• Title/Summary/Keyword: 유사 단위중량

Search Result 49, Processing Time 0.027 seconds

Fundamental Properties of Porous Concrete According to the Sizes of Aggregate (골재 크기에 따른 포러스콘크리트의 기초물성에 관한 실험적 연구)

  • 김무한;백용관;강석표;김용로;김재환
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.5
    • /
    • pp.438-446
    • /
    • 2001
  • Recently, porous concrete has been used for the purpose of decreasing the load of earth environment. It consists solely of cement, water and uniform-sized coarse aggregate. And its fundamental properties will be considerably affected by the physical properties of aggregate because the aggregate occupies for the most part in its mix proportion. For such a reason, this study was carried out to investigate the influence of the sizes and kinds of aggregate for the fundamental properties of porous concrete. It showed that the fundamental properties of porous concrete were the similar value in all sizes of aggregate except in the case of using the 2.5∼5㎜ aggregate and were varied according to the kinds of aggregate. In particular, compressive strength of porous concrete using 2.5∼5㎜ aggregate was more higher than that using other aggregate, and its void ratio and coefficient of permeability was lower. And the maintenance capacity of permeability of porous concrete was varied by the sizes and the kinds of aggregate. In particular, it was greatly decreased in case of using the 2.5∼5㎜ aggregate. And unlike dynamic modulus of elasticity of ordinary concrete, that of porous concrete was very high value in early ages and was slowly increased after that time.

A study on the estimation of unit load generation and discharge from livestock resources of piggery (돼지 축분자원화물의 발생 및 배출부하 원단위 산정에 관한 연구)

  • Han, Gee-Bong;Kang, Young-Hee;Yoon, Ji-Hyun;Rim, Jay-Myoung;Won, Chul-Hee;Choi, Seung-Chul
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.3
    • /
    • pp.91-100
    • /
    • 2006
  • In this study, the characterization of unit load generation and discharge from various type stall of piggery was conducted by investigation and analysis of contaminants loading from piggery urine, manure and wastewater. The results are summarized as follows: The unit load generation of filth increases as piggery grow older, but there was not large enough difference among those values of unit load evaluated for various stall types if mean values of each type of stall are considered. The generation amounts of manure and urine were total 4.57kg/head/d of 1.49kg manure/head/d and 3.08kg urine/head/d with consideration of 3 seasons and live weight. The finalized mean unit load generation of filth were estimated at BOD 199.5g/head/d, $COD_{cr}\;413.5g/head/d$, T-N 27.8g/head/d, T-P 5.3g/head/d with consideration of seasons and the type of stalls. The wastewater unit loads discharged from cement type stall were estimated at BOD 31.3g/head/d, $COD_{cr}\;95.6g/head/d$, T-N 8.9g/head/d, T-P가 3.1g/head/d. The sum of manure unit load generation considered with manure collection ratio(80%, 90%) and wastewater unit load was almost similar when compared to the unit load discharged from slurry type stall even though more or less difference were appeared according to each contaminants and parameters.

  • PDF

Analysis of Deformation and Stability of Slope at the Wiri Region of Local Road 999 Nearby Andong, Gyeongsangbukdo in Korea. (999번 지방도로 경상북도 안동시 위리 지역의 사면 변형 및 안정성 분석)

  • 장현식;장보안
    • The Journal of Engineering Geology
    • /
    • v.10 no.1
    • /
    • pp.1-12
    • /
    • 2000
  • Heaving of road and subsidence of slope took place at the Wiri region of the local highway 999 in Gyeongsangbukdo, Korea after heavy rain in the next year of construction. Although the state government had performed remedial treatments by reducing the angle and the height of the slope, deformation had never stopped. Therefore, we have preformed the analysis of deformation and stabilityof the slope. Study area consists of the Cretaceous shale, siltstone and sandstone and two faults are found. The major deformation occurred by sliding of rock mass along faults after heavy rain because not only thepore pressure at the fault plane and the unit weight of sliding mass increased, but did the shearstrength of saturated fault clay become very low. The decrease in shear strength of saturated fault clayis the major factor among the reasons for deformation. Numerical simulations using limit equilibriummodel, finite difference model and finite element model were performed for eight cross sections.Although safety factors are above 1.7 during the dry season, they become below 1.0 when groundwaterlevel raises to surface. The maximum displacement is about 15-3Ocm. However, safety factors increasedto above 2.4 and the maximum displacement is below 2.08cm after remedial treatment, Indicating thatthe slope becomes stable.

  • PDF

Sensitivity of Hydraulic Structures Design Parameter by Climate Change (기후변화에 의한 수공구조물 설계인자 민감도 연구)

  • Kong, Jung-Sik;Kim, UlAnYi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.419-419
    • /
    • 2011
  • 이상호우, 사막화, 빙하융해, 생태계 먹이사슬 변화, 이상기온 등 기후변화의 행태는 지구 곳곳에서 다양하게 발발되고 있으며 그로인해 발생되는 인적 물적 피해가 심각하다. 1996년 집중호우에 의한 연천댐체 파괴, 2002년 8월의 낙동강 유역 장기홍수, 2002년 태풍 루사 및 2003년 태풍 매미 등 국내에서는 기후변화 중에서도 주로 이상호우로 인해 발생하는 피해가 많았으며 이들은 주기성이나 특성을 갖지 않아 예측이 어려운 관계로 망양보뢰 식의 후처리에 급급한 실정이었다. 최근 기후변화에 따른 지역별 홍수량, 가뭄량 등에 관한 연구가 가속화되고 있으며, 이와 더불어 해당 기후모델 발현 시 기존 구조물에 미치는 영향에 대한 연구도 필수적이다. 나아가 기존 구조물 뿐 아니라 새로 시공되는 구조물의 설계에서 기후변화에 대한 안정성을 위해 추가적으로 포함해야 할 요소가 있는지에 대한 연구도 필요하다. 본 연구에서는 가상 기후모델에 대해 그 모델이 예측하는 홍수량이 실제 발현되었을 경우를 가정하여, 기존 수공구조물의 안정성에 미치는 영향을 살펴보고 영향인자의 민감도를 분석하고자 한다. 대상 수공구조물은 붕괴 시 영향력이 큰 정도를 기준으로 필댐, 콘크리트차수벽형석괴댐(CFRD), 콘크리트중력식댐, 제방으로 그 범주를 제한 하였으며 대상유역은 한강으로 가정하였다. 구조물의 안정성 검토방법은 각 구조물의 종류에 따라 상이하다. 흙이 주 재료인 제방과 필댐의 경우, 침투(Piping)와 비탈면(Sliding)에 대한 안정성 평가가 이루어지며 CFRD는 댐체와 벽체로 나누어 안정성평가를 하며 댐체 안정성 평가방법은 필댐과 유사하다. 본 연구에서는 하천설계기준(2009)과 댐설계기준(2005)에 따라 각 구조물의 기준안전율을 책정하였으며 점착력, 내부마찰각, 단위중량 등의 물성치는 해당 지역의 토질특성에 따라 여러 문헌을 참고하여 설정하였고 이를 SEEP/W, SLOPE/W 프로그램을 이용하여 구조해석을 실시하였다. 콘크리트중력식댐은 활동, 전도, 지지력에 대해 각각 안정성을 평가하며 MIDAS와 ABAQUS 프로그램을 병행하여 해석하였다. 민감도(Sensitivity)란 안정성에 영향을 미치는 설계인자들의 변화에 따라 안정성이 어떻게 변화하는 지를 말한다. 기후변화에 의한 수공구조물 설계인자 민감도 연구를 통해 기존 설계과정 또는 안정성 검토 시 해당인자의 기여도를 높이거나 새로운 설계인자를 추가하여 미래 상황에 대한 구조물의 위험 정도를 과거대비 상세히 예측할 수 있으며 나아가 적절한 대응 방안 제시에 기여하여 기후변화에 따른 피해를 감소할 수 있을 것이라고 생각된다.

  • PDF

Engineering Properties of Concrete with Rice-Straw Ash (볏짚재를 혼입(混入)한 콘크리트의 공학적(工學的) 성질(性質))

  • Sun, Chan Yong;Lee, Hee Man;Kim, Young Ik;Kim, Kyung Tae;Seo, Dae Seuk;Nam, Ki Sung
    • Korean Journal of Agricultural Science
    • /
    • v.25 no.2
    • /
    • pp.285-292
    • /
    • 1998
  • This study was performed to evaluate the engineering properties of concrete using normal portland cement, natural aggregates and rice-straw ash. The following conclusions were drawn; 1. The unit weight was in the range of $2,250{\sim}2,335kgf/m^3$, the weights of those concrete were decreased 1~5% than that of the normal cement concrete, respectively. 2. The highest strength was achieved by 5% rice-straw ash filled rice-straw ash concrete, it was increased 17% by compressive strength, 30% by tensile strength and 21% by bending strength than that of the normal cement concrete, respectively. 3. The ultrasonic pulse velocity was in the range of 4,059~4,360m/s, which was showed about the same compared to that of the normal cement concrete. The highest ultrasonic pulse velocity was showed by 5% rice-straw ash filled rice-straw ash concrete. 4. The acid-proof was increased with increase of the content of rice-straw ash. The acid-proof was increased 1.15 times by 5% rice straw ash, 1.45 times by 10%, 1.6 times by 15% rice-straw ash filled concrete than that of the normal cement concrete, respectively.

  • PDF

Physical and Mechanical Properties of Synthetic Lightweight Aggregate Concrete (인공경량골재(人工輕量骨材) 콘크리트 물리(物理)·역학적(力學的) 특성(特性))

  • Kim, Seong Wan;Min, Jeong Ki;Sung, Chan Yong
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.182-193
    • /
    • 1997
  • The normal cement concrete is widely used material to build the construction recently, but it has a fault to increase the dead load on account of its unit weight is large compared with strength. Therefore, many engineers are continuously searching for new materials of construction to provide greater performance at lower density. The main purpose of the work described in this paper were to establish the physical and mechanical properties of synthetic lightweight aggregate concrete using perlite on fine aggregate and expanded clay, pumice stone on coarse aggregate. The test results of this study are summarized that the water-cement ratio was shown 47% using expanded clay, 56% using pumice stone on coarse aggregate, unit weight was shown $l,622kgf/m^3$ using expanded clay, $l,596kgf/m^3$ using pumice stone on coarse aggregate, and the absorption ratio was shown same as 17%. The compressive strength was shown more than $228kgf/cm^2$, tensile and bending strength was more than $27kgf/cm^2$, $58kgf/cm^2$ at all types, and rebound number with schmidt hammer was increased with increase of compressive strength. The static modulus was $1.12{\times}10^5kgf/cm^2$ using expanded clay, $1.09{\times}10^5kgf/cm^2$ using pumice stone on coarse aggregate, and stress-strain curves were shown that increased with increase of stress, and the strain on the maximum stress was shown identical with $2.0{\times}10^{-3}$, approximately.

  • PDF

The Case Study on Risk Assessment and Probability of Failure for Port Structure Reinforced by DCM Method (심층혼합처리공법이 적용된 항만 구조물의 파괴확률과 위험도 평가에 관한 사례 연구)

  • Kim, Byung Il;Park, Eon Sang
    • Journal of the Korean Geosynthetics Society
    • /
    • v.17 no.4
    • /
    • pp.53-64
    • /
    • 2018
  • In this study, the evaluation to probability of failure for risk assessment of port structures on DCM reinforced soils, where stability and risk assessment are increasing in importance, was performed. As a random variables affecting the risk of DCM improved ground, the design strength, superposition (overlap) of construction, strength of the natural ground, internal friction angle and unit weight of the modified ground were selected and applied to the risk assessment. In addition, the failure probability for the entire system under ordinary conditions and under earthquake conditions were analyzed. As a result, it was found that the highest coefficient of variation in the random variable for the risk assessment of the DCM improved ground is the design strength, but this does not have a great influence on the safety factor, ie, the risk of the system. The main risk factor for the failure probability of the system for the DCM reinforced soils was evaluated as horizontal sliding in case of external stability and compression failure in case of internal stability both at ordinary condition and earthquake condition. In addition, the failure probability for ordinary horizontal sliding is higher than that for earthquake failure, and the failure probability for ordinary compression failure is lower than that for earthquake failure. The ordinary failure probability of the entire system is similar to the failure probability on earthquake condition, but in this case, the risk of earthquake is somewhat higher.

Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus (동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구)

  • Jin, Hyunwoo;Ryu, Byunghyun;Lee, Jangguen
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Frost heave is one of the representative engineering characteristics in cold regions. In South Korea, which is located in seasonal frost area, structural damage caused by frost heave and thaw happens and the need for research on the frost heave is increasing. In this paper, newly developed transparent temperature-controllable cell is used to focus on the frost heave. Frost susceptible artificial soil is used to analyze water intake rate which is one of the important factors in frost susceptibility criteria. Frost heave rate and water intake rate have similar behavior after heave by freezing of pore water converges. O-ring installed in the upper pedestal to measure water intake rate generates side friction between the inner wall of the freezing cell and O-ring, thereby hindering frost heave. Therefore, the frost susceptibility criteria using the water intake rate is not reliable. It is appropriate to use frost heave rate which has similar behavior with water intake rate. Frost heave tests were performed under two different specimen heights. Overburden pressure, temperature gradient and dry unit weight were set under similar state. Based on laboratory testing results, frost heave is independent on the specimen height.

An Experimental study on the Engineering Properties of Concrete with Rice-Husk Ash (왕겨재를 혼입(混入)한 콘크리트의 공학적(工學的) 특성(特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Sung, Chan Yong;Yoo, Byong In;Kim, Kyung Tae;Jung, Hyun Jung;Kim, Young Ik
    • Korean Journal of Agricultural Science
    • /
    • v.24 no.2
    • /
    • pp.207-217
    • /
    • 1997
  • This study was performed to evaluate the engineering properties of rice-husk ash concrete using normal portland cement, natural aggregates and rice-husk ash. The following conclusions were drawn; 1. The unit weight was in the range of $2,216{\sim}2,325kgf/m^3$, the weights of those concrete were decreased 1~6% than that of the normal cement concrete, respectively. 2. The highest strength was achieved by 10% rice-husk ash filled rice-husk ash concrete, it was increased 8% by compressive strength, 17% by tensile strength and 18% by bending strength than that of the normal cement concrete, respectively. 3. The ultrasonic pulse velocity was in the range of 3,252~4,016 m/s, which was showed about the same compared to that of the normal cement concrete. The highest ultrasonic pulse velocity was showed by 10% rice-husk ash filled rice-husk ash concrete. 4. The dynamic modulus of elasticity was in the range of $242{\times}10^3{\sim}306{\times}10^3kgf/cm^2$, which was showed about the same compared to that of the normal cement concrete. The highest dynamic modulus was showed by 10% rice-husk ash filled rice-husk ash concrete. 5. The static modulus of elasticity was in the range of $185{\times}10^3{\sim}275{\times}10^3kgf/cm^2$, which was showed about the same compared to that of the normal cement concrete. The poisson's number of rice-husk ash concrete was less than that of the normal cement concrete. The dynamic modulus was increased approximately 11~30% than that of the static modulus. 6. The durability was increased with increase of the content of rice-husk ash. The durability was increased 1.3 times by 10% rice-husk ash, 1.6times by 20% rice-husk ash filled concrete than that of the normal cement concrete. respectively.

  • PDF

Study on Torrefaction Characteristics of Solid Biomass Fuel and Its Combustion Behavior (바이오매스 고형연료의 반탄화 특성 및 반탄화물의 연소특성에 관한 연구)

  • Lee, Weon Joon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.4
    • /
    • pp.86-94
    • /
    • 2015
  • Torrefaction is a thermochemical process proceeded at the temperature around $250^{\circ}C$ in an inert gas condition. By torrefaction, the hemicellulose portions contained in biomass are broken down to change into the volatile gas which is removed from biomass eventually. The main purpose of biomass torrefaction is to improve the energy density of the biomass to minimize the transport energy consumption, though the flammability can be elevated for transportation. In this study two types of solid biomass fuel, waste wood and rice straw, were torrefied at various temperature range from $200^{\circ}C$ to $300^{\circ}C$ to evaluate the torrefied biomass characteristics. In addition torrefied biomass were tested to evaluate the combustion characteristics using TGA (Thermogravimetric Analysis). After the torrefaction of biomass, the C/H (carbon to hydrogen ratio) and C/O (carbon to oxygen ratio) were measured for aquisition of bio-stability as well as combustion pattern. Generally C/H ratio implies the soot formation during combustion, and the C/O ratio for bio-stability. By torrefaction temperature at $300^{\circ}C$, C/H ratio and C/O ratio were increased by two times for C/H and three times for C/O. The torrefied biomass showed similar TGA pattern to coal compared to pure biomass; that is, less mass decrease at lower temperature range for torrefied biomass than the pure biomass.