• Title/Summary/Keyword: 의료산업

Search Result 2,165, Processing Time 0.034 seconds

Explicating Personal Health Informatics Experience (퍼스널 헬스케어 디바이스 사용자 경험 연구)

  • Shin, Dong-Hee;Cho, Hoyoun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.550-566
    • /
    • 2017
  • Recent advances in wearable devices and quantified-self movement increase the number of personal informatics application that may cause an concern to health industry and user. In this light, the goal of this study is to identify more effective ways of design and evaluation of personal informatics application for self-tracking and delivering health information to users. For this goal, this study conducted areal-world study that processes such that user can assess, be aware of, and self-reflect on their data and behavior activity. In doing so, this study aims to determine the psychological effects of forms of health feedback (comparative vs. non-comparative) and presentation modes (text vs. image) on users' tendencies toward health conservation. Results from a between-subjects experiment revealed that health information in a comparative and textual format was more effective in encouraging health conservation in participants than identical information presented in a non-comparative and image format. In addition, participants' level of health consciousness emerged as a significant predictor. Through this analysis of quantitative data and inferences, this study make a number of contributions to the user affordance research and its methodology of health informatics study and designing personal informatics application that support user's behavior change in various contexts.

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.

Development and Application of Test Apparatus for Classification of Sealed Source (밀봉선원의 성능시험을 위한 장치 개발 및 적용)

  • Kim, Dong-Hak;Seo, Ki-Seog;Bang, Kyoung-Sik;Lee, Ju-Chan;Son, Kwang-Je
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.1
    • /
    • pp.35-44
    • /
    • 2007
  • Sealed sources have to conducted the tests be done according to the classification requirements for their typical usages in accordance with the relevant domestic notice standard and ISO 2919. After each test, the source shall be examined visually for loss of integrity and pass an appropriate leakage test. Tests to class a sealed source are temperature, external pressure, impact, vibration and puncture test. The environmental test conditions for tests with class numbers are arranged in increasing order of severity. In this study, the apparatus of tests, except the vibration test, were developed and applied to three kinds of sealed source. The conditions of the tests to class a sealed source were stated and the difference between the domestic notice standard and ISO 2919 were considered. And apparatus of the tests were made. Using developed apparatus we conducted the tests for $^{192}Ir$ brachytherapy sealed source and two kinds of sealed source for industrial radiography. $^{192}Ir$ brachytherapy sealed source is classified by temperature class 5, external pressure class 3, impact class 2 and vibration and puncture class 1. Two kinds of sealed source for industrial radiography are classified by temperature class 4, external pressure class 2, impact and puncture class 5 and vibration class 1. After the tests, Liquid nitrogen bubble test and vacuum bubble test were done to evaluate the safety of the sealed sources.

Decision Tree Induction with Imbalanced Data Set: A Case of Health Insurance Bill Audit in a General Hospital (불균형 데이터 집합에서의 의사결정나무 추론: 종합 병원의 건강 보험료 청구 심사 사례)

  • Hur, Joon;Kim, Jong-Woo
    • Information Systems Review
    • /
    • v.9 no.1
    • /
    • pp.45-65
    • /
    • 2007
  • In medical industry, health insurance bill audit is unique and essential process in general hospitals. The health insurance bill audit process is very important because not only for hospital's profit but also hospital's reputation. Particularly, at the large general hospitals many related workers including analysts, nurses, and etc. have engaged in the health insurance bill audit process. This paper introduces a case of health insurance bill audit for finding reducible health insurance bill cases using decision tree induction techniques at a large general hospital in Korea. When supervised learning methods had been tried to be applied, one of major problems was data imbalance problem in the health insurance bill audit data. In other words, there were many normal(passing) cases and relatively small number of reduction cases in a bill audit dataset. To resolve the problem, in this study, well-known methods for imbalanced data sets including over sampling of rare cases, under sampling of major cases, and adjusting the misclassification cost are combined in several ways to find appropriate decision trees that satisfy required conditions in health insurance bill audit situation.

Survey study on the Preference of Dental Medical Personnel for Dental CAD/CAM Milling Machines (치과용 CAD/CAM 밀링기에 대한 치과의료종사자들의 선호도 조사)

  • Song, Eun Sung;Kim, Bongju;Lim, Young-Joon;Lee, Jun Jae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.188-198
    • /
    • 2018
  • Purpose: Recently, according to the development of digital technology, computer aided design/computer aided manufacture (CAD/CAM) system is widely used for fabrication of various dental prostheses in the field of dentistry. This study aims to survey the present state and awareness of CAD/CAM system on domestic dental field, and to supply the advice for the application of the new system. Materials and methods: In this questionnaire survey was conducted for a total of 298 dentists, dental hygienist and dental technicians of the whole country including the dental hospital of Seoul National University for two months from November to December, 2016 through mail. Results: The most important purpose to consider when purchasing a dental CAD/CAM milling machine were the performance of the milling machine (64.43%) and the use of milling machine was the highest with 49.33% of manufacturing for dental prosthesis and customized implant abutment. In addition, more than 60% of respondents answered positively about the purchase of new milling machine if the CAD/CAM milling machine was improved to satisfactory performance. Conclusion: This survey results show that the improved CAD/CAM milling machine would be play an important role in the dental industry in preparation for digitization and the 4th industrial revolution.

Problems and Solutions of Zymography Techniques (자이모그라피 기술의 문제점과 해결)

  • Kang, Dae-Ook;Choi, Nack-Shick
    • Journal of Life Science
    • /
    • v.29 no.12
    • /
    • pp.1408-1414
    • /
    • 2019
  • Enzymes are widely used in industrial applications such as detergents, food, feed production, pharmaceuticals and medical applications and major contributors to clean industrial products and processes. To screen, identify, and characterize the enzymes the zymography techniques are routinely used. The zymography technique is a simple, sensitive, and quantifiable technique that is widely used to detect functional enzymes following electrophoretic separation in sodium dodecyl sulfate (SDS)-polyacrylamide gels. The method is a versatile two-stage technique involving protein separation by electrophoresis followed by the detection of enzyme activity in polyacrylamide gels under non-reducing conditions. It is based on SDS-polyacrylamide gel (PAG) copolymerization with substrates, which are degraded by the hydrolytic enzymes restored in enzyme reaction buffer after the electrophoretic separation. Any kind of biological sample can be applied and analyzed on zymography, including culture supernatants of microbes, plants extracts, blood, tissue culture fluids, enzymes in foods extracts and metaproteome. The advantage of zymography is that it is possible to directly detect the protein with activity on the electrophoretic gel as well as confirm the activity at the nanogram level. Thus, this zymography technology can be applied in various fields. However, these advantages are rather disadvantageous and can often lead to experimental errors. In this review, the advantages, disadvantages, and problem solving of zymography technique are described.

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.227-227
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler(G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 80K를 Heat Load 기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

GVT, Inc.의 HP Series 2단 Gifford-McMahon 극저온 냉동기 성능시험

  • Lee, Dong-Ju;Han, Myeong-Hui;Mun, Jae-Yeong;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.118-118
    • /
    • 2012
  • Cryopump는 반도체 임플란타 공정, OLED분야, 신소재 개발, 표면분석 및 처리, 의료분야, 입자가속기, 핵융합 등 다양한 진공분야에 응용되는 고진공용 극저온펌프이다. 특히 향후로의 산업구조는 디스플레이, 반도체, IT 산업분야로 집중 재편될 것이기에, 이에 따른 핵심제조장비인 고진공 펌프의 수요가 급증할 것으로 판단된다. 그리고 이를 위한 핵심부품과 장비들의 국산화가 시급한 실정이다. 기술적인 측면에서 보자면 GVT는 미국의 Varian과 일본Ebara의 Cryopump 제조기술을 원천으로 한 회사로써 현재는 국내 유일의 G-M 냉동기와 Cryopump 제조기술을 보유한 업체이다. 그리고 최근 오랫동안 정체되었던 관련 기술을 발전시켜 최적화된 한국형 G-M 냉동기 및 이를 장착한 다양한 사이즈의 고성능 Cryopump를 출시하게 되었다. 가장 큰 수확은 Cryopump의 성능을 크게 향상시켰으며 무엇보다 고객맞춤형으로 디자인할 수 있을 정도의 기술력을 확보하게 되었다는 점이다. Cryopump의 성능은 장착되는 Cryocooler (G-M냉동기)의 성능과 밀접한 관련이 있기 때문에 일차로 Cryocooler의 성능을 개선하고 이차로 이를 장착한 Cryopump의 성능을 개선하였다. 본 연구는 일차로 진행된 HP Series 2단 Cryocooler 4가지 모델 중 가장 범용인 HPM 모델과 HPS모델에 대한 제작과 성능시험에 관한 것이다. 이는 각각 기존의 ICP Series 펌프에 장착되던 Expander 535 모델 및 Expander 855 모델에 대한 설계 최적화의 결과물로써 내용은 Cryocooler에 대한 'Typical Performance Test(1st STG와 2nd STG의 온도가 각각의 Stage에 인가되는 Heat Load에 의해 그물망 형태의 그래프가 되도록 수행하는 시험법)'의 절차를 따라 수행되었다. HPM Cryocooler의 성능은 2nd STG Temp. 20K와 1st STG Temp. 80K를 Heat Load기준으로 하였을 경우, 각각 8.2W, 55.0W의 성능을 나타내었고 HPS Cryocooler의 성능은 2nd STG Temp. 20K 와 1st STG Temp. 72K를 Heat Load기준으로 하였을 경우, 각각 14.0W, 90.0W의 성능을 나타내었다. 1st STG Temp.를 72K로 정한 이유는 Power Supply의 용량 한계로 인해 90W이상의 Heat Load를 인가할 수 없었기 때문이다. 만약 성능 그래프의 경향성을 고려하여 1st STG Temp. 80K로 가정한다면, 각각 약 13W, 100W 정도의 성능을 가질 것으로 추정된다. 단, 본 시험에 사용된 Compressor는 GVT의 HC80Plus 모델로 내부에는 Helium용 5HP급 Scroll Type의 Compressor가 장착되어 있으며, 봉입압력 250Psig에 저압 100Psig기준, 65scfm의 유량을 가지는 압축기이다. 압축기와 Cryocooler의 조합은 1:1이었고 시험방법은 Cryocooler에 대한 GVT 자체규정에 따라 진행되었으며 밤과 낮 및 공장전체의 부하변동에 따른 냉각수 온도변화에 따른 펌프의 성능변화는 고려되지 않았다.

  • PDF

Development of T-commerce Processing Payment Module Using IC Credit Card(EMV) (IC신용카드(EMV)를 이용한 T-커머스 결제처리 모듈 개발)

  • Choi, Byoung-Kyu;Lee, Dong-Bok;Kim, Byung-Kon;Heu, Shin
    • The KIPS Transactions:PartA
    • /
    • v.19A no.1
    • /
    • pp.51-60
    • /
    • 2012
  • IC(Integrated circuits)card, generally be named smard card, embedded MPU(Micro Processor Unit) of small-size, memory, EEPROM, Card Operating System(COS) and security algorithm. The IC card is used in almost all industry such as a finance(credit, bank, stock etc.), a traffic, a communication, a medical, a electronic passport, a membership management and etc. Recently, a application field of IC card is on the increase by method for payments of T-commerce, as T-commerce is becoming a new growth engine of the broadcating industry by trend of broadcasting and telecommunication convergence, smart mechanization of TV. For example, we can pay in IC credit card(or IC cash card) on T-Commerce. or we can be provided TV banking service in IC cash card such as ATM. However, so far, T-commerce payment services have weakness in security such as storage and disclosure of card information as well as dropping sharply about custom ease because of taking advantage of card information input method using remote control. To solve this problem, This paper developed processing payment module for implementing TV electronic payment system using IC credit card payment standard, EMV.

A Prospect for Growth and Economic Size of Foods-for-Elderly Industry -Focused on Health Functional Foods and Foods for Special Dietary Uses- (고령친화식품산업의 성장과 규모 전망 -건강기능식품과 특수용도식품을 중심으로-)

  • Jin, Hyun Joung;Woo, Hee Dong
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.4
    • /
    • pp.339-348
    • /
    • 2012
  • The purpose of this study is to predict the economic size of foods-for-elderly market, which will be valuable information for establishing related policy and backup system. After setting the scope of related industry, detailed information for current market situation was investigated and a systematic forecast for market changes in the future was performed. Economic growth, changes in consumer expenditure and economic status of the elderly, current subscription of medical insurance and saving for pension were reflected. In addition, a survey toward related firms was completed and changes in aged population and incidence of chronic disease in the elderly were taken into account. Results show that the annual growth rate of the market was predicted to be the minimum 4.54% through the maximum 8.32% from 2010 to 2025 and its market size was forecasted to be the minimum 7,073 ten million won through the maximum 10,976 ten million won. It is expected that the market of foods-for-elderly will grow rapidly with development of foods technology and fast increase of aged population. Especially, growth of health functional foods and foods for special dietary uses for elderly will be distinguished. However, it seems that related firms are on the hedge, watching current trend of the related industry. This may results in insufficient supply against the demand. Therefore, policy for foods-for-elderly should be introduced and systematically administered, including R&D support, standardization and authentication for foods-for-elderly, construction of related database system.