• Title/Summary/Keyword: 유착치

Search Result 89, Processing Time 0.03 seconds

ORAL MANIFESTATIONS OF THE AXENFELD-RIEGER SYNDROME (Axenfeld-Rieger 증후군의 치과적 소견)

  • Kang, Tae-Sung;Choi, Byung-Jai;Kim, Seong-Oh;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.3
    • /
    • pp.510-514
    • /
    • 2003
  • The Axenfeld-Rieger syndrome is a rare autosomal dominant disorder characterized by dental and ocular abnormalities. The essential ocular features include partial or complete bilateral hypoplasia of the iris stroma, abnormalities of the angle structures with congenital iris adhesions, and anterior displacement of Schwalbe's corpuscles. Common oral findings are hypodontia(especially in anterior maxillary segment), microdontia, misshaped teeth, delayed eruption of the teeth. Additionally, other systemic symptoms can be seen and early detection by the pedodontist through dental diagnosis should prevent visual impairment.

  • PDF

Temporomandibular Disorder Caused by Periapical Abscess of Third Molar (제 3 대구치의 치근단 농양으로 인한 측두하악장애)

  • Cho, Eunae;Kwon, Jeong-Seung;Ahn, Hyung-Joon;Kim, Seong-Taek;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.143-147
    • /
    • 2013
  • Mouth opening limitation is generally caused by masticatory muscle or temporomandibular joint pain, disc dislocation without reduction, adhesion or ankylosis of the temporomandibular joint, and muscle contracture. But otorhinolaryngologic disease, neurologic and vascular disease, tumor, inflammation and infection may cause pain and mouth opening limitation which mimics temporomandibular disorders. Re-evaluation for possibilities of inflammation, infection and tumor should be in cases that do not show symptom improvement or appear with continuous aggravation despite of proper treatment. In this case, we report of medial pterygoid muscle pain and mouth opening limitation caused by periapical abscess of third molar spread to the pterygomandibular space.

The experimental study of early loading on the Miniplate in the beagle dog (성견의 하악골에 식립된 Miniplate에 가한 조기 부하의 영향에 관한 실험적 연구)

  • Chung, Yong-Koo;Lee, Young-Jun;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.33 no.4 s.99
    • /
    • pp.307-317
    • /
    • 2003
  • Conventional osseointegrated titanium implants have many limitations; large size, limited location for placement of the implant, severity of the surgery, discomfort of initial healing, difficulty of oral hygiene and uncontrollable force direction. Recently titanium miniscrew and miniplate have been used for an alternative to conventional dental implant. But in relation to miniplate, miniscrew has disadvantages in that more potential inflammation, light orthodontic force application and limited orthodontic application. This study was conducted to evaluate the effectiveness of miniplate by observing the reactions of peri-implant tissues to early orthodontic and orthopedic loading of titanium miniplate. In four adult beagle dogs 10 miniplates were inserted into the alveolar bone using 20 osseointegrated titanium screws. 4 miniplates were placed in two dogs(dogA, B) and 6 miniplates in two dogs(dogC, D). In dogA, B miniplates were loaded with 200gm of force immediately after placement for 15 weeks. In dogc, D, miniplates were loaded with 400gm of force immediately after placement for 8 weeks. Miniplates of dogA were removed, dogA was healed for 4 weeks, and the area which was removed of miniscrew was examined. Following an observation period, the miniplates including miniscrews and the surrounding bone of dogB and dogC, D were removed, respectively. Undecalcified section along the long axis of miniscrews were made and the degree of osseointegration was examined under the light microscope. The results were as follows. 1. In the histologic features there was direct contact between bone and miniscrew in all groups except one, dogC control group. The loaded miniscrew demonstrated only a slight increase of the osseous proximaty when compared with unloaded miniscrew 2. There was no significant difference of the osseointegration of Peri-miniscrew surface between dogB and dogC, D. But dogB showed slightly more increased bone apposition than dogC, D 3. The gingiva overlapping the miniplate and miniscrew showed no inflammatory sign in clinical and histological aspects. 4. The impaled hard and soft tissues at the area which was removed of miniscrews showed good healing without inflammatory reaction. 5. The mobility showed slight increase in un-loaded miniplate but that was insignificant. Based on the results of this study, miniplate(C-tube) can be used as a firm osseous orthodontic and orthopedic anchorage unit immediately after insertion.

Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report (디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례)

  • Jeong, Dae Gil;Oh, Kyung Chul;Shim, June Sung;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.4
    • /
    • pp.397-404
    • /
    • 2019
  • Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the biological, esthetical and mechanical problems. In order to place an implant in the correct position, the final restoration and diagnostic wax-up should be considered prior to the surgery. If the artificial teeth for the interim denture are directly transferred from the diagnostic wax-up, the operator can try the form of diagnostic wax-up in the mouth. If the surgical template is produced by duplicating the interim denture, the implant can be placed in the planned position. In this case, the polymethyl methacrylate (PMMA) artificial tooth was precisely milled by the digital duplication of diagnostic wax-up. And interim denture was fabricated by using these milled teeth. After the patient adapted for a sufficient period, the implant was placed at the planned position with surgical template produced by duplicating the interim denture. After confirming sufficient osseointegration, the final prostheses were made to reflect the shape of diagnostic wax-up. Through this procedure, the satisfactory functional and esthetic outcome could be acquired.

Clinical Application for Video-Thoracoscopy in Lung Cancer Surgery Patients (폐암 수술환자에서 흉강경수술의 적용)

  • 김광호;한재열;윤용한;백완기;이응석;김형진
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.392-396
    • /
    • 2002
  • Background: Video-thoracoscopy is known to be an useful method to provide accurate pre-resectional staging in patients with lung cancer in addition to the conventional radiologic studies and mediastinoscopy, for the pleural cavity is inspected directly and biopsy specimens call be obtained. This study is undertaken to evaluate how video-thoracoscopy can be used in deciding pre-resectional stage Material and Method: Video-thoracoscopy was performed in patients with lung cancer who were scheduled for surgical resection based on the radiologic staging and mediastinoscopic biopsy. 37 patients were included in this study. Pre-thoracoscopically 18 cases were in TNM stage 1, 7 in stage 2, and 12 in stage 3. Result: In 15 of 37 cases, video-thoracoscopy could not be performed effectively due to heavy adhesions in the pleural cavity, diaphragmatic and chest wall invasion of tumor and bulky tumor mass es. Mediastinal lymph nodes were positive postresectionally in 6 of these 15 cases. In 22 cases, video-thoracoscopy was performed as usual. Positive mediastinal lymph nodes were identified in 2 cases and exploratory thoracotomy was prevented. Surgical resection were carried out in remaining 20 cases and 5 cases among them had positive mediastinal lymph nodes. Conclusion: We believe that it is difficult to perform pre-thoracotorny video-thoracoscopy for all lung cancer patients for there were many cases that thoracoscory could not be undertaken doe to heavy adhesions in the pleural cavity, tumor involvement of the chest wall and/or diaphragm and bulky tumor mass. However we think it is helpful in preventing unnecessary exploratory thoracotomy for some patients with lung cancer whom pre-thoracotomy video-thoracoscopy was carried out.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

ORTHODONTIC TRACTION AFTER THE TRAUMATIC INTRUSION OF UPPER CENTRAL INCISOR (외상에 의하여 함입된 상악 중절치의 교정적 견인)

  • Han, Yoon-Beum;Lee, Jae-Ho;Choi, Hyung-Jun;Sohn, Hyung-Kyu;Kim, Seong-Oh;Song, Je-Seon;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.2
    • /
    • pp.293-297
    • /
    • 2009
  • Traumatic intrusion is a type of injury that involves axial displacement of a tooth toward the alveolar bone. Its occurance is relatively rare compared to other types of luxation in permanent dentition. It is more common in boys than in girls, and most common etiology of intrusion is fallen down. Various complication may occur following traumatic intrusion, such as pulp necrosis, root resorption, pulp obliteration and marginal bone loss. In addition, traumatic intrusion is commonly combined with hard or soft tissue injuries. Therefore, it is difficult to establish proper treatment plan. Choice of treatment for an intruded tooth by trauma include waiting for spontaneous re-eruption, orthodontic repositioning, and surgical repositioning. In this case, we repositioned the intruded central incisor using orthodontic traction, in a six-year old girl, which failed to re-erupt spontaneously.

  • PDF

The effects of noncrystalline calcium phosphate glass on the healing of 1-wall intrabony defects in beagle dogs (비결정성 calcium phosphate가 성견의 1면 골내낭에서의 치주조직 재생에 미치는 영향)

  • Baik, Dong-Hoon;Hwang, Sung-Joon;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.113-126
    • /
    • 2004
  • 연구목적 : 이번 실험의 목적은 외과적으로 형성된 성견의 1면 골내낭에 새롭게 제조된, Ca/P 비율이 0.6인 비결정성 calcium phosphate를 적용하였을 때 치주조직의 재생에 미치는 영향을 평가하는 것이다. 연구방법 : 6마리 성견의 양측 하악 제2소구치의 원심면, 제4소구치의 근섬면에 외과적으로 1면 골내낭을 형성하여 치은박리소파술을 시행한 부위를 대조군으로, calcium phosphate만을 이식한 부위를 실험 1군, calcium phosphate와 GTR을 동반한 부위를 실험 2군으로 설정하고 실험하여 술 후 8주에 치유결과를 조직학적으로 관찰하였다. 결론 : 1. 접합상피의 치근단 이동은 대조군에서 결손부 깊이의 30.90 ${\pm}$ 9.92%, 실험 1군에서 결손부 깊이의 24.08 ${\pm}$ 9.12%, 실험 2군에서 결손부 깊이의 38.68 ${\pm}$ 12.22%로 나타났으며 대조군과 실험 1,2군간에 통계적 유의차는 없었다. 2. 결합조직 유착은 대조군에서 결손부 깊이의 36.38 ${\pm}$ 9.03%, 실험 1군에서 결손부 깊이의 26.96 ${\pm}$ 4.24%, 실험 2군에서 결손부 깊이의 27.87 ${\pm}$ 9.70%로 나타났으며 대조군과 실험 1,2군간에 통계적 유의차는 없었다. 3. 신생백악질 형성은 대조군에서 결손부 깊이의 32.92 ${\pm}$ 10.51%, 실험 1군에서 결손부 깊이의 49.16 ${\pm}$ 12.70%, 실험 2군에서 결손부 깊이의 39.62 ${\pm}$ 12.14%로 나타났으며 대조군과 실험 1군간에 통계적 유의차가 있었다. 4. 신생골 형성은 대조군에서 결손부 깊이의 27.24 ${\pm}$ 7.49%, 실험 1군에서 결손부 깊이의 43.51 ${\pm}$ 13.34%, 실험 2군에서 결손부 깊이의 36.47 ${\pm}$ 15.11%로 나타났으며 대조군과 실험 1, 2군간에 통계적 유의차는 없었다. 이상의 결과에서 볼 때, calcium phosphate glasses는 신생골 형성에는 통계적으로 유의차는 없었지만 상당히 증가된 양상을 보였고 신생백악질 형성에는 크게 기여함을 알수 있었다.

FINITE ELEMENT STRESS ANALYSIS OF MAXILLARY TWO IMPLANTS-RETAINED OVERDENTURE ACCORDING TO POSITION OF IMPLANT FIXTURES (상악피개의치를 위한 임플랜트의 위치에 따른 응력분포에 대한 유한요소분석)

  • Ha, Heon-Seok;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.193-200
    • /
    • 2008
  • Statement of problem: There have been a few studies about unsplinted implant retainted maxillary overdenture. Purpose: The purpose of this study was to examine the effect of different position of implant for 2 implants-retained maxillary overdenture. Materials and methods: Three-dimensional finite element models were used to reproduce an edentulous human maxilla with an implant-retained overdenture. Two implants in the canine tooth positions on both side and in the second premolar tooth positions on both side models were examined. Axial loads of 100 N were applied to the occlusal surface at the right first molar tooth positions. Maximum stress at the implant-bone interface and stress at the cortical bone surface just under the loading point were observed. Results and conclusion: Within the limits of this study, maximum stresses were concentrated around implant of canine position at loading side. The second premolar area was thought to be more favorable to distribution of stress on mucosa, alveolar bone and implants than canine area for maxillary overdenture.

The Effect of the Extents of Pleural Thickening in Tuberculous Pleurisy on the Impairment of Pulmonary Function (흉막비후의 정도가 폐기능에 미치는 영향)

  • Lee, Young-Kyoung;Na, Moon-Jun;Yun, Bo-Ra;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.3
    • /
    • pp.240-247
    • /
    • 2001
  • Background : Tuberculous pleurisy treatments improve symptoms such as fever, chest pain, cough, and prevents the progression to active pulmonary tuberculosis and the development of residual pleural thickening that decrease diaphragm and rib cage movement This study investigated how the degree of residual pleural thickening affects the pulmonary function. Methods : Fifty seven patients who were initially diagnosed as having tuberculous pleurisy, were treated with anti-tuberculous medication for 6 months and had residual pleural thickening between May 1998 and January 2000 at the Eulji university hospital were reviewed. A chest X-ray and pulmonary function test(PFT, Sensormedics 2200) were performed. The predicted value(%) of the forced vital capacity(FVC), forced inspiratory vital capacity(FNC) and total lung capacity(TLC) were measured. The residual pleural thickening was defined the average of the summation in the lateral chest at the level of the imaginary line intersecting from the cardiophrenic angle to the diaphragmatic dome and the lowest part of the costophrenic angle between them. The results were sorted into three grades according to pleural thickness ; <2mm(grade I), 2~10mm(grade II), 10mm(grade III). Results : 1. FVC(% pred) and FIVC(% pred) were statistically different between grade I and III, and II and III. However, there was no difference between the TLC(% pred) between each of the groups. 2. The pleural thickness that cause restrictive dysfunction(FVC<80%) and a statistically difference, is 3mm. Conclusion : The larger the extent of the residual pleural thickness after antituberculous medication, the greater the reduction in the FVC, FIVC, TLC. A pleural thickness of 3mm is recommended as a guideline for diagnosing a restrictive pulmonary dysfunction.

  • PDF