• Title/Summary/Keyword: 유동장

Search Result 2,072, Processing Time 0.026 seconds

Numerical Estimation of Heat flux on the Deck Exposed to the High Temperature Impinging Jet of VTOL Vehicle (수직 이착륙기의 고온 고속 배기열에 의한 함정 갑판의 열유속 계산을 위한 수치모델)

  • Jang, Hosang;Hwang, Seyun;Choi, Wonjun;Lee, Jang Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.74-85
    • /
    • 2018
  • This study has analyzed the convective heat transfer on the deck exposed to the high-temperature impingement exhausting from a VTOL vehicle. The heat flow of the impingement on the deck is modeled by the convection heat transfer. The convective heat flux generated by the hot impinging jet is investigated by using both convective heat transfer formulation and conjugate heat transfer formulation. Computational fluid dynamics(CFD) code was used to compute the heat flux distribution. The RANS equation and the k-e turbulence model were used to analyze the thermal flow of the impinging jet. The heat flux distribution near the stagnation zone obtained by the conjugate heat transfer analysis shows more reasonable than the convective heat transfer analysis.

A study on the influence of turbulence characteristics on burning speed in swirl flow field (스월유동장에 있어서 연소속도에 미치는 난류특성의 영향에 관한 연구)

  • Lee, Sang Jun;Lee, Jong-Tai;Lee, Song-Yol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.244-254
    • /
    • 1996
  • Flow velocity was measured by, use of hot wire anemometer. Turbulence intensity was in proportion to mean flow velocity regardless of swirl velocity. And integral length scale has proportional relation with swirl velocity regardless of measurement position. Turbulent burning speed during flame propagation which was determined by flame photograph and gas pressure of combustion chamber was increased with the lapse of time from spark and was decreased a little at later combustion period. Because of combustion promotion effect, turbulent burning speed was increased according to increase of turbulence intensity. Burning speed ratio i.e. ratio of turbulent burning speed ($S_BT$) to laminar burning speed ($S_BL$) was found out by use of turbulence intensity u' and integral length scale $l_x$ , $\delta_L$ is width of preheat zone in laminar flame.

Characteristics of Cold Water Appeared in the Southwestern East Sea (동해 남서부해역에 출현하는 냉수 특성)

  • Lee, Moon-Ock;Otake, Shinya;Kim, JongKyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.3
    • /
    • pp.455-473
    • /
    • 2014
  • 하계 동해의 남서부해역에 냉수가 왜 그리고 어떠한 해양환경하에 출현하는가를 밝히기 위하여 현장조사, 위성자료의 분석 및 수치실험을 실시하였다. 이 해역에서 냉수는 비정상년의 경우는 정상년에 비해 보다 더 연안 가까이에서 출현하였고, 수온도 낮았다. 이것은 냉수가 비정상년에는 정상년에 비해 크게 발달하여 연안역으로 확장함을 의미하였다. 흐름장의 계산결과는 지형류적인 관점에서 수온의 관측결과를 잘 재현하였다. 한편, 정상년의 경우는, 북한한류(NKCW)가 쓰시마난류(TC)와 균형을 유지하면서 동해의 북서쪽에 머물고 있었다. 이에 반해, 비정상년의 경우는, 북한한류가 점차 남쪽으로 남하하여 동해 서부역의 대부분이 북한한류의 세력하에 놓였다. 그래서, 하계 동해 서부 연안역에서의 냉수 출현은 남쪽으로의 북한한류의 확장에 의한 부산물인 것으로 판단되었다. 울산 연안역에 대한 유동계산결과는 하계 남풍이 불 경우, 표층과 저층 사이에 흐름의 역전현상이 나타났다. 따라서, 하계 동해의 남서부 연안역, 특히 수심의 변화가 급한 방어진 부근에서 냉수의 용승이 일어날 수 있음을 시사하였다.

A Numerical Study on the Effect of the Shape of Windows on the Ventilation Performance in the Storage Hall of Tripitaka Koreana at Haein Temple (해인사 장경판전 환기창 형태에 따른 환기 성능에 대한 수치해석 연구)

  • Hur, Nahm-Keon;Lee, Myung-Sung;Yang, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.119-123
    • /
    • 2007
  • Ventilation performance in the storage hall of Janggyeongpan Jeon has maintained for more than 600 years. Janggyeongpan Jeon in Haein temple has window structure of bi-level ventilating opening which consists of upper and lower window. Also, different size and shape of windows are adopted for various locations of the hall. In the present study, to analyze effect of shape of windows on ventilation performance in the storage hall, various design alternatives were considered. Numerical analysis of ventilation in the storage hall was investigated under the same simulation condition except for the shape of windows. Through the comparison of numerical results for various window designs, it was evaluated that the current windows shape gives best ventilation performance.

  • PDF

Heat Transfer Analysis for Variable Thrust Control System Using 1-Way Coupling (일방향 연계를 활용한 연속가변 추력제어 시스템의 열전달 해석)

  • Lee, JiHun;Jang, HanNa;Kim, GyuBin;Cho, JinYeon;Kawk, JaeSu;Ko, JunBok;Park, SungHan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.388-391
    • /
    • 2017
  • In this study, heat transfer analysis of variable thrust control system have been conducted by using commercial CFD code and FEM code. We Carried out computational fluid dynamics analysis to obtain the temperature and convective heat transfer coefficient of hot gas of variable thrust control system. Data are used as boundary condition for heat transfer analysis using mapping method. Temperature of O-ring for sealing was predicted

  • PDF

Analysis on the Flow and Heat Transfer in a Large Scale CVD Reactor for Si Epitaxial Growth (Si 선택적 성장을 위한 대형 CVD 반응기 내의 열 및 유동해석)

  • Jang, Yeon-Ho;Ko, Dong Guk;Im, Ik-Tae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.41-46
    • /
    • 2016
  • In this study, gas flow and temperature distribution in the multi-wafer planetary CVD reactor for the Si epitaxial growth were analyzed. Although the structure of the reactor was simplified as the first step of the study, the three-dimensional analysis was performed taking all these considerations of the revolution of the susceptor and the rotation of satellites into account. From the analyses, a reasonable velocity field and temperature field were obtained. However, it was found that analyses including the upper structure of the reactor were required in order to obtain more realistic temperature results. DCS mole fraction above the satellite surface and the susceptor surface without satellite was compared in order to check the gas species mixing. We found that satellite rotation helped gases to mix in the reactor.

Finite Element Analysis for Dielectric Liquid Discharge under Lightning Impulse Considering Two-Phase Flow (절연유체 내 2상유동을 고려한 뇌임펄스 응답 유한요소해석)

  • Lee, Ho-Young;Lee, Jong-Chul;Chang, Yong-Moo;Lee, Se-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.11
    • /
    • pp.2097-2102
    • /
    • 2011
  • Discharge analysis technique for dielectric liquid was presented by using the Finite Element Analysis (FEA) under a lightning impulse incorporating two-phase flow phenomena which described gas and liquid phases in discharge space. Until now, the response of step voltage has been extensively explored, but that of lightning impulse voltage was rarely viewed in the literature. We, therefore, developed an analyzing technique for dielectric liquid in a tip-sphere electrode stressed by a high electric field. To capture the bubble phase, the Heaviside function was introduced mathematically and the material functions for the ionization, dissociation, recombination, and attachment were defined in liquid and bubble, respectively. By using this numerical setup, the molecular dissociation and ionization mechanisms were tested under low and high electric fields resulted from the lightning impulse voltage of 1.2/50 ${\mu}s$. To verify our numerical results, the velocity of electric field wave was measured and compared to the previous experimental results which can be viewed in many papers. Those results had good agreement with each other.

Two-Dimensional Finite Element Analysis for Tidal Flat Simulation (조간대 모의를 위한 2차원 유한요소해석)

  • 서승원;박원경
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.1
    • /
    • pp.103-113
    • /
    • 1996
  • Two-dimensional finite element hydrodynamic models for long wave simulation usually adopt fixed land boundary. However moving boundary treatment is strongly required in the simulation of tidal flats for west and south coast of Korea. In this study very efficient and realistic moving boundary treatment is applied by considering incident long wave surface slope. Developed STEP-CM (Superior Two-step Explicit Program for Coastal Modeling) ,shows numerically stable results in comparative study for idealized one-dimensional channel. Real application of the model is done for Chonsu Bay where tidal flats are distributed along the coast. Nonlinear tidal current and tidal flat effects are easily simulated in STEP-CM and resulting circulations are detected around headland of Wonsan Island.

  • PDF

A method for predicting the aerodynamic performance of low-speed airfoils (저속익형의 공기역학적 성능예측의 한 방법)

  • Yu, Neung-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.240-252
    • /
    • 1998
  • The purpose of this study is to develop a method for predicting the aerodynamic performance of the low speed airfoils in the 2-dimensional, steady and viscous flow. For this study, the airfoil geometry is specified by adopting the longest chord line system and by considering local surface curvature. In case of the inviscid incompressible flow, the analysis is accomplished by the linearly varying strength vortex panel method and the Karman-Tsien correction law is applied for the inviscid compressible flow analysis. The Goradia integral method is adopted for the boundary layer analysis of the laminar and turbulent flows. Viscous and inviscid solutions are converged by the Lockheed iterative calculating method using the equivalent airfoil geometry. The analysis of the separated flow is performed using the Dvorak and Maskew's method as the basic method. The wake effect is also considered by expressing its geometry using the formula of Summey and Smith when no separation occurs. The computational efficiency is verified by comparing the computational results with experimental data and by the shorter execution time.

Development of Stereoscopic PIV Measurement Technique and Its Application to Wake behind an Axial Fan (Stereoscopic PIV 기법의 개발과 이를 이용한 축류 홴 후류의 유동해석)

  • Yun, Jeong-Hwan;Lee, Sang-Jun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.2
    • /
    • pp.362-373
    • /
    • 2002
  • A stereoscopic PIV (SPIV) measurement system based on the translation configuration was developed and applied to the flow behind a forward-swept axial-fan. Measurement of three orthogonal velocity components is essential for flow analysis of three-dimensional flows such as flow around a fan or propeller. In this study, the translation configuration was adopted to calculate the out-of-plane velocity component from 2-D PIV data obtained from two CCD cameras. The error caused by the out-of-plane motion was estimated by direct comparison of the 2-D PIV and 3-D SPIV results that measured from the particle images captured simultaneously. The comparison shows that the error ratio is relatively high in the region of higher out-of-plane motion near the axial fan blade. The turbulence intensity measured by the 2-D PIV method is bigger by about 5.8% in maximum compared with that of the 3-D SPIV method. The phase-averaged velocity field results show that the wake behind an axial fan has a periodic flow structure with respect to the blade phase and the characteristic flow structure is shifted downstream in the next phase.