• Title/Summary/Keyword: 유동 계수

Search Result 1,313, Processing Time 0.032 seconds

Airside Performance of Fin-and-Tube Heat Exchangers Having Round Wave Fins (둥근 웨이브 핀-관 열교환기의 공기 측 전열 성능)

  • Kim, Nae-Hyun
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.105-116
    • /
    • 2015
  • In this study, airside performance of round fin-and-tube heat exchangers are compared with that of the herringbone wave fin-and-tube heat exchangers with an aim to investigate the effect of fin shape on thermal performance. Results show that j factors of the round wave fin are 1.2~22% larger than those of herringbone wave fin. The f factors of the round wave fin are -1.0~29% smaller than those of herringbone wave fin for 1 or 2 row configuration. For 3 row configuration, f factors of the round wave fin are 8.3~23% larger. The reason may be attributed to the reduced recirculation zone in the valley of the fin for round wave fin as compared with that of the herringbone wave fin. For round wave fin, the effect of fin pitch on j and f factor is not significant. In addition, j factors decrease as the number of tube row increases. On the other hand, f factors are independent of the number of tube row. A new correlation was developed based on the present data.

A Study on the Prediction of Groundwater Contamination using GIS (GIS를 이용한 지하수오염 예측에 관한 연구)

  • Jo, Si-Beom;Shon, Ho-Woong;Lee, Kang-Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.12 no.2 s.29
    • /
    • pp.17-28
    • /
    • 2004
  • This study has tried to develop the modified DRASTIC Model by supplying the parameters, such as structural lineament density and land-use, into conventional DRASTIC model, and to predict the potential of groundwater contamination using GIS in Hwanam 2 District, Gyeonggi Province, Korea. Since the aquifers in Korea is generally through the joints of rock-mass in hydrogeological environment, lineament density affects to the behavior of groundwater and contaminated plumes directly, and land-use reflect the effect of point or non-point source of contamination indirectly. For the statistical analysis, lattice-layers of each parameter were generated, and then level of confidence was assessed by analyzing each correlation coefficient. Groundwater contamination potential map was achieved as a final result by comparing modified DRASTIC potential and the amount of pollutant load logically. The result suggest the predictability of contamination potential in a specified area in the respects of hydrogeological aspect and water quality.

  • PDF

A Study on the Influence of the Base Region Modeling on the Aerodynamic Characteristics of a Launch Vehicle Using CFD (CFD에 의한 발사체 공력특성에 미치는 기저부 영역 모델링의 영향에 관한 연구)

  • Kim, Young-Hoon;Ok, Ho-Nam;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.9
    • /
    • pp.27-33
    • /
    • 2005
  • This research presents the influence of the base region modeling on the aerodynamic characteristics of a launch vehicle using CFD. The vicinity of a launch vehicle is divided into four zones, and four computational cases are made using these four zones. The aerodynamic coefficients are predicted for the angle-of-attack of 6 degrees and Mach numbers ranging from 0.4 to 2.86. It was found that modeling of the base region should not be neglected for the prediction of the aerodynamic characteristics of a launch vehicle in subsonic and transonic regions. It was also found that the modeling of the sting support used in the wind tunnel test is necessary to get a better agreement with the experiments.

A New Natural Convection Heat Transfer Correlation for Laminar and Turbulent Film Condensation Derived from a Statistical Analysis of Existing Models and Data (기존모델과 실험자료의 통계적 분석에 의해 유도한 층류 및 난류 막응축에 대한 새로운 자연대류 열전달 관계식)

  • Chun, Moon-Hyun;Kim, Kyun-Tae
    • Nuclear Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.200-209
    • /
    • 1991
  • A new semi-empirical average heat transfer correlation applicable for both laminar and turbulent film-wise condensation on a vertical surface has been presented. Re functional form of the present correlation is based on the representative existing correlations for laminar and turbulent film flows, whereas the numerical coefficients of the present correlation have been determined by the least squares method using experimental data obtained from the open literatures. In addition, the performance of the present as well as the seven existing correlations (four for laminar and three for turbulent film flow regimes) were evaluated for their accuracy and the range of application. The result shows that for laminar film filow regimes Zazuli's and the present correlations give the samllest values of mean error, whereas for turbulent film How regimes Kirkbride and Badger's and the present correlations produce the smallest values of mean error.

  • PDF

A study on the development of constant temperature hot wire type air flow meter for automobiles (자동차용 정온도 열선식 공기유량계의 개발에 관한 연구)

  • 조성권;유정열;고상근;김동성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.12
    • /
    • pp.2407-2414
    • /
    • 1992
  • Constant temperature hot wire air flow meter for automobiles requires temperature compensation system because hot wire output signal is sensitive to ambient temperature variations as well as fluid velocity. The objectives of the present study are to design an air flow meter circuit which is capable of compensating the hot wire output signal for ambient temperature variations and to investigate the mechanism of such temperature compensation. This circuit is composed of platinum hot wire, platinum resistor, two variable resistors, a constant resistor and a DC-amplifier. In particular, by simply replacing a constant resistor in one of the bridge arms of the conventional circuit with platinum resistor and a variable resistor for the purpose of temperature compensation, the deviation of output signal with respect to ambient temperature variations between 27deg. C 70deg. C could be reduced to less than 2.5% for mass flow rate and to less than 5% for velocity respectively. The mechanism of temperature compensation against ambient temperature variations was explained by means of measuring the heat transfer coefficient with hot wire temperature variations and analyzing and analyzing conventional empirical equations qualitatively.

Investigation for Spray Characteristics of Dual Swirl Injector (이중 스월 인젝터의 분무특성에 관한 연구)

  • Park Hee Ho;Jeong Chung Yon;Kim Yoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.1
    • /
    • pp.17-26
    • /
    • 2005
  • Both numerical analysis and cold tests for the swirl coaxial type injector were performed to obtain the influence of spray angle, velocity ratio and liquid film thickness for pressure drop and recess. The basic experimental and numerical data obtained in this study can be applicable to the performance design of swirl coaxial type injector. Spray angle was not affected by the applied test pressure drop, but spray angle was affected by tangential velocity ratio and shape factors. Feasibility of numerical analysis for the liquid film thickness and spray angle was confirmed, and the change of liquid film thickness by tangential velocity ratio affected more seriously than pressure drop, and liquid film thickness was decreased with increasing tangential velocity ratio.

Numerical Analysis on Radiative Heating of a Plume Base in Liquid Rocket Engine (플룸에 의한 액체로켓 저부면 복사 가열 해석)

  • Sohn Chae Hoon;Kim Young-Mog
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.9 no.3
    • /
    • pp.85-91
    • /
    • 2005
  • Radiative heating of a liquid rocket base plane due to plume emission is numerically investigated. Calculation of flow and temperature fields around rocket nozzle precedes and thereby realistic plume shape and temperature distribution inside the plume are obtained. Based on the calculated temperature field, radiative transfer equation is solved by discrete ordinate method. With the sample rocket plume, the averaged radiative heat flux reaching the base plane is calculated about 5 kw/m$^{2}$ at the flight altitude of 10.9 km. This value is small compared with radiative heat flux caused by constant-temperature (1500 K) plume emission, but it is not negligibly small. At higher. altitude (29.8km), view factor between the base plane and the exhaust plume is increased due to the increased expansion angle of the plume. Nevertheless, the radiative heating disappears since the base plane is heated to high temperature (above 1000 K due to convective heat transfer.

Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube (마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향)

  • Park, Cheol-Min;An, Young-Tae;Lee, Wook-Hyun;Kim, Jeung-Hoon;Kim, Jong-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

Effects of Discrete Rib-Turbulators on Heat/Mass Transfer Augmentation in a Rectangular Duct (사각 덕트 내부 열전달 향상을 위한 요철의 단락 효과)

  • Kwon, Hyuk-Jin;Wu, Seong-Je;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.744-752
    • /
    • 2000
  • The influence of arrangement and length of discrete ribs on heat/mass transfer and friction loss is investigated. Mass transfer experiments are conducted to obtain the detailed local heat/mass transfer information on the ribbed wall. The aspect ratio (width/height) of the duct is 2.04 and the rib height is one tenth of the duct height, such that the ratio of the rib height to hydraulic diameter is 0.0743. The ratio of rib-to-rib distance to rib height is 10. The discrete ribs were made by dividing each continuous rib into 2, 3 or 5 pieces and attached periodically to the top and the bottom walls of the duct with a parallel orientation The combined effects of rib angle and length of the discrete ribs on heat/mass transfer ae considered for the rib angles $({\alpha})\;of\;90^{\circ}\;and\;45^{\circ}$. As the number of the discrete ribs increases, the uniformity of the heat/mass transfer distributions increases. For $(\alpha})=90^{\circ}$, the heat/mass transfer enhancement with the discrete ribs is remarkable, while the heat/mass transfer performances are slightly higher than that of the transverse continuous ribs due to the accompanied high friction loss penalty. For $(\alpha})=90^{\circ}$, the average heat/mass transfer coefficients and the heat/mass transfer performances decrease slightly with the discrete ribs compared to the case of the angled continuous ribs.

Development of a Current-Type Electromagnetic Flowmeter to Obtain the Liquid Mean Velocity in Two-Phase Slug Flow (슬러그류 액상속도 측정용 전류형식 전자기유량계 개발)

  • Kang, Deok-Hong;Ahn, Yeh-Chan;Kim, Jong-Rok;Oh, Byung-Do;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1951-1956
    • /
    • 2004
  • The transient nature and complex flow geometries of two-phase gas-liquid flows cause fundamental difficulties when measuring flow velocity using an electromagnetic flowmeter. Recently, a current-sensing flowmeter was introduced to obtain measurements with high temporal resolution (Ahn et $al.^{(1)}$). In this study, current-sensing flowmeter theory was applied to measure the fast velocity transients in slug flows. To do this, the velocity fields of axisymmetric gas-liquid slug flow in a vertical pipe were obtained using Volume-of-Fluid (VOF) method and the virtual potential distributions for the electrodes of finite size were also computed using the finite volume method for the simulated slug flow. The output signal prediction for slug flow was carried out from the velocity and virtual potential (or weight function) fields. The flowmeter was numerically calibrated to obtain the cross-sectional liquid mean velocity at an electrode plane from the predicted output signal. Two calibration parameters are required for this procedure: a flow pattern coefficient and a localization parameter. The flow pattern coefficient was defined by the ratio of the liquid resistance between the electrodes for two-phase flow with respect to that for single-phase flow, and the localization parameter was introduced to avoid errors in the flowmeter readings caused by liquid acceleration or deceleration around the electrodes. These parameters were also calculated from the computed velocity and virtual potential fields. The results can be used to obtain the liquid mean velocity from the slug flow signal measured by a current-sensing flowmeter.

  • PDF