• Title/Summary/Keyword: 유효측정점

Search Result 192, Processing Time 0.041 seconds

Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

The Experimental Study of the Effective Point of Measurement for Cylindrical Ion Chamber -For Medical Electron Beams- (원통형 전리함의 유효 측정점에 관한 실험적 연구 -의료용 전자선을 중심으로-)

  • 이병용;최은경;장혜숙;홍석민;이명자;전하정
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.155-160
    • /
    • 1991
  • We have studied the effective point of measurement for cylindrical ion chamber in water phantom for medical electron beams. Markus parallel plate chamber water phantom are used for the measurement of depth dose to determine the depth of the effective point of measurement for various energies(for electron 6MeV, 9MeV, 12MeV, 16MeV, and 20MeV; Co-60; for photon 6MV, 15MV). Cylindrical ion chambes(PTW233643 with r=2.75mm, PR-05P with r=2mm, and PM30 wiht r=15mm are used for the measurement of depth dose by same mtethod and the values of d$\_$50/ and R$\_$p/ obtained by three cylindrical chambers were compared with those of a flat chamber. From this we could evaluate the effective measuring points of cylindrical ion chamber. The effective point of measurement was estimated as 0.4~0.6r shifted toward surface from the center of the chamber for electron beam, 0.3~0.7r for $\^$60/Co X-ray.

  • PDF

Correction for Scanning Errors of a CCD Camera Scanner (CCD Camera Scanner의 스캐닝 왜곡 보정기법 연구)

  • 안기원
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.12 no.2
    • /
    • pp.173-180
    • /
    • 1994
  • One can see more and more photograrmmetric applications dealing with the extraction of information from images obtained with CCD (Charge Coupled Device) camera scanners. In order for this information to be useful, the scanning errors of scanners must be known through a calibration. Investigation of this study is given to the detailed procedure of the correction for scanning errors created during the scanning of photographs with CCD camera scanner using the three kinds of high resolution reseal plates prepared. The geometric corrected digital images for scanning errors were generated and the accuracy of the resulting new images for each types of plates were checked comparing its image coordinates with there corresponding ground coordinates for the check points.

  • PDF

Measurement of the Effective Internet Diameter Based on Hop Counts of Effective Connections (실효 접속의 Hop Count에 기반한 인터넷 실효 지름의 측정)

  • 이지웅;김재균
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.745-747
    • /
    • 1999
  • 인터넷이 급성장함에 따라 사용자의 더 나은 서비스에 대한 요구 역시 급증하였다. 네트웍 연구가들은 제한된 네트웍 자원 하에서 오류제어, 흐름 제어, 그리고 폭주 제어를 적절히 수행함으로써 전송 품질을 향상시키는 방법들에 대해 연구해 오고 있다. 그러나 인터넷 연구의 가장 큰 난점 중 하나가 인터넷에는 네트웍의 상태를 모니터링할 수 있는 근간이 되는 방법이 기본적으로 지원되고 있지 않다는 점이고 따라서 네트웍의 구조와 상태, 플로우의 흐름 및 통계 등에 대한 기본 자료가 부족한 실정이다. 오류 제어나 흐름 제어, 그리고 폭주제어 기술을 연구할 때 가장 필요한 자료중의 하나가 네트웍 토폴로지이다. 그 중에서도 송신자와 수신자 사이의 거리 정보인 Network Diameter가 있다. 기존 연구에서는 연구자 임의로 이 값을 할당하거나 혹은 특정 실험실에서만 유효한 Network Diameter가 있다. 기존 연구에서는 연구자 임의로 이 값을 할당하거나 혹은 특정 실험에서만 유효한 Network Diameter 값을 제시해오고 있었다. 이 논문에서는 이처럼 비객관적이거나 특수값으로만 사용되어 오던 Internet Diameter를 실효 접속에 근거하여 측정하는 알고리즘을 제안하고, KAIST에서 전세계로 나가는 실측 접속 자료로부터 접속 Hop Count의 분포를 측정하며 이를 통해 타 인터넷 연구에 적절한 자료를 제시한다.

  • PDF

Thermophysical Properties of the Soybean Curd and Prediction of its Thermal Conductivity 2. The 'intrinsic' thermal conductivity of soybean protein and prediction of the thermal conductivity of soybean curd (두부의 전열물성 및 유효열전도도의 추정 2. 대두단상질의 고유열전도도 측정과 두부의 유효열전도도의 추정)

  • KONG Jai-Yul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.15 no.3
    • /
    • pp.219-225
    • /
    • 1982
  • Four heat conduction models were examined for defatted soy-protein curds in order to get the 'intrinsic' thermal conductivity of soy-protein. As the result of examination, the 'intrinsic', thermal conductivities of soy-protein, frozen and unfrozen states, were determined on the basis of series model to be 0.488 W/m.K and 0.300 W/m.K, respectively. By using the 'intrinsic' thermal conductivity values of soybean protein and the series model, the effective thermal conductivity of soybean curds, with and without fat, at frozen and unfrozen states, was predicted satisfactorily, The temperature dependency of the effective thermal conductivity of soybean curd was mostly observed to correlate with the thermal conductivity of water and ice.

  • PDF

An Effect of Organizational Environment and Commitment on the Operational Risk-Based Internal Control Commitment in Banks (조직환경 및 유효성이 은행의 운영리스크 내부통제유효성에 미치는 영향)

  • Chung, Hae-Won;Kim, Hyun-Soo;Ahn, Yeon-Shick
    • 한국IT서비스학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.3-8
    • /
    • 2007
  • 지난 2004년 6월 24일에 공표된 신BIS 자기자본규제제도에 의거 회원국 은행들에 대한 체계적인 위험관리가 강화되는 상황에서 우리나라도 2009년부터 모든 은행이 신BIS기준을 도입및 적용할 예정이다. 신BIS협약은 운영리스크(부적절한 내부절차, 직원, 시스템)에 대해서도 리스크를 측정하여 은행의 소요 자기자본에 반영토록 하고 있다. 따라서 본 연구자는 은행의 조직환경 변수들이 조직유효성에 영향을 미치고 이들이 또한 내부통제절차의 상시 유효성에 영향을 미치는 지 알아보기 위하여 국내 소재 은행원들을 대상으로 실증분석함으로써 은행들이 효율적인 내부통제를 통해 금융사고를 미연에 방지하고 은행자산의 건전성에 기여하기 위한 지침을 제시하는 관점에서 연구를 진행하였다. 연구결과, 연구모형에서 예상한 바와 같이 조직환경이 내부통제유효성에 직접적으로 영향을 미치지만 조직몰입도나 집단응집력과 같은 조직유효성을 매개로 하여 내부통제유효성에 더욱더 영향을 미치고 있었다. 이러한 점에 비추어 본 연구의 결과를 토대로 은행내 중간관리자의 성향에 따라 개별조직 구성원들의 행동양식이나 가치관에 영향을 미칠 수 있는 현실을 감안하여 장기적인 안목에서 양질의 리더십, 조직문화 그리고 분위기 등 조직환경을 리드해 나갈 수 있도록 관리자들에 대한 교육훈련 및 소양교육을 지속적으로 펼쳐나가는 것이 중요하다고 본다.

  • PDF

The Estimation of Yaw Direction of Wind Turbine Using Vision System (비전 시스템에 의한 풍력발전기의 Yaw방향 추정)

  • Jeong, Myung-Hee;Jeong, Jun-Ik;Rho, Do-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.199-201
    • /
    • 2006
  • 풍력발전기에 있어서 블레이드의 Yaw방향 제어는 끊임없이 변화하는 풍향에 대해 효율의 극대화와 블레이드의 강도 및 진동측면에서 대단히 중요하다. 기존의 블레이드 Yaw 방향 측정은 접촉 및 비접촉 센서가 이용되어왔다. 본 논문에서는 풍력발전기의 원격모니터링 시스템에서 기본적으로 설치되는 카메라를 이용하여 블레이드의 Yaw방향을 측정하는 방법을 제안한다. 블레이드가 풍향에 따라 회전할 때 영상 누적을 행하고, 누적영상에 대해 경계점을 추정하여 타원의 궤적을 추정한다. 추정된 경계점들을 이용하고 최소자승법을 적용하여 타원방정식을 추정하고, 장축과 단축을 연산한다. 장축과 단축의 변화를 이용하여 카메라의 촬영방향의 기준점으로부터 Yaw방향의 변화를 정량적인 값으로 산출하여 이를 바탕으로 Yaw회전각을 추정한다. Yaw 방향 추정의 검증을 위해 블레이드 속도와 Yaw 방향의 제어가 가능한 모형풍력발전기를 제작하고 실험을 통하여 제안한 추정알고리즘의 유효성을 검증한다.

  • PDF

사료의 대사 에너지 측정 및 대사 에너지가에 영향을 미치는 요인

  • 최진호
    • KOREAN POULTRY JOURNAL
    • /
    • v.5 no.1 s.39
    • /
    • pp.95-99
    • /
    • 1973
  • 사료중에 포함된 총에너지는 이것이 전량 동물에게 이용되는 것이 아니고 여러가지 형태로서 손실이 일어나는 것이다. 분과 뇨 그리고 열량증가로서의 에너지의 손실을 공제하고 실제로 동물에게 이용되는 에너지를 정미 에너지라고 하며 정미에너지는 다시 생산과 유지에 쓰이기 위한 것이다. 동물에게 실제로 이용되는 유효에너지인 정미에너지가를 추정하는데는 가소화에너지, 대사에너지, 생산에너지가 흔히 사용되고 있으나 그중에서 구하기가 비교적 쉽고 유효에너지의 훌륭한 척도가 될 수 있는 대사에너지(ME)의 개념이 가장 많이 쓰이고 있다. 대사에너지의 약점은 동물의 체내에서 일어나는 에너지의 손실중 열량증가(Specific dynamic action)로서의 손실을 고려하지 않았다는데 있으며 이로 인해서 몇가지 문제점들이 발견되고 있으나 지금까지 많은 연구가 이루어져 왔으며 앞으로도 계속해서 검토되어야 할 것이다. 성장중의 병아리를 대상으로 ME를 추정하는 방법은 많은 학자들에 의해서 창안되었으며 실제로 많은 단미사료의 ME함량에 대한 데이타는 손쉽게 구할 수 있다. 그러나 산란계를 대상으로 한 시험은 많지 않았으며 병아리로부터 얻어진 데이타를 산란계에 적용하고 있는 실정인바, 어떤 사료에 대해서는 병아리와 산란계 사이에 이용성이 다를 수 있다는 점에서 앞으로는 보다 많은 단미사료에 대해서 산란계로부터 직접 측정하여 이용함이 바람직하다. 생물학적인 사양시험을 통해서 직접 측정된 ME가와 그 사료의 화학적 성분함량과의 관계를 조사함으로써 화학적 조성으로 ME가를 추정하는 방법의 개발은 그 추정치가 반드시 정확하지는 않다 하더라도 사전 지식이 없는 새로운 단미 사료에 부딛쳤을때 그 사료의 대략적인 에너지가를 짐작하는데 도움을 준다. 각종 단미사료의 ME함량에 대해서 우리나라에서 측정된 자료가 많지 않고 대부분 외국의 데이타를 이용하고 있는 실정인바 앞으로는 우리나라에서 실제 사용되고 있는 많은 단미사료에 대한 ME가 직접 국내에서 측정, 이용되어야 할 것으로 생각한다.

  • PDF

녹용 물추출액이 흰쥐혈액중의 급성기 반응 단백질에 미치는 영향

  • 한용남;김경옥;황금희
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1994.04a
    • /
    • pp.238-238
    • /
    • 1994
  • 녹용의 알려진 약리작용 중에서 녹용의 상용량 투여에 의해 나타나는 것은 강장작용과 창상치유작용이므로 이러한 작용이 진정한 녹용의 효능으로 간주될 수 있으나 이러한 작용을 생물활성 검색법으로 활용하여 녹용의 유효성분을 검색하기에는 재현성과 간편성이라는 면에서 어려운 점이 없지 않다. 녹용의 효능이 생체의 질소평형이 음의 방향으로 진행되었을 때 이를 정상 수준으로 복귀시키는 생물활성에 기인할 것이라는 가정하에서, 실험적으로 생체내 질소편형을 음의 방향으로 전환시킬 수 있는 급성기 반응 (acute-phase responce)을 야기시킨 다음 녹용의 효과를 연구하였다. 흰쥐의 급성기 반응물질 (acute-phase reactants, APR) 중에 서 positive ARP인 ceruloplasmin, $\alpha$-cysteine pretense inhibitor(= T-kininogen)는 비색정량법으로 간편하게 측정될수 있음에 착안하여 이 단백질을 지표로 삼아 turpentine oil로 급성 염증을 유발시킨 전후에 녹용 물추출액의 효과를 측정하였다. 그 결과 녹용의 상용량에서 괴소 4일 이상 경구투여한 흰쥐에서 급성 염증유발 후 4일에서 ceruloplasmin 의 혈중농도가 현저히 감소함을 알수 있었다. 급성 염증 유발후 녹용의 경구투여한 실험에서는 적어도 녹용 상용량의 3배 이상을 투여하여야 만 ceruloplasmin 혈중 농도를 감소시킬 수 있었다. 본 연구에서 수립된 생물활성을 이용하여 녹용의 유효 성분을 단리할 계획이다.

  • PDF

A Study on Evaluation of Crack Opening Point in Fatigue Crack Propagation Course (II);Parameter Sensitivity Study of Crack Opening Ratio by Using Numerical Calculation (피로크랙 진전과정에서의 크랙열림점 평가에 관한 연구(II))

  • 최병기;윤한용;박창언;정태권
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.3
    • /
    • pp.931-935
    • /
    • 1991
  • 본 연구에서는 유효응력확대계수로서 피로크랙 진전수명을 평가할 수 이용되 는 크랙열림비(본 논문에서는 후술하는 최대응력에 대한 크랙 열림응력의 비를 크랙 열림비로 하다)가 진전수명에 미치는 영향을 평가하기 위한것으로서, 제1보에서는 실 험에 의하여 크랙 열림점을 실측한 결과 측정입치에 따라 다른 값을 나타내며 수명평 가법 크랙 선단으로부터 떨어진 곳(크립게이지를 이용한 크랙마우스등)에서 측정한 크 랙 열림점 값을 이용함이 보다 정확함을 밝혔다.본 제2보에서는 크랙열림비가 수명 평가에 미치는 영향을 상기의 파라미터 영향도 평가수법을 이용하여 평가하고자 한다.