• Title/Summary/Keyword: 유량 측정

Search Result 1,990, Processing Time 0.034 seconds

The Development of High Pressure Long Distance Fire-fighting Hose with Phosphorescent Performance (축광 성능을 갖는 고압용 장거리 호스 개발에 관한 연구)

  • Han, Yong-Taek;Na, Byung-Gyun;Choi, Jin-Seong;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.63-69
    • /
    • 2017
  • This study describes the development of a long-distance hose for ultra-high pressure operation, which can be used in conjunction with an ultra-high pressure pump and can be effectively applied to the fire suppression of high-rise buildings and a long, large tunnels. Also, it has phosphorescent properties, which can help to secure the withdrawal route of the fire-fighters when they are threatened by the fire. We developed an ultra-high pressure hose aiming at a pressure of 3 MPa and a flow rate of 2000 lpm and developed an ultra-high pressure fire hose that can withstand this very high pressure by using a double jacket, triple polyurethane coating and warf (Wp) of 52. In order to ensure the performance of the developed ultra-high pressure hose, its structure, appearance, leakage at high pressure, length and elongation were inspected by a certified certification agency, who also subjected it to a peeling test, friction test, breaking pressure test and free fall test. Also, it was studied in addition to the luminescent high-pressure hose for fire-fighting. In the phosphorescence test, the luminance measurement value was more than the reference value of the luminance test after 40 minutes, which confirmed that its performance was satisfactory for fire-fighting products. In the future, if such an ultra-high pressure fire hose were commercialized and applied in the field, it could contribute to securing improved fire suppression and safer exit from fires, as compared to the fire hoses currently used in the suppression of fires in skyscraper buildings and long tunnels.

An Experimental Study on the Fundamental Characteristics of LPG Gas Injections System (LPG 가스분사시스템의 기초특성에 대한 실험적 연구)

  • Jang, Yeol-Sung;Woo, Sung-Dong;Kim, Hyeong-Sig;Park, Chan-Jun;Ohm, In-Yong
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.277-283
    • /
    • 2006
  • In this study, butane 100% was used as fuel to verify the real fuel effect such as vapor pressure variation due to temperature change. A MPI fuel injection system for V-6 engine, which has reverse 'L' type cross section to minimize the possibility of liquid phase injection, was composed and one bank was operated under sequential injection scheme. Flow rate were measured according to injection duration, interval, and pressure. Also occurring of liquid phase injection was monitored with varying vaporizer and fuel rail temperature. The result shows that basic characteristics of injection is a relatively difference between air and LPG injection. Under cold start condition, however, the occurrence of liquid injection becomes more severe as the pressure increases, and sufficiently high temperature both in vaporizer and fuel rail is very important to insure gaseous injection. In addition, the temperature of vaporizer plays more important role in keeping LPG vapor state and the reverse 'L' type cross section of the rail is available to prevent liquid injection.

A Study on Velocity Distribution Characteristics for Each Location and Effectiveness of Straight Duct Length in a Square-sectional 180° Bended Duct (정사각형 단면을 갖는 180° 곡관에서 위치별 속도분포특성 및 직관거리의 유효성에 관한 연구)

  • Chen, Jing-Jing;Yoon, Jun-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.10
    • /
    • pp.618-627
    • /
    • 2016
  • This study numerically analyzes the characteristics of the velocity distribution for each location of a square-sectional $180^{\circ}$ bent duct using a Reynolds Stress Turbulent model. The flow parameters were varied, including the working fluids, inlet velocity, surface roughness, radius of curvature, and hydraulic diameter. The boundary conditions for computational fluid dynamics analysis were inlet temperatures of air and water of 288 K and 293 K, inlet air velocity of 3-15 m/s, inner surface roughness of 0-0.001 mm, radius of curvature of 2.5-4.5 D, and hydraulic diameter of 70-100 mm. The working fluid characteristics were highly affected by changes in the viscous force. The maximum velocity profiles in the bent duct were indicated when the $90^{\circ}$ section was in the region of X/D=0.8 and the $180^{\circ}$ section was in the region of Y/D=0.8. Lower surface roughness and higher radius of curvature resulted in a higher rate of velocity change. Also, an efficient measuring location downstream of the bent duct is suggested since the flow deviations were the most stable when the straight duct length was in the region of L/D=30. The minimum deviations at the same velocity conditions according to the hydraulic diameter were mostly indicated in the range of L/D=15-30 based on the standard deviation characteristics.

FMD response cow hooves and temperature detection algorithm using a thermal imaging camera (열화상 카메라를 이용한 구제역 대응 소 발굽 온도 검출 알고리즘 개발)

  • Yu, Chan-Ju;Kim, Jeong-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.292-301
    • /
    • 2016
  • Because damages arising from the occurrence of foot-and-mouth disease (FMD) are very great, it is essential to make a preemptive diagnosis to cope with it in order to minimize those damages. The main symptoms of foot-and-mouth disease are body temperature increase, loss of appetite, formation of blisters in the mouth, on hooves and breasts, etc. in a cow or a bull, among which the body temperature check is the easiest and quickest way to detect the disease. In this paper, an algorithm to detect FMD from the hooves of cattle was developed and implemented for preemptive coping with foot-and-mouth disease, and a hoof check test is conducted after the installation of a high-resolution camera module, a thermo-graphic camera, and a temperature/humidity module in the cattle shed. Through the algorithm and system developed in this study, it is possible to cope with an early-stage situation in which cattle are suspected as suffering from foot-and-mouth disease, creating an optimized growth environment for cattle. In particular, in this study, the system to cope with FMD does not use a portable thermo-graphic camera, but a fixed camera attached to the cattle shed. It does not need additional personnel, has a function to measure the temperature of cattle hooves automatically through an image algorithm, and includes an automated alarm for a smart phone. This system enables the prediction of a possible occurrence of foot-and-mouth disease on a real-time basis, and also enables initial-stage disinfection to be performed to cope with the disease without needing extra personnel.

Experiment and Assessment of Ascending Capability for Management of Exotic Fish Species (외래어종 관리를 위한 소상 실험 및 평가)

  • Kang, Joon-Gu;Kim, Jong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.265-278
    • /
    • 2016
  • In this study, an ascending capability experiment was performed with largemouth bass and bluegill, which are exotic fish species inhabiting (the freshwaters) in Korea. The experiment was performed by dividing the subject fish into four groups according to their size and at four flow rates for each group. The number of fish passing through a reference line was analyzed by recording videos, and their swimming and ascending capabilities were observed by the naked eye. The number of fish passing through the reference line did not include those returning downstream within five minutes due to the high flow rate. The flow rate used for the analysis was the mean of the flow rate values measured at the left bank, the right bank, and in the middle of the stream. The results showed that the number of exotic fish migrating upstream decreased as the flow rate increased, regardless of the species and size of the fish. The comparison between the fish species showed that the ascending capability of bass was higher than that of bluegill, but the difference was not significant when considering the difference in the size of the fish. In addition, the upper limit flow velocity allowing the ascending of the exotic fish species was 1.11 m/s, when considering the fish returning to the downstream after the upstream migration and experimental error. The results of the experiment may be used as fundamental data for the blocking of fish and the management of exotic fish species by means of a high flow rate current. Further experiments, verification, and monitoring may need to be conducted continuously to determine whether the fish are able to pass through the reference line at a high flow rate, when they attain a high or cruising velocity. Additionally, the reaction of the fish species should be investigated by considering the response to external forces as well as pressure differences due to the flow rate.

Analysis of Density Current in the Tidal River (감조하천(感潮河川)의 하구(河口) 밀도류해석(密度流解析))

  • Suh, Seung Duk;Park, Sung Bae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.70-76
    • /
    • 1986
  • The purpose of this study is to offer the basic data of the tidal river development program by grasping the diffusion between the high density-sea water and the low density-fresh water in the tidal river. The tidal range of Hyungsan river which flows at Youngil bay in Pohang was selected to analysis the phenomenon of density current. The results obtained are as follows ; The tide of Youngil bay was one time a day, 0.104m in high tide difference and 0.085m in mean tidy difference. The change of sea level by tide was negligible. The volume of reserved water by sea water was $2,700,000m^3$ and available water of irrigation was $1,200,000m^3$ that salt density is below $750{\mu}{\mho}/cm$ out of total volume. Salt intrusion phenomenon by density current was a little water level change, however, it become a salt wedge type by the much salt invasion during the spring tide and it makes a well-mixed type by the retreating salt wedge during the neap tide. As long as there were some density differences between sea water and fresh water, net upstream flow was existed along the bottom of water way from the estuary to the upstream channel.

  • PDF

Study of Factors for development of Advanced Media filter for Ballast water Treatment (밸러스트 수 처리용 메디아 필터 개발을 위한 여과특성에 관한 연구)

  • Park, Seon-Jeong;Lim, Jae-Dong;Kim, Dong-Geun;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2008
  • As the conference result of MEPC in IMO, development of ballast water management system corresponding to newly established ballast water management standard (D2 regulation) of shipping is being made an active progress over the whole world. The ballast water management system should treat particular material of more than $10{\mu}m$ in high capacity of more than 500t per hour in the event of filtration process. Also, it is very difficult to develop a practical management system since a limited element which a narrow space of the ship should be designed in the minimal volume is assumed. Therefore, the study promoted a study on the next generation auto back wash media filter to overcome such a limited element. Also, the study performed pressure and flux measurement test followed by thickness of each filter medium for filtration by each size to grasp a relation between absorption and pressure at the time of vacuum filtration and mechanical analysis and turbidity change observation of filtered water after vacuum filtration.

Application of K-BASINRR developed for Continuous Rainfall Runoff Analysis to Yongdam Dam Test Bed (장기유출해석을 위하여 개발된 K-BASINRR의 용담댐 시험유역 적용)

  • Kim, Yeonsu;Jung, Ji Young;Noh, Joonwoo;Kim, Sung Hoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.211-211
    • /
    • 2017
  • 장기유출해석 모델은 수자원의 안정적인 확보와 이용, 유역단위 기초자료 조사관리 등을 위하여 수자원 장기종합계획 및 전국유역조사사업 등에 활용되고 있다. 주로 국외에서 개발된 모형이 활용되고 있어, 국내의 여건에 맞추어 편의성이 개선된 모형을 찾는 것은 매우 어려운 일이다. 또한, 유출해석을 수행하기에 앞서 지속적으로 업데이트된 모델에 대한 객관적인 평가를 수행한 사례는 드물다. 따라서, 본 연구에서는 국내에서 주로 활용되고 있는 장기유출해석모델(TANK, SWAT, SSARR, PRMS 등)에 대한 비교검토를 토대로 각종 사업과의 연계성, 계산의 효율성, 정확도 등을 고려하여 USGS에서 개발한 PRMS v.4.0.2를 기반으로 국내유역에 활용이 가능하도록 개선한 $K-BASIN^{RR}$ 및 입력자료 전처리기를 개발하였다. PRMS 모형은 융설 및 지하수 흐름 등 다양한 기능을 포함하여 강우유출 분석에 활용성 높은 모형으로 평가받고 있으나, 국내 OS환경 및 활용 단위계에서 활용성이 떨어지는 단점이 있다. 본 연구에서는 소스코드 개선 및 GUI구축을 통하여 PC 환경에서 구동이 쉽도록 재구성하였고, 사용자 편의성 확보를 위한 입력자료 전처리기를 개발함으로써 수자원단위지도 3.0, 임상도 재분류 테이블, 토양도 재분류 테이블의 DB화 및 모형의 구동을 위한 HRU분할, 입력자료 생성이 가능하도록 하였다. 매개변수 최적화를 위하여 하천 유량뿐만 아니라 기저유출량을 대상으로 Monte-Carlo 시뮬레이션 기반의 매개변수를 최적화 기능을 탑재하였다. 개발된 모형의 적용성 평가를 위하여 용담댐 시험유역을 대상으로 11년 간(2005-2015)의 강우 및 온도자료를 입력자료로 활용하여 모의한 결과 샘플의 개수에 따라 NSE(Nash-Sutcliffe Efficiency)를 0.9까지 추정이 가능함을 파악하였다. 또한, 유출량과 기저유출에 대하여 동시에 최적화를 수행하는 경우 NSE를 유출량에 대하여 0.8, 기저유출량에 대하여 0.6까지 추정이 가능하였다. 최적화된 모의 결과에 대한 검토를 위하여 계산증발산량을 측정증발산량과 비교한 결과, 유사한 패턴을 나타내는 것을 확인할 수 있었다. 본 연구에서 개발한 $K-BASIN^{RR}$을 활용하는 경우 장기유출해석 업무에 효율성 및 정확도를 향상할 수 있을 것으로 판단된다.

  • PDF

Evaluation of the applicability of Cockle shell and walnut shell in a bioretention facility (Bioretention 내 꼬막 및 호두껍질의 적용성 평가)

  • Jeon, Minsu;Geronimo, F.K.F.;Choi, Hyeseon;Kim, Lee-hyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.203-203
    • /
    • 2019
  • 도시화로 인한 불투수면의 증가는 물순환 왜곡, 비점오염원 발생 및 수생태계 건상성 훼손 등을 야기시키며, 이를 해결하기 위하여 다양한 LID 기법을 적용하고 있다. 일반적으로 LID 내 적용 되는 여재들은 무기성여재로 중량이 크고 미세공극의 부재로 물리화학적 및 생물학적 저감기능이 제한적이다. 따라서 본 연구에서는 중량성이 낮은 생물폐자원을 선정하여 LID 시설 적용성평가를 수행하고자 한다. 생물폐자원은 발생량, 경량성 및 용이성을 고려하여 꼬막껍질(CS)과 호두껍질(WS)을 선정하였다. 생물폐자원의 산화부식을 고려하여 무기성 여재인 화산석과 혼합하여 Bioretention 시설에 적용하였으며, 여재 혼합비율에 따라 총 3가지의 Case 로 구성하였다. 식생은 구절초와 꽃댕강나무를 식재하였으며, 여재의 물리적 특성 분석을 위하여 적용 전과 후의 SEM(Scanning Electronic Microscope)을 수행하였다. 모니터링은 도로퇴적물 100g과 물 110L를 제조하여 인공강우유출수를 이용하여 수행하였으며, $0.0003{\sim}0.007m^3/sec$의 유속으로 주입하였다. 시설의 유입 및 유출부에서 유량 측정 및 수질 시료를 채취하였으며, 채취된 시료는 수질오염공정 시험법에 준하여 입자상 물질, 유기물, 영양물질 및 중금속 등을 분석하였다. Bioretention 시설의 모니터링 결과를 이용하여 물수지 및 TSS 저감 효율을 산정하였으며. 물수지 분석결과 시설의 저류율은 Case 1(soil) > Case 3(WS+RV) > Case 2(CS+RV) 순으로 나타났다. 시설 내 공극률이 가장 낮았던 Case 1에서 저류율이 약 55%로 가장 높게 것으로 분석되었다. Case 3(WS+RV)은 Case 2(WS+RV)와 시설 내 공극률이 유사함에도 불구하고 저류율이 약 10% 높은 것으로 분석되었다. 오염물질 저감효율 분석 결과, TSS와 TP의 제거효율은 모든 Case에서 약 75% 이상으로 높게 나타났으며, COD의 경우 모래를 적용한 Case 1에 비해 생물폐자원인 꼬막껍질과 호두껍질을 적용한 Case에서 약 1.3배 이상 높게 나타났다. 호두껍질과 꼬막껍질의 SEM 분석 결과 표면에 다공성이 형성되어 있는 것으로 조사되었다. 이는 여과 및 저류기작으로 인한 물순환 효과증대와 다공성과 돌기사이로 인한 입자상의 물질 여과 및 흡착으로 인하여 오염물질의 제거효율이 증대 된 것으로 평가된다. LID시설 내 생물폐자원과 무기성여재를 적절히 배합하여 복합여재로 조성할 경우 침하현상을 방지할 뿐만 아니라 저류 및 침투기능 향상과 미생물의 서식환경을 제공하기에 물순환 회복 및 비점오염물질 저감에 기여할 것으로 평가된다.

  • PDF

Full Scale Testing of the Effect of Stairwell Pressurization on Pressure Differential and Flow Velocity

  • Son, Bong-Sae;Park, Kyung-Hwan;Chang, Young-Bae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.83-89
    • /
    • 2011
  • A series of full-scale testing was conducted to examine the effect of stairwell pressurization on the pressure differential between the stairwell and the auxiliary room and between the auxiliary room and the residence. Also, flow velocity profiles at open doors were measured. The building tested was a condominium that had twenty floors above the ground and two floors underground. For pressurization of the stairs, a blower was used to supply air into the stairwell at one location underground. Thirteen different cases were tested, and test variables included the number of floors with open doors and the flow rate of the air supply. When the doors on the first floor were open, the pressure differential between the stairwell and the auxiliary room was distributed almost uniformly except for locations near the first floor. When the flow rate was in the range of 180~270 CMM and the doors of one floor were open, the flow velocity could satisfy the requirement of fire safety standards and the stairwell pressure was positive at all levels. However, the minimum pressure requirement (10 Pa) could not always be satisfied. When doors on two floors were open, the flow velocity requirement could be satisfied by increasing the flow rate, but it was found impractical to satisfy the minimum pressure requirement without causing excessive pressure differential in the area near the blower.