• Title/Summary/Keyword: 음압법

Search Result 95, Processing Time 0.023 seconds

Generation of Time Series Data from Octave Bandwidth SPL of Acoustic Loading Using Interpolation Method (보간법을 이용한 옥타브 밴드폭 음향 하중 SPL의 시계열 데이터 생성)

  • Go, Eun-Su;Kim, In-Gul;Jeon, Minhyeok;Cho, Hyun-Jun;Park, Jae-Sang;Kim, Min-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Thermal protection system structures such as double-panel structures are used on the skin of the fuselage and wings to prevent the transfer of high heat into the interior of an high supersonic/hypersonic aircraft. The thin-walled double-panel skin can be exposed to acoustic loads by high power engine noise and jet flow noise, which can cause sonic fatigue damage. In order to predict the fatigue life of the skin, the octave bandwidth SPL should be calculated as narrow bandwidth PSD or acoustic load history using interpolation method. In this paper, a method of converting the octave bandwidth SPL acoustic load into a narrow bandwidth PSD and reconstructed acoustic load history was investigated. The octave bandwidth SPL was converted to the narrow bandwidth PSD using various interpolation methods such as flat, log and linear scale, and the probabilistic characteristics and fatigue damage results were compared. It was found that average error of fatigue damage index by the log scale interpolation method was relatively small among three methods.

Filtering & Cridding Algorithms for Multibeam Echo Sounder Data based on Bathymetry (수심에 기반한 멀티빔 음향 측심 필터와 격자 대표값 선정 알고리즘)

  • 박요섭;김학일
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.260-265
    • /
    • 1999
  • 멀티빔 음향측심기(Multibeam Echo Sounder)는 기존의 단빔 음향측심기(Singlebeam Echo Sounder)와 달리 탐사선 진행방향의 수직(Crosstrack)으로 해저면을 주사(Swath)하여, 한 번의 송수신(Ping)으로 다중의 빔 자료 - 수심, 후방산란된 음압(Backscattered Amplitude), 사이드 스캔 소나(Side Scan Sonar) 자료 - 를 취득하는 장비이다. 멀티빔 음향 측심기를 이용한 해저면 탐사의 경우, 수심이 변함에 따라 주사폭(Swath width)이 변화하고, 각 빔의 수평 해상도(Footprint)는 수심과 더불어 빔폭(Beam width)에 의하여 동적으로 변화한다. 멀티빔 음향 측심기는 해저면을 전역탐사 할 수 있을 뿐만 아니라, 연속된 음향 탐사를 통하여 이웃한 핑 사이에 발생하는 전방중첩영역(Endlap)과 이웃 측선(Trackline)을 따라 겹쳐지는 측방중첩영역(Sidelap)의 자료들을 이용하여 멀티 뎀 자료들의 전반적인 정확도 및 신뢰도를 평가할 수 있다. 본 논문은 수로 측량(Hydrographic Survey)에서 사용되는 멀티빔 음향 측심기를 운영하여 얻어진 측심 자료를 처리하는 알고리즘 개발에 관한 연구이다. 본 논문에서는 L3사의 Sea Beam 2100 벌티빔 음향 측심기를 대상으로, 멀티빔의 측심 원리와 해저 지형에 대한 일반적 이해를 통하여 획득된 측심 자료의 통계적 특성을 파악하고, 오측심된 수심 자료를 제거하는 방법을 제안하며, 측심 구간의 대표격자 크기를 결정하는 기준을 제시한다. 또한, 항공원격탐사에서 고도 추정시 사용되고 있는, 평균보간법, 가중평균 보간법과, 본 논문에서 제안하는 격자 대표값 선정 알고리즘(Gridding Algorithms)의 결과를 비교하고, 최종적으로 얻어지는 해저 수치지형모델(DEM, Digital Elevation Model)과 후방산란 영상을 제시한다. 빠른 한지형잔디들이 지표면을 피복하도록 하고 여름의 고온기와 장마시기에는 뿌리전단력이 우수한 이러한 초종들로 지표면이 피복되도록 하는 것이 이상적이라 생각된다. 4. 혼파처리간의 토사유출량을 비교한 결과 토사 유출 억제효과는 한지형과 나지형잔디들의 혼합형(MixtureIII)과 자생처리구(MixtureV), Italian ryegrass와 자생식물의 혼합형(MixtureIV)등에서 비교적 낮은 수치를 토사유출량을 기록하였다. 이러한 결과는 자생식물들이 비록 초기생육속도는 외래도입초종에 떨어지지만 토사유출의 억제효과면에서는 이들 외래초종에 필적할 수 있음을 나타낸다고 할 수 있겠다.중량이 약 115kg/$m^2$정도로 나타났다.소 들(환경의 의미, 사람의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$순응$\lrcorner$$\ulcorner$표현$\lrcorner$의 성격과 형태를 외형상으로 더욱이 공간상에서는 뚜렷하게 경계

  • PDF

Low Frequency Characteristic of Seoul Subway Noise (서울지하철의 저주파소음 특성)

  • Jung, Sung-Soo;Shin, Su-Hyun;Kim, Ho-Chul;Lee, Woo-Seop
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.11
    • /
    • pp.1193-1197
    • /
    • 2005
  • The low frequency noise below 200 Hz, including inaudible infra-sound, is known to affect human physiology ; circulation, respiration, nerve, endocrine, etc. Legislation has been introduced in several countries regarding evaluation guideline and measurement method of low frequency noise. In this work, low frequency characteristics of the Seoul subway transportation system was investigated in terms of the noise level and spectrum in the interior of running passenger car and the subway station. The interior sound pressure level of the passenger car was between 60 and 105 dB in the frequency range of $1{\sim}200\;Hz$ and varied with car speed. The marked sound pressure level peak at 8 Hz, infra-sound, observed for the most of Lines is shown to correspond to the resonance frequency of passenger car. The level of station platform noise was lower than the interior noise of running car because of the lower speed at arriving/departure. The results indicated that the interior noise level of running passenger car was inside the oppressive feeling region, proposed by Ochiai, in the frequency range of $20{\sim}80\;Hz$ which makes a little concern.

Simulation for application of pumping-and-treatment system to the recovery of non-aqueous phase liquids (NAPLs) at and below the water table (토양의 포화지대에 분포하는 고밀도비수상액체(DNAPL)와 저밀도비수상액체(LNAPL)의 펌핑 제거공정에 대한 모사)

  • 김주형;이종협
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.51-61
    • /
    • 1997
  • The objective of this study is to evaluate the feasibility of Pumping-and-Treatment system (PTS) for remediation of the saturated zones contaminated with NAPLs. A simulation is carried out for the removal of DNAPLs (denser-than-water non-aqueous phase liquids) and LNAPLS (lighter-than-water non-aqueous phase liquids) distributing at and below the water table. In the study, LNAPL and DNAPL are assumed to be n-hexane and 1,1-dichloroacetone, respectively. The model system studied consists of four heterogeneous soil layers with different permeabilities. Groundwater flows through the bottom layer and a pumping well is located under the initial water table. The time-driven deformation of the water table and removal efficiency of contaminants are estimated after vacuum application to the inlet of the well. In the calculation, FVM (Finite Volumetric Method) with SIMPLEC algorithm is applied. Results show that removal efficiencies of both DNAPL and LNAPL are negligible for the first 5 days after the PTS operation. However, when the cone-shape water table is formed around the inlet of the pumping well, the rapid removal rate is obtained since NAPLs migrate rapidly through the curvature of the water table. The removal efficiency of DNAPL is estimated to be higher than that of LNAPL due to the gravity. The results also show that the fluctuation or cone-shaped depression of the water table enhances the removal efficiency of NAPLs in saturated zones. The simulation results could provide a basis of the PTS design for the removal of NAPLs in saturated zones.

  • PDF

A Study on Characteristics of Airborne Asbestos Concentrations at Demolition Sites and Surrounding Areas of Asbestos Containing Buildings in Seoul (서울시내 건축물 석면해체·제거 사업장 및 주변에서의 공기 중 석면농도 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Kim, Iksoo;Eo, Soomi;Jung, Kweon;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.434-441
    • /
    • 2014
  • This study is purposed to measure airborne asbestos concentrations at demolition sites and surrounding areas of asbestos containing buildings in Seoul and examine whether the measurement results correspond with allowable exhaust standard for asbestos of the Asbestos Safety Control Act. The airborne asbestos concentrations for 37 sites were below the detection limit ($7fiber/mm^2$) in 101 (35%) out of 288 samples. The whole average airborne asbestos concentration in 37 sites was $0.003{\pm}0.002f/cc$(max 0.0013 f/cc) and almost the whole airborne asbestos concentrations were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act. So possibility of asbestos exposure is not yet a major concern at current levels for sites demolished of asbestos containing buildings in Seoul. Looking at each sampling point, the average airborne asbestos concentrations in boundary line of site, entrance of sanitation, around the workplace (in), around the workplace (out), negative pressure units, storage area for waste, outlet for waste and residential area of residents were respectively $0.002{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.005{\pm}0.004f/cc$, $0.005{\pm}0.003f/cc$ and $0.003{\pm}0.002f/cc$. As a result, all sampling points of study were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act.