability can be greatly improved. In this work, we used a $CO_2$ laser with a high absorptivity to $Si_3N_4$ of 0.9 to locally heat the surface of a rotating $Si_3N_4$ rod on a lathe. In order to examine the effects of the laser-assisted heating on hardness, an $Si_3N_4$ md is heated to temperatures from 900 to $1800^{\circ}C$ and is rotated at speeds from 440-900 rpm in experiments. When the rod is naturally cooled to room temperature, we measured the Victors hardness (Hv): and observed the surface of HAZ using a scanning electron microscopy (SEM). Energy dispersive spectroscopy(EDS) was used for ingredient analysis. Results showed that when heated at $1600^{\circ}C$, the hardness of $Si_3N_4$ decreased from 1500 Hv to 1000 Hv. Also, in order to predict the depth of HAZ, we numerically analyzed the laser-assisted heating of $Si_3N_4$.

  • PDF

Experimental Study on the Secondary Flow Characteristics of a Supercritical Carbon Dioxide Flow in a Gas Cooling Process Within a Square Duct (정사각 덕트 초임계 상태 이산화탄소 가스 냉각과정 중 2차 유동 특성 측정 연구)

  • Han, Seong-Ho;Seo, Jung-Sik;Kim, Young-Chan;Kim, Min-Soo;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.2
    • /
    • pp.158-165
    • /
    • 2008
  • The carbon dioxide properties change sharply near the critical or pseudo-critical point in the heat transfer processes. The reduction in turbulent, convective heat transfer parameters observed in some supercritical data and in experiments with common gases can be due to property variation, acceleration, buoyancy or combinations of these phenomena, depending on the conditions of the applications. In this study, the measurement for the secondary flow driven by buoyancy was carried out on the supercritical carbon dioxide turbulent flows in the different boundary condition with the constant mass flow rate. The available measuring techniques were used to clarify the behaviour of any supercritical fluid. Laser Doppler Velocimeter (LDV) and a special device was used to measure the secondary velocity and turbulent characteristics of the supercritical flows.

Evaluation of Mechanical Properties of Welded Metal in Tailored Steel Sheet Welded by $ CO_2$ Laser ($ CO_2$레이저 합체박판 용접부의 기계적 물성평가)

  • Ghoo, Bon-Young;Keum, Young-Tag
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.4
    • /
    • pp.142-150
    • /
    • 2001
  • Automotive manufactures have taken more interests in tailored sheet metals for improving the rigidity, weight reduction, crash durability, and cost savings so that their application to auto-bodies has been increased. However, since the tailored sheet metals do not behave like un-welded sheet metals in press forming operations, the stamping engineers no longer rely only on conventional forming techniques. Futhermore, there is no clear understanding of the characteristics of welded metal which influence the overall press formability of tailored sheet metals. Recently, the computer simulations are prevailing for the evaluation of the formability. Unfortunately, the mechanical property of tailored sheet metal has to be quantitatively defined in the simulation. In this study, the analytical equations are formulated in order to find the mechanical properties of the welded metal in the tailored sheet metal welded by co$_2$laser. Based on force distribution assumption, the constitutive behavior of the welded metal is investigated using uniaxial tensile test results of base metals and tailored sheet metal. Then, the strength coefficient, work-hardening exponent, and plastic strain ratio of laser-welded metal are calculate from those of base metals and tailored sheet metal. In addition, the existence of weld defects in the welded metal is indirectly detected by examining the slop of strength coefficient of the welded metal.

  • PDF

Carbon dioxide LASER-aided management of oral mucosal diseases (이산화탄소(CO2) 레이저로 치료하면 좋은 구강점막질환)

  • Byun, Jin-Seok
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.391-397
    • /
    • 2018
  • Mess removal, electrocoagulation, cryosurgery are conventional methods in the treatment of various oral mucosal diseases. However, there are several problems or complication during or after surgery using conventional tools. Recently, LASER gradually become useful tool in the surgery of oral mucosal diseases. Of the LASER, carbon dioxide-mediated LASER is widely used one. Carbon dioxide LASER has many advantages such as good bleeding control, decreased damage to adjacent tissue, decreased pain and swelling, reduced scar formation, even bacteriocidal effects. In this reports, the author describe pros and cons of LASER, especially focused on carbon dioxide, and shed light on the field of LASER application in treatment of various oral mucosal diseases.

  • PDF

Effect of Non-Perforated Breathable Films on the Storability of Sprout Vegetables in Modified Atmosphere Condition (레이저 가공 비천공 Breathable필름이 새싹채소의 Modified Atmosphere 저장에 미치는 영향)

  • Choi, In-Lee;Baek, Jun Pill;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.22 no.2
    • /
    • pp.167-174
    • /
    • 2013
  • Six kinds of sprout vegetables were applied three and six types of non-perforated breathable propylene films (NPB film) for individual and mixed modified atmosphere (MA) package condition at $10^{\circ}C$ on this study. As a tah tasai, kohlrabi, rape, chinese cabbage, red radish, broccoli sprouts were packaged by 20,000, 60,000, and 100,000 $cc{\cdot}m^{-2}{\cdot}day{\cdot}atm$ non-perforated breathable films for seven days storage. Mixed sprout vegetables were used 20,000 cc, 40,000 cc, 60,000 cc, 80,000 cc, and 100,000 $cc{\cdot}m^{-2}{\cdot}day{\cdot}atm$ non-perforated breathable films for seven days storage. Loss rate of fresh weight, changes of carbon dioxide, oxygen, and ethylene gas concentration were measured during the storage. Visual quality and off-flavor were rated by panel tests after seven days storage. Each sprout vegetable storage with film tests had been shown under the 0.5% fresh weight loss in every packaged films, and the 20,000cc NPB film package had been suitable atmosphere condition in the carbon dioxide and oxygen gas concentration. Appearance and off-odor of sprouts packaged with 20,000cc NPB film were shown better than other films because of the proper gas movement through the film to outside during the storage. Fresh weight loss of the mixed sprout vegetables had no difference among the NPB films for seven days storage. The 20,000 cc film had been resulted in that exchange rate of carbon dioxide and oxygen was highest cause of low film permeability than sprouts respiration. But the film is not good for storage because it has been made poor value of off-order even showed high visual quality from panel test after storage. 40,000 cc and 60,000 cc non-perforated breathable films were more suitable for mixed sprout vegetable storage at $10^{\circ}C$. These result suggested that 20,000 cc NPB film was good for single packaged sprout vegetable and 40,000 cc and 60,000 cc non-perforated breathable films were good for mixed packaged sprout vegetable.

Effect of Non-Perforated Breathable Films on the Quality and Shelf Life of Paprika during MA Storage in Simulated Long Distance Export Condition (비천공 Breathable필름이 장거리 모의 수출 조건에서 파프리카의 MA 저장중 품질과 저장수명에 미치는 영향)

  • Choi, In-Lee;Yoo, Tae-Jong;Kim, Il-Seop;Lee, Yong-Beom;Kang, Ho-Min
    • Journal of Bio-Environment Control
    • /
    • v.20 no.2
    • /
    • pp.150-155
    • /
    • 2011
  • The aim of this study was investigated long distance export condition of paprika from Korea to Canada, and evaluated the effect of non-perforated breathable films on the storability of paprika during MA storage in the simulated long distance export condition. The long distance export condition of paprika from Korea to Canada was $7{\pm}1^{\circ}C$ and RH 90% during shipping for 20 days, and then the temperature of that was increased to $13^{\circ}C$ for 3 hours during transferring from refrigerated container to storage room in Canada, and decreased $3{\sim}4^{\circ}C$ for 3 days before distributing to local markets. The temperature and relative humidity of local markets was $16^{\circ}C$ and 60%, respectively. The packing material treatments were non-packing, as control, perforated film (6 mm diameter hole, $18holes/m^2$), and 3 kind of laser treated non-perforated films (oxygen transmission rate was 5,000, 20,000 and 100,000 $cc/m^2{\cdot}day{\cdot}atm$). Under the simulated long distance export condition; $7^{\circ}C$ and RH 90% for 15 days and then $20^{\circ}C$ and RH 55% for 7 days, the fresh weight loss of paprika was less than 1% in 3 kind of laser treated non-perforated film treatments but was more than 4% in control and perforated film treatment that showed severe deterioration of visual quality after 20 days of storage. The atmosphere of paprika packages was changed 5% oxygen and 15% carbon dioxide in 5,000 $cc/m^2{\cdot}day{\cdot}atm$ treatment, and 16% oxygen and 4~5% carbon dioxide in 20,000 $cc/m^2{\cdot}day{\cdot}atm$ treatment during room temperature storage after cold storage for 15 days. A carbon dioxide concentration of these 2 treatments was exceeded the optimal MA and CA condition. There was no significant difference in ethylene concentration among 3 kind of laser treated non-perforated film treatments. A paprika packed with 100,000 $cc/m^2{\cdot}day{\cdot}atm$ non-perforated film showed the highest visual quality under the simulated long distance export condition. However, the firmness and soluble solids did not show any significant difference among 3 kind of laser treated non-perforated film treatments. Therefore, we may suggest that 100,000 $cc/m^2{\cdot}day{\cdot}atm$ laser treated non-perforated film was the proper film for MAP of paprika under long distance export condition that was $7{\pm}1^{\circ}C$ and RH 90% for 15 days, and then $20^{\circ}C$ and RH 55% for 7 days.

Study on Current Switching in Electronic Devices Based on Vanadium Dioxide Thin Films Using CO2 Laser (이산화탄소 레이저를 이용한 바나듐 이산화물 박막 전자 소자에서의 전류 스위칭에 관한 연구)

  • Kim, Jihoon;Lee, Yong Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • With a collimated $CO_2$ laser beam, the bidirectional current switching was realized in a two-terminal electronic device based on a highly resistive vanadium dioxide($VO_2$) thin film. A $VO_2$ thin film was grown on a $Al_2O_3$ substrate by a pulsed laser deposition method. For the fabrication of a two-terminal electronic device, the $VO_2$ thin film was etched by an ion beam-assisted milling method, and the $VO_2$ device, of which $VO_2$ patch width and electrode separation were 50 and $100{\mu}m$, respectively, was fabricated through a photolithographic method. A bias voltage range for stable bidirectional current switching was found by using the current-voltage property of the device measured in a current-controlled mode. The transient responses of bidirectionally switched currents were analyzed when the laser was modulated at a variety of pulse widths and repetition rates. A switching contrast was measured as ~3333, and rising and falling times were measured as ~39 and ~21ms, respectively.

Advanced Aluminum Welding Technologies for Productivity Improvement (생산성 향상을 위한 신개념 알루미늄 용접 방법)

  • Cho, Yong-Joon;Lee, So-Young;Chang, In-Sung;Do, Sung-Sup
    • Proceedings of the KWS Conference
    • /
    • 2009.11a
    • /
    • pp.19-19
    • /
    • 2009
  • 최근, 유한한 에너지 자원의 한계와 지구 온난화 등으로 세계의 제조 산업은 새로운 국면을 맞이하고 있으며, 특히, 자동차 산업은 화석연료를 주 에너지원으로 사용한다는 점과 이 연료를 연소시킬 때 발생하는 이산화탄소가 지구 온난화의 주된 원인이 될 수 있다는 점에서 상기 문제들을 해결하기 위한 다양한 방법에 주목하고 있다. 그 중에서 자동차의 생산기술 측면에서 볼 때, 가장 중요한 이슈는 차체 경량화다. 자동차 차체는 자동차를 구성하고 있는 여러 가지 부품 중에서 약 40% 정도의 무게 비율을 차지하고 있기 때문에, 차체 경량화는 연비향상과 이산화탄소 배출가스 감소와 직접적인 관계를 가지고 있다. 다양한 차체 경량화 방법 중에서 가장 쉽게 접근할 수 있는 방법이 경량소재 적용에 의한 경량화 방법이다. 현재, 탄소섬유 강화 플라스틱과 같이 무게 절감 비율을 최대화 할 수 있는 소재들도 개발되어 일부 적용되고 있지만, 일반적으로 차체 경량화 소재로 가장 널리 사용되고 있는 소재는 알루미늄 합금이며, 이에 대한 차체 적용 비율이 점차로 높아지는 추세에 있다. 이에, 본 연구에서는 알루미늄 합금이 차체에 적용되었을 때의 장단점을 살펴보고, 알루미늄 합금을 적용한 차체 생산과정에서 유의해야 될 사항들과 이를 바탕으로 하는 생산성 극대화 방안에 대하여 고찰하였다. 먼저, 기존의 알루미늄 저항 점 용접공법의 단점을 최소화하고 대량생산 체계에 적합하도록 개발된 새로운 개념의 저항 점 용접 시스템에 대해 그 성능과 양산성을 검증하였다. 구리 전극과 알루미늄 피용접물 사이에 프로세스 테이프를 삽입하여 용접하는 이 시스템은 열전도성이 큰 알루미늄 용접부에서 저전류의 조건에서도 효과적으로 균일한 발열현상이 발생하게 하였으며, 전극 팁 드레싱 없이 모든 용접점이 항상 동일한 조건에서 용접이 이루어질 수 있도록 하였다. 용접 조건 설정에 있어서도 용접전류가 통전되는 순간에 전극 가압력을 자유로이 변형시켜 용접부 크랙 발생을 최소화할 수 있음을 확인하였다. 알루미늄의 또 다른 대표적인 접합방법인 아크용접에 있어서는 용접 입열량을 조절하여 용접변형을 최소화 할 수 있는 아크용접 시스템에 대해 양산성과 적용 타당성을 검토하였다. 와이어 송급 방향을 자유자재로 바꿀 수 있는 이 시스템의 특성에 의해 스패터를 최소화하면서 용융금속이 효과적으로 모재에 금속이행 될 수 있음을 확인하였으며, 판재, 압출재, 및 다이캐스팅재 등 다양한 차체 소재에 대한 용접 가능성 및 미그-레이저 하이브리드 용접과의 비교분석을 통하여 차체 박판 용접에서도 최소의 열변형으로 효과적으로 사용될 수 있음을 보였다.

  • PDF

The Effect on Treatment of Peri-implantitis with Carbon Dioxide Laser: An Experimental Study in Dogs (임플란트 주위염 치료시 이산화탄소 레이저의 효과)

  • Kim, Hak-kyun;Kim, Su-gwan;Kang, Dong-wan;Lim, Sung-chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.43-53
    • /
    • 2007
  • The purpose of this experimental study was to examine the effect of the decontamination of carbon dioxide ($CO_2$) laser in treatment of ligature-induced peri-implantitis in dogs. A total 24 implants with a sandblasted with large-grit and acid-etched (SLA) surface were inserted in six mongrel dogs. After a 3-month healing period, experimental peri-implantitis characterized by a bone loss of about 3mm was established by inducing with wires. And then wires were removed and plaque control was implemented. Surgical treatment involving flap procedure + debridement of implants surface with chlorhexidine and saline (group 1), flap procedure + GBR with absorbable collagen membrane (Bio-Gide) and mineralized bone graft (Bio-Oss) (group 2), and flap procedure + $CO_2$ laser application + GBR (group 3) was performed. The animals were killed 8 weeks and 16 weeks after treatment, respectively. A histomorphometric analysis confirmed statistically considerable new bone formation within the limit of the 5 most coronal threads in group 3 compared with group 1 at 16 weeks (P<0.05). And intragroup analysis showed considerable increase of new bone formation in group 3 at 16 weeks compared with 8 weeks (P<0.05). The present study demonstrates considerable new bone formation after treatment of experimental peri-implantitis with flap procedure, $CO_2$ laser application and GBR.

Calibration of δ13C values of CO2 gas with different concentrations in the analysis with Laser Absorption Spectrometry (레이저흡광분석기(Laser Absorption Spectrometry)를 이용한 CO2가스의 탄소안정동위원소비 보정식 산출)

  • Jeong, Taeyang;Woo, Nam C.;Shin, Woo-Jin;Bong, Yeon-Sik;Choi, Seunghyun;Kim, Youn-Tae
    • Economic and Environmental Geology
    • /
    • v.50 no.6
    • /
    • pp.537-544
    • /
    • 2017
  • Stable carbon isotope ratio of carbon dioxide (${\delta}^{13}C_{CO2}$) is used as an important indicator in the researches for global climate change and carbon capture and sequestration technology. The ${\delta}^{13}C$ value has been usually analyzed with Isotope Ratio Mass Spectrometer (IRMS). Recently, the use of Laser Absorption Spectrometry (LAS) is increasing because of the cost efficiency and field applicability. The purpose of this study was to suggest practical procedures to prepare laboratory reference gases for ${\delta}^{13}C_{CO2}$ analysis using LAS. $CO_2$ gas was adjusted to have the concentrations within the analytical range. Then, the concentration of $CO_2$ was assessed in a lab approved by the Korea Laboratory Accreditation Scheme and the ${\delta}^{13}C_{CO2}$ value was measured by IRMS. When the instrument ran over 12 hours, the ${\delta}^{13}C$ values were drifted up to ${\pm}10$‰ if the concentration of $CO_2$ was shifted up to 1.0% of relative standard deviation. Therefore, periodical investigation of analytical suitability and correction should be conducted. Because ${\delta}^{13}C_{CO2}$ showed the dependency on $CO_2$ concentration, we suggested the equation for calibrating the concentration effect. After calibration, ${\delta}^{13}C_{CO2}$ was well matched with the result of IRMS within ${\pm}0.52$‰.