• Title/Summary/Keyword: 유량-유사량

Search Result 346, Processing Time 0.028 seconds

Primary Productivity of Phytoplankton at the Eutrophic down Reach of a Regulated River (the Han River, Korea) (부영양한 한강하류수역에서 식물플랑크톤의 1차생산)

  • Nam, Kung-Hyun;Hwang, Gil-Son;Kim, Kap-Soo;Kim, Bom-Chul
    • Korean Journal of Ecology and Environment
    • /
    • v.34 no.4 s.96
    • /
    • pp.267-276
    • /
    • 2001
  • The downstream reach of the Han River adjoining Seoul in Korea was the upper boundary of an estuary where tidal effect on the flow rate could be exerted. According to the comprehensive river regulation project, the river was channelize dand impounded by two overflow dams, which provided favorable condition for algal growth in this sewage polluted eutrophic reach. In this study primary productivity of phytoplankton was measured in the down reach and the autochthonous and allochthonous organic carbon loadings were estimated. Primary production of phytoplankton measured by C-14 uptake and P-I model method ranged from 140 to $4,890\;mgC\;m^{-2}\;d^{-1}$ (median value $1,865\;mgC\;m^{-2}\;d^{-1}$) showing the level of eutrophic lakes. Phytoplankton density that varied according to water flow rate was highest in spring. Allochthonous organic carbon loading was dominated by sewage input through tributaries in most of days except flood flow period. The average proportion of autochthonous carbon generation by phytoplankton was 40.9%, which is very high proportion for a lotic habitat.

  • PDF

Environmental Studies in the Lower Part of the Han River VIII. Physicochemical Factors Contributing to Variation of Phytoplankton Communities (한강 하류의 환경학적 연구 VIII. 식물플랑크톤 군집의 변화에 미치는 물리 화학적 요인)

  • Kwon, Oh-Youn;Jung, Seung-Won;Lee, Jin-Hwan
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.3 s.117
    • /
    • pp.340-351
    • /
    • 2006
  • To reveal physicochemical factors contributing to variation of phytoplankton communities, the study was carried out biweekly at 6 stations from Feb. 2004 to Feb. 2005 in the lower part of the Han River, Korea. As results, water temperature was changed from $0.3^{\circ}C$ to $26.6^{\circ}C$, pH: 6.6${\sim}$9.1, DO: 1.89${\sim}$22.23 mg $L^{-1}$, BOD: 0.38${\sim}$9.20 mg $L^{-1}$, COD: 1.4${\sim}$15.2 mg $L^{-1}$, Conductivity: $62.5{\sim}500.0\;{\mu}s\;cm^{-1}$, SS: 3.00${\sim}$159.3 mg $L^{-1}$, and Chl a $1.7{\sim}71.3\;{\mu}g\;L^{-1}$. Phytoplankton standing crops ranged from min. $3.6{\times}10^2\;cells\;mL^{-1}$ (July 2004, St. 3) to max. $2.3{\times}10^4\;cells\;mL^{-1}$ (Feb. 2005, St. 6), and mean of those varied from $5.9{\times}10^3\;cells\;mL^{-1}$in spring, $2.1{\times}10^3\;cells\;mL^{-1}$ in summer, $4.1{\times}10^3\;cells\;mL^{-1}$ in autumn and $8.5{\times}10^3\;cells\;mL^{-1}$ in winter, respectively. In order to investigate factors influencing the total phytoplankton standing crops a multiple regression analysis was adopted for the correlation between standing crops and environmental factors. The coefficient of determination ($R^2$) value of the regression was 0.465, it showed that environmental factors which predominantly influenced phytoplankton standing crops were water temperature, COD, $NO_2-N$, $PO_4-N$, Discharge and pH. six stations could be divided into 3 groups based on similarity index in terms of environmental factors. In ANOVA analysis for physicochemical and biological factors, water temperature, chlorophyll a, silicate, phytoplankton standing crops were the same group differed little from stations. However, Station 1and 2 were grouped followed in dissolved oxygen, conductivity, COD, nitrite, nitrate, ammonia and phosphate, and Station 3, 4 and 5 were followed in dissolved oxygen, conductivity, pH and phosphate.

Distribution Characteristics of Polycyclic Aromatic Hydrocarbons(PAHs) in Riverine Waters of Ulsan Coast, Korea (울산연안 하천에서 다환방향족탄화수소 분포특성)

  • You, Young-Seok;Lee, Jeong-Hoon;Park, Jeong-Chae;Kim, Dong-Myung;Cho, Hyeon-Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.398-405
    • /
    • 2012
  • PAHs(Polycyclic Aromatic Hydrocarbons) in coastal area and estuary adjacent to urban area and industrial activities region are mainly introduced into marine environment via atmosphere and river. This study which is evaluated the distribution characteristics of PAHs discharge from rivers and sewage disposal water which flowing into Ulsan bay, and were carried out in Jun of dry season and in Auguest of wet season, 2008. The water samples from eight main rivers and Youngyeon WWTP(Wastewater Treatment Plant) flowed into Ulsan bay were taken for analysis of dissolved PAHs. The range and mean values of dissolved PAHs concentrations showed 10.30 to 87.88 ng/L, its mean 36.94 ng/L in dry season and 10.30 to 69.57 ng/L, its mean 24.37 ng/L in wet season. The distribution of dissolved PAHs showd the high concentrations in the Gungcheoncheon which is flowed from urban and industrial area. The ranges and means values of the loading fluxes were estimated with 0.04 to 8.27 g/day, its mean 2.05 g/day in dry season, and 0.03 to 4.77 g/day, its mean 1.61 g/day, in wet season. The loading flux showed the highest value in Taewha river due to the high flow rate and the urban activity. The composition patterns of dissolved PAHs compound showed most of the trend occupying low molecuar weight PAHs than high molecular weight PAHs. These results were due to physical and chemical characteristics of PAHs compound, and were similar to those of other studies. The concentrations of dissolved PAHs in this study are lower than those of other studies, and the level of PAHs pollution appeared to be not serious in reverine waters of Ulsan coast.

A Study on the Effect of Improving Permeability by Injecting a Soil Remediation Agent in the In-situ Remediation Method Using Plasma Blasting, Pneumatic Fracturing, and Vacuum Suction Method (플라즈마 블라스팅, 공압파쇄, 진공추출이 활용된 지중 토양정화공법의 정화제 주입에 따른 투수성 개선 연구)

  • Geun-Chun Lee;Jae-Yong Song;Cha-Won Kang;Hyun-Shic Jang;Bo-An Jang;Yu-Chul Park
    • The Journal of Engineering Geology
    • /
    • v.33 no.3
    • /
    • pp.371-388
    • /
    • 2023
  • A stratum with a complex composition and a distributed low-permeability soil layer is difficult to remediate quickly because the soil remediation does not proceed easily. For efficient purification, the permeability should be improved and the soil remediation agent (H2O2) should be injected into the contaminated section to make sufficient contact with the TPH (Total petroleum hydrocarbons). This study analyzed a method for crack formation and effective delivery of the soil remediation agent based on pneumatic fracturing, plasma blasting, and vacuum suction (the PPV method) and compared its improvement effect relative to chemical oxidation. A demonstration test confirmed the effective delivery of the soil remediation agent to a site contaminated with TPH. The injection amount and injection time were monitored to calculate the delivery characteristics and the range of influence, and electrical resistivity surveying qualitatively confirmed changes in the underground environment. Permeability tests also evaluated and compared the permeability changes for each method. The amount of soil remediation agent injected was increased by about 4.74 to 7.48 times in the experimental group (PPV method) compared with the control group (chemical oxidation); the PPV method allowed injection rates per unit time (L/min) about 5.00 to 7.54 times quicker than the control method. Electrical resistivity measurements assessed that in the PPV method, the diffusion of H2O22 and other fluids to the surface soil layer reduced the low resistivity change ratio: the horizontal change ratio between the injection well and the extraction well decreased the resistivity by about 1.12 to 2.38 times. Quantitative evaluation of hydraulic conductivity at the end of the test found that the control group had 21.1% of the original hydraulic conductivity and the experimental group retained 81.3% of the initial value, close to the initial permeability coefficient. Calculated radii of influence based on the survey results showed that the results of the PPV method were improved by 220% on average compared with those of the control group.

Performance Evaluation and Economic Analysis on the Integrated Small Hydro Power Generation Device Using a Discharged Water of Sewage Treatment Plant (하수처리장의 방류수를 이용한 일체형 발전장치의 성능평가 및 경제성 분석)

  • Park, Yoo-Sin;Kim, Ki-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.9
    • /
    • pp.486-491
    • /
    • 2017
  • The water discharged from sewage treatment plants has been considered to be useless, due to itslack of economic utility for small hydro power generation. Considering that most sewage treatment facilities have a water head of less than 2 meters and their flow rate is constant, it is necessary to develop a small hydro power generation device capable of maintaining stable power generation and efficiency. This paper presents the development of anintegrated small hydro power generation system and presents its performance evaluation and results. Then, the economics and use of the system for practical applications are suggested. As a result, it is foundthat the generator efficiency is 92%, the electric energy produced is 10kWh and the economic efficiency, as described by the B/C ratio,is 1.0 or more. Particularly, if the operating level of the generation device is maintained at 80% or more of the rated power, it is possible to secure its economic efficiency and, after 23 years, the investment cost will bereturned. The integrated hydro power generation device is expected to have a positive effect not only in terms of the water discharged from the sewage treatment plant, but also in terms of facilities capable of securing similar flow characteristics.

Analysis of Specific Contaminated Status and Pollutant Loads Contribution Rate of the Tributaries in Gumho and Nam River Basin (금호강, 남강 중권역 지류·지천의 상세오염 현황 및 오염기여율 조사)

  • Na, Seungmin;Kwon, Heongak;Kim, Gyeong Hoon;Shin, Dongseok;Im, Tae Hyo
    • Journal of Wetlands Research
    • /
    • v.18 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • This study was investigated the pollutant load, contamination properties, pollution condition of the fine parts of tributary, the influence of Nakdong river watershed and etc. in the tributaries. The contaminated tributaries were that among the Kumho and Nam river or were too far from site of water quality monitoring stations, regularly. As a result, the water quality level was almost similar between Nam and Kumho River, except for certain parameter including TN(Total Nitrogen), Chl-a(Chlorophyll-a) and SS(Suspended Solid) in which Kumho river were 20~120%. The point discharge load(kg/day) and load density ($kg/day/km^2$) of tributaries were different the pollution level according to the flow-rate ($m^3/sec$) and stream influence area($km^2$), and the difference of these was observed highly at Nam river. Specific contamination investigation of tributaries in Nam and Kumho river watershed was conducted from two to nine points of the fine parts of tributaries depending on the confluence sites and shapes. This result observed high at the Dalseocheon and Uriyeongcheon, respectively. Beside, the pollutant load contribution rate of Nakdong watershed was high about 10% at the Dalseocheon and Uiryeongcheon. This was due to the differences of the environments about the industrial complex, metropolis residence property, agricultural cultivation, livestock pen and the downstream of non-point source.

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Culture of Nile Tilapia (Oreochromis niloticus) in Recirculating Aquaculture System (순환여과식 양식 시스템에서 나일 틸라피아(Oreochromis niloticus)의 사육)

  • Seo Kuen Hack;Kim Byong Jin;Jo Jae Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.1
    • /
    • pp.27-34
    • /
    • 2002
  • The performances of fish culture were evaluated in the integrated recirculating aquaculture system consisting of a double drain type rearing tank ($2.5 m^3$), a sedimentation tank, a floating bead filter, a foam separator and a rotating biological contactor. A system was stocked with nile tilapia at an initial rearing densities of $5\%$ (A), $5\%$ (B) and $7\%$ (C) oyer 30 days. Feed coefficient was 1.62, 1,79 and 1.80 and average daily growth rate was $0.452\%$, 0.u5% and $0.423\%$, respectively. The level of TAN was maintained below $1 g/m^3$ for $5\%$ of initial rearing density and $2-4 g/m^3$ for $7\%$. The dissolved oxygen level ($2-4 g/m^3$) was not optimum but should not be inhibitory to fish growth. The total suspended solid was completely removed during overall experimental period.

A Consideration of the Decision-Making Efficiency Concerning the Removal of Oil Spills by Foreign Ships in the EEZ (EEZ내 외국 침몰선박 잔존유 제거 의사결정 효율화 방안 고찰)

  • Na, Song-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.698-707
    • /
    • 2019
  • The removal of oil spilled by the sinking of a foreign ship in Korea's Exclusive Economic Zone (EEZ) began in May 2019 four years after the ship sunk near Jeju Island. The cleanup was conducted by a foreign company that was contracted to the ship-owner's protection & indemnity (P&I) insurance company. In contrast to the time taken to begin the cleanup, the operation itself was completed in just 22days. Compared to similar cases, the decision to begin the removal was a delayed one. This study analyzes all 93 documents related to the ship's sinking and the eventual cleanup, confirming delays in administrative decision-making on the removal, and identifies factors that influenced this delay. These factors include a neglect of accident-related data verification, and other, legal, technical, environmental, and human aspects. Finally, this study suggests ways to improve decision-making efficiency. As the first study dealing with the cleanup in the EEZ, this research is expected to facilitate decision-making and influence the formulation of policies in the future.

Driving Properties of Diesel Injection System using the Multilayer Actuator Structured-ultrasonic Nozzle (적층액츄에이터형 초음파 노즐을 이용한 경유분사 시스템의 구동특성)

  • Kim, Do-Hyung;Kim, Hwa-Soo;Kang, Jin-Hee;Lee, Yu-Hyong;Hwang, Lark-Hoon;Yoo, Ju-Hyun;Hong, Jae-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.174-174
    • /
    • 2008
  • 초음파를 이용하여 액체 연료를 분사하면 균일한 입경과 미립화가 우수하며 에너지 절약과 공해방지등을 할 수 있다. 또한 유속과 유량에 관계없이 이용할 수 있어 반도체 분야의 웨이퍼와 평판 표시기상에 사진 석판용 화학물질의 균일도포 컴퓨터 하드 디스크의 광택제 도포등에 사용할 수 있다. 이처럼 초저의 유출 용량을 요구하는 모든 공정 및 액체연료의 분사가 요구되는 모든 산업에 적용할 수 있는 장점을 가지고 있다. 하지만 현제까지 주로 사용되고 있는 초음파노즐의 액츄에이터는 단판액츄에이터형로 높은 교류전압을 인가해주어야 하는 단점을 가지고 있다. 이 단점을 해결하기 위해 적층액츄에이터형을 사용하여 초음파 노즐 구동하면 낮은 교류 입력전압에서도 단판액츄에이터형 초음파 노즐과 같은 특성을 가질 수 있다. 또한 초음파 노즐의 구동시 기계적인 진동을 이용하므로 많은 열을 발생시켜 노즐의 온도가 상승하여 세라믹 액츄에이터에도 그 영향을 미치게 되어 열적 열화 현상이 일어날 수 있기에 높은 큐리온도를 가지는 액츄에이터가 필요하다. 본 실험에서는 $Pb(Mn_{1/3}Nb_{2/3})_{0.02}(Ni_{1/3}Nb_{2/3})_{0.12}(Zr_{0.50}Ti_{0.50})_{0.86}O_3$ 조성을 사용하여 $900^{\circ}C$의 저온에서 액상 소결하여 적층혈액츄에이터를 제작하였으며 압전 및 유전 특성을 조사하였다. 제작된 초음파노즐을 구동하기 위해서는 약 36kHz의 30V이상의 교류입력전압 할 수 있는 구동회로가 필요로 한다. 압전액츄에이터의 구동을 위해서는 정확한 정현파 입력이 필요 없다. 압전액츄에이터의 특성상 유사 정현파 입력 만으로도 임피던스 매칭이 이루어지기 때문에 설계가 쉽고 간편한 Push-Pull 방식을 이용한 PWM인버터를 사용하였고 인버터의 출력 주파수를 34~38kHz까지 가변 할 수 있게 설계하였다. 제작된 적층액츄에이터형 초음파 노즐을 PWM인버터로 실제 액체 연료인 경유를 분사하였을 때의 액츄에이터의 온도 변화에 따른 공진주파수와 온도 의존성, 전기적 특성을 조사하고 미립화 분사되는 경유의 미립자 크기 및 최대 분사량을 조사 하였다.

  • PDF