• Title/Summary/Keyword: 의료선

Search Result 622, Processing Time 0.031 seconds

A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage (관전압 증가에 기인한 산란선 발생의 화질 영향 연구)

  • Park, Ji-Koon;Jun, Je-Hoon;Yang, Sung-Woo;Kim, Kyo-Tae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.663-669
    • /
    • 2017
  • In diagnostic medical imaging, it is essential to reduce the scattered radiation for the high medical image quality and low patient dose. Therefore, in this study, the influence of the scattered radiation on medical images was analyzed as the tube voltage increases. For this purpose, ANSI chest phantom was used to measure the scattering ratio, and the scattering effect on the image quality was investigated by RMS evaluation, RSD and NPS analysis. It was found that the scattering ratio with increasing x-ray tube voltage gradually increased to 48.8% at 73 kV tube voltage and to 80.1% at 93 kV tube voltage. As a result of RMS analysis for evaluating the image quality, RMS value according to increase of tube voltage was increased, resulting in low image quality. Also, the NPS value at 2.5 lp/mm spatial frequency was increased by 20% when the tube voltage was increased by 93 kV compared to the tube voltage of 73 kV. From this study, it can be seen that the scattering radiation have a significant effect on the image quality according to the increase of x-ray tube voltage. The results of this study can be used as basic data for the improvement of medical imaging quality.

$^{192}$Ir 선원의$\gamma$선 자기흡수효과 측정

  • 조운갑;한현수;박춘득;박울재;이철영
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.752-756
    • /
    • 1998
  • 산업용 및 의료용으로 사용되는 $^{192}$ Ir 방사선원에 대한 $\psi$선 자기흡수효과인자를 실험을 통하여 구하였다. 이를 위하여 3 mm $\psi$ x 3 mm t, 2.5 mm $\psi$ x 2.5 mm t, 2 mm $\psi$ x 2 mm Ir의 원주형 Ir 표적과 3 mm $\psi$ x 0.25 mm t, 3 mm $\psi$ x 0.1 mm t의 원판형 Ir 표적을 하나로의 PTS(Pneumatic Transport System)조사공에서 중성자 조사하였다. 이온전리함을 사용하여 각 Ir 표적의 방사능을 측정하고 계산에 의해서 구한 생성방사능 값과의 비를 구하는 방법으로 $^{192}$ Ir의 ${\gamma}$선 자기흡수효과인자를 구하였다. 이 값들은 원주형 표적에 대하여 각각 0.614, 0.687, 0.704 였고 원판형 표적에 대하여 각각 0.827, 0.875 였다. 원주형 Ir 표적내부의 중성자 자기흡수효과의 정도를 알아보기 위하여 2.5 mm $\psi$ x 0.25 mm t Ir 표적 10장을 포개어 중성자 방사화시킨 후 각 표적의 방사능을 측정한 결과 가장 바깥쪽 표적의 방사능이 중심부에 위치한 표적보다 약 2배정도 방사화가 많이 일어남을 알 수 있었다. 이번에 구한 ${\gamma}$선 자기흡수효과인자는 향후 산업용 및 의료용으로 사용되는 $^{192}$ Ir 방사선원의 사용자에게 제공되는 최종방사능을 평가하는데 유용하게 사용될 수 있다.

  • PDF

Characteristic of X-ray Equipment according to the Input Power Condition (입력전원의 변화에 따른 X선 기기의 특성평가)

  • Kim, Young-Pyo;Kim, Tae-Gon;Cheon, Min-Woo;Park, Yong-Pil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.10a
    • /
    • pp.773-775
    • /
    • 2010
  • Diagnostic X-ray high voltage generator needs high voltage input power when operated, if electric power conditions are not suitable, could not use diagnostic X-ray high voltage generator or could not use normally by abnormal working. If diagnostic X-ray system operated with abnormally by electric power conditions, it cause of difficulty of patient diagnosis. And we used auxiliary power with battery to operate diagnostic X-ray high voltage generator without using normal electric power. We made one device after designing of new electric circuit and we compared normal power X-ray system with battery powered X-ray system by described method in this thesis. And then we found characteristic and efficiency of diagnostic X-ray high voltage generator by different input power condition.

  • PDF

Medical Image Segmental ion using Gradient Vector Plow (Gradient Vector Flow을 이용한 의료영상 분할)

  • 김진철;김종욱;이배호;정태웅
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.478-480
    • /
    • 2002
  • 영상 분할은 임상에서의 진단과 분석 및 3차원 가시화를 위해 선행되어야 할 필수 과정이다. 의료영상은 영상이 가지는 데이터 자체의 고유한 제약들과 해부학적 변이성 때문에 영상분할에 어려움이 있다. 본 논문에서는 의료영상의 분할을 위해 스네이크의 새로운 외부 힘으로 Gradient Vector Flow(GVF)를 이용한 방법을 제안한다. 제안된 방법은 2차원 의료영상에서 에지 맵(edge map)을 구하고, GVF을 계산하여 스네이크의 경계선과 같이 관심 있는 특징의 에너지 함수가 최소가 되는 GVF 스네이크(snake)를 구한다. 제안된 방법을 초음파영상과 자기공명영상 같은 의료영상의 분할에 적용한 결과 기존의 스네이크와 달리 잡음이나 오목한 부분이 있는 객체들을 성공적으로 분할하였다.

  • PDF