A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters (유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

Characteristics of Multipath Ultrasonic Flowmeter Installed Upstream and Downstream of Flow Disturbance Factors-Contraction, Expansion, and Tee Pipe (유동교란인자(축소·확대관, Tee관)상하류에 설치된 다회선초음파 유량계의 특성)

  • Lee, Dong-Keun;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.877-883
    • /
    • 2012
  • Multipath ultrasonic flowmeters are increasingly being used for the purpose of accurate flow measurement. However, an installation standard has not yet been established for these flowmeters, and this can cause considerable confusion during field installation. There is a need for a minimum straight run to ensure the measurement accuracy of a flowmeter installed upstream and downstream of flow disturbance factors-expansion, contraction, and tee pipes. Experiments were performed by using multipath flowmeters that have less than ${\pm}0.5%$ accuracy-4-paths 1-unit and 2-paths 1-unit are of foreign make, whereas 5-paths 2-units are of domestic make-to determine the straight run under the above conditions. We carried out experiments repeatedly by considering a straight run, velocity, and suggested installation standards for a multipath ultrasonic flowmeter that satisfies the tolerance limits.

Error Characteristics of Clamp-on Ultrasonic Flowmeters Depending on Location of Sensors and Downstream Straight Run of Bent Pipe (곡관후단의 직관거리와 센서위치에 따른 초음파유량계의 오차특성)

  • Lee, Dong-Keun;Cho, Yong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.8
    • /
    • pp.861-868
    • /
    • 2011
  • Flowmeters that measure the amount of fluid passing through conduits must kept accurate by comparison and the periodic calibration. The reference meters used are clamp-on meters that mount sensors on the outer wall of the pipe. They are called 1-path, 2-path or 4-path flowmeters depending on the number of sensors. We selected a flowmeter mainly used for K-water as test a flowmeter. We carried out experiments to find the intrinsic error of the flowmeter and errors in the downstream of a double bent pipe. The results show that there are the sensor locations that meet the tolerance. We suggested the angle of the sensor, the straight run from the downstream of the bent pipe and the number of sensors. So it is possible to improve the water treatment process and increase the accounted water rate by upgraded flow measurement technology.

Atherogenic Risk Stratification According to Changes in the Geometrical Shape of the Coronary Artery (관상동맥의 기하학적 형상변화에 따른 동맥경화 위험도)

  • Suh, Sang-Ho;Park, Jun-Gil;Roh, Hyung-Woon;Lee, Byung-Kwon;Kwon, Hyuck-Moon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.893-899
    • /
    • 2010
  • A previous study showed that hemodynamics is correlated with stenosis in the coronary artery. The flow characteristics and the distributions of the hemodynamic wall parameters in the coronary artery are investigated under physiological flow condition. The present study also aims to establish the mechanism of the generation of atherosclerosis by analyzing the hemodynamic variables in the coronary artery where atherosclerosis frequently occurs. The stenosis phenomena due to atherosclerosis are related to not only the biochemical reaction between blood and blood vessels but also the hemodynamic factors sush as flow separation and oscillatory wall shear stress. As the bifurcated angle increases, the size of the recirculation area that appears in the cross section increases and disturbed flow is observed in this area. We speculate that this area is the starting point of atherosclerosis in the coronary artery.

Deviation Characteristics of Clamp-on Type Ultrasonic Flowmeter Installed in Downstream of Valves (밸브 하류에 설치된 건식 초음파유량계의 편차특성)

  • Lee, Dong-Keun;Cho, Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.4
    • /
    • pp.12-18
    • /
    • 2012
  • This study was performed to found out the deviations for clamp-on type ultrasonic flowmeter installed in downstream of valves. It was selected three types of two-path flowmeter mainly used for K-water as test. Experiment carried out to confirmed characteristics of deviation depending on the sensor location, straight pipe length and maker for 1-path, 2-path and 4-path combined 2-path flowmeter. It was selected two kinds of valves with 100 % and 50 % opening, butterfly valves and gate valves, for flow disturbance factor. Finally, we suggested number of sensors by maker, straight pipe length and installed location of sensors satisfying the tolerance depending on the experiment results.

Interfacial shear stresses and friction factors in nearly-horizontal countercurrent stratified two-phase flow (근사수평 반류성층 2상유동에서의 계면전단응력 및 마찰계수)

  • 이상천;이원석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.1
    • /
    • pp.116-122
    • /
    • 1988
  • Interfacial shear stresses have been determined for countercurrent stratified flow of air and water in a nearly-horizontal rectangular channel, based upon measurements of pressure drop, gas velocity profiles and mean film thickness. A dimensionless correlation for the interfacial friction factor has been developed as a function of the gas and liquid Reynolds numbers. Equivalent surface roughnesses for the interfacial friction factor have been calculated using the Nikuradse correlation and have been compared with the intensity of the wave height fluctuation on the interface. The results show that the interfacial shear stress is mainly affected by turbulent mixing near the interface due to the wave motion rather than by the roughened surface.

Analysis on the Flow Field Around a Hydrofoil with Surface Blowing (표면 유체분출 수중날개의 유동해석)

  • Sang-Woo Pyo;Jung-Chun Suh;Hyo-Chul Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.36 no.4
    • /
    • pp.21-27
    • /
    • 1999
  • A low order panel method based on the perturbation potential is applied for prediction of performance of blown-flap rudders. In order to improve the solution behavior at the large angle of attacks, the geometry of the trailing wake sheet is computed by aligning freely with the local flow. The effect of the wake sheet roll-up is also included with use of a high order panel method. The flow in the gap between the main component and the flap of the rudder is modeled as Couette flow. The effects of the gap and the flow jet are included in application of a kinematic and a dynamic boundary condition on the inlet and the outlet of the gap as well as on the flap and the wake. The results with the present method are compared with existing experimental data. The method is shown to be capable of determining accurately the flow characteristics even for large flap angles.

  • PDF

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

Study on Supersonic Jet Noise Reduction Using a Mesh Screen (메쉬 스크린을 이용한 초음속 제트소음 저감법에 관한 실험적 연구)

  • Kweon, Yong-Hun;Lim, Chae-Min;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.377-381
    • /
    • 2006
  • This paper describes experimental work to control supersonic jet noise using a mesh screen that is placed at the nozzle exit plane. The mesh screen is a wire-gauze screen that is made of long stainless wires with a very small diameter. The nozzle pressure ratio is varied to obtain the supersonic jets which are operated in a wide range of over-expanded to moderately under-expanded jets. In order to perturb mainly the initial jet shear layer, the hole is perforated in the central part of the mesh screen. The hole size is varied to investigate the noise control effectiveness of the mesh screen. A schlieren optical system is used to visualize the flow fields of supersonic jet with and without the mesh screen device. Acoustic measurement is performed to obtain the OASPL and noise spectra. The results obtained show that the present mesh screen device leads to a substantial suppression of jet screech tones. The hole size is an important factor in reducing the supersonic jet noise. For over-expanded jets, the noise control effectiveness of the mesh screen appears more significant, compared to correctly and under-expanded jets

  • PDF