• Title/Summary/Keyword: 이다

Search Result 352,473, Processing Time 0.303 seconds

An exploratory study on the characteristics of technology innovation persistence of Korean firms (한국 기업의 기술혁신 지속 특성에 대한 탐색적 연구)

  • Song, Changhyeon;Lee, Jungwoo;Jang, Pilseong
    • Journal of Technology Innovation
    • /
    • v.29 no.3
    • /
    • pp.1-31
    • /
    • 2021
  • With the growing importance of technology innovation as a key factor for firms' competitive advantage, 'innovation persistence' became also an important research subject. 'Innovation Persistence' is a concept that indicates whether or not firms' innovation activity or performance continues. However, the data used for innovation studies are carried out as cross-sectional surveys in most countries. For this reason, studies dealing with longitudinal aspect of innovation persistence are rare. In particular, there is almost no research on innovation persistence using Korean innovation survey data. This study reviews the concepts and characteristics of innovation persistence based on extant literature, and perform an empirical analysis on the status and features of Korean firms' technology innovation persistence. Based on the data of the Korean Innovation Survey (KIS) conducted every other year from 2012 to 2018, panel data on 3,379 firms which observed multiple times are constructed. As a result, only part of the firms with persistent innovation were observed (for innovation performance 10~12%, for innovation activity 15~17%), and it was found that the persistence of non-innovation was remarkable(about 52~57%). And it was confirmed that the persistence of innovation activities is stronger than that of innovation performance. Besides, some features by sub-types of innovation appeared. Product innovation showed higher persistence than process innovation, and internal R&D also showed higher persistence than joint/external R&D. As a result of additional logit analysis to identify factors, it was found that radical or gradual product innovation is the most influential factor in persisting innovation in the next period. Since the sample selection bias due to a limitations of raw data might exist in the panel data constructed in this study, it should be noted that faulty generalization of the results are not allowed. Nevertheless, this is the first study to examine the technology innovation persistence targeting Korean firms and is expected to be a starting point for follow-up studies. It is anticipated that advanced research results will be drawn through the establishment of official panel data and improved methodologies.

Comparison of internal and marginal fit of crown according to milling order in a single machinable wax disc (단일 절삭가공용 왁스 디스크 내에서 순차적 절삭가공 순서에 따른 크라운의 내면 및 변연 적합도 비교)

  • Song, Jun-Beom;Lee, Jonghyuk;Ha, Seung-Ryong;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.395-404
    • /
    • 2021
  • Purpose. The purpose of present study was to evaluate the effect of changing structural stability of wax disc on the fit of prosthesis when the milling proceeded in order. Materials and methods. Prepared maxillary left first molar was used to fabricate a Ni-Cr alloy reference model. This was scanned to design crown and then wax pattern was milled, invested and cast to fabricate prosthesis. The wax patterns located in a row centrally within a single wax disc were set into a total of five groups ranging from WM1 group that was first milled to WM5 group that was last milled and the number of each group was set as 10. Silicone replica technique was used to measure the marginal gap, axial internal gap, line angle internal gap, occlusal internal gap. Data was evaluated with one-way ANOVA with significance level set at α = .05 and then Tukey HSD test was conducted for post analysis. Results. Marginal gap measured in each group, it was 40.41 ± 2.15 ㎛ in WM1 group, 40.44 ± 2.23 ㎛ in WM2 group, 39.96 ± 2.25 ㎛ in WM3 group, 39.96 ± 2.48 ㎛ in WM4 group, and 40.57 ± 2.53 ㎛ in WM5 group. No significant difference was found between groups. The significant difference between the groups was also not found in the axial internal gap, line angle internal gap, and occlusal internal gap. Conclusion. Internal and marginal fit of single crown to the sequential order of milling processing in the single machinable wax disc did not seem to be affected by the sequence.

Compositional changes in maesil-cheong formulated with turanose during the storage period (투라노스 당침을 통해 제조된 매실청의 저장기간 중 성분 함량 변화)

  • Kim, Jung-Geun;Yoo, Sang-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.6
    • /
    • pp.688-694
    • /
    • 2021
  • Turanose is a potential candidate for use as a functional sweetener because of its gentle taste, low calorie, and non-cariogenicity. The aim of this study was to replace sucrose with turanose to produce health-beneficial maesil-cheong. Quality effects of turanose on maesil-cheong were evaluated by determining the contents of free sugars, organic acids, amygdalin, and antioxidant activity. The pH and Brix values of sucrose- and turanose-based maesil-cheong remained at the same level between 2.83 and 3.00 and 54.6-58.6°Bx, respectively, after 90-day storage. Among oxalic, malic, and citric acids, citric acid content was the highest in both maesil-cheong samples. Turanose did not significantly hydrolyze in maesil-cheong, whereas sucrose was completely hydrolyzed to glucose and fructose. Thus, turanose is suitable for the development of acidic maesil-cheong to improve its health promoting effect. Turanose showed product qualities similar to sucrose-based maesil-cheong. Turanose can be used as a functional sweetener or bulking agent in processed foods.

A Study on the Optimal Image Acquisition Time of 18F- Flutemetamol using List Mode (LIST mode를 이용한 18F-Flutemetamol 의 최적 영상획득 시간에 관한 연구)

  • Ryu, Chan-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.891-897
    • /
    • 2021
  • With the development of Amyloid PET Tracer, the accuracy of Alzheimer's diagnosis can be improved through the identification of beta-amyloid neurites. However, the long image acquisition time of 20 minutes can be difficult for the patient. PET/CT scans are sensitive to patient movement and may partially affect test results. In this study, we studied the proper image acquisition time without affecting the quantitative evaluation of the image through the list mode acquisition method according to the time of the distribution of radioactive drugs in the body. The list mode includes information about time compared to the existing frame mode, and it is easy to analyze data because it can reconstruct images about the time that researchers want. The research method obtained a reconstructed image by time using a list mode of 5min frame/bed, 10min frame/bed, 15min frame/bed, and 20min frame/bed to compare the difference between signal-to-pons take ratio (SNR) and lesion-to-pons uptake ratio (LPR) and the difference in reading time to obtain an appropriate image. As a result of quantitative analysis, when measuring in list mode, SUVmean values decreased in 6 regions of interest as the image acquisition time increased, but showed the largest difference in 5 min/bed images, followed by 10 min/bed and 15 min/bed. As a result, the difference in SUVmean values decreased. Therefore, it was found that SUVmean values at 15 min/bed did not differ enough to not affect image evaluation. There was no difference in LPR values. As a result of the qualitative analysis, there was no change in the reading findings according to the PET image acquisition time and there was no significant difference in the qualitative analysis score of the image reconstruction according to time. As a result of the study, there is no significant difference between 15 min/bed and 20 min/bed images during the 18F-flutemetamol PET/CT test, so it can be said that it is clinically useful to reduce the image acquisition time selectively using 15 min/bed via list mode depending on the patient's condition.

Simultaneous Removal of NO and SO2 using Microbubble and Reducing Agent (마이크로버블과 환원제를 이용한 습식 NO 및 SO2의 동시제거)

  • Song, Dong Hun;Kang, Jo Hong;Park, Hyun Sic;Song, Hojun;Chung, Yongchul G.
    • Clean Technology
    • /
    • v.27 no.4
    • /
    • pp.341-349
    • /
    • 2021
  • In combustion facilities, the nitrogen and sulfur in fossil fuels react with oxygen to generate air pollutants such as nitrogen oxides (NOX) and sulfur oxides (SOX), which are harmful to the human body and cause environmental pollution. There are regulations worldwide to reduce NOX and SOX, and various technologies are being applied to meet these regulations. There are commercialized methods to reduce NOX and SOX emissions such as selective catalytic reduction (SCR), selective non-catalytic reduction (SNCR) and wet flue gas desulfurization (WFGD), but due to the disadvantages of these methods, many studies have been conducted to simultaneously remove NOX and SOX. However, even in the NOX and SOX simultaneous removal methods, there are problems with wastewater generation due to oxidants and absorbents, costs incurred due to the use of catalysts and electrolysis to activate specific oxidants, and the harmfulness of gas oxidants themselves. Therefore, in this research, microbubbles generated in a high-pressure disperser and reducing agents were used to reduce costs and facilitate wastewater treatment in order to compensate for the shortcomings of the NOX, SOX simultaneous treatment method. It was confirmed through image processing and ESR (electron spin resonance) analysis that the disperser generates real microbubbles. NOX and SOX removal tests according to temperature were also conducted using only microbubbles. In addition, the removal efficiencies of NOX and SOX are about 75% and 99% using a reducing agent and microbubbles to reduce wastewater. When a small amount of oxidizing agent was added to this microbubble system, both NOX and SOX removal rates achieved 99% or more. Based on these findings, it is expected that this suggested method will contribute to solving the cost and environmental problems associated with the wet oxidation removal method.

Response of Structural, Biochemical, and Physiological Vegetation Indices Measured from Field-Spectrometer and Multi-Spectral Camera Under Crop Stress Caused by Herbicide (마늘의 제초제 약해에 대한 구조적, 생화학적, 생리적 계열 식생지수 반응: 지상분광계 및 다중분광카메라를 활용하여)

  • Ryu, Jae-Hyun;Moon, Hyun-Dong;Cho, Jaeil;Lee, Kyung-do;Ahn, Ho-yong;So, Kyu-ho;Na, Sang-il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1559-1572
    • /
    • 2021
  • The response of vegetation under the crop stress condition was evaluated using structural, biochemical, and physiological vegetation indices based on unmanned aerial vehicle (UAV) images and field-spectrometer data. A high concentration of herbicide was sprayed at the different growth stages of garlic to process crop stress, the above ground dry matter of garlic at experimental area (EA) decreased about 46.2~84.5% compared to that at control area. The structural vegetation indices clearly responded to these crop damages. Spectral reflectance at near-infrared wavelength consistently decreased at EA. Most biochemical vegetation indices reflected the crop stress conditions, but the meaning of physiological vegetation indices is not clear due to the effect of vinyl mulching. The difference of the decreasing ratio of vegetation indices after the herbicide spray was 2.3% averagely in the case of structural vegetation indices and 1.3~4.1% in the case of normalization-based vegetation indices. These results meant that appropriate vegetation indices should be utilized depending on the types of crop stress and the cultivation environment and the normalization-based vegetation indices measured from the different spatial scale has the minimized difference.

Stand Structure and Sapling Growth Characteristics of Korean Red Pine Stands Regenerated by the Seed Tree Method (소나무 모수림 시업지의 임분구조 및 치수생육특성)

  • Lee, Daesung;Choi, Jungkee
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.4
    • /
    • pp.678-688
    • /
    • 2021
  • This study was conducted to provide growth characteristics and stand information in preparation for natural regeneration method and silvicultural treatment of seed tree method in Korean red pine stands by using the field inventoried data 18 years after the seed tree regeneration method in 2001 and analyzing the stand and sapling characteristics. The study area was located in the Research Forest of Kangwon National University, Chuncheon-si, Gangwon-do. In November 2018, we collected tree measurement factors, such as diameter at breast height (DBH), height, crown class, stem quality, tree age, and annual height increment on the established plots. We calculated the basal area, volume, height-diameter ratio (HD ratio), and additional stand density variables such as the relative density and %stocking to analyze the managed stands. The number of mother trees was 58 trees/ha, with a 17.7% stocking level, whereas the number of saplings was 2,330 trees/ha, with a 79.0% stocking level. In germination, the age distribution of saplings ranged from 2001 to 2007, with most belonging to 15-16 years. The development condition of saplings was 10 cm in DBH and 8 m in height. DBH and height were higher as the crown class is more dominant, and this difference was statistically significant in the analysis of variance and Duncan's multiple comparison test (p<0.0001). HD ratio ranged mostly between 80% and 90%, and more than 95% of sapling stems were of high quality, with a straight, unbroken top, non-sweep, and non-diseased stem. On average, the annual height increment of saplings was 21.9 cm at 1 year, 43.3 cm at 5 years, 54.3 cm at 10 years, and 64.3 cm at 15 years. The overall height growth with age increased smoothly. According to the analysis of covariance, the annual height growth by crown class differed significantly. The regression analysis parameters revealed that annual height growth increased with age and dominant crown class.

Development and Evaluation of Silicon Passive Layer Dosimeter Based Lead-Monoxide for Measuring Skin Dose (피부선량 측정을 위한 Lead-Monoxide 기반의 Silicon Passive layer PbO 선량계 개발 및 평가)

  • Yang, Seung-Woo;Han, Moo-Jae;Jung, Jae-Hoon;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.781-788
    • /
    • 2021
  • Due to the high sensitivity to radiation, excessive exposure needs to be prevented by accurately measuring the dose irradiated to the skin during radiation therapy. Although clinical trials use dosimeters such as film, OSLD, TLD, glass dosimeter, etc. to measure skin dose, these dosimeters have difficulty in accurate dosimetry on skin curves. In this study, to solve these problems, we developed a skin dosimeter that can be attached according to human flexion and evaluated its response characteristics. For the manufacture of the dosimeter, lead oxide (PbO) with high atomic number (ZPb: 82, ZO: 8) and density (9.53 g/cm3) and silicon binders that can bend according to human flexion were used. In the case of a dosimeter made of PbO material, the performance degradation has been prevented by using parylene and others due to the presence of degradation due to oxidation, but the previously used parylene is affected by bending, so a new form of passive layer was produced and applied to the skin dosimeter. The characteristic evaluation of the skin dosimeter was evaluated by analyzing SEM, reproducibility, and linearity. Through SEM analysis, bending was evaluated, reproducibility and linearity at 6 MeV energy were evaluated, and applicability was assessed with a skin dosimeter. As a result of observing the dosimeter surface through SEM analysis, the parylene passive layer PbO dosimeter with the positive layer raised to the parylene produced cracks on the surface when bent. On the other hand, no crack was observed in the silicon passive layer PbO dosimeter, which was raised to silicon passive layer. In the reproducibility measurement results, the RSD of the silicon passive layer PbO dosimeter was 1.47% which satisfied the evaluation criteria RSD 1.5% and the linearity evaluation results showed the R2 value of 0.9990, which satisfied the evaluation criteria R2 9990. The silicon passive layer PbO dosimeter was evaluated to be applicable to skin dosimeters by demonstrating high signal stability, precision, and accuracy in reproducibility and linearity, without cracking due to bending.

New Perspectives on Sunday School of Korean Church for Next Generation (다음 세대와 한국교회 주일학교의 새 전망)

  • Kim, Jeong Joon
    • Journal of Christian Education in Korea
    • /
    • v.67
    • /
    • pp.11-44
    • /
    • 2021
  • In the early 21st century, the global COVID-19 pandemic, which has arisen during the development of the technological science of the Fourth Industrial Revolution, has been a great challenge in all fields including politics, economy, industry, education and religion in Korean society. To prevent the spread of the COVID-19 epidemic, the Korean government announced 'social distancing guidelines,' focused on the 'prohibition of three conditions'(crowd, closeness, airtight) for safety reasons. These quarantine guidelines made it more difficult for Korean churches and Sunday schools to operate. In general, looking at the statistical data of the major denominations of the Korean Church in the second half of the 20th century, shows that the Church has entered a period of stagnant or declining growth. Data also show that the number of students attending Sunday School is decreasing. The researcher identified four causes of the crisis faced by the Korean church and Korean Sunday school entering the 21st century. These trends are influenced by the tendencies of postmodernism, the deconstruction of modern universalism, the certainty and objectivity of knowledge, and the grand narrative and worldview of diffusion. Moreover, it is a phenomenon in which the young population decreases in contrast to the increasing elderly population in the age of population cliff in Korean society. Sunday Schools are also facing a crisis, as the youth population, who will become the future heroes of the Korean church, is declining. Finally, constraints of Church and Sunday school education activities are due to COVID-19 Pandemic. As analysis shows the loss of the Church's educational vision and a decrease in the passion for education. Accordingly, the researcher suggests four new strategies for the next generation of Korean Sunday schools, whose ranges from 200 members or less; this range covers the majority of Sunday School program run by churches in Korea. First, in the age of postmodernism, a time of uncertainty and relativism, Christian Societies requires teachers who are certain of absolute Christian truth and faith. Second, in an era of declining population cliffs for younger generations, a shift to a home-friendly Sunday school paradigm is needed. Third, during the COVID-19 pandemic, educational activities must appropriately utilize face-to-face and non-face-to-face communication. Finally, even in difficult times, Korean Sunday school should nevertheless remember the Lord's great commandment(Matthew 28:18-20) and restore the vision and passion of education to announce and teach the gospel. The researcher hopes that this study will provide small, positive steps in rebuilding Korean Sunday school educational activities for future generations in difficult times.

Is it a Smile or Ridicule? Understanding the Positivity of Smile Emoticons between High and Low Status Teenagers in Online Games (미소인가? 조소인가?: 온라인 게임에서 지위가 높은 청소년과 낮은 청소년의 웃음 이모티콘 긍정성 이해 차이)

  • Lee, Guk-Hee
    • Science of Emotion and Sensibility
    • /
    • v.24 no.3
    • /
    • pp.3-16
    • /
    • 2021
  • Studies have found that people with higher social status pay little attention to other people's emotions and facial expressions. However, only a few studies have made similar observations on adolescents with high cyberspace social status. Therefore, this study sought to identify how adolescents with different online game character social statuses interpreted the smile emoticons in negative and positive situations, that is, did they perceive the emoticon to be positive (smile, encouragement, and consolation) or negative (derision, ridicule, and sarcasm). In Experiment 1, the participants were separated into three groups; those who had a lower than global average online game character status, those who had the same as the global average, and those who had higher than the global average. The participants were then asked to judge the meaning of the smile emoticon received in various positive or negative situations. In Experiment 2, the game character levels of the participants were set to be either higher or lower than the others' characters, and they were again asked to judge the meaning of the smile emoticon received in the positive or negative situations. In Experiment 3, the participants were separated into four groups; lower level than the average game character status (no information on the level of acquaintance's game character), lower than the average but higher than the character of the other, higher than the average status (no information on the other's character level), and higher than the average but lower than the character of the other, and asked to judge the meaning of the smile emoticon in positive or negative situations. It was found that when participants had a lower-level character compared to the average, had a lower-level character than the other, and had higher than the average but lower than the other's character, they interpreted the smile emoticon as derision, ridicule, or sarcasm. However, participants with higher level characters, higher than that of the other, and lower than the average but higher than the other interpreted the emoticon as a smile or consolation. This study was significant because it demonstrated the impact of an adolescent's social cyberspace status on their online communication.