• 제목/요약/키워드: 유체 탱크

검색결과 190건 처리시간 0.023초

판형 및 다공형 배플을 포함한 탱크 내 슬로싱에 대한 유동해석 (A NUMERICAL ANALYSIS OF THE SLOSHING IN A TANK WITH PLATE/POROUS BAFFLES)

  • 이상혁;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.215-222
    • /
    • 2009
  • In the present study, a numerical analysis on the sloshing in a tank with the harmonic motion was investigated. A VOF method was used for two-phase flows inside the sloshing tank and a source term of the momentum equation was applied for the harmonic motion. This numerical method was verified by comparing its results with the available experimental data. The sloshing in a tank causes the instability of the fluid flows and the fluctuation of the impact pressure on the tank. By these phenomena of the tank sloshing, the sloshing problems such as the failure and the noise of system can be generated. For the reduction of these sloshing problems, the various baffles such as the horizontal/vertical plate baffles and the porous baffles inside the tank are installed. With the installations of these baffles, the characteristics of the liquid behavior in the sloshing tank, the impact pressure on the wall, the amplitude of the free surface near the wall and the sloshing noise were numerically analyzed.

  • PDF

대용량 피동형 유량제어 와류 밸브 (Large Capacity Passive Flow Control Vortex Valve)

  • 최남현;주인철;정장환;조봉현;송철화
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.635-640
    • /
    • 2004
  • The present paper provides the design specifications and working principle of flow controlling vortex valve which will be adopted in a Korean next generation reactor (APR1400). The vortex valve is installed inside the pressurized safety injection tank of APR1400, and it passively controls the water discharge flowrate from the tank. In the present study, the performance of the vortex valve have been evaluated throughout the repeated experiments in the full-scale test facility called VAPER(VAlve Performance Evaluation Rig). Based on the experimental results, it is confirmed that the currently developed vortex valve satisfies the major performance requirements of APR1400 plant design in view of the peak discharge flowrate, pressure loss coefficient, and total discharge duration time. To achieve the highest quality of the experimental results, a quality assurance program for vortex valve tests has been strictly applied.

  • PDF

SIMULINK를 이용한 연료 이송용 제트펌프 기본 설계에 관한 연구 (Study on Preliminary Design of Fuel Transfer Jet Pump Using SIMULINK)

  • 공창덕;박종하;한동주
    • 한국추진공학회지
    • /
    • 제10권1호
    • /
    • pp.38-43
    • /
    • 2006
  • 본 논문에서는 항공우주 부품 기술 개발 사업 중 연료 이송용 제트펌프 개발의 일환으로 제트펌프의 기본 설계 및 해석을 수행하였다. 제트펌프는 항공기 연료탱크 내에 위치하여 격막 간 또는 라인 간 연료 이송을 위하여 설치되는 연료 계통 이송 기능을 위해서 소요되는 핵심 부품이다. 제트펌프의 기본 설계를 위해 SIMULINK를 이용하여 계산식들을 모델링하였고 이를 바탕으로 제트펌프의 기본 설계 및 유동장 해석을 수행하였고 해석 결과 1차 노즐 출구에서 유체의 압력은 감소하면서 속도는 증가하고 유체가 디퓨져로 빠져나가면서 유체의 압력은 증가하고 속도는 감소하는 경향을 확인하였다.

1-way FSI 기법에 의한 LNG 운반선 화물창의 강도평가에 관한 연구 (The Study of 1-Way FSI for Strength Assessment of LNG Cargo Containment System)

  • 이성제;양용식;김성찬;이장현
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.527-530
    • /
    • 2011
  • 전 세계적인 LNG 수요 증가에 따라 LNG 운반선의 대형화 및 극한 환경의 항로 선택이 불가피해지고 있다. 이러한 상황에서 LNG의 슬로싱 현상에 따른 화물창의 구조적 안정성 여부가 큰 이슈거리로 떠오르고 있다. 슬로싱 현상에 의한 구조 안전성을 평가하는 가장 이상적인 방법은 유체 영역과 탱크의 복합적인 상호 작용을 완벽하게 구현하는 것이다. 하지만 과도한 계산 시간과 결과의 정확성이 확보되지 못한 상황에서 LNG 운반선 화물창의 안전성 평가에 적용하기에는 문제가 있다. 많은 연구 단체에서는 불규칙적인 슬로싱 압력 신호를 삼각파 등의 형태로 이상화하여 구조해석에 적용하고 있지만 이 또한 유체의 압축성 및 비선형성을 고려하는데 한계를 드러내고 있다. 본 연구에서는 슬로싱 하중을 받는 구조의 안전성을 평가함에 있어 쌍방향(2-way) FSI(Fluid-Structure Interaction)의 과도한 해석 시간 및 수렴의 어려움을 보안하고 유체의 비선형성을 고려할 수 있는 단 방향(1-way) FSI 기법을 이용하는 절차를 제안하고자 한다.

  • PDF

연료탱크 슬로싱 소음 저감을 위한 배플 및 다공성 물질 설치에 따른 유동해석 연구 (A NUMERICAL STUDY ON FLOWS IN A FUEL TANK WITH BAFFLES AND POROUS MEDIA TO REDUCE SLOSHING NOISE)

  • 이상혁;허남건
    • 한국전산유체공학회지
    • /
    • 제14권2호
    • /
    • pp.68-76
    • /
    • 2009
  • The sloshing tank causes the instability of the fluid flows and the fluctuation of the impact pressure by the liquid on the tank. These flow characteristics inside the sloshing tank can generate the uncomfortable sloshing noise. In the present study, a numerical analysis for the reduction of a fuel tank sloshing noise was performed. To simulate the flow characteristics in a sloshing tank with partially filled liquid, a VOF method was used for interfacial flows by applying a momentum source term for the sloshing motion in a non-inertial reference frame. This numerical method was verified by comparing its results with the available experimental data. For the reduction of the sloshing noise, the horizontal and vertical baffles and porous media inside a sloshing tank were considered and numerically analyzed in the present study. For various installations of these baffles and porous media, the characteristics of the liquid behavior in the sloshing tank were obtained along with the impact pressure on the wall and the height of the free surface along the wall. These basic results can be used for the design of the actual vehicular fuel tank with the reduced sloshing noise.

병진운동하는 사각형 유체저장탱크 내부의 슬로싱 특성 연구 (A Study on the Sloshing of the Rectangular Tank Partially Filled with Fluid Under Translational Motion)

  • 이영신;김현수;이재형;고성호
    • 한국소음진동공학회논문집
    • /
    • 제13권8호
    • /
    • pp.591-597
    • /
    • 2003
  • The oscillation of the fluid caused by external motions is called sloshing, which occurs in moving vehicles with contained fluid masses, such as the oil tankers, railroad cars, aircraft and rockets. Natural frequencies of fluid are much lower than that of solid structures, and the deformation caused by the excitation that is less than 1st natural frequency of fluid is very large. For the reason of that, sloshing characteristics under the ekcitation that is less than the 1st natural frequency must be studied prior to the consideration of natural frequencies of fluid. The experimental devices are constructed to simulate the translation motion. The rectangular tanks are made to study the sloshing characteristics under external excitation. The changes of water height are measured using an analogue camcorder and MPEG board, and those are compared to each other through a standard deviation. From the results of experiments, the sloshing is greatly influenced by the length of the rectangular tank than the width of that under the periodic translational motion in the length direction. The rapid amplification of sloshing by resonance is also confirmed experimentally.

Sloshing 충격압력의 추정을 위한 수치기법에 관한 연구 (A Numerical Study on the Prediction of Sloshing Impact Pressure)

  • 김용환;박용진;이화룡
    • 대한조선학회논문집
    • /
    • 제30권4호
    • /
    • pp.61-73
    • /
    • 1993
  • 본 연구에서는 탱크 내에 부분적으로 적재되어 있는 액체화물의 유동문제를 유한차분법을 이용해 해석하였다. 자유표면의 변화를 추적하고 유체장 내의 연속방정식과 Navier-Stokes 방정식을 만족시키기 위해 SOLA-SURF 기법이 적용되었다. 특히, 심한 유동으로 인한 탱크 상부에서의 충격압력을 예측하기 위해 충격완화영역의 개념을 도입하여 갑작스런 경계조건의 변화를 억제함으로써, 보다 현실적인 압력값을 예측할 수 있도록 하였다. 수치계산에서는 실험결과가 알려진 세가지 모델들에 대한 계산을 수행하였는데, 계산결과가 실험결과에 비교적 잘 일치하고 있었다. 그리고, 이 기법의 실선적용에 대한 가능성을 살펴보기 위해 30만톤급 초대형 유조선에 대한 실선계산도 수행하였다. 이러한 적용을 바탕으로 본 연구에서 적용된 수치기법이 sloshing 충격압력의 추정에 실용적으로 적용할 수 있음들 확인하였다.

  • PDF

동하중을 받는 원통형 액화연료 탱크의 배플에 따른 슬로싱 저감 특성 (Sloshing Reduction Characteristics to Baffle for Cylindrical Liquefied Fuel Tank subject to Dynamic Load)

  • 구준효;조진래;정의봉;김당주
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.950-959
    • /
    • 2009
  • Liquid fluctuation called sloshing within liquid-storage tank gives rise to the significant effect on the dynamic stability of tank. This liquid sloshing can be effectively suppressed by installing baffles within the tank, and the suppression effect depends strongly on the design parameters of baffle like the baffle configuration. The present study is concerned with the parametric evaluation of the sloshing suppression effect for the CNG-storage tank, a next generation liquefied fuel for vehicles, to the major design parameters of baffle, such as the baffle configuration, the installation angle and height, the hole size of baffle. The coupled FEM-FVM analysis was employed to effectively reflect the interaction between the interior liquid flow and the tank elastic deformation.

산화제 충진 및 대기 과정의 추진제 공급배관 내부 현상 (Liquid Oxygen in Feeding Line during Propellant Filling and Holding)

  • 권오성;조남경;정용갑;이중엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.34-37
    • /
    • 2007
  • 액체산소를 작동유체로 하여 추진제 공급배관에 대한 충진 및 대기 시험을 수행하였다. 추진제 공급 시스템은 추진제 탱크의 출구에 필터가 장착된 형상이다. 추진제의 충진이 완료된 후 대기 과정동안 액체산소의 증발과 이것이 시스템의 재순환 성능에 미치는 영향을 살펴보았다. 추진제의 충진 속도와 탱크 얼리지의 압력이 배관 내 액체산소의 상태에 영향을 미치는 것을 확인하였다. 필터의 장착 위치로 인해 대기 과정동안 배관 내부에서 geysering 현상은 발생하지 않았다.

  • PDF

유체의 영향을 고려한 프리스트레스트 액체저장 탱크의 동적해석 (Dynamic Analysis of Prestressed Liquid Storage Tanks Considering Fluid Effect)

  • 황철성;백인열
    • 한국지진공학회논문집
    • /
    • 제3권4호
    • /
    • pp.71-82
    • /
    • 1999
  • 자오방향 및 주변방향으로 프리스트레스트 하중이 작용된 축대칭 쉘 구조물을 축대칭요소로 모델화하였다 유체-구조물의 상호관계는 접촉면에서 구조물의 가속도에 비례한 부가질량으로 표현하였으며 부가질량은 유체를 비점성 비압축 및 비회전으로 가정하여 유한요소법에 의해 구하였다. 이에 대한 수치해석을 통하여 고유진동해석 및 지진하중을 주하중으로 한 동적해석을 실시하였다 이때 기하학적으로 축대칭인 구조물의 특성을 최대한으로 이용할 수 있도록 쉘을 링요소로 모델링하였으며 기하학적 비선형관계식에 의하여 동적 모형식을 유도하였다 프로그램을 통하여 해석한 결과를 프리스트레스하중 하에서 고유진동수에 대한 정해와 비교한 결과 20개 이내의 링요소로 모델링한 경우에서도 정해와 근접한 해를 얻을수 있었으며 내부유체가 있는 경우에 대한 고유진동수를 문헌과 비교한 결과 근접한 해를 얻을 수 있었다 내부유체의 높이의 증가에 따라 고유진동수는 현저히 감소하였으며 Wave Number가 적을수록 감소폭이 크게 나타났다. 지진하중에 대한 반경방향의 처짐을 해석한 결과 동일한 크기의 프리스트레스하중이 작용될 때 자오방향의 프리스트레스하중이 작용될 경우가 다소 큰 처짐값을 나타내었다.

  • PDF