A Study on Numerical Technique of the Hardened Grout Formed by Grouting (약액주입 시 형성된 고결체의 수치해석 기법 연구)

  • Lee, Jong-Hwi;Chun, Byung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.6
    • /
    • pp.27-37
    • /
    • 2011
  • Recently, pressure grouting is widely being used in construction site for strength improvement of ground and water proof, reinforcement and so on. It is necessarily required to estimate an appropriate injection pressure and injection time for economical and reasonable construction in the site through the size and shape of the hardened grout measured according to ground condition. However, sampling for the hardened grout is time-consuming and needs high cost on preliminary test in the site. The system which could predict the size and shape of the hardened grout does not exist until now. Thus, numerical method based on VOF method and porous model was used for the calibration chamber injection test with injection pressure (50 kPa, 100 kPa, 150 kPa) in this study. The results indicate that the numerical technique based on VOF method and porous model among CFD analysis is expected to be a basic study for the prediction of the behavior and solidification of pressure grouting.

The Effect of the Surfactant on the Migration and Distribution of Immiscible Fluids in Pore Network (계면활성제가 공극 구조 내 비혼성 유체의 거동과 분포에 미치는 영향)

  • Park, Gyuryeong;Kim, Seon-Ok;Wang, Sookyun
    • Economic and Environmental Geology
    • /
    • v.54 no.1
    • /
    • pp.105-115
    • /
    • 2021
  • The geological CO2 sequestration in underground geological formation such as deep saline aquifers and depleted hydrocarbon reservoirs is one of the most promising options for reducing the atmospheric CO2 emissions. The process in geological CO2 sequestration involves injection of supercritical CO2 (scCO2) into porous media saturated with pore water and initiates CO2 flooding with immiscible displacement. The CO2 migration and distribution, and, consequently, the displacement efficiency is governed by the interaction of fluids. Especially, the viscous force and capillary force are controlled by geological formation conditions and injection conditions. This study aimed to estimate the effects of surfactant on interfacial tension between the immiscible fluids, scCO2 and porewater, under high pressure and high temperature conditions by using a pair of proxy fluids under standard conditions through pendant drop method. It also aimed to observe migration and distribution patterns of the immiscible fluids and estimate the effects of surfactant concentrations on the displacement efficiency of scCO2. Micromodel experiments were conducted by applying n-hexane and deionized water as proxy fluids for scCO2 and porewater. In order to quantitatively analyze the immiscible displacement phenomena by n-hexane injection in pore network, the images of migration and distribution pattern of the two fluids are acquired through a imaging system. The experimental results revealed that the addition of surfactants sharply reduces the interfacial tension between hexane and deionized water at low concentrations and approaches a constant value as the concentration increases. Also it was found that, by directly affecting the flow path of the flooding fluid at the pore scale in the porous medium, the surfactant showed the identical effect on the displacement efficiency of n-hexane at equilibrium state. The experimental observation results could provide important fundamental information on immiscible displacement of fluids in porous media and suggest the potential to improve the displacement efficiency of scCO2 by using surfactants.

Experimental Measurement of Hydrodynamics and CFD Simulation of Circulating Fluidized Bed for MTO Process (MTO 공정을 위한 상온 순환유동층 장치의 수력학적 특성의 측정 및 유동모사)

  • Lim, Jonghun;Lee, Donghyun;Park, Sangsoon;Chae, Hojeong;Jeong, Soonyong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.163.1-163.1
    • /
    • 2010
  • MTO 공정을 개발하기 위한 순환유동층 장치에서 고체순환량을 높이기 위해 고체 주입량 및 상승관 유속에 따른 수력학적 특성의 파악에 관한 연구를 수행하였다. 전체 높이 2.6m 직경 0.009m의 상승관을 가진 순환유동층 장치에 대해 고체순환량을 조절하기 위한 비기계적 밸브로 각각 Seal-pot과 L-valve가 장착된 두 장치에 대해 고체순환량 및 체류량을 측정하였다. 고체순환량 및 체류량은 두 장치에서 모두 고체의 주입량이 증가함에 따라 증가하는 모습을 나타내었으며, 상승관의 유속에 따라서는 특정한 유속의 범위 내에서 증가하다가 일정 유속 이후 감소하는 모습을 나타내었다. Seal-pot을 사용한 장치에서는 고체순환량이 최대 $87kg/m^2.s$ 가량의 값을 나타내었으나 L-valve를 사용한 장치에서는 최대 $180kg/m^2.s$를 보였다. 이러한 실험 결과를 바탕으로 하여 전산유체역학을 이용한 순환유동층의 유동해석에 관한 연구를 실시하여 실험조건의 변화에 따른 상승관 내부의 수력학적 특성을 비교하였다.

  • PDF

Development of an Implantable Drug Infusion Pump for Pain Control in Cancer Patients (암 환자 통증 조절을 위한 이식형 약물 주입 펌프 개발)

  • Bach, Du-Jin;Park, Jun-Woo;Hong, So-Young;Lee, Chul-Han;Kim, Kwang-Gi;Jo, Yung-Ho;Kim, Dae-Hyun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.3
    • /
    • pp.31-37
    • /
    • 2009
  • This paper presents a implantable intrathecal drug infusion pump for pain control in cancer patients. This device consists of micropump module, drug reservoir module and control module. The micropump module using cam-follower mechanism composed of small-sized four cams and four followers. Each followers is driven by a cam and liquid is discharged by a sequential reciprocal motion of the followers. The advantage of this structure is that it allows the pump to be clean and valveless. The drug reservoir module composed of drug chamber, gas chamber and diaphragm. The control module composed of battery, wireless communication unit and controller. To design a small-sized, low power pump some analysis were performed to determine the design parameters. To verify the feasibility of the experiment, a prototype was manufactured and its operating characteristics were investigated. Experimental results were in accordance with the expected results obtained from analysis.

Effects of the angle of secondary air inlet on the uniformity of temperature distribution inside an incinerator (2차 공기 주입각이 소각로 내부의 온도 분포 균일도에 미치는 영향)

  • Kim S. J.;Min I. H.;Park M. H.;Park M. J.
    • Journal of computational fluids engineering
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 2000
  • This research is aimed to find out how the inlet angle of secondary air affects the uniformity of temperature distribution inside a small incinerator. A commercial code, PHOENICS, is used to simulate the thermal-flow field of an incinerator. The computational grid system is constructed by Multi-Block technique provided by PHOENICS. Numerical experiments are done with the five different angles of secondary air inlet. The uniformity of temperature distribution is evaluated by checking the standard deviation of temperature distribution in an incinerator. The computational results show that there is the minimum value of standard deviation at the certain angle of secondary air inlet, which means that there is an optimum angle of secondary air inlet that could improve the uniformity of temperature distribution in an incinerator. The optimum angle of secondary air inlet is between 30 degree and 45 degree in this particular case.

  • PDF

THE ANALYTIC ANALYSIS OF THE CORE INJECTION COOLING FLOW RATE FOR EMERGENCY WATER SUPPLY SYSTEM IN HANARO (하나로 비상 보충수 공급계통의 노심 주입 냉각유량 해석)

  • Park Yong-Chul;Kim Bong-Soo;Kim Kyung-Ryun;Wu Jong-Sub
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.39-44
    • /
    • 2005
  • In HANARO, a multi-purpose research reactor of 30 MWth, the emergency water supply system consists essentially of an emergency water storage tank located in the level of about thirteen meter (13 m) above the reactor core, a three inch ('3\%') diameter water injection pipe line including injection valves from the tank to the reactor cooling inlet pipe and a test loop to do periodic system performance test. When the water level of the reactor pool comes down to the extremely low due to a loss of reactor pool water accident the emergency water stored in the tank should be fed to the core by the gravity force and at that time the design flow rate is eleven point four kilogram per second (11.4 kg/s). But it is impossible periodically to measure the injection flow rate under the emergency condition because the normal water level should be maintained during the reactor operation. This paper describes a flow network analysis to simulate the flow rate under the emergency condition. As results, it was confirmed through the analysis results that the calculated flow rate agrees with the design requirement under the emergency condition.

  • PDF

A Study on Spray Angle of Dual Swirl Injector with Different Recess Length (Dual Swirl Injector Recess 길이에 따른 분산각 평가)

  • Park, Hee-Ho;Kim, Tae-Han;Kim, Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.3
    • /
    • pp.30-37
    • /
    • 2003
  • Spray angle of dual swirl injector is established according to the velocity ratio at orifice exit. Due to the internal mixing at recess and lack of correlation for the combined two fluid injection, prediction of spray angle is very difficult. This study deal with experimental work and numerical simulation on spray angle with different recess length. Among the multiphase flow models, the VOF model was selected to simulate the spray angle. Feasibility of numerical analysis are confirmed by comparing the results with the experimental data, and the effect of recess on spray angle are analyzed for single and combined spray case.

Injection of a Denser Fluid into a Rotating Cylindrical Container Filled with Homogeneous Lighter Fluid (균질의 회전유체에 고밀도유체 주입실험)

  • 나정열;황병준
    • 한국해양학회지
    • /
    • v.30 no.4
    • /
    • pp.355-364
    • /
    • 1995
  • A heavy fluid is injected to a rotating cylindrical container of flat or inclined bottom filled with homogeneous lighter fluid. Continuous flow-in and spreading patterns over the bottom of the container are observed and at the same time upper-layer motions induced by the movement of the heavy fluid are traced by thymol blue solution. Regardless of bottom geometry, the injected denser fluid is deflected toward "western wall" and continuous its path along the boundary with radial spreading which occurs in the bottom boundary layer to make a quite asymmetric flow. When the bottom contains a slope(${\beta}$-plane), increased pressure gradient causes the fluid move faster to produce a stronger Coriolis force. This makes the width of the flow narrower than that of f-plane. But, when the denser flow reaches the southern part of the container, a local-depth of denser fluid increases (much greater than the Ekman-layer depth) such that the spreading velocity along the wall is reduced and the interfacial slope increases to make the upper-layer adjust geographically to have oppositely directed upper-layer motion along the interfacial boundary. The role of the denser fluid in terms of vorticity generation in the upper-layer is such that it produces local topographic effect over the western half of the container and also induces vortex-tube stretching which is especially dominant in the f-plane.

  • PDF

Use of an Imaging Technology for Characterizing Core-scale Multiphase Flow: Application to CO2 Geological Storage (이미징기술을 활용한 코어규모의 다상유체 유동 특성화: 이산화탄소 지중저장 연구에의 적용)

  • Kim, Kue-Young
    • The Journal of Engineering Geology
    • /
    • v.28 no.1
    • /
    • pp.35-45
    • /
    • 2018
  • Imaging technologies are applied at various geological scales including pore scale, core scale and intermediate scale in order to characterize pore space of rocks as well as to map the fluid distribution in porous media. This technical report presents experimental results using core-flooding apparatus suited with imaging technology. Three different core samples, that are homogeneous, fractured and heterogeneous cores, were used to assess the two-phase fluid migration behavior as $CO_2$ displaces resident brine. We show that imaging technology can be effective in characterizing salt-precipitation, capillary pressure and spatio-temporal variation of trapping mechanisms.

Design Concept of Hybrid SIT (복합안전주입탱크(Hybrid SIT) 설계개념)

  • Kwon, Tae-Soon;Euh, Dong-Jin;Kim, Ki-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.104-108
    • /
    • 2014
  • The recent Fukushima nuclear power plant accidents shows that the core make up at high RCS pressure condition is very important to prevent core melting. The core make up flow at high pressure condition should be driven by gravity force or passive forces because the AC-powered safety features are not available during a Station Black Out (SBO) accident. The reactor Coolant System (RCS) mass inventory is continuously decreased by releasing steam through the pressurizer safety valves after reactor trip during a SBO accident. The core will be melted down within 2~3 hours without core make up action by active or passive mode. In the new design concept of a Hybrid Safety Injection Tank (Hybrid SIT) both for low and high RCS pressure conditions, the low pressure nitrogen gas serves as a charging pressure for a LBLOCA injection mode, while the PZR high pressure steam provides an equalizing pressure for a high pressure injection mode such as a SBO accident. After the pressure equalizing process by battery driven initiation valve at a high pressure SBO condition, the Hybrid SIT injection water will be passively injected into the reactor downcomer by gravity head. The SBO simulation by MARS code show that the core makeup injection flow through the Hybrid SIT continued up to the SIT empty condition, and the core heatup is delayed as much.