• Title/Summary/Keyword: 윤활마모

Search Result 289, Processing Time 0.025 seconds

Friction Behavior of Oil-enriched Nanoporous Anodic Aluminum Oxide Film (오일 함침된 나노 기공 산화알루미늄 필름의 마찰 거동)

  • Kim, Hyo-Sang;Kim, Dae-Hyun;Hahn, Jun-Hee;Ahn, Hyo-Sok
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.193-197
    • /
    • 2011
  • Friction behavior of nanoporous anodic aluminum oxide(AAO) film was investigated. A 60 ${\mu}m$ thick AAO film having nanopores of 45 nm diameter with 105 nm interpore-diatance was fabricated by mild anodization process. The AAO film was then saturated with paraffinic oil. Reciprocating ball-on-flat sliding friction tests using 1 mm diameter steel ball as the counterpart were carried out with normal load ranging from 0.1 N to 1 N in an ambient environment. The morphology of worn surfaces were analyzed using scanning electron microscopy. The friction coefficient significantly increased with the increase of load. The boundary lubrication layer of paraffinic oil contributed to the lower friction at relatively low load (0.1 N), but it is less effective at high load (1 N). Plastic deformed layer patches were formed on the worn surface of oil-enriched AAO at relatively low load (0.1 N) without evidence of tribochemical reaction. On the other hand, thick tribolayers were formed on the worn surface of both oil-enriched and as-prepared AAO at relatively high load (1 N) due to tribochemical reaction and material transfer.

Tribological Characteristics of Phosphorated Starch Based Electrorheological Fluid (인산화 전분 ER 유체의 트라이볼로지 특성)

  • Jang, Min-Gyu;Lee, Chul-Hee;Choi, Jea-Young;Sohn, Jung-Woo;Choi, Seung-Bok
    • Tribology and Lubricants
    • /
    • v.26 no.1
    • /
    • pp.7-13
    • /
    • 2010
  • This experimental study presents tribological characteristics under boundary lubrication contacts associated with electrorheolocal (ER) fluid. ER fluid is prepared by using phosphorated starch particles and silicone oil. Experimental apparatus of tribological tester is designed and constructed to evaluate tribological characteristics of pin specimens. Wear tests under boundary lubrication of ER fluid are experimentally performed under consideration of several operational factors such as normal load, sliding distance, sliding speed and specimen materials: steel, copper and aluminum. After wear test, microscopic surface changes of the worn pin specimens are analyzed in order to investigate measured wear characteristics by using the scanning electron microscope (SEM) as well as surface profilometer. In addition, the chemical wear characteristics are investigated by using energy dispersive x-ray spectroscopy (EDS). Moreover, friction coefficient measurements under different materials of pin specimens are conducted for the tribological investigations. In order to verify the effect of starch phosphate particles in ER fluid, the wear test results with ER fluid are compared with test results with only silicone oil. The results clearly present that the phosphorated starch based ER fluid shows the stabilized wear as well as friction characteristics after run-in operations, but the wear rate under ER fluid is increased.

A Study of the Life Test of Hydraulic Pump Driving Gear Box for the Large Excavator (초대형 굴삭기용 유압펌프 구동 기어박스의 수명시험에 관한 연구)

  • Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.211-216
    • /
    • 2015
  • Large hydraulic excavator weighted 90 tons used the several pumps installed in parallel to use the hydraulic pump driving gearbox to improve fuel consumption by improving the energy efficiency of the hydraulic system. Gearbox connected to hydraulic pump supply the mechanical output to the high pressure and low pressure pump to be supplied by torque and rotation, which are the mechanical power, through a input shaft connected to large size engine of the excavator. So, gearbox connected to hydraulic pump is same as main artery in the human body and is required long life because it operates the hydraulic pump continuously during operating the engine. This study had used oil contamination analysis method to check the wear characteristics of the gearbox and frequency response characteristic analysis method to check the failure of the teeth failures of gearbox, while the test equipment adopted by the electrical feedback method to reduce the energy consumption was operating for the life assessment, in which the required power was 600 kW input power.

Wear Of Dental Restorative Composite Resins Cured by Two Different Light Sources (치아 충전용 복합레진의 광중합 광원 종류에 따른 마멸 비교)

  • Kim H.;Lee K.Y.;Park S. H.;Jung I. Y.;Jeon S. B.
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.350-354
    • /
    • 2004
  • In this study, the wear characteristics of five different dental composite resins cured by conventional halogen light and LED light sources were investigated. Five different dental composite resins of Surefil, Z100, Dyract AP, Fuji II LC and Compoglass were worn against a zirconia ceramic ball using a pin-on-disk type wear tester with 15 N contact force in a reciprocal sliding motion of sliding distance of 10 mm/cycle at 1Hz under the room temperature dry condition. The wear variations of dental composite resins were linearly increased as the number of cycles increased. It was observed that the wear resistances of these specimens were in the order of Dyract AP > Surefil > Compoglass > Z100 > Fuji II LC. On the morphological observations by SEM, the large crack formation on the sliding track of Fuji ?LC specimen was the greatest among all resin composites. Dyract AP showed less wear with few surface damage. There is no significant difference in wear performance between conventional halogen light curing and light emitting diodes curing sources. It indicates that a light emitting diodes (LED) source can replace a halogen light source as curing unit for composite resin restorations.

  • PDF

Thermohydrodynamic Analysis and Pad Temperature Measurement of Tilting Pad Journal Bearing with Worn Pad (표면이 마모된 틸팅 패드 저널베어링의 열윤활 해석 및 온도 측정)

  • Lee, Donghyun;Sun, Kyungho;Kim, Byungock;Kang, Donghyuk
    • Tribology and Lubricants
    • /
    • v.33 no.4
    • /
    • pp.134-140
    • /
    • 2017
  • With the increase in adoption of tilting pad journal bearings (TPJBs), various failure mechanisms related to TPJBs have been reported, of which pad wear is a frequently reported one. Pad wear causes change in geometry of the bearing, which can sometimes result in the failure of the entire system. The objective of this research is to investigate the influence of pad wear on the pad temperature, which is one of the widely used condition monitoring methods for TPJBs. For the theoretical investigation, thermohydrodynamic (THD) analysis was conducted by solving the generalized Reynolds equation and the 3D energy equation. The results of the analysis show that the temperature of the loaded pad increases while that of the unloaded pad decreases, when there is wear on the loaded pads. In addition, the minimum film thickness decreases with an increase in the wear depth. A validation test was conducted with a test rig, which mimics the axial turbine when a test rotor is supported by two TPJBs. The test bearing consists of five pads with a diameter of 60 mm, and a resistance temperature detector (RTD) is installed in the pad for temperature monitoring. The test was performed by replacing the two loaded pads with the worn pad. The test result for the TPJB with wear depth of $30{\mu}m$ show that the temperatures of the loaded pads are $8^{\circ}C$ higher and that of the unloaded pad is $2.5^{\circ}C$ lower than that of the normal TPJB. In addition, the predicted pad temperature shows good agreement with the measured pad temperatures.

비대칭 마그네트론 스퍼터링 방법으로 TiC 박막의 트라이볼로지 특성에 미치는 기판온도 영향

  • Park, Yong-Seop;Seo, Mun-Su;Hong, Byeong-Yu;Lee, Jae-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.703-703
    • /
    • 2013
  • 다이아몬드상 탄소 박막(Diamond-like carbon, DLC) 박막은 낮은 마찰 계수, 높은 내마모성, 화학적 안정성, 적외선 영역에서의 높은 투과율 등의 장점을 바탕으로 MEMS (Micro-Electro Mechanical System) 소자와 MMAs (Moving Mechanical Assemblies)의 고체윤활코팅, 마그네틱 미디어와 하드디스크의 슬라이딩 표면 등 다양한 분야에 코팅소재로써 응용되어왔다 [1,2]. 현재 전기철도용 집전판은 마찰이 적고 전도성을 지니는 카본 소재로 구성되어 있다. 그러나 그 마모 비율이 너무 심하여 이를 개선할 수 있는 방안으로 고경도 저마찰력을 지니는 DLC 박막을 코팅 소재로써 제안하고자 한다. 그러나 기존에 DLC 박막은 절연특성이 매우 우수하기 때문에 기존에 전도성을 지니는 카본 집전판에 적용하기에는 어려움이 따른다. 따라서 DLC 박막 내에 실리콘(Si) 또는 금속(Metal)을 첨가시키거나, 금속 중간층을 포함시켜 전기적으로 전도특성을 향상시키는 방안이 제시되고 있으며, 본 연구에서는 DLC 박막과 유사하게 우수한 경도특성을 지니고, 낮은 마찰계수등을 지니는 비정질 탄소박막을 연구하여 카본 집전판에 코팅하고자하며, 특히 비정질 탄소박막에 금속 Ti를 도핑하여 집전판과의 접착력과 전기적 전도 특성을 향상시키고자 한다. Ti가 도핑된 탄소박막(TiC) 박막은 비대칭 마그네트론 스퍼터링(unbalanced magnetron sputtering; UBMS) 시스템을 이용하여 제작하였으며, 스퍼터링 조건 중 기판에 인가되어지는 기판온도에 따라 변화되어지는 TiC 박막의 트라이볼로지(Tribology) 특성을 고찰하고자 하였다. 증착시 기판온도의 증가는 TiC 박막의 경도, 마찰계수 특성등 트라이볼로지 특성을 향상시켰으며, 전기적 전도 특성을 향상시켰다. 이러한 결과는 스퍼터링 방법에 의해 증착되어진 TiC 박막내에 존재하는 sp2 결합과 관계가 있음을 확인할 수 있으며, 트라이 볼로지 특성은 TiC 박막내에 sp2 탄소결합의 비율 증가와 관련되어졌다. 특히 sp2 탄소결합은 TiC 박막 증착시 증가된 기판온도와 밀접한 관계가 있으며 기판온도의 증가에 따라 나노결정 클러스터의 크기와 수의 변화와 밀접한 관계가 있음을 확인하였다. 결국 기판온도는 TiC 박막의 트라이볼로지 특성을 향상시켰으며, 전기적 특성 또한 향상시켜 전기철도 집전판에 응용을 위한 소재로 평가할 수 있다.

  • PDF

The Effect of Corrosion of Rolling Bearing Ceramics in Alkalic Solution on the Rolling Wear and Hardness (알카리용액에서 구름베어링용 세라믹스의 부식이 구름마모 및 경도에 미치는 영향)

  • 최인혁;김상근;박창남;윤대현;신동우
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.154-159
    • /
    • 1999
  • Silicon nitride ceramic has been verified as an excellent rolling bearing material because of its high strength and outstanding rolling fatigue life properties. However under some corrosive circumstances it showed drawbacks such as hardness reduction and severe wear caused by corrosion. In this work, the variations of the rolling wear and hardness of three kinds of ceramics were studied for the specimen aged 15 days in alkali water (90$\pm$2$^{\circ}C$, 25 wt% NaOH). All of the specimens, \circled1Si$_3$N$_4$, \circled23Y-TZP and \circled33Y-TZP alloyed with 5 wt% CeO$_2$, were sintered and post-Hipped, and then polished up to 0.02 ${\mu}{\textrm}{m}$Ra of surface roughness. Rolling wear tests were conducted by MJ type rolling fatigue life tester under the initial theoretical maximum contact stress or 3.76 Gra and the spindle speed of 1,000 rpm. Spindle oil was used as a lubricant. The specimens were not worn before aging. For the specimen aged in alkali water, Si$_3$N$_4$and 3Y-TZP were worn by rolling wear tests, and hardness was decreased. While aging the specimens, the phase was transformed from tetragonal to monoclinic in 3Y-TZP and the microstructure change occurred in Si$_3$N$_4$. 3Y-TZP alloyed with 5 wt% CeO$_2$specimens were not worn after aging and no phase transformation occurred while aging.

  • PDF

초고속 자기부상형 터보복합분자 펌프 기술 개발

  • Park, Yong-Tae;No, Seung-Guk;Kim, In-Chan;O, Hyeong-Rok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.88-88
    • /
    • 2011
  • 복합분자펌프는 기존의 터보분자펌프 turbine blade에 spiral grooved를 추가하여 초고진공(10-8 Pa)에서 저진공(330Pa)까지 넓은 압력범위에서 사용할 수 있고 이 펌프를 사용함으로서 완전 oil free한 진공시스템을 만들 수 있는 특징을 가지고 있다. 특히, 회전체를 비접촉으로 지지하는 자기베어링 방식을 적용함으로써, 진동은 극히 작고 베어링수명은 길면서 중저진공에 대한 배기속도가 크고 임의의 방향으로 접속이 가능하여 반도체 및 디스플레이 제조 공정과 같은 첨단산업의 다양한 분야에 쉽게 적용되고 있으며, 그 적용 분야와 시장은 계속 성장하고 있다. 고 진공과 배기 속도의 달성을 위해서, 고속으로 이동하는 격면과 기체분자를 충돌시켜, 기체 분자를 원하는 방향으로 유도하는 작동원리를 가지고 있다. 특히 공기분자의 밀도가 매우 낮은 희박가스 상태에서 고속 회전하는 blade로 공기분자를 쳐 내면서 작동됨으로써 날개의 상하 압력차에 의한 공기력보다도 날개의 고속회전이 매우 중요시 되고 압력으로는 10-1 Pa 이하의 분자영역에서 그 성능을 최고로 발휘 할 수 있다. 이러한 복합 펌프의 주요 장점은 다음과 같다. 1. 10-8 Pa (10-10torr)~10 Pa (1 torr) 까지 넓은 영역에서 배기가 가능하다. 2. 탄화수계의 대하여 높은 압축특성을 가지고 있고, 윤활유를 사용하지 않으므로 얻을 수 있는 진공상태가 고청정하다(oil free). 3. 정밀 5축제어 자기베어링으로 완전히 부상하여 회전함으로서 마모가 없고 진동이 최소화하였을 뿐만 아니라, 또한 운전음도 거의 없다. 4. 설치조건에 제한이 없고 고장이 거의 없다. 본 논문에서는 이러한 복합분자펌프의 개발을 위하여, 상기 연구기관에서 수행된 내용을 소개하고 있으며, 펌프 시스템의 기본 설계 및 자기베어링 시스템의 설계 결과 및 수치해석 결과를 나타내었다.

  • PDF

The Effect of Glyceride Modified by Fatty Acid on Mechanical Properties of Silica filled Rubber Compounds (지방산으로 개질된 글리세라이드가 실리카 충진 배합고무의 가황과 기계적 물성에 미치는 영향)

  • Kim, Dong-Wook;Kim, Chang-Hwan;Jung, Ho-Kyun;Kang, Yong-Gu
    • Elastomers and Composites
    • /
    • v.48 no.2
    • /
    • pp.114-124
    • /
    • 2013
  • To study the effects of structural difference and fatty acid chain length of glyceride, new dispersion agents having various glyceride structures such as mono-, di-, and tri-, were prepared using glycerol extracted from palm oil and fatty acid having various chain length ranges from 12 to 18. These dispersion agents were mixed with the rubber compounds and compared with conventional metal salt dispersion agents. Glyceride dispersion agent provided remarkable improvement in silica dispersion, compared to metal salt fatty acidic one, even though the viscosity of mixtures was relatively high due to low lubricating effect, and this was approved by mechanical properties, wear properties, and Payne effect. Also, the longer in chain length of fatty acid and the smaller in numbers of fatty acid, the dispersity of silica was improved.

A Study on The Optimization of Plastic Mold Steel Machining Using MQL Supply System (MQL 공급시스템을 이용한 플라스틱 금형강 가공 최적화에 관한 연구)

  • Hong, Kwang-Pyo;Song, Ki-Hyeok;Lee, In-Cheol;Kang, Dong-Sung;Chung, Jae-Hwa;Lim, Dong-Wook;Kim, Woon-Yong;Beck, Si-Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.6
    • /
    • pp.7-14
    • /
    • 2017
  • This study manufactured a minimum quantity lubrication (MQL) supply system and identified the optimal MQL machining cutting conditions for plastic mold steel (SCM440). A series of experiments were consisted of twice. Optimal cutting conditions were derived using the Taguchi method, and cutting force variance; surface roughness; tool wear; and cutting temperature in dry, wet, and MQL machining were measured experimentally for these optimal conditions. The measured results decreased from dry to wet and MQL machining, being particularly large for dry machining due to increased cutting time. Measured MQL machining metrics were similar to those for wet machining, particularly for surface roughness, which is an index of machining quality.