• Title/Summary/Keyword: 이력특성

Search Result 881, Processing Time 0.033 seconds

Development of Estimation Functions for Strong Winds Damage Reflecting Regional Characteristics Based on Disaster Annual Reports : Focused on Gyeongsang Area (재해연보 기반 지역특성을 반영한 강풍피해예측함수 개발 : 경상지역을 중심으로)

  • Rho, Jung-Lae;Song, Chang-young
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.223-236
    • /
    • 2020
  • Purpose: In this study, a strong wind damage prediction function was developed in order to be used as a contingency during disaster management (preventive-preventive-response-recovery). Method: The predicted strong wind damage function proposed in this study took into account the re-enactment boy power, weather data and local characteristics at the time of damage. The meteorological data utilized the wind speed, temperature, and damage history observed by the Korea Meteorological Administration, the disaster year, and the recovery costs, population, vinyl house area, and farm water contained in the disaster report as factors to reflect the regional characteristics. Result: The function developed in this study reflected the predicted weather factors and local characteristics based on the history of strong wind damage in the past, and the extent of damage can be predicted in a short time. Conclusion: Strong wind damage prediction functions developed in this study are believed to be available for effective disaster management, such as decision making by policy-makers, deployment of emergency personnel and disaster prevention resources.

Study on Hydration Properties of High Strength Mass Concrete to apply Precast Concrete (PC 적용을 위한 고강도 매스콘크리트의 수화특성에 관한 연구)

  • Park, Heung-Lee;Kim, Sung-Jin;Lee, Hoi-Keun;Lee, Seung-Hoon;Park, Byung-Keun;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.661-664
    • /
    • 2008
  • As architectures have recently become high-risers and megastructured, stable high strength products have been ensured. Accordingly, use of precast concrete accouplement has been increased in order to facilitate air compression and rationalize construction. Since not only external heating but also internal temperature rise caused by the accumulation of cement hydration heat in manufacturing process, precast concrete members with large cross-section used for high-rise mega-structure's columns and beams may exhibit different temperature history compared to the precast concrete members for wall and sub-floor with relatively small cross-sections. Therefore, this study aims to elucidate the characteristics of temperature history of mass concrete members cast with high-strength concrete for precast concrete application. In this study, large cross-sectional precast concrete mock-up, unit cement quantity, and temperature histories in manufacturing precast concrete member under different curing condition were inclusively investigated.

  • PDF

A Study on the Strength Properties and the Temperature Curve of Winter Concrete According to the Difference of Curing Method in Mock-up Test (실물부재시험에서의 양생방법 차이에 따른 한중콘크리트외 온도이력 및 강도특성에 관한 연구)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.541-548
    • /
    • 2003
  • This study is to investigate the temperature curve and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of reducing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluation in-place concrete strength.

A Study on the Stress History and Secondary Compression of Saturated Clays Subjected to Precompression (사전압밀된 포화점토의 응력이력과 2차압밀에 관한 연구)

  • 김형주
    • Geotechnical Engineering
    • /
    • v.10 no.4
    • /
    • pp.167-180
    • /
    • 1994
  • A series of long term consolidation tests were conducted under loading -unloading and loading(pc) -unloading(p.) -reloading(p,) conditions using reconstituted clay in order to investigate the effect of stress history on secondary consolidation characteristics and the applicability of the secondary consolidation model suggested by Bjerrum to overconsolidated clays. According to the test results, the secondary compression settlement affected by the stress history in the first half of experimental period and the coefficient of secondary compression, C‥‥ is dependent on overconsolidation ratio, OCR(p,1 p.), maBium OCR (p./p.), and unloading duration time. Moreover the coefficient of secondary consolidation in the latter half of experimental period Cn is mainly affected by OCR and it gradually reduces with OCR increment. Finally the comparison of the experimental results with the Bjerrum model indicates that the Bjerrum model can be applied beyond certain range of stress history in the overconsolidated clay.

  • PDF

Structural Behavior of Joints between the Hysteretic Steel Damper Connector and RC Wall Depending on Connection Details (강재판형 이력댐퍼 연결부재와 RC벽체의 접합상세에 따른 구조거동)

  • Kang, In-Seok;Hur, Moo-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.6
    • /
    • pp.737-744
    • /
    • 2012
  • Hysteretic steel damper has been applied mainly to steel buildings. However, the usage in RC buildings is rapidly increasing recently. In order to apply the steel hysteretic damper in RC buildings, supporting elements of the damper should have sufficient strength and stiffness suitable for transferring damper forces to beams and walls. But due to the inevitable damage in reinforced concrete elements due to cracking, identification of the load transfer mechanism from damper to supporting element and hysteretic characteristics of the supporting element are extremely important in evaluating the damper behavior. Experiments were carried out on connection details between RC walls and supporting elements of the steel plate typed damper such as EaSy damper. The test results showed that fracture patterns of all specimens were almost identical except in the crack number and pattern associated with shear loading condition. Among the specimens, HD-3 shoed a well distributed cracks patterns along with good performance with respect to energy dissipation capacity, stiffness deterioration, and strength degradation.

Inelastic Behavior of Standard School Building according to Hysteresis Models (이력모델에 따른 표준학교건물의 비탄성거동 연구)

  • Je, Jeong-Hyun;Kim, Jin-Sang;Yoon, Tae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.838-845
    • /
    • 2009
  • The inelastic response characteristics of the standard school buildings depending on selection of hysteresis models are reviewed. Three earthquake records of El-centre, Santa-Monica, Taft and three artificial earthquake records in accordance with Korea standard are used and the inelastic response characteristics such as story shear force, story drift ratio, story displacement, hinge distribution state are reviewed with various hysteresis models. As results, story shear force is increased by maximum 60% according to hysteresis model. And Story drift ratio is increased by maximum 42% according to hysteresis model. And The result with clough model shows the maximum hinge distribution state.

Experimental study on a Cantilever Type Metallic Damper for Seismic Retrofit of Building Structures (건물의 내진보강을 위한 캔틸레버타입 강재댐퍼의 실험)

  • Ahn, Tae-Sang;Kim, Young-Ju;Park, Jin-Hwa;Kim, Hyung-Geun;Jang, Dong-Woon;Oh, Sang-Hoon
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.2
    • /
    • pp.149-161
    • /
    • 2012
  • The use of seismic energy-dissipative devices for passive control is increasing exponentially in the recent years for both new and existing buildings. Use of these devices started in and has been somewhat limited to developed countries. One of the current challenges is to promote the use of seismic dampers in earthquake-prone developing countries by lowering the cost of the devices. This paper proposed a new type of seismic damper based on yielding of a cantilever type metallic element for seismic retrofit of existing and new building structures. The hysteretic behavior and energy dissipation capacity of the proposed damper was investigated using component tests under cyclic loads. The experimental results indicated that the damping device had stable restoring force characteristics and a high energy dissipation capacity. Based on these results, a simple hysteretic model for predicting the load-displacement curve of the seismic damper was proposed.

The Effect of Thermal History Induced by Melt Spinning on the Mechanical Properties of Polylactic Acid Fibers (용융 가공에 의해 발현된 열 이력이 폴리락트산 섬유의 기계적 물성에 미치는 영향)

  • 천상욱;김수현;김영하;강호종
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.656-663
    • /
    • 2000
  • The Effects of thermal history during the melt spinning process on the mechanical properties and crystallinity of polylactic acid (PLLA) fibers have been studied. Thermal history applied on PLLA during the melt process caused the decrease of number-average molecular weights and this resulted in the lowering of orientation and crystallinity in PLLA fibers. As a result, the longer applied thermal history, the less tensile strength and modulus, and the higher elongation at break. It was also found that primary factor for controlling crystallinity of PLLA fiber was the stress induced crystallization while the thermal induced crystallization had a little effect on the crystallinity of PLLA fibers. However, the thermal induced crystallization turn out to be important in the crystallinity developed by annealing of PLLA fibers.

  • PDF

Cyclic Responses of Steel Reinforced ECC Column under Reversed Cyclic Loading Conditions (철근 보강된 ECC 기둥의 반복하중에 대한 이력거동)

  • Hyun, Jung-Hwan;Shim, Young-Heung;Bang, Jin-Wook;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.4
    • /
    • pp.75-82
    • /
    • 2015
  • In this study, experimental research was carried out to evaluate steel reinforced ECC (Engineered Cementitious Composites) column, which exhibits excellent crack control property and highly ductile behavior. Ordinary portland cement and high volume fly ash were used as binding materials in the mixture proportions for the purpose of achieving a high level of multiple cracking property with the tightly controlled crack width. To compare with the cyclic behavior of steel reinforced ECC column specimen, a conventional reinforced concrete column was prepared and tested under reversed cyclic loading condition. Based on the cyclic load test, ECC column exhibited higher cyclic behavior, compared to the conventional RC column, in terms of load carrying capacity and energy dissipation capacity.

On-line Tests on Collapse Mode Controlled Steel Frame (붕괴모드 컨트롤형 철골조 시스템의 온라인 지진응답실험)

  • Lee, Seung-Jae;Oh, Sang-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.9 no.1
    • /
    • pp.47-52
    • /
    • 2009
  • In this study, it is demonstrated by a pseudo dynamic earthquake response tests that combination of semi-rigid partial-strength using the high performance-high strength bolts and inter-story hysteretic damper system creates a fairly good structural system that satisfies not only the serviceability requirement under moderate earthquakes but unexpected failure of damper system.

  • PDF