• 제목/요약/키워드: 이단압축기

검색결과 11건 처리시간 0.018초

이단 압축기의 동력학적 설계 및 운전 특성에 관한 연구 (Design and Operation Characteristics of a Two-Stage Compressor)

  • 이용복;김태호;김창호;이남수;최동훈
    • 한국유체기계학회 논문집
    • /
    • 제5권1호
    • /
    • pp.55-61
    • /
    • 2002
  • The feasibility of an oil-free, motor-driven, two-stage centrifugal compressor supported by air bump bearings is investigated. This centrifugal compressor is driven by a 75 kW motor at an operating speed of 39,000 RPM, and a pressure ratio of the compressor is set up to 4. The analysis is performed by using bearing equilibrium position, heaving stillness, Campbell diagram, unbalance response, and stability. It is demonstrated in this paper that air bump bearings can be adopted well to an oil-free, motor-driven, centrifugal compressor. Specially, Cu-coated bump bearings have enough damping force to reduce a synchronous unbalance for rigid modes of the two-stage compressor. Futhermore, this concept may be applied to the flexible rotor system such as high speed turbomachinery with a super critical speed.

이단 압축기의 동력학적 설계 및 운전 특성에 관한 연구 (Design and Operation Characteristics of A Two-Stage Compressor)

  • 이용복;이남수;김태호;김창호;최동훈
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.469-474
    • /
    • 2001
  • The feasibility of a oil-free motor-driven two-stage centrifugal compressor supported by air bump bearings is investigated. This centrifugal compressor is driven by 75kW motor at an operating speed of 39,000RPM md a pressure ratio of the compressor is up to 4. The analysis is performed, based upon bearing equilibrium position, bearing stiffness, Campbell diagram, unbalance response and stability. It is demonstrated in this paper that air bump bearings can be adopted well to a oil-free motor-driven centrifugal compressor.

  • PDF

이단 압축기의 임펠러 및 시스템에 대한 최적설계 (An Optimum Design of the Compressor Wheel and the Rotor-Bearing System of a Two-Stage Compressor)

  • 이용복;김종립;최동훈;김광호;김창호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.129-134
    • /
    • 2001
  • The paper presents the optimal design of a oil-free two-stage compressor, which is driven by 75 kW motor at an operating speed of 39,000 rpm, and the pressure ratio of which is up to 4. First, an attempt is made to obtain the optimal design of a bump bearing which supports a compressor rotor. Second, bump bearings and shaft are considered simultaneously, and the weighted sum of rotor weight and frictional torque is minimized. Finally, the optimal geometry of compressor wheel is considered. The mean efficiency and the - minimum efficiency are maximized respectively. The results presented in this paper provide important design information necessary to reduce the energy loss.

  • PDF

천연혼합냉매를 이용한 압축/흡수식 고온히트펌프의 실험적 연구 (Experimental Study on Compression/Absorption High-Temperature Hybrid Heat Pump with Natural Refrigerant Mixture)

  • 김지영;박성룡;백영진;장기창;나호상;김민성;김용찬
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1367-1373
    • /
    • 2011
  • 본 연구에서는 천연냉매를 적용한 압축/흡수식 하이브리드 고온제조 히트펌프를 실험적으로 연구한 결과를 제시하였다. 압축/흡수식 히트펌프는 기존의 증기압축 히트펌프에 비해 고온영역을 포함한 넓은 생산온도범위, 높은 승온기능, 다양한 용량 제어방법 등 여러가지 장점을 가지고 있다. 제작된 하이브리드 히트펌프는 현재 실제 산업현장에 적용하기 이전의 초기 시제품 단계로 실험실에 설치하여 운전하였으며, 주요 구성부품으로는 이단압축기, 흡수기, 재생기, 과열냉각기, 용액 열교환기, 용액펌프, 기액분리기/정류기 등이다. 성능실험에서 $50^{\circ}C$의 열원을 고온 및 저온열원으로 사용한 결과 $90^{\circ}C$ 이상의 고온수 토출과 10 kW급의 난방 용량을 얻을 수 있었다. 혼합냉매의 성분비 변화에 따른 압축기/펌프 유량의 순환비 변화 및 다양한 성능변화를 실험적으로 관찰하였으며, 시스템의 효율과 용량에 있어 최적 성분비가 존재함을 확인하였다.

NH3/H2O 혼합냉매를 사용한 압축/흡수식 히트펌프 시스템의 흡수기 최적화에 관한 실험적 연구 (Experimental Study on Optimization of Absorber Configuration in Compression/Absorption Heat Pump with NH3/H2O Mixture)

  • 김지영;김민성;백영진;박성룡;장기창;나호상;김용찬
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.229-235
    • /
    • 2011
  • 본 연구는 암모니아/물 혼합냉매를 이용한 압축/흡수식하이브리드 히트펌프 개발에 관한 연구이다. 히트펌프 사이클은 증기압축식과흡수식을 혼합한 개념으로 이단압축기, 흡수기, 재생기, 과열냉각기, 용액열교환기(SHX), 용액펌프, 정류기, 기액분리기 등으로 구성되어 있다. 압축/흡수식 히트펌프는 상변화 열교환과정에서 높은 온도구배를 이용하여 $90^{\circ}C$ 이상의 고온을 제조하기 위한 목적으로 고안되었다. 특히 흡수기에서의 응축과정은 비열변화로 인하여 온도변화에 비선형성이 뚜렷한데, 시스템 성능 최적화를 위하여는 흡수기의 설계가 중요하다. 본 연구에서는 다수의 판형열교환기로 흡수기를 구성하였는데 열교환기의 용량, 형태, 배치에 따른 성능특성을 실험적으로 관찰하였다.

이단 왕복동 공기압축기 구조에 따른 관성력 비교 (Inertia Force Comparison of 2 Stage Reciprocating Air Compressors)

  • 김영철;안국영
    • 한국유체기계학회 논문집
    • /
    • 제12권4호
    • /
    • pp.23-29
    • /
    • 2009
  • For the purpose of high outlet pressure, compactness and low vibration and noise, 2 stage reciprocating air compressors can have various cylinder arrangement: opposed, in-line, and V type. This paper presents an effective method to calculate the inertia forces and to design counter weight. This method is based on the complex representation for the orbital behavior of the compressor shaft. This method helps to find the optimal balancing rate easily to reduce the inertial force or moment. This paper shows that the residual inertia forces of the single throw shafts and the residual inertia moments of the double throw shafts remain to be imbalanced.

플래쉬 중각냉각기와 플래쉬 가스 바이패스를 이용한 이단압축 이산화탄소 사이클의 냉방성능에 관한 해석적 연구 (Simulation Study on the Cooling Performance of the Two-Stage Compression CO2 Cycle with the a Flash Intercooler and Flash Gas Bypass)

  • 곽명석;조홍현
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.17-24
    • /
    • 2012
  • 본 연구에서는 효율적인 냉방시스템의 성능특성을 연구하기 위하여 2단압축을 이용한 이산화탄소 냉방사이클의 성능에 대하여 해석적 연구를 진행하였다. 2단압축을 이용한 플래쉬 중간냉각(flash intercooler)과 플래쉬 가스 바이패스(flash gas bypass) 사이클에 대한 해석적 모델을 개발하였으며 실내온도, 실외온도, 그리고 1단 및 2단 EEV 개도를 변화시켰다. 그 결과 FI와 FGB 사이클의 성능계수는 실외온도를 변화시켰을 경우 각각 28.5%, 22.1% 정도 감소하였으며, 실내온도 변화에 따른 이단압축 사이클의 성능변화는 단단압축 사이클에 비하여 적은 것으로 나타났다. 또한 저단 및 고단 EEV 개도를 변경하였을 경우 성능은 각각 13.5%, 6.9% 그리고 0.9%, 2.6% 정도 증가하는 것으로 나타나 고단 EEV 개도보다 저단의 EEV 개도의 변화가 시스템의 성능에 미치는 영향이 큰 것으로 확인되었다. FI 사이클은 다양한 운전조건에서 시스템의 성능이 가장 높게 나타나는 것을 확인할 수 있었다.

공기윤활 다엽포일 제어널 베어링으로 지지된 이단 압축기의 설계 (Design of A two-stage Compressor Supported by Air-lubricated Multi-leaf Foil Journal Bearings)

  • 김태호;이용복;김창호;이남수;김한길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.936-941
    • /
    • 2001
  • This paper deals with the design of oil-tree motor-driven two-stage centrifugal compressor supported by air-lubricated multi-leaf foil bearings. The design of this compressor is performed, based upon prediction of critical speeds, load capacity, and stability. It is demonstrated in this paper that multi-leaf foil bearings can be adopted to satisfactorily support this centrifugal compressor.

  • PDF

이산화탄소를 이용한 냉동·냉장 시스템의 성능연구 (Performance of Carbon Dioxide System for Freezing and Refrigeration)

  • 김윤섭;윤린
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.81-86
    • /
    • 2015
  • Performance of freezing and refrigeration systems in supermarket, which utilized $CO_2$ as a refrigerant, was investigated by using the Pack Calculation II. The configuration of simulated systems was basic parallel refrigeration system, cascade system, and two-stage system. The $CO_2$ cascade system showed higher COP than basic parallel R404A system by 13% for MT and 62% for LT, respectively. Among the $CO_2$ cascade systems, R717(MT)-$CO_2$(LT) showed the highest performance. Open-type intercooler method showed higher performance than liquid injection for the two-stage $CO_2$ systems.

핫가스 바이패스 및 압축기 가변속 제어에 의한 공작기계용 수냉각기의 성능 비교 (Comparison of System Performances of Hot-gas Bypass and Compressor Variable Speed Control of Water Coolers for Machine Tools)

  • 정석권;이단비;윤정인
    • 설비공학논문집
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, the needs of system performances such as working speed and processing accuracy in machine tools have been increased. Especially, the speed increment generates harmful heat at both moving part of the machine tools and handicrafts. The heat is a main drawback to progress accuracy of the processing. Hence, a cooler system to control temperature is inevitable for the machine tools. In general, two representative control schemes, hot-gas bypass and variable speed control of a compressor, have been adopted in the water cooler system. In this paper, comparisons of system performances according to the control schemes in a cooler for machine tools were conducted in detail. Each proportional-integral feedback controller for the two different control systems is designed. The system performances, especially the temperature control accuracy and coefficient of performance which is a criterion of energy saving, were mainly analyzed through various experiments using 1RT water cooler system with different two types of control scheme. These evaluations will provide useful information to choose suitable water cooler system for the engineers who design controllers of the cooler system for machine tools.