• Title/Summary/Keyword: 유효자극영역

Search Result 8, Processing Time 0.02 seconds

A Numerical Study on the Thermal Stimulation of Continuous Moxibustion (연속 뜸의 열 자극에 대한 수치해석)

  • Yang, So-Ra;Kang, Ho-Young;Jeon, Byoung-Jin;Choi, Hyoung-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.915-922
    • /
    • 2011
  • In this paper, the unsteady incompressible Navier-Stokes equation coupled with energy equation was solved in order to investigate the thermal stimulation of continuous moxibustion using a commercial code (ANSYS-Fluent). In the simulations, various periods were selected for the continuous moxibustion, which was done by burning multiple disks successively. It has been found that the depth of the effective stimulation zone increases only when the replacing temperature is equal or larger than body temperature whereas the increase rate of the effective stimulation depth decreases as the number of disc increases. Further, it has been shown that the optimal period, for which the duration time of the effective stimulation zone is maximum, exists.

The Effects of Warm and Cold Stimulations on the Temperature Distribution in the Prostate (냉.온열의 반복 자극이 전립선 내부의 온도 분포에 미치는 영향)

  • 문우석;백병준;박복춘;김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.467-475
    • /
    • 2002
  • Hyperthermia using transrectal thermal probes has been used for a noninvasive treatment of prostate diseases. However it is known that heating the rectal wall at excessively high temperature can lead to destruction of the rectal mucous membrane. and it is difficult to maintain an optimum temperature over the entire prostate. Thus, a more accurate understanding of the heat transfer mechanism between prostate and hyperthermia system is needed Numerical analysis was performed to investigate how the cold/warm stimulations on the prostate surface affect the temperature distribution in the prostate model. The general purpose software "FLUENT" was used for obtaining a finite volume solution to the unsteady conduction equation and to calculate the time-varying temperature in the prostate. Effects of the warm/cold stimulations and the stimulation frequency on the temperature distribution were simulated. and we visualized how hyperthermia affected the inside of the prostate. It was found that the effect of hyperthermia by using a typical heating method is limited due to the low thermal conductivity of the prostate. Consecutive repetitions of warm and cold stimulations were considered to provide the thermal irritations inside a prostate. The effects of temperature difference and duration of warm/cold stimulations were investigated, and basic data for the optimum period and effective patterns of stimulations were obtained. A simplified bioheat equation was also solved to describe effects of the blood flow on the blood-tissue heat transfer. The effect of blood flow was not dominant compared to that of warm/cold stimulations. These results might be used as data for design of prostate treating probe, prostatic therapy and thermal stimulation effects on the prostate.

A Study on Rotor Polarity Detection of SP-PMSM Using Offset Current Based on Current Control (전류 제어 기반 옵셋 전류를 이용한 단상 영구자석 동기 전동기의 회전자 자극 검출에 관한 연구)

  • Park, Jong-Won;Hwang, Seon-Hwan
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.1020-1026
    • /
    • 2019
  • In this paper, a rotor polarity detection algorithm is proposed to control the single-phase permanent magnet synchronous motors(SP-PMSMs) for high speed sensorless operation. Generally, the sensorless control of a SP-PMSM is switched to the sensorless operation in a specific speed region after the open loop startup. As a result, it is necessary to detect the rotor polarity to maintain a constant rotational direction of the SP-PMSM at the starting process. There, this paper presents a novel rotor polarity detection method using a high frequency voltage signal and offset current which is generated by current regulator. The proposed algorithm verified the effectiveness and usefulness of the rotor polarity detection through several experiments.

Salty-taste Activation of Human Brain Disclosed by Gustatory fMRI Study (뇌기능 자기공명영상 장치를 이용한 짠맛 자극에 따른 인간 뇌의 반응에 대한 기초 연구)

  • Kim S.H.;Choi K.S.;Lee H.Y.;Shin W.J.;Eun C.K.;Mun C.W.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.30-35
    • /
    • 2005
  • Purpose : The purpose of this study is to observe the blood oxygen level dependent (BOLD) contrast changes due to the reaction of human brain at a gustatory sense in response to a salty-taste stimulation. Materials and Methods : Twelve healthy, non-smoking, right-handed male subjects (mean age: 25.6, range: 23-28 years) participated in this salty-taste stimulus functional magnetic resonance (fMRI) study. MRI scans were performed with 1.57 GE Signa, using a multi-slice GE-EPI sequence according to a blood-oxy-gen-level dependent (BOLD) experiment paradigm. Scan parameters included matrix size $128\times128$, FOV 250 mm, TR 5000 msec, TE 60 msec, TH/GAP 5/2 mm. Sequential data acquisitions were carried out for 42 measurements with a repetition time of 5 sec for each taste-stimulus experiments. Analysis of fMRI data was carried out using SPM99 implemented in Matlab. NaCl solution $(3\%)$ was used as a salty stimulus. The task paradigm consisted of alternating rest-stimulus cycles (30-second rest, 15-second stimulus) for 210 seconds. During the stimulus period, NaCl-solution was presented to the subject's mouth through plastic tubes as a bolus of delivered every 5 sec using -processor controlled auto-syringe pump. Results : Insula, frontal opercular taste cortex, amygdala and orbitofrontal cortex (OFC) were activated by a salty-taste stimulation $(NaCl,\;3\%)$ in the fMRI experiments. And dosolateral prefrontal cortex (DLPFC) was also significantly responded to salty-taste stimuli. Activation areas of the right side hemisphere were more superior to the left side hemisphere. Conclusion : The results of this study well correspond to the fact that both insula, amygdala, OFC, DLPFC areas are established as taste cortical areas by neuronal recordings in primates. Authors found that laboratory-developed auto-syringe pump is suitable for gustatory fMRI study. Further research in this field will accelerate to inquire into the mechanism of higher order gustatory process.

  • PDF

Design and manufacture of mini loop coil probe style magnetic curer for peripheral nervous system treatment (말초신경계 치료를 위한 초미니 Loop-코일프로브 삽입형 자기치료기의 설계 및 제작)

  • Kim, Whi-Young;Choi, Jin-Young;Park, Sung-Jun;Kim, Hee-Je
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.2 no.1
    • /
    • pp.153-169
    • /
    • 2007
  • It is as result that study to apply mini magnet nerve curer in peripheral nervous system disease treatment. Design and embodied action power and Control Unit in cylinder form of magnet roof object firstly. Yielded service area about special quality of probe of roof object cylinder style and treatment area dimension and distance of treatment pulse secondly. Embody pulse forming course energy value by Probe's form by third, could embody treatment pulse by disease. Specially, through a special quality experiment, saved Damping pulse form and treatment pulse form etc. variously. Lately, embodied this to aid a little in disease treatment that follow that there is no invasion that there is no stimulation by medicine development. Go amplitude treatment pulse (traditional magneto-therapy of greatly great that strong) does curative effect greatest at short time and becomes thought that demand is magnified greatly at the future in this research.

  • PDF

Efficiency Analysis of Cardiac Hand Acupuncture by Measuring the Bio-Image Signals (생체 영상신호 측정을 통한 심장 수지침 효능 분석)

  • Kim, Bong-Hyun;Cho, Dong-Uk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3319-3325
    • /
    • 2013
  • In this paper, hand acupuncture used as a way of life medicine in everyday life, the influence of human organ will be investigated by applying IT techniques. For this, hand acupuncture is based on priority of the most important organ in the human body to target the cardiac associated with cardiac reflex point A16 acupuncture point before and after for 5 min to stimulation of facial images were collected and applied to the Lab color system associated with the cardiac, color value of cheonjung and lips region were measured for comparison and analysis. Finally, by measuring the change in bio-image signals A16 acupuncture point stimulation effects on cardiac function were performed to investigate the effectiveness of acupuncture. Also, statistical significance tests from the experimental results were performed whether the experimental results is valid or not.

SNU 1.5MV Van de Graaff Accelerator (IV) -Fabrication and Aberration Analysis of Magnetic Quadrupole Lens- (SNU 1.5MV 반데그라프 가속기 (IV) -자기 4극 렌즈의 제작과 수차의 분석-)

  • Bak, H.I.;Choi, B.H.;Choi, H.D.
    • Nuclear Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 1986
  • A magnetic quadrupole doublet was fabricated for use at the pre-target position of SNU 1.5MV Van de Graaff accelerator and then its optical characteristics were measured and analysed. The physical dimensions are: pole length 180mm, aperture radius 25mm, pole tip radius 28.75mm. Material for poles and return yokes is carbon steel KS-SM40C. Coils have 480 turns per one pole and air-cooling is adopted. Applying the d.c. current 2.99$\pm$0.03A to the lens, and using the Hall probe, magnetic field elements $B_{\theta}$ , $B_{\gamma}$, were measured at the selected Points along each coordinate direction r,$\theta$, z. From the area integration and orthogonal polynomial fitting for the measured data, the magnetic Field gradient G=566.3$\pm$2.1 gauss/cm at lens center, the effective length L=208.3$\pm$1.44mm along the lens axis have been obtained. The harmonic contents were determined up to 20-pole from the generalized least squares fitting. The results indicate that sextupole/quadrupole is below 1.4$\pm$0.9% and all the other multipoles are below 0.5% in the region within 18mm radius at the center of lens.

  • PDF

A Study on the Design and Fabrication of Fat Emulsification Adapted Focused Ultrasonic Transducer (지방 조직 유화를 위한 집속형 초음파 변환기 설계 및 제작에 관한 연구)

  • Kim, Ju-Young;Kim, Jae-Young;Jung, Hyun-Du;Noh, Si-Cheol;Mun, Chang-Su;Mun, Chi-Woong;Choi, Heung-Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.127-134
    • /
    • 2015
  • Tissue stimulation technique using ultrasound has been continuously studied and developed. Recently, as a increment of interests for obesity treatment and cosmetic care, a various studies on ultrasonic fat emulsification has been conducted. In this study, the fat emulsification adapted ultrasonic transducer was designed. And using designed transducer, the simulation for the shape of focal area and thermal degradation region was conducted. The dimensions were verified by the simulation results. And the effectiveness was confirmed by evaluating measured radiation characteristic and heating characteristic. In addition, we estimated the ultrasonic heating characteristics in composite structure medium. The shape of focal point and heating characteristic of the proposed transducer were determined to be sufficient to emulsify the fat. The results of this study are considered to be used as basic research in more efficient and safe ultrasonic fat removal.