• Title/Summary/Keyword: 유한 광학계

Search Result 42, Processing Time 0.03 seconds

Finite Raytracing Through Non-rotationally Symmetric Systems (비대칭형 광학계의 유한광선추적)

  • 홍경희
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.217-222
    • /
    • 1990
  • A general ray tracing scheme has been developed for using a personal computer which trace finite rays through any non-rotationally symmetric system. This scheme may be used for the surface type such as conic section with or without aspherics, toric surfaces, sagittal and tangential cylindrical sections and axicons. Specially, any combinational of decentered, tilted and rotated surfaces has been considered. Before transfering to the next surfaces, the local coordinates are refered back to an initial reference coordinate system. We can get a mathmtical model of a non-rotationally symmetrical finite ray trace running on an inexpensive personal computer.

  • PDF

Performance Evaluation and Design of Zoom Lens Systems (Zoom Lens계의 성능 평가 및 설계)

  • Ji, Taek Sang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.113-121
    • /
    • 2002
  • Nowadays, developed camera, camcorder, CCTV and copier system accept a wide angle and a telephoto lens, and have an excellent capacity. Also, it is small as using aspheric surface. In this paper, after we evaluate and analyze two-group zoom lens system and three-group zoom lens system for camera, we refer to it, and design three-group zoom lens system for camera. Therefore, when we design a zoom lens system for camera, we use a symmetrical system. As using an aspheric surface, we can try to a miniaturization and an efficient improvement. We use optical valuable measure methods, a ray intercept plot, MTF and Seidel coefficient. So, we can confirm to have a similar level to compare with reference model.

  • PDF

Design and Aberration Analysis of Four-Spherical Mirror System Corrected for 4 Aberrations (4개의 수차가 보정된 유한 물체점을 갖는 4-구면 반사경계의 설계 및 수차해석)

  • 김종태;공홍진;이상수
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.3
    • /
    • pp.127-132
    • /
    • 1991
  • We have obtained the analytic solutions of the four spherical mirror system free from the Seidel third order aberratios which are spherical aberration, coma, astigmatism, and distortion, Vignetting. Petzval field curvature, and optical properties according to the design parameters are numerically investigated and optimized. The numerical aperture of this system is 0.2 and the half field angle is $1.5^{\circ}$.

  • PDF

Development of Transformable Reflective Telescope Kit Using Aluminum Profile and Isogrid Struture

  • Lee, Sumin;Park, Woojin;Lee, Sunwoo;Han, Jimin;Ann, Hojae;Ji, Tae Geun;Kim, Dohoon;Kim, Ilhoon;Kim, Junghyun;Pak, Soojong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.38.1-38.1
    • /
    • 2021
  • 본 발표에서는 Transformable Reflective Telescope(TRT kit)의 새로운 버전을 소개한다. TRT kit는 기본형인 뉴턴식 반사망원경에서 부경 교체를 통해 카세그레인식, 그레고리식으로 간단하게 변형 할 수 있는 광학 실험장치이다. 본 장치는 주로 망원경 교육이나 광학계 개발에 필요한 실험에 활용된다. 모듈화 설계를 통해서 여러 종류의 광학계를 쉽게 탈착하여 다양한 실험을 할 수 있다. 광기계부는 정밀하게 제작된 알루미늄 프로파일과 Isogrid구조를 채택하여 경량화 구조로 설계되었다. 이러한 경량부품들을 통해 이전 버전보다 50~70%의 중량 감소율을 달성하였다. 유한요소해석 결과 경량화된 뉴턴식 TRT kit는 이전 버전과 비교해서 자체 하중에 의한 최대 구조 변형이 0.11mm에서 0.023mm로 감소하였다. 부경 지지대 설계에는 자체 하중으로 인한 변형을 최소화하기 위해 트러스 (Truss) 구조가 도입되었다. 부경부의 자체 하중으로 인한 변형은 기존의 80㎛에서 21㎛로 감소하였다. 또한, 십자 레이저 정렬 장치가 추가되어 뉴턴식과 카세그레인식에서 공차 1.5' 이내로 광학계 정렬이 가능하다.

  • PDF

Developement of Scope for Military Rangefinder Using Schmidt Prism and Biprism Theory of Optometric Instrument (안광학기기에 사용되는 바이프리즘원리와 슈미트 프리즘을 이용한 군사 거리측정기용 스코프 개발)

  • Cha, Jung-Won;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.167-175
    • /
    • 2015
  • Purpose: The new-type rangefinder, which is using the biprism principle, is introduced to develop the range finder which can be easily carried by soldiers, and in order to realize those technologies specifically, we try to develop a scope for military rangefinder by doing optical design which can secure enough space to move the biprism. Methods: After setting up the verious initial condition to realize two kinds of goals, that are the securement of enough space to move the biprism and the easy-exchangeability of two kinds of biprisms, and then the optical system was optimized by using optical design program CodeV in order to minimize the finite ray aberrations. Results: We designed the biprism housing to makes it possible to swap the two kinds of biprisms. It was appeared that the Schmidt prism is suitable as erecting prism which can make sure the space to move the biprism. 16.5 mm was good for the face length of Schmidt prism. The optical system with a Schmidt prism and a biprism was designed, and the finite ray aberrations was minimized. Conclusions: We developed a 5X scope for an optical rangefinder using a biprism and a Schmidt prism with 16.5 mm face length. This scope is valid for the optical system which has the effective field angle of ${\pm}3.6^{\circ}$, and the finite ray aberrations are well controlled within the ${\pm}8.95^{\prime}$.

Case Study on Applications of Industry Using Holographic Interferometry (홀로그래피 간섭계를 이용한 산업현장의 소음진동 저감 연구사례)

  • 장석원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.456-456
    • /
    • 2001
  • Holography Interferometry 와 Speckle Interferometry는 넓은 응용범위를 갖는 유용한 광학적 시험 기술이다. 이러한 홀로그래피 간섭계와 스페클 간섭계를 이용하여 기계 산업에 있어서 제품 개발기간을 단축시키고 품질향상을 위해 수행된 소음, 진동 문제점등에 대한 원인규명 연구 등에 대하여 토의될 예정이며 또한 기존의 유한요소해석과 같은 해석적인 방법과 실험적인 방법의 효율 상에서의 차이점 등에 대해서도 토의될 예정이다.

  • PDF

A study on the Optical Properties of two component zoom copier lens system (2군 줌 복사기 렌즈계의 광학적 성능)

  • Ji, Taek Sang;Lim, Hyeon Seon;Kim, Bong Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.119-125
    • /
    • 2000
  • We analyzed to calculate optical capacity after we chose established 2 component zoom copier lens system in this research. As the lens system is zoom lens system of finite object point, it has moving area limited not like to use generally camera zoom lens of infinite object point because it moves between object and image plane. The magnification of optical system can obtain -1.41~-0.64 i.e., extended or shortened image as transverse magnification, and it acquires f/12 and about $20^{\circ}$ field of view. Although this 2 component zoom copier lens system will be down resolution and dark compared with f/2.8 acquired at camera lens, it will be possibile to be able to make large aperture and it can acquire more better correct aberration with the addition of auxiliary group forward or backward.

  • PDF

Optical Design of Afocal Zoom Telescope System for Thermal Imagery (열상장비용 줌무초점망원경 설계)

  • 홍경희;김창우
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 1995
  • A IR zoom telescope system was designed for thermal imagery. The magnification is 4-14 and the focal length of eye piece is 25 mm. First, the frame was built up with first order optics and started design with 3rd order optics. There after, we can get the final design by optimization technique through finite ray tracing. The optical system was optimized with ray aberration or angular aberration including higer orders. Finally, The performance of the optical system was accessed by calculating the diffraction MTF from the design data. data.

  • PDF

The optical capacity's comparison, analysis of copier zoom lens system between symmetric and asymmetric forms (대칭형과 비대칭형 복사기 줌 렌즈계의 광학적 성능 비교 분석)

  • Ji, Taek-Sang;Lim, Hyeon-Seon;Kim, Bong-Hwan
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.1-9
    • /
    • 2001
  • This research chose the existing designed copier zoom lens system and analyzed to calculate the optical capacity. As this lens system was the zoom lens system of finite object point, differed form the general camera zoom lens of infinite object point, it got a limited movement range because it moved between the fixed object and the image. In the result of comparison the optical capacities between a symmetric form and a asymmetric form. We could find out the truth which a asymmetric form constituted comparative stable aberrations and existed a tracks of effort for aberration correction. Therefore, a symmetric form is allotted satisfactorily from improved aberrations by itself in the fixed focal lens system. However, it has a limit of improving for capacity when it is used a zoom lens system got a symmetric form.

  • PDF