• Title/Summary/Keyword: 유방패드

Search Result 6, Processing Time 0.018 seconds

A Study on Development of Mammo Pad and Analysis of Factors Affecting Compression Pain for Mammography (유방 방사선 검사를 위한 압박 패드의 제작 및 유방 압박 통증에 영향을 주는 요인 분석)

  • Kim, Do-Hee;Yi, Ann;Kwon, Bo-Ra;Ku, Hong-Uk;Bang, Yong-Sik;Cho, Myeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.629-636
    • /
    • 2021
  • The purpose of this study was to identify the effects of mammo pad made of different kinds of materials on the reduced inconvenience and compression pains of patients to examine plausible interchangeability of existing pads made of single kind of material, and to examine the changes in pains of patients taking mammography and various factors therein. The high-hardness and highly-elastic mammo pressure pads, capable of replacing existing mammo pad of "H" company, were manufactured, and the display quality of mammography obtained from respective mammo pad were compared to each other to appraise the availability of manufactured mammo pad. In addition, 200 patients, who came to a general hospital in Seoul, were selected as subjects for the survey employing a questionnaire which was distributed to the subjects from December 2018 to March 2020 to identify the factors involved with the mammo pad of patients while taking mammography. The results of mammography obtained from both of the existing and newly manufactured mammo pad revealed appropriate display qualities fell within the range of clinical criteria. Besides, the factors associated with changing compression pains of patients taking mammography were analyzed wherefrom the general factors in the following order of age, height, and BMI index appeared, while the experiential and female factors appeared as in the following order: presence of menstruation, experience of child-birth, experience of breast feeding, menopause, grade of breast, shape of breast, and experience of mammography. In conclusion, the following factors comprising the age, experience of breast feeding, experience of mammography, and menopause rendered approximately 54% of power of explaining the degree of changing pains during mammography. Regarding the changes in compression pains while taking mammography, the increasing experience of mammography of patients rendered approximately 0.26 times more at the intermediate range of compression pains and approximately 0.14 times more at the range of severe pains.

Comparative Evaluation of Wearing Breast Volume-up Pads for Small-Breasted Women (작은 유방 여성을 위한 유방 볼륨업 패드의 비교 착의평가)

  • Yi, Kyong-Hwa
    • Journal of Fashion Business
    • /
    • v.26 no.3
    • /
    • pp.72-86
    • /
    • 2022
  • Volume-up pads are the most common and easiest way to make women with small breasts beautiful. In this study, to develop a volume-up brassiere pad with excellent wearing effects and appearance, 24 different types of volume-up pads commercially available in the online market were investigated and then 11 types were purchased. Among these eleven types, four pads (PAD1, PAD2, PAD3, PAD4) with distinct shapes and materials were selected through a pre-test. They were compared to the newly developed pad for research (PAD5). The results of the study follow. The results of evaluating appearance when wearing the developed pad (PAD5) were significantly higher than that of other pads, and the appearance evaluation score for the full-cup type pad was excellent. In the wearing satisfaction evaluation result, PAD5 showed generally excellent evaluation scores, and in the case of the touch, preference for the fabric material was higher than that of the silicon pad. In the evaluation of motion adaptability, the developed PAD5 showed generally excellent evaluation scores in all movements, indicating that the full-cup type pads had better motion adaptability than the partial-type pads.

Evaluation of New Material Mammopad (맘모패드의 새로운 재질에 관한 평가)

  • Moon, Young-Ju;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2019
  • Mammography is the most useful test for the early diagnosis of breast cancer. The MammoPad can be used for the purpose of reducing the pain felt by the patient due to the pressure of the breast. MammoPad cushion the pressure between the breasts and the equipment and reduce the patient's discomfort. A new material pad was fabricated to solve the problem of the H-pad which is currently in circulation. Quantitative evaluation of SNR and CNR and qualitative evaluation of imitation lesion using ACR Phantom were performed. In the quantitative evaluation, SNR and CNR of Non pad and Filter pad were not statistically significant.(p>0.05) In the qualitative evaluation, Fiber and Imitation lesion of H-pad and Filter pad were statistically significant(p<0.05), and all values of Calcification and Mass were not statistically significant. (p>0.05) In addition, Fiber, calcification, mass, and imitation lesion were not statistically significant in both Non pad and Filter pad.(p>0.05) Through this study, it was confirmed that the newly created Filter pad minimizes image quality degradation and can replace existing products.

Feasibility for Ultrasound Pad Material for the Evaluation Axillary Region of Automated Breast Ultrasound Equipment (자동유방초음파 장비의 액와부 평가를 위한 초음파 패드 물질의 타당성)

  • Seo, Eun-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.231-240
    • /
    • 2018
  • Automated breast ultrasound (ABUS) equipment is a new innovative technique for 3D automatic breast scanning, but limited for the examination in the concave axillary region. The purpose of this study was to determine feasible candidate materials for the ultrasonic wave propagation media in ABUS, enabling the evaluation of the axillary region. Ultrasonography was performed using an ABUS system ($Invenia^{TM}ABUS$, GE, USA) on the ultrasound-specific phantom (UC-551M-0.5, ATS Laboratories, USA) covered by different candidate materials. The validity of feasible candidate materials was evaluated by image quality. Three independent radiological technologists, with more than 10 years of experience, visually assessed on the images. The inter-observer agreements according to the candidate materials were tested using Cronbach's alpha. Unenveloped solidified carrageenan can be a feasible material for the use of ABUS with excellent test reliability. Therefore, the coverage of the axillary region with carrageenan may be effective for ABUS which was originally developed for the convex anatomic structure as female breast.

Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography (디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구)

  • Kim, Myeong-soo;Kim, Young-kuen;Jang, Young-Il
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.

3D Pattern Development of Functional Women's Swimwear To Improve the Appearance and Stability of Chest Region (3차원 테크놀러지를 이용한 여성용 수영복의 가슴부위 외관 및 패턴 기능성 향상에 관한 연구)

  • Yoo, Joung-Ja;Hong, Kyung-Hi
    • Korean Journal of Human Ecology
    • /
    • v.21 no.2
    • /
    • pp.285-298
    • /
    • 2012
  • Considerable number of women are enjoying swimming, however, the chest-region of swimsuits including cup inserts are not stable during swimming. The purpose of this study was to explore alternate designs and methods of stabilizing the breast cup to the swimmer's body by using 3D technology to design and position the pad and cup pattern of the swimming suit. To position the pad optimally, a 3D pattern of a nude woman was divided into blocks and different reduction rates were applied to blocks around the outlines of the breast. Two types of 3D patterns were developed. The first, referred to as the 'basic 3D pattern' provided for the curved surface of the breast point to be maintained with the remaining slack distributed evenly along the neckline, armhole and side seam. The second, referred to as the '1/3 shoulder moved 3D pattern' ignored the curved nature of the breast point by overlapping, with the resulting position of the shoulder strip moved toward the center. Three women of corresponding size and body shape evaluated the two 3D pattern designs as well as the conventional 2D pattern style of swimsuit. Respondents rated the'the basic 3D pattern' design highest in terms of stability and easy of movement in the chest region.