• Title/Summary/Keyword: 유량 제어 밸브

Search Result 210, Processing Time 0.027 seconds

A Study on the Force Balance of a Main Oxidizer shutoff Valve (산화제 개폐밸브의 힘평형에 관한 연구)

  • Jeon, Jae-Hyoung;Hong, Moon-Geun;Kim, Hyun-Jun;Lee, Soo-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.8
    • /
    • pp.812-818
    • /
    • 2009
  • A MOV(Main Oxidizer shutoff Valve) controls the flow rate of liquid oxygen into the rocket combustor by opening and shutting operations piloted by a pneumatic force. In order to improve the effective design for sealing parts of poppet and piston assemblies, the poppet assembly has been designed to be just contacted with the piston assembly. However, to avoid a gap at the poppet/piston contact surface and to evaluate the MOV operating performance, an analyze on the force balance during the closing motion have been performed. For the accuracy of the analysis, the friction forces and the hydraulic forces have been respectively obtained by experiments and CFD analysis. Through the analysis, some important design parameters such as the spring constant, poppet friction and orifice size in the force balance have been introduced and the required operation performance of the MOV has been proved feasible.

기체의 유량 및 온도 변화에 따른 진공 펌프의 성능 특성 연구

  • Heo, Jung-Sik;Im, Jong-Yeon;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.16-16
    • /
    • 2010
  • 반도체 및 LCD 공정이 진행되는 진공 챔버는 유량계, 진공 펌프 및 밸브 등을 이용하여 적절한 공정용 기체와 압력을 제어하게 된다. 공정에 따라 매우 높은 온도를 유지해야 하는 경우도 있다. 챔버 내부의 압력은 유입되는 기체의 시간에 따른 유량 변화에 의하여 주기적으로 변화하게 된다. 이러한 유량 변화는 장기적으로는 결국 펌프의 신뢰성(내구수명)에 영향을 주게 되며, 특히 고유량 및 저유량을 반복하게 되는 공정에 있어서는 더욱 큰 영향을 미치게 된다. 또한 챔버 내부는 다양한 화학적 반응이 일어나며 이러한 공정 기체들의 높은 온도는 결국 챔버에 연결된 펌프의 성능 및 신뢰성에도 영향을 주게 된다. 대부분의 반도체 및 LCD 공정이 이루어지는 압력에서는 전도 및 대류의 열전달 형태보다는 열복사에 의한 영향을 받게 되어 챔버를 적절히 설계한다면 펌프에 직접적으로 전달되는 복사량은 상대적으로 낮고, 펌프에 미치는 영향도 크지 않게 된다. 그러나 압력의 변화에 따라 전도 및 대류의 영향이 커지게 되는 경우에는 펌프 자체 및 성능에 큰 영향을 주게 될 것이다. 터보형 펌프의 국내(KS) 및 국제규격(ISO)의 성능시험방법에는 이러한 온도에 따른 펌프의 성능 특성 변화를 다루고 있지 않으며, 크라이오 펌프인 경우 열복사의 영향에 대한 시험방법이 일부 공개되어 있다[J. Vac. Sci. Technol. A 17(5)]. 본 연구에서는 기체의 유량 및 온도 변화에 따른 진공 펌프의 성능 특성 변화를 고찰하고자 하며, 향후 이러한 시험방법에 대한 표준 절차를 확립하고자 한다.

  • PDF

기체의 유량 및 온도 변화에 따른 진공 펌프의 성능 특성 연구

  • Heo, Jung-Sik;Im, Jong-Yeon;In, Sang-Ryeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.328-328
    • /
    • 2010
  • 반도체 및 LCD 공정이 진행되는 진공 챔버는 유량계, 진공 펌프 및 밸브 등을 이용하여 적절한 공정용 기체와 압력을 제어하게 된다. 공정에 따라 매우 높은 온도를 유지해야 하는 경우도 있다. 챔버 내부의 압력은 유입되는 기체의 시간에 따른 유량 변화에 의하여 주기적으로 변화하게 된다. 이러한 유량 변화는 장기적으로는 결국 펌프의 신뢰성(내구수명)에 영향을 주게 되며, 특히 고유량 및 저유량을 반복하게 되는 공정에 있어서는 더욱 큰 영향을 미치게 된다. 또한 챔버 내부는 다양한 화학적 반응이 일어나며 이러한 공정 기체들의 높은 온도는 결국 챔버에 연결된 펌프의 성능 및 신뢰성에도 영향을 주게 된다. 대부분의 반도체 및 LCD 공정이 이루어지는 압력에서는 전도 및 대류의 열전달 형태 보다는 열복사에 의한 영향을 받게 되어 챔버를 적절히 설계한다면 펌프에 직접적으로 전달되는 복사량은 상대적으로 낮고, 펌프에 미치는 영향도 크지 않게 된다. 그러나 압력의 변화에 따라 전도 및 대류의 영향이 커지게 되는 경우에는 펌프 자체 및 성능에 큰 영향을 주게 될 것이다. 터보형 펌프의 국내(KS) 및 국제규격(ISO)의 성능시험방법에는 이러한 온도에 따른 펌프의 성능 특성 변화를 다루고 있지 않으며, 크라이오 펌프인 경우 열복사의 영향에 대한 시험방법이 일부 공개되어 있다[J. Vac. Sci. Technol. A17(5)]. 본 연구에서는 기체의 유량 및 온도 변화에 따른 진공 펌프의 성능 특성 변화를 고찰하고자 하며, 향후 이러한 시험방법에 대한 표준 절차를 확립하고자 한다.

  • PDF

Time Response Characteristics by the exciter types (여자기 형식에 따른 시간 응답 특성 비교)

  • Shin, Man-Su;Lee, Ju-Hyun;Lee, Gi-Seong;Jeong, Tai-Won
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2152-2154
    • /
    • 2003
  • 전력계통 및 발전기의 안정 운용을 위해 발전기 제어계의 정밀 제어와 정확한 계통 해석을 위한 발전기 관련 정밀 파라미터 취득 및 관리가 요구되는 상황에서 발전기 현장시험과 발전기 관련 안정도 해석용 데이터 취득이 필요한 실정임. 현장 시험(발전기 제어계 특성시험)을 통해서 취득한 데이터를 가지고 모델링 및 제어정수를 조정하여 전력계통 안정도 해석용 데이터 베이스를 구축하게 되는데, 여자기 형식에 따라서 계단 입력 신호가 주어졌을 때 시간응답 특성이 약간씩 차이가 나게 됨. 그리고 발전기 제어계 특성시험은 발전기 직접 관련 데이터 및 원동기(터빈) 입력신호(주증기 유량신호, 주증기 제어밸브 개도 등)까지 측정하게 되는데, 본 논문에서는 발전기 여자제어에 관련된 부분만을 살펴 보았음.

  • PDF

Development of a diaphragm type actuator (다이어프램형 방식의 파일럿 액추에이터 개발)

  • Lee, Joongyoup;Jeong, Daeseong;Han, Sangyeop
    • Aerospace Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.160-166
    • /
    • 2014
  • The shutoff valve of a Liquid Rocket Engines (LRE) controls the flow of propellant between turbo-pump and combustion devices of LRE using pilot pressure and spring force. The shutoff valve is closed when the pilot pressure is removed from the diaphragm type actuator. During designing process of life cycle is when should be analyzed according to the characteristics of forces with respect to the opening and closing of diaphragm actuator. A valve has been designed to adjust the control pressure which is required to open a poppet and to determine the working fluid pressure at which a valve starts to close. During flow capacity test under room temperature as a part of life cycle tests, the leakage in diaphragm was occurred due to the leakage of sheet welding sections. The operating cycle of the diaphragm type actuator is about 61 times with 22 MPa of pilot pressure.

과하중 방지기의 전기체 구조시험 적용에 관한 연구

  • Kim, Sung-Chan;Chae, Dong-Chul;Kim, Sung-Jun;Hwang, In-Hee
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.11-17
    • /
    • 2003
  • This paper present a method of meter-out flow control for overload protection valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

A Study on the Design of Liquid Flow Control Valves for the Pants and Ships(II) (플랜트 및 선박의 액체용 우량제어밸브 설계에 관한 연구(II))

  • 최순호;배윤영;김태한;한기남;주경인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.1-9
    • /
    • 1995
  • The processing paper has devoted to the theory of the flow equations, the basic derivative procedure, the meaning of a valve flow coefficient $C_v$, the valve Reynolds R$R_{ev}$ and its application for liquid control valves, which applicable under the condition of a non-critical flow and the case of piping geometry factor $F_p$=1.0. However there is no information on the effects of fittings, a critical flow and the flow resistance coefficient of a valve equivalent to that of pipe which is conveniently used in the piping design. Since the piping systems of plants or ships generally contain various fittings such as expanders and reducers due to different size between pipes and valves and there may occur a critical flow, that a mass flowrate is maintained to be constant, due to the pressure drop in a piping when a liquid is initially maintainder ar a saturated temperature or at nearby corresponding to upstream pressure, system designer should have a knowledge of the effect to flow due to fittings and the critical flow phenomenon of a liquid. This study is performed to inform system designers with the critical flow phenomenon of a liquid, a valve resistance coefficient, a valve geometry factor and their applications.

  • PDF

Static Performance Diagnosis Based on Pressure Signal for a Flow Control Servovalve or Proportional Direction Valve (유량제어용 서보밸브와 비례방향밸브의 압력신호를 이용한 정적 성능 진단에 관한 연구)

  • Kim, S.D.;Jeon, S.H.;Kim, I.D.;Ham, Y.B.
    • Journal of Drive and Control
    • /
    • v.9 no.4
    • /
    • pp.32-41
    • /
    • 2012
  • Most diagnosis methods for servo valves requires installing spool displacement sensor or flow sensor as well as pressure sensor. The measurement of flow is hard to implement and many kinds of servovalves or proportional direction valves do not have a built-in spool displacement sensor. In this study, static performances of servovalve or proportional-direction-valve are studied theoretically and a diagnosis technique, which uses only load pressure and input current signal, is assessed. An experimental setup was made based upon a personal computer and the LabVIEW graphical language. A series of diagnosis tests were performed and the analysis results showed it possible to measure the pressure gain, hysteresis and null bias in a relatively simple methodology.

A Study on the Localization of 1500lb High-Pressure Drop Control Valve for Boiler Feedwater Pump (보일러 급수펌프용 1500lb 고차압 제어밸브 국산화 개발에 관한 연구)

  • Lee, Kwon-Il;Jang, Hoon;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.8
    • /
    • pp.19-24
    • /
    • 2022
  • We developed a prototype from the design of a trim, which is the most important in the localization development of a 1500 Ib high-differential pressure-control valve used for boiler feedwater, and measured the flow coefficient, the most basic design data for valves. The following conclusions were drawn. The comparison of the design values of the flow coefficients for the existing X-trim and the multicore trim designed for localization development showed that they were almost identical, and the X-trim value was slightly lower. The comparison of the X-trim and multicore trim based on the valve flow coefficient test showed that they were generally similar, indicating no problem with the design. In the future, we plan to compare and analyze the flow paths for the X-trim and multicore trim via flow analysis.

A Study on the Chattering under Cryogenic Flow Test of a Oxidizer Shutoff Valve (산화제 개폐밸브의 극저온 유동시험에서 채터링의 고찰)

  • Lee, JoongYoup;Han, SangYeop;Lee, SooYong
    • Aerospace Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.108-117
    • /
    • 2013
  • The oxidizer shutoff valve of a gas generator controls the mass flow rate of the propellant of a rocket engine using pilot pressure and spring the force of the valve. The developing oxidizer shutoff valve can be shut off if the pilot pressure is removed from the actuator. Therefore, force balancing is necessary to analyze the characteristics of the forces with respect to the opening and closing of the valve in order to evaluate its performance. In light of this, the valve has been designed to adjust the control pressure required to open the poppet and to determine the working fluid pressure at which the valve starts to close. Under cryogenic flow test as a tests level of C.R.T(Control Random Test), the chattering phenomena occurred due to much leakage of a metal seat section. The pressure for chattering of the oxidizer valve is predicted at about 11 bar using force balancing analysis.