• Title/Summary/Keyword: 유량컴퓨터

Search Result 103, Processing Time 0.026 seconds

A Study on a PCB Manufacturing Plant's Fire Risk Assessment due to the Mitigation of Fire Protection Zone and an Improvement Way through Estimation of Sprinkler Demand Water Flow Rate (방화구획 완화에 따른 PCB공장의 화재위험평가 및 스프링클러 요구살수유량 산정을 통한 기준개선안에 관한 연구)

  • Oh, Chan-Wook;Oh, Ryun-Seok;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.56-62
    • /
    • 2019
  • A sprinkler is a fire extinguishing equipment installed in a protected area where a detector or head detects a fire and automatically puts out the fire. However, the Ministry of Land, Infrastructure and Transport's "Regulations on Building Evacuation and Fire Protection Standards, etc." stipulate that fire compartment area should be reduced to three times by installing sprinkler facilities in the case of factories and warehouses. In this study, fire hazard was analyzed for a real PCB factory which mitigated the fire protection zone by sprinkler installation, and the head opening characteristics of sprinkler facilities through computer simulation, installation standards of sprinkler facilities, thermal performance, operating range, and the amount of water sprayed to identify the problems of operation of sprinkler facilities in case of fire, and to suggest the grounds such as required sprinkling flow rate for system improvement.

A Study on Scenario-based Urban Flood Prediction using G2D Flood Analysis Model (G2D 침수해석 모형을 이용한 시나리오 기반 도시 침수예측 연구)

  • Hui-Seong Noh;Ki-Hong Park
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.4
    • /
    • pp.488-494
    • /
    • 2023
  • In this paper, scenario-based urban flood prediction for the entire Jinju city was performed, and a simulation domain was constructed using G2D as a 2-dimensional urban flood analysis model. The domain configuration is DEM, and the land cover map is used to set the roughness coefficient for each grid. The input data of the model are water level, water depth and flow rate. In the simulation of the built G2D model, virtual rainfall (3 mm/10 min rainfall given to all grids for 5 hours) and virtual flow were applied. And, a GPU acceleration technique was applied to determine whether to run the flood analysis model in the target area. As a result of the simulation, it was confirmed that the high-resolution flood analysis time was significantly shortened and the flood depth for visual flood judgment could be created for each simulation time.

Solution Algorithm of Unsteady Flow in a Dendritic Channel System (수지형 하천에서의 부정류 흐름의 해석 알고리즘)

  • Choi, Gye Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.839-846
    • /
    • 1994
  • This paper presents a simultaneous solution algorithm for one-dimensional unsteady flow routing through a dendritic channel system. This simulations solution algorithm is based on the double-sweep method and utilizes separate recursion equations for continuity, momentum and energy equations for each of the individual components of a dendritic channel system. Through separate recursion equations for each of the components. the new algorithm converts a dendritic channel network problem into a single-channel problem. The new algorithm is utilized in conjunction with a linearized unsteady flow model using full dynamic flow equations. The required computer storage for the coefficient matrix of the whole system is reduced significantly from the $2N{\times}2N$ matrix to a $2N{\times}4$ matrix, where N is the number of cross sections used in the computation of flow variables in a dendritic channel system. The algorithm presented in this paper provides an efficient and accurate modeling of unsteady flow events through a dendritic channel system.

  • PDF

Manufacture of Control and Data Acquisition System of Centrifugal Thin Film Evaporator(Centri-Therm, CT-1B) by Computer (컴퓨터를 이용한 원심식 박막증발기의 제어 및 자료 수집 시스템의 제작)

  • Park, Noh-Hyun;Kim, Byeong-Sam;Park, Moo-Hyun;Han, Bong-Ho;Bae, Tae-Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.22 no.4
    • /
    • pp.479-485
    • /
    • 1990
  • For the automation of a evaporation process, computer based evaporation system was built and applied to acquisition of the process variables with an centrifugal thin film evaporator(Centri-Therm, CT-1B). Controls of the process conditions were performed by computer system for pressure, feeding rate, steam, evaporation temperature and flow rate of cooling water. The data acquisitions were also performed by computer system for the changes in the concentration and temperature readings for steam, evaporation and cooling water at the both inlet and outlet. The control and the acquisition variables were collected through the interface device and analyzed by programs using the PASCAL language. To control the feeding rate during the concentration process, inverter was used. The cooling water for the vapor condensation was controlled by the valve controller and should be supplied with the flow rate of 125 kg/h. The maximum vapor condensation rate was 41.7kg/h at the feeding rate of 125 kg/h.

  • PDF

Development of Realtime Ubiquitous River Monitoring System (실시간 유비쿼터스 하천정보 모니터링 시스템의 개발)

  • Jang, Bok-Jin;Lee, Jong-Kook;Yeo, Woon-Kwang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1305-1312
    • /
    • 2006
  • This study is about the development of measurement system using ubiquitous wireless communication for river flow monitoring. The system can acquire water depth, quality (temperature, pH, conductivity, turbidity etc.) while a GPS module for getting the location data of measurement points. Also this system is able to acquire the field data via RF connection and can be controlled same time. The acquired data is transmitted to a gateway system from the remote buoy using Zigbee wireless connection. And the gateway system is able to monitor the data through GIS monitoring tool. Finally the data are transmitted to a server computer using CDMA wireless connection by gateway system. The D/B of server computer are constructed automatically and monitored the project web site. The resulting system can be used for scour monitoring, environment monitoring and the other monitoring purposes such as a river flow monitoring system.

  • PDF

Estimating Bathroom Water-uses based on Time Series Regression (시계열 회귀모형에 기초한 욕실 내 용수 사용량 추정)

  • Myoung, Sungmin;Kim, Donggeon;Jo, Jinnam
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.19-26
    • /
    • 2014
  • Analysis of influential factors on water consumption in households will help predicting the water demand of end-use in household and give an explanation to cause on the change of trend. In this research, the data are gathered by radio telemetry system which is combined electronic flow-meter and wireless communication system in 140 household in Korea. Using this data, we estimate for each residential type to determine liter per capita day. we used real data to predict bathtub and washbowl water-uses and compared the ordinary least square regression model and autoregressive regression error model. The results of this study can be applied in the planning stages of water and waste water facilities.

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

Computer Simulation of Viscoelastic Flow in a Capillary Die for Rubber Compounds (모세관 다이에서 고무 복합체의 점탄성 거동에 대한 컴퓨터 모사)

  • Park, Dong-Myung;Kim, Hok-Joo;Yoon, Jae-Ryong;Lyu, Min-Young
    • Elastomers and Composites
    • /
    • v.41 no.4
    • /
    • pp.223-230
    • /
    • 2006
  • Rubber compounds have a high viscoelastic property. One of the viscoelastic behaviors during profile extrusion is the swelling of extrudate, and the amount of swelling varies with operational conditions in extrusion. It is well recognized that the elastic portion in the viscoelastic property plays an important role in the extrudate swell. In this study computer simulation of the die swell at the capillary die for several rubber compounds has been performed using commercial CFD code, Polyflow. A non-linear differential viscoelastic model, Phan-Thien-Tanner (PTT) model, was used in the computer simulation. Non-isothermal behavior was considered in the calculation. Distribution of pressure, velocity and temperature in the reservoir and capillary die, and extrudate profiles were predicted through the simulation. The amount of the die swell fur the different rubber compounds was investigated for various flow rates and three types of length to diameter of the capillary die. It is concluded that the PTT model successfully represented viscoelastic behavior of rubber compounds.

Study on Fault Detection of a Gas Pressure Regulator Based on Machine Learning Algorithms

  • Seo, Chan-Yang;Suh, Young-Joo;Kim, Dong-Ju
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.4
    • /
    • pp.19-27
    • /
    • 2020
  • In this paper, we propose a machine learning method for diagnosing the failure of a gas pressure regulator. Originally, when implementing a machine learning model for detecting abnormal operation of a facility, it is common to install sensors to collect data. However, failure of a gas pressure regulator can lead to fatal safety problems, so that installing an additional sensor on a gas pressure regulator is not simple. In this paper, we propose various machine learning approach for diagnosing the abnormal operation of a gas pressure regulator with only the flow rate and gas pressure data collected from a gas pressure regulator itself. Since the fault data of a gas pressure regulator is not enough, the model is trained in all classes by applying the over-sampling method. The classification model was implemented using Gradient boosting, 1D Convolutional Neural Networks, and LSTM algorithm, and gradient boosting model showed the best performance among classification models with 99.975% accuracy.

Design of PI-type Fuzzy Logic Controller for a Turbojet Engine of Unmanned Aircraft (무인 항공기용 터보 제트 엔진의 PI-구조 퍼지 추론 제어기 설계)

  • Jie, Min-Seok;Mo, Eun-Jong;Lee, Kang-Woong
    • Journal of Advanced Navigation Technology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2005
  • In this paper we propose a turbojet engine controller of unmanned aircraft based on the Fuzzy-PI algorithm. To prevent any surge or a flame out event during the engine acceleration or deceleration, the PI-type fuzzy controller effectively controls the fuel flow input of the control system. The fuzzy inference rule made by the logarithm function of acceleration error improves the tracking error. Computer simulations applied to the linear model of a turbojet engine show that the proposed method has good tracking performance for the reference acceleration and deceleration commands.

  • PDF