• Title/Summary/Keyword: 응력회복

Search Result 176, Processing Time 0.023 seconds

Flexural Behavior of Concrete Beams Reinforced with Fe based Shape Memory Alloy Bar (철계-형상기억합금 바로 제작된 콘크리트 보의 휨 거동)

  • Hong, Ki-Nam;Yeon, Yeong-Mo;Ji, Sang-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.67-76
    • /
    • 2020
  • This paper reports an experimental study to evaluate the flexural behavior of concrete beams reinforced using Fe based shape memory alloy (Fe-SMA) bars. For the experiment, a concrete beam of 200mm×300mm×2,200mm was produced, and a 4% pre-strained Fe-SMA bar was used as a tensile reinforcement. As experimental variables, type of tensile reinforcement (SD400, Fe-SMA), reinforcement ratio (0.2, 0.39, 0.59, 0.78), activation of Fe-SMA (activation, non-activation), and joint method of Fe-SMA bar (Continuous, welding, coupler) were considered. The electric resistance heating method was used to activate the Fe-SMA bar, and a current of 5A/㎟ was supplied until the specimen reached 160℃. After the upward displacement of the specimen due to the camber effect was stabilized, a three-point flexural loading experiment was performed using an actuator of 2,000 kN capacity. As a result of the experiment, it was found that the upward displacement occurred due to the camber effect as the Fe-SMA bar was activated. The specimen that activated the Fe-SMA bar had an initial crack at a higher load than the specimen that did not activate it. However, as with general prestressed concrete, the effect of the prestress by Fe-SMA activation on the ultimate state of the beam was insignificant.

Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report (하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Min-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Jo, Yong-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.1
    • /
    • pp.71-79
    • /
    • 2022
  • Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.

A Methodology for Quality Control of Railroad Trackbed Fills Using Compressional Wave Velocities : II. Verification of Applicability (압축파 속도를 이용한 철도 토공노반의 품질관리 방안 : II. 적용성 검증)

  • Park, Chul-Soo;Mok, Young-Jin;Hwang, Seon-Keun;Park, In-Beom
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.9
    • /
    • pp.57-66
    • /
    • 2009
  • In the preliminary investigation (Park et al., 2009), the use of compressional wave velocity and its measurement techniques were proposed as a new quality control measure for trackbed fills. The methodology follows exactly the same procedure as the density control, except the density being replaced by the compressional wave velocity involving consistently with resilient modulus of design stage. The specifications for the control also include field compaction water content of optimum moisture content ${\pm}2%$ as well as the compressional wave velocity. In this sequel paper, crosshole and resonant column tests were performed as well direct-arrival method and laboratory compressional wave measurements to verify the practical applicability of a methodology far the new quality control procedure based upon compressional wave velocity. The stress-modified crosshole results reasonably well agree with the direct-arrival values, and the resonant column test results also agree well with the field crosshole results. The compressional wave velocity turned out to be an excellent control measure for trackbed fills both in the theoretical and practical point of view.

Bulk Properties of Red Pepper Powder by Drying Method and Variety (품종과 건조방법에 따른 고춧가루의 집단 특성)

  • Kang, Yu-Ri;Lee, Sang-Hoon;Kim, Hyun-Young;Woo, Koan-Sik;Hwang, In-Guk;Hwang, Young;Yoo, Seon-Mi;Kim, Haeng-Ran;Kim, Hae-Young;Lee, Jun-Soo;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.9
    • /
    • pp.1320-1325
    • /
    • 2012
  • This study investigated the bulk properties of red pepper powders according to drying method and variety. Bulk density, compressive characteristics, irrecoverable work, dynamic angle, and stress relaxation were investigated. Loose bulk density ranged between 0.420 $g/cm^3$ for Cheongyang cultivar and 0.427 $g/cm^3$ for Hanbando cultivar by hot-air drying. The highest tapped bulk density was 0.586 $g/cm^3$ for Hanbando cultivar by far-infrared drying and the lowest value was 0.523 $g/cm^3$ for Hanbando cultivar by sun drying. Hausner ratio reached a maximum value of 1.370 for Hanbando cultivar by far-infrared drying. Compressibility ranged between 0.0016 for Cheongyang cultivar by sun drying and 0.0023 for Hanbando cultivar by far-infrared drying. Compression ratio reached a maximum value of 1.032 for Hanbando cultivar by hot-air drying. Dynamic angle of repose ranged between 37.47 and $42.97^{\circ}$. Irrecoverable work ranged between 76.0 and 81.7%. Relaxation reached a maximum value of 24.31% for Cheongyang cultivar by far-infrared drying.

A Study on the Stress Distribution of Condylar Region and Edentulous Mandible with Implant-Supported Cantilever Fixed Prostheses by using 3-Dimensional Finite Element Method (임플란트 지지 캔틸레버 고정성 보철물 장착시 과두와 하악골의 응력 분포에 관한 3차원 유한요소법적 연구)

  • Kim, Yeon-Soo;Lee, Sung-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.4
    • /
    • pp.283-305
    • /
    • 2001
  • The purpose of this study was to analyze the stress distribution of condylar regions and edentulous mandible with implant-supported cantilever prostheses on the certain conditions, such as amount of load, location of load, direction of load, fixation or non-fixation on the condylar regions. Three dimensional finite element analysis was used for this study. FEM model was created by using commercial software, ANSYS(Swanson, Inc., U.S.A.). Fixed model which was fixed on the condylar regions was modeled with 74323 elements and 15387 nodes and spring model which was sprung on the condylar regions was modeled with 75020 elements and 15887 nodes. Six Br${\aa}$nemark implants with 3.75 mm diameter and 13 mm length were incorporated in the models. The placement was 4.4 mm from the midline for the first implant; the other two in each quardrant were 6.5 mm apart. The stress distribution on each model through the designed mandible was evaluated under 500N vertical load, 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. The load points were at 0 mm, 10 mm, 20 mm along the cantilever prostheses from the center of the distal fixture. The results were as follows; 1. The stress distribution of condylar regions between two models showed conspicuous differences. Fixed model showed conspicuous stress concentration on the condylar regions than spring model under vertical load only. On the other hand, spring model showed conspicuous stress concentration on the condylar regions than fixed model under 250N horizontal load linguobuccally, buccal 20 degree 250N oblique load and buccal 45 degree 250N oblique load. 2. Fixed model showed stress concentration on the posterior and mesial side of working and balancing condylar necks but spring model showed stress concentration on the posterior and mesial side of working condylar neck and the posterior and lateral side of balancing condylar neck under vertical load. 3. Fixed model showed stress concentration on the posterior and lateral side of working condylar neck and the anterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior sides of working and balancing condylar necks under horizontal load linguobuccally. 4. Fixed model showed stress concentration on the posterior side of working condylar neck and the posterior and lateral side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 20 degree oblique load. 5. Fixed model showed stress concentration on the anterior and lateral side of working condylar neck and the posterior and mesial side of balancing condylar neck but spring model showed stress concentration on the anterior side of working condylar neck and the anterior and lateral side of balancing condylar neck under buccal 45 degree oblique load.. 6. The stress distribution of bone around implants between two models revealed difference slightly. In general, magnitude of Von Mises stress was the greatest at the bone around the most distal implant and the progressive decrease more and more mesially. Under vertical load, the stress values were similar between implant neck and superstructure vertically, besides the greatest on the distal side horizontally. 7. Under horizontal load linguobuccally, buccal 20 degree oblique load and buccal 45 degree oblique load, the stress values were the greatest on the implant neck vertically, and great on the labial and lingual sides horizontally. After all, it was considered that spring model was an indispensable condition for the comprehension of the stress distributions of condylar regions.

  • PDF

Evaluation of the Curvature Reliability of Polymer Flexible Meta Electronic Devices based on Variations of the Electrical Properties (전기적 특성 변화를 통한 고분자 유연메타 전자소자의 곡률 안정성 평가)

  • Kwak, Ji-Youn;Jeong, Ji-Young;Ju, Jeong-A;Kwon, Ye-Pil;Kim, Si-Hoon;Choi, Doo-Sun;Je, Tae-Jin;Han, Jun Sae;Jeon, Eun-chae
    • Applied Chemistry for Engineering
    • /
    • v.32 no.3
    • /
    • pp.268-276
    • /
    • 2021
  • As wireless communication devices become more common, interests in how to control the electromagnetic waves generated from the devices are increasing. One of the most commonly used electromagnetic wave control materials is magnetic one, but due to the features that make the product heavy and thick when applied to the product, it is difficult to use them in curved electronic devices. Therefore, a polymer flexible meta electronic device has been presented to sort out the problem, which is thin and can have various curvatures. However, it requires an additional evaluation of curvature reliability. In this study, we developed a method to predict electromagnetic wave control characteristics through the resistance/length of the conductive ink line patterns of polymer flexible meta electronic devices, which is inversely proportional to the electromagnetic wave control characteristics. As the radius of curvature decreased, the resistance/length increased, and there was little variations with the duration times of curvature. We also found that both permanent and recoverable changes along with the removal of curvature were occurred when the curvature was applied, and that the cause of these changes was newly created vertical cracks in the conductive ink line pattern due to the tensile stress applied by applying curvature.