• Title/Summary/Keyword: 의료선

Search Result 622, Processing Time 0.028 seconds

Conceptual Design and Examination of Required Functions of a Public Ship in Chuja-do (추자도 행정선의 필요기능 조사 및 선박 개념설계)

  • An, Kwang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.606-614
    • /
    • 2020
  • The administrative ship, Chuja-ho, is the only mode of transportation between manned islands in the Chuja-do, Jeju. Chuja-ho is a 25-year-old age, which is identified to pass the persisting period (25 years) for public ships, and there is an urgent need for a replacement. The residents of the island are also requesting that the new administrative ship be outfitted with medical functions because there is no sea transportation system for medical emergencies in Chuja-do. The purpose of this study is to examine the required functions of a new administrative ship outfitted with medical functions and to suggest a conceptual design. In order to review the necessity of an emergency patient transport system, user requirements were surveyed and analyzed, and the ship's condition assessed by ship experts who carried out an on-site survey and analysis of ship survey data. Thereafter, a conceptual design for a new administrative ship with medical functions was presented. The results of this study can be used during a review of a new budget plan and for basic ship designs during the replacement project by the local government. It is also expected to improve the safety and medical environment of Chuja-do residents.

X-ray Medical Image Dynamic Range Adjustment Algorithm (엑스선 의료영상의 다이내믹 레인지 조절 알고리즘)

  • Park, Sangwook;Joo, Hui Jin;Sohn, Jeongwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.683-684
    • /
    • 2016
  • 엑스선 영상의 명암 차를 조절하는 다이내믹 레인지 조절 알고리즘은 병변의 부위 크기를 진단하는데 직접적인 영향을 준다. 그러므로 의료 영상을 통한 정확한 진단을 위해 원본 영상의 왜곡없이 적절한 다이내믹 레인지로 조절하는 알고리즘은 의료 영상 획득의 중요한 과정 중 하나이다. 본 논문에서는 엑스선 의료영상의 다이내믹 레인지를 효과적으로 조절하는 알고리즘을 제시한다. 먼저 영상의 히스토그램 중에 최대값에 해당되는 밝기 값을 구한다. 다음으로 해당 밝기 값을 중심으로 적합한 로지스틱 함수를 적용하여 순람표를 만든다. 계산된 순람표를 적용하여 최종 밝기 값을 구하여 의료 진단에 최적인 다이내믹 레인지를 갖는 영상을 획득할 수 있었다.

병원세제 주요문제점과 개선책

  • Jeong, Gi-Seon
    • Journal of the Korean hospital association
    • /
    • v.13 no.11 s.119
    • /
    • pp.9-13
    • /
    • 1984
  • 민간부분의 의존도가 높은 우리나라 병원은 의료보험의 시행과 더불어국민의료에 많은 기여를 하며 발전해오고 있다.그러나 매년 증대되는 의료수요와 함게 발전하는 의료수준을 유지하기 위해서는 계속적인 의료에 대한 투자가 병행되어야만 하는데, 현실적으로 그렇지 못한것이 도한 병원계의 실정이라 하겠다. 본 고는 병원계가 당면한 제반 분제중 특히 병원제세면에 관십을 갖고 병원세제와 관련된 정책적인 주요문제와 개선방향을 중심으로 고찰하고자 한다.

  • PDF

Micrometer Spatial Resolution Imaging System Using Synchrotron X-ray (Synchrotron X-선을 이용한 Micrometer 공간 분해능 영상시스템)

  • 홍진오;정해조;정하규;제정호;김은경;유형식;김희중
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.165-169
    • /
    • 2001
  • 최근 포항 방사광 가속기 연구소에 미세구조 X-선 영상 실험을 위한 5C1 방사광(Synchrtoron Radiation) 빔라인이 건설되었다. 광대역의 에너지 스펙트럼을 가진 방사광 X-선이 물체를 투과한 후 CdWO$_{4}$ scintillator에 의해 가시광선으로 바뀌고, 그 빛을 CCD 카메라로 받아들여 영상을 획득하게 된다. 방사광 X-선은 일반 의료진단용 X-선에 비하여 위상이 일치하고, 평행하며, 그 양이 풍부한 특성들을 갖고 있다. 방사광 영상시스템과 X-선 유방촬영 시스템에서 영상을 획득하여 영상특성들을 비교, 분석하였다. 고-분해능 X-선 시험 패턴(20 line pairs mm$^{-1}$), 유방촬영 팬텀, 파라핀에 고정한 인체 유방암조직과 포르말린에 고정한 인체 유방암조직, 그리고 capillary tube내 micro-bubbles등의 방사광 영상은 기존의 X-선 유방촬영시스템에서 얻은 영상보다 분해능이 뛰어나고 영상질도 우수하였다. 방사광 X-선 영상시스템은 micrometer 공간 분해능 영상을 획득할 수 있어 많은 기초분야의 영상연구와 의료영상분야에서도 활발하게 활용될 것으로 기대된다.

  • PDF

u-헬스케어 서비스에서의 의료정보보호

  • Song, Ji-Eun;Kim, Shin-Hyo;Chung, Myung-Ae
    • Review of KIISC
    • /
    • v.17 no.1
    • /
    • pp.47-56
    • /
    • 2007
  • u-헬스케어 서비스의 발달에 따라 기존의 질병 발생 후에 대응하는 방식의 병원 치료적 패러다임에서 탈피하여 환자가 무선 의료 기기를 휴대하거나 주변 환경에 설치된 의료 장치를 이용하여 일상생활 가운데 건강관리, 질병 예방, 신속한 치료 등의 서비스가 가능해지고 있다. u-헬스케어 서비스가 고도화 될수록 지능화된 의료 센서나 기기에 의한 개인 생체 정보 및 주변 환경 정보에 관한 모니터링이 가능해지고 유무선 네트워크를 통한 건강 정보의 공유가 확대될 것이다. 그러나 u-헬스케어는 개인 건강/의료 정보를 포함한 극히 개인적인 정보를 주로 다루고 있고 유무선 네트워크와 절대적으로 밀접한 연관을 맺고 있으며, 의료 정보 권한과 관련된 다양한 이해 당사자가 존재할 수 있다는 점에서 보안 및 프라이버시 측면에서 다양한 취약점과 위협이 존재할 수 있다. 따라서 안전한 u-헬스케어 서비스 연구 개발을 위해 u-헬스케어의 개요와 특성을 살펴보고, 관련 보안 이슈 및 요구사항을 분석하여 대응 가능한 합리적인 기술적 대안들을 검토코자 한다.

Development of Oriental Medical CRM System based Wire/Wireless for Digital Oriental Hospital (디지털 한방 병원을 위한 유무선기반 한방의료 CRM 시스템 개발)

  • Park, Hong-Jin;Youn, Young-Su
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.131-137
    • /
    • 2007
  • The development of logical and systematical oriental hospital system is very important because most of oriental hospitals are taking pain of the competition's of the hospital and the medical market open. The setup of oriental medical is to enhance medical services and to maximize the efficiency of the management of the hospital. This paper develop the oriental hospital CRM based wire and wireless for digital oriental hospital mixed oriental hospital area and IT technology to maximize the profit the hospital

  • PDF

Algorithm for extracting region of interest in medical images using image processing techniques (영상처리 기법을 이용한 의료 영상에서 관심영역 추출 알고리즘)

  • Cho, Young-bok;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.295-298
    • /
    • 2018
  • The proposed paper proposes an algorithm that automatically extracts the region of interest using image processing techniques for medical images. In general, the robust boundary segmentation technique provides robust and accurate segmentation results in object boundaries with various noise and direction generated during image acquisition through optimal segmentation of the edges considering noise characteristics and directionality in noise images. In this paper, it is possible to apply adaptive filter type and size to the structural information of the image object and apply it to the boundary division of various object objects. In addition, it is possible to divide the boundary between various noise images such as an ultrasound image and an optical image.

  • PDF

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices : Bone Absorptiometric X-ray System (엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Kim, Eun-Rim;Lee, Jun-ho;Lee, Chang-Hyung;Park, Chang Won
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.263-271
    • /
    • 2016
  • The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.