• Title/Summary/Keyword: 의료기구

Search Result 239, Processing Time 0.023 seconds

Difference of perception of the duties of dental hygienist between dentists and dental hygiene students in an area (일개 지역 치과의사와 치위생학과 학생 간 치과위생사의 업무에 대한 인식의 차이)

  • Hwang, Soo-Jeong;Koong, Hwa-Soo;Lee, Sang-Hoon
    • Journal of Korean Academy of Dental Administration
    • /
    • v.5 no.1
    • /
    • pp.1-12
    • /
    • 2017
  • Although dental hygienists have performed chair-side assisting and other dental cares as well as preventive dental cares in Korea, medical technician law confines duties of dental hygienists as closed narrative. The aim of this study was to investigate difference in perception of duties of dental hygienists in dental clinic between dentists and dental hygiene students. A total of 245 copies of questionnaires were distributed to dentists and students by post-mail. Only 42 dentists and 30 students in an area replied these questionnaires about the present and future duties of dental hygienists after providing written consent. Both groups agreed that intra and extra oral X-ray taking, education about oral health behavior, instruction after dental treatment, chair-side assisting, consulting for patients, scaling, initial impression taking, management of dental materials and equipment, sterilization of equipment, and receiving dental bills are duties of dental hygienists. However, they had different perceptions about various dental treatments as duties of dental hygienists even if they were under instructions of a dentist, including infiltration anesthesia, filling in cavity, intramuscular injection, FC change, canal irrigation, orthodontic treatment including separating, ligature bracket bonding and removing, setting crown and bridge, making individual, removing implant screw, and so on. These findings demonstrated that there were different perceptions about duties of dental hygienists between dentists and dental hygiene students, especially on dental treatment.

The Implementation Status of Dental Treatment Infection Control Standards of Dental Hygienists (치과위생사의 치과진료 감염방지기준에 관한 연구)

  • Yoo, Ha-Na;Kang, Kyung-Hee
    • Journal of Digital Convergence
    • /
    • v.11 no.12
    • /
    • pp.649-656
    • /
    • 2013
  • This study was conducted to find out about the implementation status of dental treatment infection control standards of dental hygienists. The subjects of research were the dental hygienists working at dentist offices in Chungnam, Cheonan-si using self-input method from July 25th, 2012 to August 1st 2012. The collected data was analyzed after computerized statistical processing using SPSS 18.0. For hepatitis B vaccination, the results were high with 75.0% of answers being 'yes' or auto-active immunity, but for the latest hepatitis vaccination period showed highest results in '5 years or more ago' with 48.0%. Although 93.0% answered that vaccination was important, the percentage of replies that they had vaccination education was relatively low with 41.0%. For the use of personal protection tools the use of protective goggles was low compared to the use of masks and medical gloves. The percentage of subjects that answered that they always wash their hands before treatment was relatively low with 56.0% compared to 82.0% of subjects that answered that they always washed their hands after treatment. Dental treatment equipment washing before sterilization, use of packing and re-sterilization of tools with damaged packing showed high results for 'yes', but the ratio of subjects that answered 'no' to water line management was low with 39%.

Biomechanical Analysis and Evaluation Technology Using Human Multi-Body Dynamic Model (인체 다물체 동역학 모델을 이용한 생체역학 분석 및 평가 기술)

  • Kim, Yoon-Hyuk;Shin, June-Ho;Khurelbaatar, Tsolmonbaatar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.494-499
    • /
    • 2011
  • This paper presents the biomechanical analysis and evaluation technology of musculoskeletal system by multi-body human dynamic model and 3-D motion capture data. First, medical image based geometric model and material properties of tissue were used to develop the human dynamic model and 3-D motion capture data based motion analysis techniques were develop to quantify the in-vivo joint kinematics, joint moment, joint force, and muscle force. Walking and push-up motion was investigated using the developed model. The present model and technologies would be useful to apply the biomechanical analysis and evaluation of human activities.

Health Effects Due to Air Pollution (대기오염과 건강)

  • Peak Do Myung
    • KOREAN ASSOCIATION OF OCCUPATIONAL HEALTH NURSES
    • /
    • v.8 no.2 s.28
    • /
    • pp.10-18
    • /
    • 2001
  • 우리나라 대기오염의 수준은 지난 90년대 초반 이후 아황산가스와 총부유분진의 농도가 감소하고, 대신 오존과 이산화질소의 농도가 증가하면서 점차 다른 선진국에서 경험하는 대기오염현황을 보이고 있다. 한편 PM10과 PM2.5와 같은 미세분진의 경우 그 측정기간이 짧고 자료가 제한적이지만, 일부 지역에서 증가추세를 보이고 있으며, 그 수준을 비교하였을 때 현재 선진국에서 책정한 미세분진의 규제농도를 훨씬 상회하는 것으로 판단된다. 대기오염으로 인한 건강영향으로는 급성으로 고농도에 수 시간에서 수 일 동안 노출되는 경우 폐기능의 저하, 심박동의 변화, 그리고 신체내 염증물질의 증가 등 인체 기능의 변화가 보고되고 있으며, 기존에 폐장질환이나 심혈관질환을 앓고 있는 사람들의 경우 증세의 악화와 의료이용의 증가 등을 경험하거나 더 나아가 사망에 이르러 수명이 단축되는 것이 보고되고 있다. 급성노출의 경우 미세분진 PM10 10 $\mu$m/m3 당 전체 사망률이 0.5-1$\%$ 가량 증가하는 것으로 보고되며, 만성노출을 조사한 코호트 연구에 근거하는 경우 대기오염에 노출되는 전체 인구에 있어 PM2.5 1 $\mu$m/m3 당 1개월의 수명이 단축되는 것으로 추정되고 있다. 아직 대기오염으로 인한 건강영향의 기전이 전부 밝혀진 것은 아니지만, 일부 연구에서 대기오염물질 중에서 전이금속의 역할이 보고되고 있으며, 대기오염에 노출되면서 기관지, 폐포 및 혈액 등에서 염증매개물질의 분비 및 확산 그리고 심장을 비롯한 각 장기 기능의 변화가 보고되고 있다. 한편 이러한 변화들이 증세와 건강상의 비가역적 변화를 야기하는데 있어 대기오염 수준의 역치는 없는 것으로 판단되고 있다. 이러한 대기오염의 영향에 대한 개인수준의 해결책으로서는 자동차 사용의 절제 및 개인적인 쓰레기 소각의 자제 등 오염원 발생의 감소와 함께 대기오염 수준에 따른 증세 및 투약의 적절한 조절과 신체 활동의 조절을 통하여 오염원을 회피하는 것이 강조되어야 하며, 또한 흡연 특히 실내흡연의 금지와 실내 주방기구 및 난방기구의 관리 등이 구체적으로 제시될 수 있다. 마지막으로 대기오염물질들이 신체에 들어와 산화제로 작용하는 만큼, 식품을 통한 항산화제의 섭취가 일반적인 건강관리 수준에서라도 반드시 강조되어야 할 것이다.

  • PDF

Three-dimensional Locomotion and Drilling Microrobot Using Electromagnetic Actuation System (전자기 구동 시스템을 이용한 마이크로로봇의 3차원 이동 및 드릴링)

  • Li, Jie;Choi, Hyun-Chul;Cha, Kyoung-Rae;Jeong, Se-Mi;Park, Jong-Oh;Park, Suk-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.12
    • /
    • pp.1573-1578
    • /
    • 2011
  • In this study, a novel electromagnetic microrobot system with locomotion and drilling functions in threedimensional space was developed. Because of size limitations, the microrobot does not have actuator, battery, and controller. Therefore, an electromagnetic actuation (EMA) system was used to drive the robot. The proposed EMA system consists of three rectangular Helmholtz coil pairs in x-, y- and z-axes and a Maxwell coil pair in the z-axis. The magnetic field generated in the EMA coil system could be controlled by the input current of the EMA coil. Finally, through various experiments, the locomotion and drilling performances of the proposed EMA microrobot system were verified.

Comparison of Three Supraglottic Airway Devices in Neutral and Cervical Neck Collar Position (융복합적 기술이 적용된 성문위기구들의 삽관용이성 비교)

  • Tak, Yang-Ju
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.369-375
    • /
    • 2016
  • Purpose of this study was to compare the easiness of insertion of three Supraglottic airway devices(SADs) in a neutral and cervical neck collar position in a manikin setting. Three different SADs-Laryngeal Mask Classic (LMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. Thirty nine emergency medical technicians (EMTs) who are working in Korea 119 rescue services were taught briefly about the use of the LMA, I-gel and SLIPA in a manikin setting. The time to effective ventilation was shorter in I-gel ($10.5{\pm}2.2$, $11.4{\pm}5.7$) and SLIPA ($12.3 {\pm}5.1$, $12.0{\pm}6.8$) than LMA ($17.2{\pm}3.2$, $18.5{\pm}5.5$) in a neutral and cervical neck collar position, respectively(p<0.05). There was no difference between head positions in each of the airways. In conclusion, in the speed of insertion, I-gel and SLIPA were superior to LMA in the neutral and cervical collar setting of a manikin.

Effect of a Elderly Walker on Joint Kinematics and Muscle Activities of Lower Extremities Using a Human Model (인체 모델을 이용한 노인 보행기의 하지관절 기구학과 근활성에 미치는 영향)

  • Shin, Jun-Ho;Kim, Yoon-Hyuk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1243-1248
    • /
    • 2011
  • The purposes of this study were to develop a dynamic model of a human and to investigate the effect of a walker on an elderly subject's motions, such as sit-to-stand (STS) motion and normal gait, by using this model. A human model consisting of 15 segments and 14 joints was developed, embedded in $RecurDyn^{TM}$, and connected through a Simulink$^{(R)}$ interface with collected motion data. The model was validated by comparisons between joint kinematic results from inverse dynamics (Matlab$^{(R)}$-based in-house program) and from $RecurDyn^{TM}$ simulation during walking. The results indicate that the elderly walker induced a longer movement time in walking, such that the speed of joint flexion/extension was slower than that during a normal gait. The results showed that the muscle activities of parts of the ankle and hamstring were altered by use of the elderly walker. The technique used in this study could be very helpful in applications to biomechanical fields.

Comparative Study of Target Genes and Protocols by Country for Detection of SARS-CoV-2 based on Polymerase Chain Reaction (PCR) (중합효소 연쇄반응 기반의 코로나-19 바이러스 검출법에 대한 국가별 목표 유전자 및 프로토콜 비교 연구)

  • Kim, Jin-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.465-474
    • /
    • 2021
  • Corona-19, a disease caused by 'Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2)', was declared a global pandemic by the World Health Organization (WHO) in March 2020, and a real-time polymerase chain reaction test is performed as a diagnostic test for screening and confirmation in most countries. However, not only the target genes and protocols differ by countries, but also the procedures for reading the diagnosis results are diverse, so the criteria for confirmed patients differ by country. Therefore, in this review, we discussed the target genes, test techniques, and diagnostic criteria for each country notified by WHO. And the specificity and sensitivity, limits of detection, positive and negative controls, false positive bacteria candidates, and specimens, and the specifics of the control setting were also described. In addition, the characteristics of Korea's test were compared to each country's one. Finally, in order to obtain the same diagnosis result for SARS-CoV-2 in the future, standardized diagnosis methods and result interpretations for Corona-19 diagnosis were proposed.

Development of Biopsy Assist Device on Computed Tomography Using 3D Printing Technology (3D 프린팅 기술을 이용한 전산화단층영상 기반 조직 생검 보조기구 개발)

  • Jeong-Wan Kim;Youl-Hun Seoung
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.151-157
    • /
    • 2023
  • The purpose of this study was to develop an assist device that could correct and support patient position during biopsy on computed tomography (CT) using 3D printing technology. The development method was conducted in the order of 3D design, 3D output, intermediate evaluation for product, final assist device evaluation. The 3D design method was conducted in the order of prior research data survey, measurement, primary modeling, 3D printing, output evaluation, and supplementary modeling. The 3D output was the 3D printer (3DWOX 2X, Sindoh, Korea) with additive manufacturing technology and the polylactic acid (PLA) materials. At this time, the optimal strength was evaluated to infill degree of product as the 3D printing factors into 20%, 40%, 60%, and 80%. The intermediate evaluation and supplementation was measured noise in the region of interest (ROI) around the beam hardening artifact on the CT images. We used 128-channel MDCT (Discovery 75 HD, GE, USA) to scan with a slice thickness of 100 kVp, 150 mA, and 2.5 mm on the 3D printing product. We compared the surrounding noise of the final 3D printing product with the beginning of it. and then the strength of it according to the degree of infill was evaluated. As a result, the surrounding noise of the final and the early devices were measured at an average of 3.3 ± 0.5 HU and 7.1 ± 0.1 HU, respectively, which significantly reduced the noise of the final 3D printing product (p<0.001). We found that the percentage of infill according to the optimal strength was found to be 60%. Finally, development of assist devices for CT biopsy will be able to minimize artifacts and provide convenience to medical staff and patients.

Development of gripping force and durability test standard for myoelectric prosthetic hand (근전전동의수의 파지력 및 내구성 시험 표준 개발)

  • Gook Chan Cha;Suk-Min Lee;Ki-Won Choi;Sangsoo Park
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.393-399
    • /
    • 2023
  • Upper limb amputees wear an upper limb prosthesis for both aesthetic purposes and functional necessity, and in particular, in the case of amputee with both hands, it is essential to wear a myoelectric prosthetic hand capable of gripping action. The prosthetic hand operated by the EMG signal of the remaining muscles is a public insurance benefit item of the Industrial Accident Compensation Insurance, and test method standards are needed to be developed for the safety of the user and the effectiveness of the product performance. In this study, we developed systems for measuring the gripping force of myoelectric hand prosthesis by a load cell and for durability test of the prosthesis over repeated use with a proximity sensor, and propose a test method standard. Since the international test method standard has not yet been established, it is expected that Korea will be able to play a leading role in this standardization field in the future.